supply of - air filter , armature outer brg , avr plate , cylinder bore , cylinder assy with inlet and exhaust valve , push rod , push tube , fan belt , fuel feed pump with fuel filter assy , fuel injection pump , fuel rerurn adapter , fuel pipe , injector assy , oil filter , piston ring set , tapped cover , rocker , head gasket , cylinder head assy with inlet and exhaust valve , head gasket , oil pipeline , air filter , push rod , push tube o ring , injector , cell , connecting rod , cyl head assy with valve , oil filter , pistion ring set , piston , push tube seal , push rod seal lower , push rod seal upper , rocker arm assy , sleeve cyl assy , single element fuel pump oblique fip , armature , big end cell , cylinder head with inlet and exhaust valve , cylinder bore , exhaust fan , fuel pipe line tank to feed pump , fuel filter , injectors , packing kit , pistion assy , pistion ring , push tube , push tube seal , tappet cover , benjo nut , cells , fip , cylinder head assy , engine packing kit , fuel pipe line feed pump to fip , fuel pipe line tank to feed pump , fuel pipe line pump to filter , fuel feed pump , hose clamp , injector nozzle , over flow pipe line , sleeve , tappet cover , tappet gasket , push tube seal , turbo charger , crank shaft , fuel line pipe , fuel pipe tank to pump - mta genr spares | quantity - 378
supply of - air filter , armature outer brg , avr plate , cylinder bore , cylinder assy with inlet and exhaust valve , push rod , push tube , fan belt , fuel feed pump with fuel filter assy , fuel injection pump , fuel rerurn adapter , fuel pipe , injector assy , oil filter , piston ring set , tapped cover , rocker , head gasket , cylinder head assy with inlet and exhaust valve , head gasket , oil pipeline , air filter , push rod , push tube o ring , injector , cell , connecting rod , cyl head assy with valve , oil filter , pistion ring set , piston , push tube seal , push rod seal lower , push rod seal upper , rocker arm assy , sleeve cyl assy , single element fuel pump oblique fip , armature , big end cell , cylinder head with inlet and exhaust valve , cylinder bore , exhaust fan , fuel pipe line tank to feed pump , fuel filter , injectors , packing kit , pistion assy , pistion ring , push tube , push tube seal , tappet cover , benjo nut , cells , fip , cylinder head assy , engine packing kit , fuel pipe line feed pump to fip , fuel pipe line tank to feed pump , fuel pipe line pump to filter , fuel feed pump , hose clamp , injector nozzle , over flow pipe line , sleeve , tappet cover , tappet gasket , push tube seal , turbo charger , crank shaft , fuel line pipe , fuel pipe tank to pump - mta genr i | quantity - 378
supply of - air filter , armature outer brg , avr plate , cylinder bore , cylinder assy with inlet and exhaust valve , push rod , push tube , fan belt , fuel feed pump with fuel filter assy , fuel injection pump , fuel rerurn adapter , fuel pipe , injector assy , oil filter , piston ring set , tapped cover , rocker , head gasket , cylinder head assy with inlet and exhaust valve , head gasket , oil pipeline , air filter , push rod , push tube o ring , injector , cell , connecting rod , cyl head assy with valve , oil filter , pistion ring set , piston , push tube seal , push rod seal lower , push rod seal upper , rocker arm assy , sleeve cyl assy , single element fuel pump oblique fip , armature , big end cell , cylinder head with inlet and exhaust valve , cylinder bore , exhaust fan , fuel pipe line tank to feed pump , fuel filter , injectors , packing kit , pistion assy , pistion ring , push tube , push tube seal , tappet cover , benjo nut , cells , fip , cylinder head assy , engine packing kit , fuel pipe line feed pump to fip , fuel pipe line tank to feed pump , fuel pipe line pump to filter , fuel feed pump , hose clamp , injector nozzle , over flow pipe line , sleeve , tappet cover , tappet gasket , push tube seal , turbo charger , crank shaft , fuel line pipe , fuel pipe tank to pump - mta iv | quantity - 307
supply of - air filter , armature outer brg , avr plate , cylinder bore , cylinder assy with inlet and exhaust valve , push rod , push tube , fan belt , fuel feed pump with fuel filter assy , fuel injection pump , fuel rerurn adapter , fuel pipe , injector assy , oil filter , piston ring set , tapped cover , rocker , head gasket , cylinder head assy with inlet and exhaust valve , head gasket , oil pipeline , air filter , push rod , push tube o ring , injector , cell , connecting rod , cyl head assy with valve , oil filter , pistion ring set , piston , push tube seal , push rod seal lower , push rod seal upper , rocker arm assy , sleeve cyl assy , single element fuel pump oblique fip , armature , big end cell , cylinder head with inlet and exhaust valve , cylinder bore , exhaust fan , fuel pipe line tank to feed pump , fuel filter , injectors , packing kit , pistion assy , pistion ring , push tube , push tube seal , tappet cover , benjo nut , cells , fip , cylinder head assy , engine packing kit , fuel pipe line feed pump to fip , fuel pipe line tank to feed pump , fuel pipe line pump to filter , fuel feed pump , hose clamp , injector nozzle , over flow pipe line , sleeve , tappet cover , tappet gasket , push tube seal , turbo charger , crank shaft , fuel line pipe , fuel pipe tank to pump - mta genr spare iv | quantity - 1034
nit for procurement, fabrication and transportation of alumunium door and windows on works contract basis for our "combined station works of mechanical, civil, electrical and instrumentation works and other facilities under kandla-gorakhpur liquefied petroleum gas (lpg) pipeline project of indian oil corporation limited on behalf of ihb limited at bina in madhya pradesh state
Annexures in one click — AI extracts, fills & formats
annual civil maintenance contract (acmc) for the year 2026-27 construction/ maintenance of townships and/ or construction/ maintenance of wharves and/or construction/ maintenance of port structures and/or civil construction/repair/ maintenance/retrofitting works and/or item rate contracts (1) clearing grass and removing rubbish within 50 meters, (2) clearing jungle uprooting rank vegetation and trees up to 30 cm in girth, (3) surface dressing of soil up to 15 cm deep, (4) cutting, sectioning, and leveling earth mounds using hirable jcb excavators, (5) transporting surplus materials and building debris using 6m heavy tipper lorries within a 6 km radius, (6) shifting waste utilizing 3m mini tipper lorries within 6 km, (7) wire-broom sweeping and cleaning container yards, wharf frontages, and active berths, (8) manually or mechanically demolishing brickwork built in cement mortar, (9) breaking down stone rubble masonry structures, (10) breaking down rich nominal concrete mixes of 1:3:6 or higher, (11) breaking down lean concrete mixtures of 1:4:8 or lower, (12) dismantling tiled roof structures along with their battens and boarding, (13) stripping galvanised steel sheet roofing including all ridges, hips, and gutters, (14) removing decayed asbestos cement sheet roof panels, (15) dismantling heavy woodwork frames, trusses, and purlins up to a 10-meter span, (16) taking out old steel or timber doors, windows, and clerestory shutters, (17) repairing wall plaster patches under 2.5 square meters using 1:4 cement mortar, (18) stripping old plaster or skirting and raking joints for re-plastering, (19) renewing wooden roof battens and coating them with wood preservatives, (20) demolishing reinforced cement concrete and neatly stacking recovered steel reinforcing bars, (21) dismantling cement asbestos or hardboard false ceilings and partition walls, (22) shallow surface excavation under 30 cm deep over plan layouts, (23) deep earth excavation exceeding 30 cm in depth using manual or mechanical means, (24) digging foundation trenches or drains including dressing side slopes, (25) mechanically loading and transporting building rubbish to municipal dumping grounds, (26) backfilling foundation trenches in 20cm layers using ramming and watering, (27) scraping off dry or oil-bound distemper and smoothing walls with sandpaper, (28) removing old whitewash or color wash coatings by scraping, (29) re-roofing with single mangalore tiles set in lime mortar, (30) re-roofing with double mangalore tiles set in lime mortar, (31) removing precast rcc drain cover slabs, desilting channels, and re-laying slabs, (32) sweeping and cleaning accumulated road dust and wharf-side rubbish, (33) emptying public dustbins and hauling branches to the mattancherry bridge dump, (34) mixing and spraying department-supplied chemical weedicides across willingdon island, (35) cutting through hard bituminous or concrete road surfaces, (36) unblocking and removing waste from centralized hume pipe drains in warehouses, (37) stripping old barbed wire fencing and rolling lines into transportable bundles, (38) dismantling aluminium windows, doors, partitions, and false ceiling components, (39) removing old roof eaves gutters, downpipes, and retention brackets, (40) structural dismantling of steel angles, channels, and tees by unbolting or cutting rivets, (41) raking out old mortar joints to prepare stone walls for fresh repointing, (42) re-laying old precast cement concrete pavement blocks over walks, (43) installing adjustable fiber-cement corrugated ridges and hips, (44) scraping off decayed mortar to clean recovered stone and concrete blocks, (45) draining, scrubbing, and bleaching the 326 kl concrete underground fresh-water tank, (46) chemical cleaning and scrubbing of the 546 kl steel overhead water storage tank, (47) breaking up damaged old tile floors along with their base cement plaster, (48) removing worn cast iron water sluice valves exceeding 150mm in diameter, (49) stripping old floor or roof tile work where thickness ranges between 10mm to 25mm, (50) clearing silt and maintaining fluent water flow across structural storm drains, (51) cutting out and removing damaged 4-inch galvanised iron fresh-water lines, (52) laying replacement 4-inch galvanised iron pipe tracks supplied by the port, (53) erecting external cup-lock double tube scaffolding systems up to seven stories high, (54) loading, hauling, and setting down heavy concrete walkway protection bollards, and (55) chemically washing and cleaning office revolving chairs; moving into part-b material-and-labour-involved works, the schedule progresses through (56) filling and consolidating fine quarry dust inside structural basements, (57) filling basements using a blended mix of 6mm metal aggregate and quarry dust, (58) spreading a 100mm gravel layer topped with 15mm screenings rolled to 75mm, (59) laying grade 1:1:3 cement concrete foundations up to plinth level, (60) pouring structural 1:2:4 cement concrete works up to plinth level, (61) casting 1:3:6 nominal concrete base courses up to plinth level, (62) pouring concrete mix 1:3:6 using larger 40mm stone aggregate, (63) laying lean mix 1:4:8 concrete using 40mm aggregate below foundations, (64) setting up and removing formwork for foundations and column bases, (65) erecting shuttering for retaining walls, return walls, kerbs, and steps, (66) erecting vertical shuttering for structural pillars, columns, and piers, (67) positioning precast concrete kerbs with 1:3 mortar at ground level, (68) pouring structural 1:1:3 concrete into retaining walls up to floor v, (69) pouring intermediate 1:2:4 concrete into superstructure walls up to floor v, (70) pouring nominal 1:3:6 concrete into superstructure partitions up to floor v, (71) constructing random rubble masonry using fresh hard stones in foundations, (72) building random rubble masonry utilizing old recovered departmental stones, (73) building foundation masonry with clay bricks in 1:4 cement mortar, (74) building foundation masonry with clay bricks in 1:6 cement mortar, (75) building upper walls with clay bricks in 1:4 mortar up to floor v, (76) building upper walls with clay bricks in 1:6 mortar up to floor v, (77) erecting partition walls using precast solid concrete blocks in a 1:1.5:3 mix, (78) erecting walls with precast solid concrete blocks in a 1:2:4 mix, (79) erecting walls with precast solid concrete blocks in a 1:3:6 mix, (80) building upper partitions up to floor v using precast hollow concrete blocks, (81) fabricating premium wood frames for doors and windows using ayini or jack wood, (82) making and fixing 30mm or 35mm panelled doors using jack wood, (83) glazing timber frames using 4mm or 5mm thick float glass panes, (84) installing mechanical m.s. lath rolling shutters with high-tensile springs, (85) equipping large rolling shutters with chain and crank gear operating devices, (86) providing and fixing smooth ball bearings inside rolling shutter boxes, (87) assembling anodized architectural aluminium door, window, and partition frames, (88) fixing 12 mm thick decorative pre-laminated particle boards into frames, (89) fitting 4 mm float glass panes into aluminium sections using epdm gaskets, (90) providing grade 304 stainless steel fly-proof wire mesh with mild steel u-beading, (91) embedding 40x5mm flat iron frame anchors into concrete blocks, (92) installing heavy-duty 6-lever brass mortice door locks and handle sets, (93) assembling factory-made rigid foam pvc door frames reinforced with internal steel tubes, (94) hanging 30 mm thick plain or pre-laminated plain pvc panel door shutters, (95) fixing fire-retardant glass fibre reinforced plastic door frames packed with timber inserts, (96) hanging 30 mm fire-retardant monolithic hollow frp panel door shutters, (97) fabricating collapsible steel security gates using vertical channels and flat diagonals, (98) pouring reinforced cement concrete (mix 1:1.5:3 or 1:2:4) below plinth levels, (99) pouring reinforced concrete walls, columns, and pillars up to floor v, (100) casting reinforced beams, suspended floors, landings, and lintels up to floor v, (101) casting reinforced cement concrete access steps and kerbs up to floor v, (102) casting reinforced concrete arches, domes, vaults, or sloped roofs exceeding 15, (103) setting up slab formwork shuttering for access platforms and suspended roofs, (104) erecting beam formwork shuttering for structural girders, cantilevers, and lintels, (105) putting up step profile shuttering for concrete staircases, (106) molding small concrete lintels under a 1.5m span, window sills, and copings, (107) pouring machine-batched, pumped m-25 design-mix concrete below plinth, (108) pouring pumped m-25 design-mix concrete above plinth up to floor v, (109) casting machine-mixed m-30 grade heavy design concrete below plinth, (110) casting machine-mixed m-30 design concrete above plinth up to floor v, (111) hoisting and setting precast rcc lintels and beams using 1:3 mortar, (112) placing precast rcc shelves finished with neat cement punning over exposed faces, (113) cutting, bending, and tying tmt steel reinforcing bars below plinth, (114) cutting, bending, and tying tmt steel reinforcing bars above plinth level, (115) accounting for extra cement quintals added over design-mix criteria, (116) installing 2mm uv-stabilized corrugated fiberglass roof covers, (117) installing 90 cm wide zinc-coated plain galvanised steel roof valley flashing, (118) fixing 75mm or 110mm unplasticised rigid pvc downpipes with seal rings, (119) installing 15 cm wide semi-circular plain g.s. sheet gutters on iron brackets, (120) installing large semi-circular pvc eaves gutters from 110mm up to 300mm diameter, (121) building false ceilings with pvc panelled sheets over aluminium square grids, (122) applying a 6 mm fine layer of 1:3 cement plaster over walls or slabs, (123) applying a 6mm plaster coat topped with lime wash for slab bearings, (124) applying a 12 mm base layer of 1:4 cement sand plaster over masonry, (125) applying a thick 20 mm layer of 1:4 cement sand plaster over rough backings, (126) finishing 12 mm thick plaster with a floating coat of neat cement slurry, (127) blending manufacturer-approved waterproofing compounds per kg of cement used, (128) executing neat flush or ruled pointing over stone masonry faces using 1:3 mortar, (129) laying 40mm thick 1:2:4 cement concrete flooring with a cement float finish, (130) laying 52mm hardener flooring with a 40mm base and 12mm topping layer, (131) laying 62mm hardener flooring with a 50mm base and 12mm topping layer, (132) laying standard colored or white 300x300mm ceramic glazed floor tiles, (133) laying 300x300mm or larger rectified glazed ceramic floor tiles, (134) laying vitrified floor tiles from 500x500mm up to 1000x1000mm on mortar beds, (135) laying large vitrified tiles using polymer-modified quick-set adhesives, (136) fixing first-quality ceramic glazed tiles over steps, risers, and dados, (137) installing vitrified riser skirting over stairs and room perimeters using mortar, (138) installing vitrified wall skirting using modified quick-set adhesives, (139) mechanical mirror polishing over mosaic, marble, or granite floor works, (140) applying two coats of dry distemper over water-thinnable wall primers, (141) painting internal walls with two coats of washable oil-bound distemper, (142) coating wall faces with ready-mixed first-quality acrylic distemper, (143) painting walls using eco-friendly low-voc acrylic distemper coats, (144) applying premium low-voc acrylic emulsion coatings on inner walls, (145) applying a single foundational coat of water-thinnable cement primer, (146) applying two coats of weatherproofing cement paint over fresh outer walls, (147) re-coating old exterior walls with weatherproofing paint over primers, (148) finishing facades with smooth exterior acrylic paint over primers, (149) painting soft or hard timber frames with ready-mixed pink or grey primers, (150) applying protective aluminum primer over resinous wood and plywood boards, (151) painting iron works with red oxide zinc chromate corrosion primers, (152) coating g.s. roof sheets with synthetic enamel paint over primers, (153) applying gloss synthetic enamel paint over new metal or timber works, (154) coating industrial metal structures with heavy-duty aluminum paint, (155) applying protective anti-corrosive black bitumastic paint over old works, (156) applying hot double coats of coal tar over structural wood or utility poles, (157) burying or surface-mounting 63mm to 160mm drainage pvc pipelines, (158) fitting orissa-pattern vitreous squatting pans with 10l pvc flushing cisterns, (159) fixing long-pattern 580mm white vitreous china squatting pans, (160) mounting flat-back china urinal basins equipped with 5l automatic flush tanks, (161) installing pedestal-type european washdown water closet pans, (162) fitting european closets with solid plastic seats, lids, and low-level cisterns, (163) mounting flat-back, angle-back, or large vitreous wash basins with cp taps, (164) running class-5 water lines from 20mm up to 63mm concealed or across walls, (165) running exposed hot/cold water supply lines using stable cpvc pipes, (166) chasing walls, running concealed water lines, and plastering them smooth, (167) trenching, laying, and backfilling external cpvc water supply pipe mains, (168) fixing exposed internal water lines using rigid galvanised iron nominal bore pipes, (169) embedding g.i. pipes inside wall chases with bitumastic anti-corrosive insulation, (170) trenching, jointing, and burying g.i. nominal bore pipelines underground, (171) cutting, threading, and tee-jointing new distribution loops into active g.i. mains, (172) inline cutting and fitting flow water meters and isolation stopcocks, (173) installing chromium-plated heavy brass taps weighing a minimum of 400g, (174) fixing high-grade framed glass mirrors in oval, circular, or rectangular styles, (175) mounting lightweight ptmt synthetic towel rails with concealed wall brackets, (176) screwing in heavy-pattern 15mm or 20mm nominal bore brass bib cocks, (177) replacing old or fixing new 23 kg light-duty rectangular cast iron manhole covers, (178) installing 110mm multi-inlet pvc floor traps with a 50mm deep water seal, (179) erecting syntex or equivalent high-density polyethylene fresh-water storage tanks, (180) welding, priming, and fixing steel bars, window grates, ladders, and railings, (181) installing pre-coated galvanised steel roof flashings and aprons up to 600 mm, (182) pressure grouting porous joints in rough stone structures with 1:3 mortar, (183) laying m15 grade precast concrete paving blocks including mortar pointing and curing, (184) painting traffic islands and road kerbs with yellow, black, and white enamel, (185) recanning office chair seats and backrests using premium plastic cane on site, (186) sealing roof bolt projections using waterproofing bitumastic compounds, (187) laying plastic felt rolls and roofing compounds across central valley gutters, (188) mounting specialized sanitary valves, bib taps, angle cocks, and connections, (189) replacing broken 100mm to 300mm asbestos cement fluid conduits, (190) replacing old 80mm to 200mm high-density polyethylene pipeline tracks, (191) wrapping leaking pipelines tightly with heavy-duty structural m.s. clamps, (192) operating pump sets on daily hire for structural trench dewatering, (193) replacing weathered epdm u-rubber seals on sliding aluminum windows, (194) supplying and installing pre-molded steel-mesh ferrocement septic tanks, (195) ramming broken stone fragments into voids along aging dry rubble sea walls, (196) manufacturing and installing powder-coated wire-mesh window insect screens, (197) manufacturing and installing heavy aluminum frame wire-mesh fly doors, (198) fabricating post-mounted 15"x18" vinyl-printed directional signboards, (199) fabricating large 4'x2' reflective letter vinyl-pasted roadway signage boards, (200) erecting 6'x4' large vinyl public health hoardings over twin anchor posts, (201) desilting tidal gauge water passages and clearing debris from canteen roofs, (202) sealing sheet ridges using specialized superplast strips, (203) polishing stained marble floor surfaces using oxalic acid and mansion floor wax, (204) deep cleaning old glazed wall tiles with oxalic acid solutions to restore brightness, (205) fitting 1-inch horizontal internal aluminium venetian solar window blinds, (206) cutting down hazardous, tall coconut trees and clearing logs from site grounds, (207) laying structural eurocone tiles over old concrete floor beds, (208) running lines of tensioned steel barbed wire over boundary posts, (209) shaping, splitting, drilling, and setting up bottom-bent angle iron fencing posts, (210) spreading heavy waterproof tar felt blankets across leaky valley flashings, (211) erecting post-anchored 3'x2' vinyl safety boards displaying the port logo, (212) adjusting modular grids and re-laying salvaged ceiling tiles, (213) installing suspended calcium silicate panels over galvanized grids, (214) gluing cat-eye road stud reflectors onto asphalt pavements, (215) setting up satin curtains over aluminum c-channels, (216) building standalone outer framing profiles to receive mosquito screens, and ends with (217) unflanging and dismantling 14"/9" large water meters for mechanical repairs.
supply installation for comprehensive annual maintenance contract camc for lab animal facility in csir iict - a. comprehensive hvac & mechanical maintenance the contract covers all equipment parts, man power on shift basis, and consumables for: chillers (24 & 100tr):the contractor shall undertake comprehensive, proactive, and corrective maintenance of the 24 tr and 100 tr chiller units to ensure continuous operation. this includes the immediate repair or replacement of critical components including, but not limited to, scroll compressors, condenser fan motors, printed circuit boards (pcbs), and communication modules. scope of work further encompasses routine refrigeration leak detection and immediate rectification, refrigerant top-ups, and the chemical descaling of condenser/evaporator coils whenever necessary to maintain optimal heat transfer efficiency. all other wiring, sensors and communications issues needs to be addresses by the contractor and keep the units fully operational all the time. air handling units (ahu):the contractor shall maintain all single-skin and double-skin ahu units in a flawless operational state. this includes the repair or complete replacement of damaged ahu cooling/heating coils, drive belts, pulleys, and fan alignments. comprehensive maintenance extends to the integrated control systems, specifically including the variable frequency drives (vfds) fault programming, parameter tuning, thermistors, and heater bank control optimization along with all necessary rectifications to keep the ahus fully functional. filtration & air quality:the contractor shall perform regular, scheduled cleaning of all pre-filters, fine filters, and hepa filters to maintain specified air changes and pressure cascades. all pre, fine, and hepa filters shall be completely replaced either at the commencement or at the conclusion of the annual maintenance contract (amc) period. the exact timing of these replacements shall be determined based on actual filter condition metrics (such as differential pressure drop) at the start of the amc, or as per the direct recommendation and instructions of the in-charge of the animal house or the designated engineer. regular cleaning activity has to be performed as per the schedule and should be documented in log sheets. pumping systems:maintenance of all centrifugal pumps to guarantee uninterrupted cooling water circulation. in the case of unserviceable wear or catastrophic failure, the complete replacement of the pumps and motor units. scope of work includes all component-level repairs and replacements, including but not limited to, bearing replacements, mechanical seal replacements, impeller overhauls, shaft sleeve replacements, and coupling renewals. additionally, the contractor shall be fully responsible for complete electric motor rewinding, shaft alignment, vibration dampening, and all necessary structural, mechanical, or electrical rectifications required to keep the pumping systems continuously operational. all component replacements must utilize genuine oem parts, and all activities must be documented through maintenance logs. plumbing:immediate containment and rectification of all chilled water pipeline leaks. this includes the repair, insulation restoration, and complete replacement of faulty plumbing line, including non-return valves (nrvs), gate valves, butterfly valves, and motorized 3-way modulating valves. b. specialized lab equipment & facility systems autoclaves & cage washers: comprehensive preventive and predictive maintenance of the autoclave system and its complete specialized components, ensuring 100% operational readiness and safety at all times. this includes the routine inspection, calibration, and timely replacement of critical heating elements, temperature/pressure sensors, pneumatic piston valves, safety pressure switches, high-temperature door gaskets, and feed-water pumps. all diagnostic checks, component rectifications, and parts replacements must be executed in accordance with oem/oem authorized approved technical directives to prevent pressure vessel failures or cycle aborts. it is the absolute responsibility of the contractor to carry out all necessary repairs to keep both the primary autoclave unit and its critical accessories including water lines, and steam traps in a fully operational state. all maintenance activities, and component replacements must be documented through maintenance logs. clean room accessories: rectification of air showers, pass boxes, and garment cubicles, including magnetic door interlocks, uv/cfl lighting, blowers and related wiring and push buttons and replacing the spares if required. compressed air: immediate repair or complete replacement of the air compressor system, its auxiliary equipment, and associated airline in the event of any operational malfunction or critical mechanical failure. to minimize system downtime, the contractor must execute all emergency rectifications. this includes the immediate restoration or replacement of the compressor, motor assembly, pressure switches, regulators, and filtration units to return the compressed air system to its full original working capacity. c. electrical, automation and parameter monitoring: power systems: maintenance of electrical panels related to chiller, ahus and all other equipment attached in annexure, diesel generators (dg) and related amf panel and all necessary rectifications/repairs to keep the dg and amf panel operational. the contractor shall undertake comprehensive, proactive, and corrective maintenance of all electrical panels associated with the chillers, air handling units (ahus), and all other auxiliary equipment detailed in the attached annexure, ensuring continuous operational reliability and safety compliance. all maintenance, component repairs, and part replacements must be executed in accordance with the original equipment manufacturer (oem) approved schedules and technical directives. for the dg sets, this includes but is not limited tothe mandatory execution of standard "b-check, the timely replacement of lube oil filters, fuel filters, and air filters. for the electrical amf panels, maintenance shall adhere to oem testing schedules, including the testing of sensing relays, breaker servicing, and dc control circuit. all maintenance activities must be documented through maintenance logs. bms & monitoring: maintenance of the building management system (bms) software, direct digital control (ddc) panels, differential pressure (dp) sensors, temperature/pressure gauges, motorized volume control dampers (vcds), and all field devices to ensure uninterrupted operations. all hardware maintenance, and component rectifications must be executed. this includes the periodic checking of of all sensors and gauges, motorized vcd actuator modulation, and checking the communication health of ddc panel networks. in the event of a malfunction, corruption, or total crash of the bms software, it shall be the sole responsibility of the contractor to immediately restore the software, databases, and graphics to their original, fully functional working form. access and cctv: all rectification/replacement of biometric access readers and cameras and related accessories like switch and cables to keep them operational. all digital t& rh meters and displays has to be calibrated including replacing the batteries and if required replacing with new t&rh meters. d. environmental monitoring & compliance the contractor must maintain the following parameters strictly: temperature: 20c 26c. relative humidity: 50% 70%. differential pressure :> 20 pascal. lighting: 350 400 lux (on a 12h light / 12h dark photoperiod). sound:< 85 db. testing: quarterly measurement of air changes per hour (ach), light intensity, and sound levels (db) using the own calibrated equipment and submission of reports to the concerned scientist/engineer in charge. e. preventive maintenance & schedules frequency: minimum of four (4) comprehensive services per year, with one mandatory service performed before the summer season. documentation: detailed logbooks must be maintained for daily, weekly, monthly, and quarterly parameters and duly verified by scientist/engineer in charge. hard copies of preventive maintenance (pm) certificates and service reports must be submitted to the scientist/engineer in-charge after every service. critical spares: to ensure rapid recovery, the contractor shall keep one spare compressor (or the pre ordered copy) of each capacity for the duration of the contract. f. contractor responsibilities tools & equipment: all tools, ladders, and manual assistance must be provided by the contractor, if any tools or equipment used within the iict, returning the same in its original form without any damage is mandatory, if not the same will be charged from the contractors final bill. logistics: transportation for technicians and the movement of equipment to/from workshops is the contractor's responsibility. workmanship: any damage caused by mishandling or poor workmanship shall be repaired by the contractor at no additional cost to csir-iict. day-to-day operations: all day-to-day operations, maintenance of animal house equipment that include, o monitoring of all chillers, ahus, autoclave and related critical equipment on daily basis and rectifying any issues on priority basis. o maintaining checklists in the shift of critical equipment i.e chillers, pumps, ahus, autoclave and air showers. o cleaning of filters (related to ahus, veus, air showers, garment cubicles) as per schedule. o all other engineering related activities of the facility as and when suggested by scientist/engineer in-charge. the contractor should undertake to operate above equipment by providing the manpower in 2 shifts (8 hours in 2 shifts in a day x 7 days in week x 365 days). the normal operating hours should be from 6.00 am to 2.00 pm for first shift and 2.00 pm to 10.00 pm for second shift. over all, day-to-day, maintenance for trouble free operation of all the items covered in scope of works mentioned in annexure - ii. the manpower provided in shifts should be available onsite during the whole shift period. all the equipment as per annexure - ii should be maintained properly and data shall be logged in the logbook as per standard procedure by monitoring of daily. the log books will be cross checked by animal house in charge/iict engineer at any time. contractor should attend and solve the issues including all normal breakdowns if any within 4 hours of identification or keeping the standby units for normal functioning. priority should be given for maintaining the animal rooms environmental variables such as temperature (20-26c), relative humidity (50-70%), lighting (350 to 400lux), sound (less than 85db) and differential pressure in animal room (20pascal) within the limit without any deviation for more than 6 hours. routine photo period check by automatic lighting 12 hours dark and 12 hours night should be maintained in all animal rooms. light, sound and air changes per hour for all rooms in animal facility should be measured every 3 months once by the equipment of contractor. check and render calibration and preventive maintenance service to all the equipment and its accessories every 3 months. the contractor should carry out all minor modifications required to suit our needs. the contractor shall carry out any minor rectification in the equipment. comprehensive maintenance contract should include daily schedules and monthly schedules for filters cleaning by maintaining proper log books with signatures. replacement of parts/components/subassemblies shall be carried out as and when required. ac technicians/operators should have minimum iti/diploma certificate with minimum 1- year experience in o&m of hvac system and having support/helping experience in electro mechanical installations/hvac system. the manpower needed for execution of o&m should be provided by the contractor. no manpower will be provided by csir-iict. the contractor shall comply with the provisions of the payment of wages act, 1936, minimum wages act, 1948, employees liability act, 1938, workmen's compensation act 1923, industrial disputes act, 1947, maternity benefits act 1961 and the contractor's labour (regulation and abolition) act 1970, or the modifications thereof or any other laws relating thereto and the rules made there under from time to time.
procurement, fabrication and transportation of alumunium door and windows on works contract basis for our "combined station works of mechanical, civil, electrical and instrumentation works and other facilities under kandla-gorakhpur liquefied petroleum gas (lpg) pipeline project of indian oil corporation limited on behalf of ihb limited at bina in madhya pradesh state
jobs of capital repair of sinter plant band-i,ii&iii(jobs of single roll crusher). miscellaneous structural repair / welding & changing of rotor of srcof sinter plant band-1,2&3 during shut down & cladding of gas lines& repair of goggle plate & rep/rev of blt g/box etc in bfs. repair of hmtc during campaign repair/shutdown of hmtc in sms ii. maintenance of running mechanical equipments and structures of sinter plant, csp (co & cc) and rmp during shut down and capital repair. mechanical maintenance of highpressure steam, air, water and oil line networks covering valves, pipelines, compensators, flange joints etc and thermal insulation in tbs. technical assistance in oven pushing in coke oven batteries. mechanical maintenance of conveyor belts, ivs and dust conveying systems of rmp. skid pipe changing and arresting leakage of outlet and inlet pipe joints of skid of rhf- 2,3 & 4 of hsm.
supply of - wheel bearing front tata xenon , assembley tie rod indicator , top indicator light , gasket sheet , shellock anabond , nuts and bolts , screw , fog lamp assembly , fog lamp bulb , roof lamp , fuse glass , temperature sensor sml , gauge fuel tank sml , spark plug tvs , split pin , washer plain , washer spring , diesel pipeline with banjo , oil seal front axle tata 709 , oil seal rear sml , seal oil rear axle sml , oil seal axle shaft maruti gypsy , oil seal front axle maruti gypsy , locking coller glove bos mahindra scorpio , regulator assy lh maruti gypsy , assembly gear shift lever complete tata 709ex , ball joint steering drag tata xenon - mt spares | quantity - 307
Full bid documentation — prepared by AI in minutes
supply of design, supply and installation of various items related to lpg gas pipeline,bhatti point, 4 ba nk manifold, oil meter gauge, ball valve used master, psi regulator high pressure, psi regulator low pressu re, gas detector with installation make victory or similar, isi marked pipe, fitting (elbow, t & socket),4 feet pipe in 1*1/2 feet, steel cage for cylinders with fiber roof, painting charge for rust protection, freight, labo ur & fitting charge etc. for running room ldh. [ warranty period: 30 months after the date of delivery ] ]
1) work of removal of sludge, silt and cleaning of one-day reservoir tank during coh at unit-7, civil plant tps, parli v., 2) procurement of 27.5 vimt air pre-heater internal spares required at bm-2, 250 mw, tps, parli v., 3) procurement of spares for ndct hot water distribution system during unit-7 coh at tm-1, 250 mw, tps, parli v., 4) procurement of various spare parts and services for 5 ton eot crane at ahp-1, tps, parli v., 5) procurement of submersible dewatering pump at tm-1, 250 mw, tps, parli v., 6) procurement of walber feeder drive and non-drive bars installed at chp-1, 250 mw, tps, parli v., 7) procurement of flexible control cable at chp-2, 250 mw, tps, parli v., 8) supply and installation of oil coolers assembly for crusher house power pack system at chp-2, 250 mw, tps, parli v., 9) procurement of various oil gun and assembly spares required at bm-2, 250 mw, tps, parli v., 10) annual contract for periodical cleaning of overhead drinking/servicing water tanks at os-2, 250 mw, tps, parli v., 11) procurement of flexible disc coupling for boiler feed pumps (motor to booster pump) at tm-2, 250 mw, tps, parli v., 12) two-year annual work contract for environmental monitoring by mobile monitoring van in surrounding locations up to 20 km radius, surrounding sensitive locations for relevant aaq parameters at wtp-1, 250 mw, tps, parli v., 13) procurement of 1500 class flange for soot blower steam line at bm-1, 250 mw, tps, parli v., 14) supply of junkshaft tensioning mechanism assembly and tensioning stud for impactor crusher installed at chp-1, 250 mw, tps, parli v., 15) annual maintenance of water supply pipeline works in unit-6 & 7 at civil plant tps, parli v., 16) amc for work of btl attending and radiography during short shutdown at bm-2, 250 mw, tps, parli v., 17) procurement of lt and ht cable jointing kits required at em-2 and em colony, 250 mw, tps, parli v., 18) supply of bunker house grill at chp-2, 250 mw, tps, parli v., 19) procurement of aqueous film forming compound (afff) for fs, tps, parli v., 20) procurement of bag filter for esp & silo at ahp-1, tps, parli v., 21) supply of co2 gas cylinders at os-6, 7 and 8, 250 mw, tps, parli v. (marathi image)
notice inviting tender(nit) for procurement, fabrication and transportation of alumunium door and windows on works contract basis for our "combined station works of mechanical, civil, electrical and instrumentation works and other facilities under kandla-gorakhpur liquefied petroleum gas (lpg) pipeline project of indian oil corporation limited on behalf of ihb limited at bina in madhya pradesh state.
operation and maintenance of mep installations for atr chitradurga bengaluru - deploying manpower for operation and maintenance of e&m installations of internal and external electrification, dg sets, eot cranes, air conditioners, water supply, water treatment plants, sewage treatment plants, fire alarm, fire fighting systems, water coolers with water purifiers, runway lighting, area & perimeter lighting at varavinakaval, atr & "providing 'b' check of dg sets upto the time of 300 hrs / 6 months whichever comes earlier with the activity like changing of fuel filter, lube oil filter, separator, fuel water, premix coolant, engine oil, corrosion inhibitor, crn resistor, gasket cover etc by the authorised service agency of the manufacturer and testing there of as directed by the engineer-in-charge for following dg, sets. (make- cummins)", a) 750 kva, 11 kv dg sets (cummins model: kta-38-g10), a) 200 kva, 440v dg set (cummins model: qsb-67-g12) b check, b) 62.5 kva, 415v dg set(cummins model: 4btaa3.3-g11), c) 30 kva, 415v dg set(cummins model: x2.7taa-g2), d) 85 bhp diesel engine driven fire pump (kirloskar 4r1040t), providing 'c' check -of dg sets upto the time of 1500 hrs / one (01) year whichever comes, a) 750 kva, 11 kv dg sets (cummins model: kta-38-g10), b) 200 kva, 440v dg set (cummins model: qsb-67-g12) c check, c) 62.5 kva, 415v dg set(cummins model: 4btaa3.3-g11), d) 30 kva, 415v dg set(cummins model: x2.7taa-g2), d) 85 bhp diesel engine driven fire pump (kirloskar 4r1040t), "testing of oil, dehydration and filtration of step down (33/11kv and 11/0.415 kv) transformer oil for various capacity of transformers on running condition of transformer and dielectric strength not less than 60 kv in 2.5 mm gap (rms), complete all as specified and directed by engineer-in-charge for following transformers., note :-, (i) dehydration and filtration shall be carried out by licensed agency at site by bringing filtration machine., (ii) testing of oil shall be carried out before filtration and after filtration of insulating oil.", a) 250 kva tranformer(300 ltr) each 1, b) 250 kva tranformer(340 ltr) each 1, c) avr ht unit(600 ltr) each 1, d) avr regulator unit(300 ltr) each 1, e) 750 kva transformer(940 ltr) including oltc(210 litres) each 2, f) 630 kva transformer(1050 ltr) including oltc ( 210 litres) each 1, g) 160 kva transformer(230 ltr) each 1, h) 100 kva transformer(275 ltr) each 1, j) 63 kva transformer(245 ltr) each 2, calibration,maintainanceandservicingofvcbsandacbs, "maintenance and complete servicing of 11 kv vcb panel indoor/outdoor type) including de-assembling of operating mechanism parts, well cleaning with petrol crc 226, removal of old grease and re-greasing the same with recommended grease, check condition of sic contacts, checking condition and alignment of jaw contact, checking and proper tightening of hardware, checking proper closing of all poles together, checking of breaker tripping through push button, checking and adjusting gap between hylam sheet and side plate, checking motor operation in case of edo, checking of auxiliary contacts continuity proper change over, checking presence of all circlips, checking ir between phase phase (vcb closed condition), checking ir between phase earth (vcb closed condition), checking ir between phase earth (vcb in open condition), replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc oiling and greasing of moving parts, re- assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including, testing, tripping check of ht vcbs making perfect operation in manual and electric mode including maintenance and well cleaning the complete panel board bus bars, de-carbonizing all joints, bus bar, cts metal parts etc complete all by authorized service agency/oem as directed by engr-in-charge., (make- )", "servicing of 11kv sfu by authorized agency of oem/agency having valid license issued by, state/central electricity authorities etc. for similar type of works", "servicing of 11kv vcb along with carrying out calibration of all type of digital and analog relays, multimeters, voltmeters, ammeters, current and potential transformers by authorized agency of oem/agency having valid license issued by state/central electricity authorities etc. for similar type of, works", a) 800a vcbs (siemens)- 14 nos, b) 800a vcbs (crompton) 3 nos, amc and preventive maintenance of acbs 440v acbs (l&t) 13 nos, amcforeotcranes, annual maintenance contract (amc) of following eot cranes at site including repairs and periodical check to all components, greasing/lubrication to all movable parts, adjustment of rail track line of crane, rectification of flexible cable with cable carrier, replacement of pvc cable carriers, rectification/tightening of all electrical connections at electrical panels and connected electrical drive motors, checking and rectification of brake system, checking of gear oil, replacement of gasket, oil seal and required nut and bolts checking, rectification of portable/pendent control panel and checking/ rectification of cranes light points for smooth functioning as required (cleaning and dusting of all components once in every month complete all as directed by engineer-in-charge)., "service engineer will visit once every 3 months for verifying the health of cranes & hoists and will do necessary maintenance as per terms and conditions in contract., the servicing of cranes should be carried out through oem/rankcranes/pedvakcranes/elmech, cranes/tojymsteelproducts / vinaycranes/vipracranesengineeringpvtltdoranyother agencyapprovedbydepartment", "note: - major spares parts which are not part of the item will be repaired/replaced on chargeable basis. payment shall be paid on actual procurment basis. original paid voucher, must be submitted to dept.", (i) eot crane 5 ton capacity -sl no-1, (ii) eot crane 5 ton capacity sl no-2, "conducting load test of eot and hot cranes given below including arrangement of slings, dee shackles, fasteners, transportation of load and all other acessories etc. complete and as directed by engineer-in- charge. the load test shall be carried out once in a year by autorised service agency or as per direction of engineer-in-charge., note: loads are available at site and contractor can use for load testing.", eot crane 5 ton capacity - sl no-1, eot crane 5 ton capacity - sl no-2, "inspection by any eot crane manufacturer as and when required during the brake down of 5 ton capacity eot crane which-includes one engineer duly carring over inspection of the crane i.e all electrical & mechanical items, running the crane and testing the components, preparation of inspection report. the cost should include all expenses including travelling, local conveyance, lodging and boarding charges. approval of crane manufacturer to be taken from department before, execution", amcforfirefightingsystem, "annual maintenance contract (amc) for fire fighting systems as per job detailed scope of work indicated as per annexure as applicable including b-check and c-check of fuel injection pumpset 01 no. including servicing and maintenance of main fire pump - 01 no. and jockey pumps - 02 nos, dismantling from site and transporting to workshop for carryout servicing and replacement of unserviceable spares and taken back the same after maintenance services and refixing etc all complete by authorised service agency and as directed by engineer in-charge., the oem/authorised specialist shall inspect quarterly starting 1st week of commencement of contract., the amc includes all accessories but not limited to sprinklers, pumps, pipelines, nozzles, electrical operating pumps, diesel engine pumps, jockey pump and all other items available in the given fire fighting system, note: - replacement of unsv spares if any, which are not a part of amc and the same are not in boq will be measured and paid separately under prime cost., make:kirloskarcareortheirdealersoranyotheragencyapprovedbydepartment", comprehensive annual maintenance contract (camc), water coolers (camc), "comprehensive annual maintenance contract (camc) of water cooler including consumables, checking and periodic maintenance of compressor, motor, condenser, expansion valve, evaporator coils etc and also repair/replacement of unsv spare parts icluding charging of gas, supply of consumables etc complete by oem/authorised service agency/agency approved by department and as directed by engineer-in-charge. the specialist shall inspect quarterly starting 1st week of commencement of contract., make:voltas/kentortheirdealersoranyotheragencyapprovedbydepartment, the scope also includes sediment filter, low pressure switch,activated carbon filter solenoid valve, booster pump, pump head tds control valve,ro membrane shf , flow restrictor tube, uf membrane non return valve high pressure switch, smps, auto flush pcb , wire harness , tubing- and all other items available in the given water coolers and purifiers.", "1)camc for water cooler including consumables and other requirements as mentioned above with, ro water purifier", 2) camc for water cooler with ro water purifier including consumables and other requirements as mentioned above make of water cooler: voltas, 20/40litres cooling/stotare capacity -6 nos of water purifier: kent excel+ -6 nos, 3)camc for water cooler with ro water purifier including consumables and other requirements as mentioned above make of water cooler: usha, 20/40litres cooling/storage capacity -2 nos make of water purifier: eureka forbes, dr. ag classic -2 nos, camc for hvac, "camc of following ductable, vrf, split, cassette & split type air conditioner (before quoting the authorised oem shall visit the site. nothing extra shall be paid), make:voltas/bluestar/hitachi/carrieroranyotheragencyapprovedbydepartment", comprehensive annual maintenance contract (camc) of air conditioning split/ cassette/ ductable/ package/ condensing unit including, cleaning/replacement of filter, checking operation of the controls such as selector switch, thermostat, relays and remote controls etc, checking air flow through the supply air grill, return air grill, condenser, checking operation of voltage stabilizer and back up electrical power outlet/mcb, checking operation of the drive motor and fans, checking air temperature at supply air grill, return air grill, inlet air condenser and outlet air from the condenser, checking of condenser coil/compressor/evaporator or cooling coil/evaporator fan/heating element/expansion valve, ahu, heating pump, calorifier etc. and replacement of all defective components, charging of refrigerant gas, including testing etc complete by oem/authorised service agency and as directed by engineer-in-charge. the specialist shall inspect quarterly starting 1st week of commencement of contract., "comprehensive annual maintenance contract (camc) of following capacity vrf air conditioning system including checking / setting / rectification of all safety and automatic controls, complete overhauling of indoor/outdoor units, fcu, fans, maintenance of exhaust air fans and their balancing, if required. observe the operation of all the dampers and make necessary adjustment in linkage and blade orientation for proper operation, functional checks & calibration of all switches, thermostats, humidistat and other instruments rectification of the same if required, to check the safety controls mechanical, electrical/ electronics and inter-locking of the various equipments, to check all piping/ insulation/ proper positioning/ damage and rectifying the same where ever required, check the performance of equipment of vrf plant for proper functioning, checking of heat recovery system/heat pump, gas charging in vrf system, and replacement of all unsv spares/consumables, descaling of consenser or any other job required to be attended during course of checking / as per oem to keep the plant inperfectly working conditions etc complete all as specified and directed by engineer-in-charge. the oem /authorised agency shall inspect quarterly starting 1st week of commencement of contract., the camc includes all accessories but not limited to outdoors units, refrigerant piping, refrigerant circuit, oil balancing/ equalizing circuit, weatherproof isolation switch., ahu, hot water generator, pumps and all other equipment available in the hvac system.", model nos of pcbs are also included in the rate., "pcb for 1.5 tr indoor unit of inverter ac(blue star model: cnhw18cafi)/voltas model: 183vey/, hitachi model: rsn317hcea", "pcb for 1.5 tr outdoor unit of inverter ac(blue star model: cnhw18cafi)/voltas model:, 183vey/ hitachi model: rsn317hcea", "pcb for 2 tr indoor unit of inverter ac (blue star model: cnhw24cafi/voltas model:, 243vey/voltas model : eu243v szs/ hitachi model: rmos424hcea", "pcb for 2 tr outdoor unit of inverter ac (blue star model: cnhw24cafi/voltas model:, 243vey/voltas model : eu243v szs/ hitachi model: rmos424hcea", pcb for 3tr indoor unit of blue star ac(model: sc365gi/36cya), pcb for 5.5 tr indoor unit of blue star ductable ac(model: dsa661r1), pcb for 8.5 tr indoor unit of blue star ductable ac(model: dsa1021r1), pcb for 11 tr indoor unit of blue star ductable ac(model: dsa1321r1), a) 11.tr ductable air conditioners (blue star) -9 nos, b) 8.5 tr ductable air conditioners (blue star make installed in the year 2016) -3 nos, c) 5.5 tr ductable air conditioners (blue star make installed in the year 2016) -4 nos, "d) 3.0 tr cassette type ac (blue star make installed in the year 2016) blue star-07 voltas-03. -, 10 nos", e) 2.0 tr wall mounted split type ac (blue star make installed in the year 2016) 107, f)1.5 tr wall mounted split type ac (blue star make installed in the year 2016) 142, fire alarm (camc), "comprehensive annual maintenance contract (camc) for following fire alarm system quarterly one, visit ( 4 visits per annum) which includes fire alarm panel housing cleaning, internal pcb cleaning,", "microprocessor based analogue addressable type (ul/en approved) 640 character fire control panel with zonal indications, zener barriers, two way media convertors, required patch cords and signal booster for network connectivity with of cable and with battery power pack as per, specifications (including all following items)", single loop with loop cards & above mentioned accessories - 5 nos, two loop with loop cards & above mentioned accessories - 1 nos, "twisted pair 1.5sq.mm shielded fr insulated copper conductor flexible wire in the existing pvc, conduit. - 6223 rmt", "analogue addressable type multi sensor (smoke/heat) photo electric detectors with base and led, indication lamp along with all fixing accessories. - 355 nos", response indicators with led indication lamp along with all fixing accessories. - 87 nos, analogue addressable loop sounders along with all fixing accessories. - 33 nos, "analogue addressable type monitor modules (notifier, fmm-101) along with all fixing accessories. -, 1 no", fault isolators along with all fixing accessories. - 28 nos, addressable control modules along with all fixing accessories. - 1 no, "analogue addressable ordinary manual call points with push type along with all fixing accessories., - 33 nos", "weather proof type analogue addressable manual call points with glass and hammer on stand post made out of 1500mm long 50x50x6mm galvanised channel fixed in ground with concrete coping as, required - 8 nos", "8 way wago / phonix terminal connector in weather proof ms junction box including painting and, all 'installation materials etc as required.", "2.5 km range siren with weather proof motor with 220v 50hz ac supply operation with required power contactor, mpcb for control all in a weather proof enclosure near motor including all, installation materials as required - 5 nos", "intelligent addressable network control active repeater panel with network module media converter, patch cords and signal booster for network connectivity with of cables on facp network configuration to monitor and control all local fire alarm control panels located in individual buildings built in buzzer and rs 485 port on cpu board with optional network software connectivity, fire/ fault indicators, audio visual signals, backup battery, battery charger, central processing unit 640, character display unit complete in all respects. - 1 nos", "reflective type self aligning motorized beam detector , receiver remote led status indicator, sensitivity measurement filters and other mounting accessories with addressable monitor modules, etc along with all fixing accessories. - 4 nos", "identification of fault in fo cable including hiring of machinery for cable fault locator, cable jointer,, earth removal and repairs & replacement of required accessories.", alcms (camc) for runway lighting and equipment's, "comprehensive annual maintenance contract (camc) preventive and breakdown maintenance of alcms by trouble shooting, repairing of control cards & alcms systems by replacement of defective components such as touch screen, plcs, computers, ups, batteries, associated components & required software etc., providing complete support to keep system in working condition & submitting the reports. (total system camc shall be carried out as per following items). the following items shall be part of this scope of work. any item, part or service which is missing here will also be included in this scope of work irrespective of quantities., contractortovisitsitebeforequoting., make:nasusystems", supply of logic controller for alcms systems, supply of output module for alcms systems., supply of input module for alcms systems., supply of network adapter switch -, supply of alcms interface module for ccr, supply of alcms interface module for fixed circuit., supply of power supply for alcms, supply of battery for ups, supply of ups for alcms, supply of software license for alcms, supply of windows operating system, "comprehensive annual maintenance contract (camc), preventive & breakdown maintenance of nasu make following ccrs i/c repairing of defective ccrs by identifying the fault, repairing of defective pcb's and other components and service the same, i/c calibration of ccrs and complete checking, servicing & submitting the reports etc. as required. (all the components required for servicing & repairing of ccrs will be supplied by the contractor. all the components required for servicing and repairing of ccrs will be in scope of work., a)5kw ccr - 8 nos, b)7.5kw ccr - 6 nos, c)15kw ccr - 2 nos, the following items shall be part of this scope of work. any item, part or sevice which is missing here will also be included in this scope of work irrespective of quantities., contractortovisitsitebeforequoting.", supply of spare control card for nasu make 4 kw to 15 kw mpccr:, microprocessor main control card, display card, power supply + driver card -, insulation monitor card, ttm card -1 no, input pt -1 no, supply of plug in type relays 24 vdc -1 no, supply of plug in type relays 240 vdc -1 no, supply of ti 300 trip indication fuses -1 no, high speed semi-conductor protection fuses :, a) gs 1000/100, b) gsb 50, c)80 et, thyristors :, a) 150 rk160, b) 85 rk 160, c) 65 rk 160, hrc fuse link :, a) 100 amps, b) 32 amps, c) 63 amps, d) 20 amps, e) 4 amps, "digital true rms meters :, a) 100micro amp dc coil moving meter (96 x96)", "lighting arrestors, 4. 5 kv grade", 2 pole 8 way brilliancy switch (rotary wafer, mbb type, power transistors mj11016, contactors:, a) contactors (required 1 no for 15 kw mpccr), b) contactors (required 1 no fir 7.5 kw mpccr), c) contactors (required 1 no fir 4 kw mpccr), led indicating lamp suitable for nasu make mpccr, (a) green, (b) yellow, (c) red, supply of 36mfd 440vac capacitor, supply of 25mfd 600vac capacitor, supply of 2mfd 440vac capacitor, supply of 10mfd 600vac capacitor, supply of dual tone buzzer, "comprehensive annual maintenance contract (camc), preventive & break down, maintenance of nasu make signage board.", "emergency visit for the above 3 items of nasu, camc of alcms, nasu and rectification of, ccr, alcms & signage boards within 48 hours of complaint call and rectification of", note-1:-alltheexpensesoftechnicians/engineers,lodgingboarding,transportation,tools andtackles , incidentalchargesareincludedinthescopeofwork.nothingextrashallbe paid., sewage treatment (amc), "annual maintenance contract (camc) for 30 kld stp sewage treatment plants 02 sets (1 set at technical area and 1 set at residential area) quarterly once visit (4 four visits in a year) which includes cleaning of all pits/chambers from incoming of the stp to outgoing of the stp, panel housing cleaning, internal pcb cleaning, checking the control panel to ascertain that it shows normal operation, including all consumables, chemicals, spare, reparing, periodical service breakdown service/ maintenance to yield the effect as per standard of bis/ who/ pollution control board. the rates shall be inclusive of supply of day to day consumables, replacement of periodic consumables and rpair of filters /system/ parts/ motor/ pipes/ valves/ control wiring all complete by oem /authorised service agency and as directed by engineer-in-charge. the specialist shall inspect quarterly starting 1st week of commencement of contract. checking of communication cables, sort out any problematic issues with respect to the system and corrective actions for the existing problems and repair/replacement of unserviceable spares/consumables etc complete all as specified and directed by engineer in charge as per the inventory. thecontractorshallvisitthe sitebeforesubmittingthequotation. any missed out items not mentioned shall also include in the scope of work., (perquarterlyrateisinclusiveof2setsof30kldstpsewagetreatmentplants.), emergency visit by rep of agency/dealer 04 (four) times per year are also included in the scope of work, having valid license of oem attending emergency failures. the cost shall include all expenses including traveling, local conveyance, lodging and boarding charges etc.. complete., (replacementofallitemsifnecessaryaspertheinstructionsofengineerincharge.nothing extrashallbepaid.), make:bisineer", sewage transfer pumps-0.5hp, 220v, 1-phase submersible pump, 150lpm@6m head -2 nos, "fliter backwash pumps-, 1hp, 220v,1-phase openwell submersible pump, 1200-7800 lph@12-32m head range-2 nos", "e-cell settler solid transfer pumps-0.5hp, 220v, 1-phase submersible pump, 150lpm@6m head-, 1 no", "filter feed pumps-1hp, 220v,1-phase openwell submersible pump, 1200-7800 lph@12-32m, head range-nos 2", "e-cell module with 2 sets of (400mmx400mmx5mm-10 nos-1set) aluminium plates- 30 kld 1, no", "e-dosing pumps for sodium hypochlorite solution & alum with 100 litres ldpe chemical solution, tanks-0-6lph e-dosing pumps nos-2", piping with fittings & pressure gauges- 32mm dia cpvc- 1 lot, "motor control centre-motor control centre consisting of contactors & overload relays for sewage transfer pumps-2 nos, filter backwash pumps-2 nos e-cell settler solid transfer pump-1 no, filter feed pumps-2 nos, 0-270v, 16a auto transformers with limit switch-2 nos, single phase preventer-1no, current monitoring relays-2nos, 220/30v, 2500kva-2nos transformers, diodes, set-4 nos, control mcbs, control wiring etc -1 no", earthing pit- 40mm dia maintenance free earthing-1 no, cables-3cx1.5/2.5sqmm unarmoured copper, 1cx25sqmm unarmoured copper- 1 lot, sand filter with underbed & multi-grade filter media-ms cylinder , capacity 1.5cum/hr- 1 no, carbon filter with underbed & carbon media -ms cylinder , capacity 1.5cum/hr-1 no, raw water flow meter-ft 650- - 1 no, treated water flow meter-mag-650, 50nb -1 no, "items not specified above shall also include in the scope of work. the contractor shall visit, the site before submitting the quotation.", camcforwatertreatmentplants, "comprehensive annual maintenance contract (camc) for 2 cu.m/hr and 8 cu.m/hr water treatment plants 02 sets (1 set at technical area and 1 set at residential area) quarterly once visit (4 four visits in a year) which includes pressure sand filters, activated carbon filters with ms pressure vessels, water softners, pp cloring dosing pumps, centrifugal pumps with motors, gi pipes, valves and fittings mv panels, centrifugal cast ductile piping including all fittings, starters etc.. complete., cleaning of all pits/chambers from incoming of the wtp to outgoing of the wtp, panel housing cleaning, internal pcb cleaning, checking the control panel to ascertain that it shows normal operation, checking of communication cables, sort out any problematic issues with respect to the system and corrective actions for the existing problems and repair/replacement of unserviceable spares/consumables etc complete all as specified and directed by engineer in charge as per the inventory. the contractor shall visit the site before submitting the quotation. any missed out items not mentioned shall also include in the scope of work., (perquarterlyrateisinclusiveof2setsi.e2cu.m/hrand8cu.m/hr watertreatment plants andwaterpumphouse., 1 set consisting of 2 cu.m/hr and 8 cu.m/hr water treatment plants (1 set at technical area and 1 set at residential area), emergency visit by rep of agency/dealer 04 (four) times per year are also included in the scope of work, having valid license of oem attending emergency failures. the cost shall include all expenses including traveling, local conveyance, lodging and boarding charges etc.. complete., (replacementofallitemsifnecessaryaspertheinstructionsofengineerincharge.nothing extrashallbepaid.), mkake:bisneer", "pressure sand filter & activated carbon filter (dual media), 2 cu.m/hr (technical area)- set-01", pressure sand filter made of ms cylindrical pressure vessels for capacity as mentioned below 8 cu.m/hr (transit area)- set-01, "activated carbon filter made of ms cylindrical pressure vessels for capacity 8 cu.m/hr (transit, area)- set-01", "water softener (cat ion exchange) with all necessary equipment 2 cu.m/hr (technical area), 8 cu.m/hr (transit area)- set-01", "polypropylene chlorine dosing pump having 1 litres per hour capacity and maximum injection, pressure of 5.5 kg/sq.cm along with 100 litres capacity hdpe tank- nos-02", "horizontal centrifugal pump with motor (3ph, 415v) of following capacity 10 cu.m/hr @ 35 m head (to oht transit area)-nos-07, 2 cu.m/hr @ 35 m head (wtp technical area)-nos-02", "horizontal centrifugal pump with motor, 5 cu.m/hr @ 50 m head (radar building)-nos-02", "medium grade g.i. pipes with fittings of following size 100 nb-rmt-519.20, 80 nb-rmt-1279., 65 nb-rmt-684.80, 50 nb-rmt-1104.1, 40 nb-rmt-990.20, 32 nb-rmt-768.80, 25 nb-rmt-240.0", "mv panel, incoming: 160 a, 35 ka tpn mccb - 1set busbars: 160 a tpn aluminium busbars-1set outgoings:, 2 sets of dol starters suitable for 2cum/hr, 35 mtrs head pump tpn mccb of suitable rating -1 no, contactors of suitable rating -1 set, overload relay , single phasing protection -1 no on/off push buttons for manual operation -1 set on/off/trip led indication lamps -1 set, ammeter with cast resin cts and selector switch -1 set, 2 sets of dol starters suitable for 5cum/hr, 40 mtrs head pump motor consisting of the following: tpn mccb of suitable rating -1 no, contactors of suitable rating -1 set, overload relay , single phasing protection -1 no on/off push buttons for manual operation -1 set on/off/trip led indication lamps -1 set, ammeter with cast resin cts and selector switch -1 set, og for outdoor panel consisting of 1-125 amps tpn 35 ka mccb-2 - no-1", "free standing floor mounted mv panel made out of 14 swg ms sheet incoming: 125 a, 35 ka tpnmccb - 1set, busbars: 125 a tpn aluminium busbars-1set outgoings :, 2 sets of dol starters suitable for 8 cum/hr, 35 mtrs head pump motor consisting of the following: tpn mccb of suitable rating -1 no, contactors of suitable rating -1 set, overload relay , single phasing protection -1 no on/off push buttons for manual operation -1 set on/off/trip led indication lamps -1 set, ammeter with cast resin cts and selector switch -1 set, 2 sets of dol starters suitable for 10 cum/hr, 35 mtrs head pump motor consisting of the following:, tpn mccb of suitable rating -1 no contactors of suitable rating -1 set, overload relay , single phasing protection -1 no on/off push buttons for manual operation -1 set on/off/trip led indication lamps -1 set, ammeter with cast resin cts and selector switch -1 set, og for outdoor panel consisting of 1-63 amps tpn mccb-2 nos, og for 200 kl sump's lifting pump panel consisting of 1-63 amps tpn mccb-2 no-1", "centrifugally cast ductile piping including all fittings, iron pipes conforming to is 8329 class k9, with cement mortar, 100 nb-5273-rmt", "floor mounted mv panel made out of 14 swg ms incoming: 63 a, 35 ka tpn mccb - 1set busbars: 63 a tpn aluminium busbars -1set, 2 sets of dol starters suitable for 5 cum/hr, 50 mtrs head pump motor-1 no", "starter box of 3 phase 415v-4 wire free standing floor mounted mv panel made out of 14 swg ms, incoming: 100 a, 35 ka tpnmccb - 1set., busbars: 100a tpn aluminium busbars -1set.- 1 set", camc for dg set battery chargers, subheadiv:repair/supplyitems(consumables), "supply of spares for the 6.6a, 150w bi-directional elevated high intensity runway edge, light", 6.6a, 150w prefocused halogen lamp, lens gasket, bas plate gasket, breakable coupling, ss bolt set, outer inner lens(c/c or c/y), secondary lead, "supply of spares for the 6.6a, 150w unidirectional elevated high intensity runway, threshold light", 6.6a, 150w prefocused halogen lamp, lens gasket, bas plate gasket, breakable coupling, ss bolt set, spreader lens(green), secondary lead, "supply of spares for the 6.6a, 150w unidirectional elevated high intensity runway, approach light", 6.6a, 150w prefocused halogen lamp, lens gasket, bas plate gasket, breakable coupling, ss bolt set, spreader lens(clear), secondary lead, "supply of spares for the 6.6a, 100w unidirectional elevated high intensity runway end, light", 6.6a, 100w prefocused halogen lamp, lens gasket, bas plate gasket, breakable coupling, ss bolt set, spreader lens(green), secondary lead, supply of spares for the 6.6a, 2x105w bi-directional inset high intensity runway edge light, 6.6a, 105w prefocused halogen lamp, silicon gasket(o-ring), lens(c/c or c/y), prism, prism gasket, supply of blue , omni-directional 6.6a, 10-15w inset taxiway edge led light fixture, "supply of spares for the 6.6a, 1w omni -directional elevated medium intensity taxiway, light", 6.6a, prefocused led module with 1w blue led, lens(blue), lens gasket, lens holding ring, led driver, die cast aluminium alloy body, secondary lead, breakable coupling, "supply of spares for the 6.6a, 1w omni -directional elevated medium intensity taxiway, end light", 6.6a, prefocused led module with 1w red led, lens(red), lens gasket, lens holding ring, led driver, die cast aluminium alloy body, secondary lead, breakable coupling, supply of yellow, 5w, ip-66 led lamps for landing directional indicator, "supply of wind socks(black & white) of 900mmx300mmx3600mm dimensions for wind directional, indicator", supply of spares for the 6.6a, 3x200w precision approach path indicator, 6.6a, 200w halogen lamp bi-pin, red colour filter, reflector, lens(clear), toughened front glass, breakable coupling, cover sealing (rubber gasket), air filter, rewinding of following capacity and type of motor, 3-ph, 415v, 1.5 hp monobloc pump set, 3-ph, 415v, 3.0 hp monobloc pump set, 3-ph, 415v, 5.0 hp monobloc pump set, 3-ph, 415v, 5.0 hp submersible borewell pump set, 3-ph, 415v, 7.5 hp submersible borewell pump set, lifting of any type of submersible pump set per mtr by any mechanical tool including hdpe/gi pipes and power cables. lowering the same pump including hdpe/gi pipes and power cables. the cost includes lifting and lowering charges without any repair cost of pump, pipes & cables., supply of distilled water, consumables, supply of following items as per the specifications:, 9/11w led, 18w led, 30w led, 70w sv lamp, 5w led g9 bulb, 2700 k, 220v, 5w led e 14 base candle lamp, 2700k, 220v, 150w son-t sv lamp tubular, 400w elliptical hpsv lamps, 0.5w basic round b 22 led bulb (white colour), 150w metal halide lamp for swf231 1xmhntd-150w(philips), 70w metal halide lamp for mpf92 1xmhntd70w(philips), 40w led street light fixtures (crompton:lpto cdlm), 150w led flood light(philips: bvp 176 led165 frosted glass flood light), 90w led street light fixture(philips: brp033 led90 cw slr gr psu), 10w, outdoor led bulkhead fixture, 20 w, 4 feet led tube light fitting, 16w round led bulb with b-22 base(white), 12w square led surface light fixture full glow, 28w fluorescent t5 tube lights, electronic ballast ebs 114 tl/pls/plc sh, electronic ballast ebs 118 plc/plt sh, electronic ballast ebp 221/228 tl5/ebt 228 tl5, electronic ballast ebt 128 tl5, electronic ballast ebt 236 tld/ebe 236 tld, 70w copper wound ballast, 150w copper wound ballst, 400w copper wound ballast, ignitor for sv lamp 70w/150w/250w/400w, led driver (uin:240v, pin:82w max, iin:0.36a max, vout:60-74v dc, iout:950ma), led driver(s0dql-54-700-40w) for 40w cromton street light fixture(model no:40-cdl-m), led driver for rc 380bled-30-6500pseodwh, 150w led driver(philips: xitanium 150 w, 0.7a), surge protection device gen3 wire potted, 10kv, 43 uf, 250v capacitor, copper wire terminal, 30 uf, 440v capacitor, copper wire terminal, 15 uf, 440v capacitor, terminal lug, 10 uf, 440v capacitor, terminal lug, 8 uf, 440v capacitor, terminal lug, 2.25 uf, 440v capacitor, copper wire terminal, 6-32a, sp, c curve mcb, 40-63a, 2p, c curve mcb, 40-63a, 4p, c curve mcb, 40a, 4p, 300ma rcbo, 63a, 4p, 300ma rcbo, daily, weekly programmable electronic timer switch, supply of the following size lt cables, a)1.1kv, xlpe insulated pvc outer sheathed 3.5cx300 sqmm al armoured xlpe cables, b)1.1kv, xlpe insulated pvc outer sheathed 3.5cx240 sqmm al armoured xlpe cables, c)1.1kv, xlpe insulated pvc outer sheathed 3.5cx185 sqmm al armoured xlpe cables, d)1.1kv, xlpe insulated pvc outer sheathed 3.5cx120 sqmm al armoured xlpe cables, e)1.1kv, xlpe insulated pvc outer sheathed 3.5cx70 sqmm al armoured xlpe cables, f)1.1kv, xlpe insulated pvc outer sheathed 3.5cx50 sqmm al armoured, g)1.1kv, xlpe insulated pvc outer sheathed 3.5cx35 sqmm al armoured, h)1.1kv, xlpe insulated pvc outer sheathed 3.5cx25 sqmm al armoured, j)1.1kv, xlpe insulated pvc outer sheathed 4cx16sqmm al armoured, k)1.1kv, xlpe insulated pvc outer sheathed 4cx10sqmm al armoured, l)1.1kv, xlpe insulated pvc outer sheathed 4cx6sqmm al armoured, m)1.1kv, xlpe insulated pvc outer sheathed 3cx4sqmm al unarmoured, n)1.1kv, xlpe insulated pvc outer sheathed 4cx6sqmm cu unarmoured, o)1.1kv, xlpe insulated pvc outer sheathed 4cx4sqmm cu armoured, supply of the following size ht cables, a)11kv, xlpe insulated pvc outer sheathed 3cx240 sqmm al armoured xlpe cables, b)11kv, xlpe insulated pvc outer sheathed 3cx95 sqmm al armoured xlpe cables, supply of the following type single core wires., 1.1kv, 1.5sqmm frls cu multi stranded, 1.1kv, 2.5sqmm frls cu multistranded, 1.1kv, 4sqmm frls cu multistranded, 1.1kv, 6sqmm frls cu multistranded, 22.5mm led indication lights, 64/110/240v ac/dc, red/green/yellow/amber, 22.5mm led indication lights, 64/110/240v ac/dc, blue/white, phase failure relay with under & over voltage, (make : minilec, alv d2), overcurrent monitoring relay (minilec ocs d1), single phase preventer, 415v, vsp3, (minilec), master trip relay ,110v-125v dc(ge :vajh), digital voltmeter(schneider: conzerv dm 3210), digital ammeter(schneider: conzerv dm 3110), digital multifunction meter(schneider: conzerv em1000), 16sqmm grey terminal blocks, "supply erection testing and commissioning of gi earth pit of galaxy make model no. galaxy-gdt802 gi dual pipe (2meterlong 78-80mm dia earthing pipe in pipe 200 micron, hot galvanized elctrode) including galaxy moisture boosture eco friendly back fill compound , with standard brick work chamber and ms cover as per is (nothing extra shall be paid)", "supply erection testing and commissioning of gi earth pit of galaxy make model nogalaxy - gcbdp802 cu dual pipe(2meter long 78- 80 mm dia earthing pipe) including galaxy, moisture boosture eco friendly back fill compound , with standard brick work chamber and ms, cover as per is (nothing extra shall be paid)", supply and laying of 50 x 6 mm thick copper strip including sleeve on surface/trench/on walls as per directions of engineer in charge as per site condition.(nothing extra shall be paid), zinc alloy manual panel lock with key, smc/frp rectangular sintex junction box side hinged type(300x200x105mm), smc/frp rectangular sintex juction box side hinged type(250x200x100mm), supply of following size medium class gi pipes & fitting, 100mm, 80mm, 65mm, 50mm, 40mm, 32mm, 25mm, a) 32mm dia cpvc pipe, b)32mm dia equal tee, c) 32mm dia 90 degree bends, d) 32mm dia cpvc ball valve, e) 32mm dia cpvc coupler plain, f) 32mm dia cpvc union, g)32mm tank nipple-plain end, h) cpvc solvent 237 ml, testing charges of drinking water, testing charges of sewage water, rewinding of 60w ceiling fan, rewinding of 75w, 305mm sweep exhaust fan, rewinding of 90w, 300mm sweep exhaust fan, rewinding of 160w, 380mm sweep exhaust fan, rewinding of 180w, 600mm sweep air circulators, supply of silca gel, supply of following electrical items:, 1 module front white plate with frame, 2 module front white plate with frame, 3 module front white plate with frame, 4 module front white plate with frame, 6 module front white plate with frame, 8 module front white plate with frame, 12 module front white plate with frame, 6a switch (mk), 6a bell push switch(mk), 6a switch(legrand), 16a switch (mk), 16a switch(legrand), 2 module 6a, 3 pin power sockets(mk), 2 module 6a, 5 pin power sockets(legrand), 2 module 6/16a, 6 pin power sockets(mk), 2 module 6/16a , 3 pin power sockets(legrand), 3 module 6/16a, 3 pin power sockets(legrand), 220v, wall mounted door bell, 120w, 2module step type fan regulator(make: legrand), 120w, 2module step type fan regulator(make: mk), lifting of any type of submersible pumpset per mtr by any mechanical tool including hdpe/gi pipes and power cables. lowering the same pump including hdpe/gi pipes and power cables. the cost includes lifting and lowering charges without any repair cost of pump, pipes & cables., single phase preventer, 415v, gic sm 301, l&t mk1, 4p contactor,15a, l&t mk1, 9-14 a thermal overlaod relay., l&t mk1, 13-22 a thermal overlaod relay., l&t mn2, 9-15 a thermal overlaod relay., l&t mn2, 3-5 a thermal overlaod relay., l&t mn2, 6-10 a thermal overlaod relay., l&t contactor mnx-12, 3p, ac-3, 12a, l&t contactor mo12, 3p, ac-3, 12a, l&t contactormnx-18, 3p, ac-3, 18a, l&t contactormo18, 3p, ac-3, 18a, 3p mpcb, 2.5-4a, schneider, 3p mpcb, 4-6.3a, schneider, 240v coil for mnx45/50/70/80/mc/mcx21/22 contactor, 240v coil for mcx43, 400a , 4p contactor, 415v coil for mk1, 3p contactor, 15a, 3-phase dol starter suitable for 7.5hp submersible pump motor, 3-phase dol starter suitable for 5hp submersible pump motor, "arrangement of vehicle mounted aluminium ladder alongwith one driver for maintenance and repair, of street lights", supply of 12v, 7ah maintenance free battery, 12v, 160ah maintenance free heavy duty battery(cummins pulse lite), 12v, 65ah maintenance free heavy duty battery(cummins pulse lite), supply of following items:, capillary thermostat for 25litres /50 litres geyser(racold), 2 kw, geyser element for 25litres /50 litres geyser(racold), star delta electronic timer relay- series micon 225(make: gic), 220 v, ac undervoltage release for c power air circuit breakers(l&t), 220 v, ac shunt release for c power air circuit breakers(l&t), 40a, 2 pole, ac-3 contactor, 16a, 11kv hrc fuse, 40a, 11kv hrc fuse, 63a, 11kv hrc fuse, 3.15a, 11 kv pt fuse, "supply of transformer oil (mineral) as and when required as per the instruction of engineer-in-, charge", identification of fault in fibre optic cable inclduing hiring of machinery for cable fault locator, jcb for earth removal and replacement, "identification of fault in ht/lt cable of various sizes by hiring machinery for cable fault, first fault", supply of gear oil for 5 ton capacity crane, supply of brake oil for 5 ton capacity crane, supply of grease as per manufacturer recommendation, back-ups 230v, 2.56a, 600va/360w, apc schneider, power backup 230v ac to 110 v dc battery, 100va, supply of the following type valves:, 40mm bronze ball valve(screwed end), 50mm bronze gate valve(screwed end), 32mm bronze ball valve(screwed end), 25mm bronze ball valve(screwed end), 15 mm bronze ball valve(screwed end), 80mm bronze gate valve(screwed end), supply of 500kva ht avr, with input voltage range 9 kv to 13 kv , output voltage 11 kv, copper wound, with first filling of transformer oil with by back including transportaion., 50mm bronze foot valve, heat shrinkable straight through joint kit for 1.1kv, 3.5cx300sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx240sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx185sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx120sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx70sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx50sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx35sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 3.5cx25sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 4cx16sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 4cx10sqmm al armoured cable, heat shrinkable straight through joint kit for 1.1kv, 4cx6sqmm al armoured cable, "heat shrinkable straight through joint kit for 11kv(e)/6.6kv(ue), 3cx240sqmm al armoured, cable", heat shrinkable straight through joint kit for 11kv(e)/6.6kv(ue), 3cx95sqmm al armoured cable, heat shrinkable indoor termination for 11kv(e)/6.6kv(ue), 3cx240sqmm al armoured cable, heat shrinkable indoor termination for 11kv(e)/6.6kv(ue), 3cx95sqmm al armoured cable, battery charger for 200 kva, battery charger for 750 kva, 11kv ct primary (200/150/100/50) secondary (5a / 1a), pt 11 kv /110 v, hrc fuse for 11kv, spring charging motor, butterfly valve, 750 kva dg disply unit, supply of hi pot test kit for 11kv & 1.1kv
Bid only when you qualify — AI checks eligibility for you
supply of - rustoline, wd-40 spray, remover,paint,aersol,81716,loctite, paste,hand cleaning, 200gms, grafseal,adhesive packing,6mmx10mx0.5mm, rust remover spray,250ml aerosal, cotton waste, paper,emery,super fine,gr no:400, mseal, tape,teflon,roll,1/2inx12mtr, tape,taflon,3/4in, blade,hacksaw,12x1/2in,hss, buffing wheel,aper,ss,4in, paper,emery,gr.no:200,9x11 in, fevicol rubber adhesive,sr 998,1ltr pack, sheet,ptfe,size: 2.5x300x300mm, loctite,superflex,596,rtv silicone,300ml, loctite 577, loctite,master gskt,574, markin cloth, molykote.p-37,1 kg pack, grease gun,400gm,weight:1.2kg,680-50,sam, rope,manila,1/2in, penetrant&rust remover,500ml,aerosolcane, cutter,shim,8in, pump,hand operated,barrel,220ltr, clip,hose f/worm drive,13-20mm, clip,hose f/worm drive,18- 28mm, clip,hose f/worm drive, 25-38mm, clip,hose f/worm drive,32-50mm., clip,hose f/worm drive, 51- 70mm., clip,hose f/worm drive,60-80mm., clip,hose f/worm drive,82-102mm., molykote,supergliss spary,400 ml, wonder,x spray, tape,measuring,3mtr, tarpauline,hdpe w/eyelets,10x10m, tape,measuring,steel,30mtr, gasket jointing comp,hylomer, sheet,ptfe,2x300x300mm, sheet,ptfe,5x300x300mm, can,oil,1/2pint, brush,wire,brass, brush,wire,ss, sheet,polythene,0.5mm width 1.5 m, loctite,threaded sealant,hydraulic,542, cable tie,300mm,pvc, molykote,compound,111, silicon sealant,silastic,rtv 732,300 gm, wire,ss-304,0.8mm, scotch brite,6inwidth,coarse, wire,ss-304,1mm, wire,ss-304,0.5mm, stone,sic,combination,150x50x25,coarse, jointing sheet,neoprene rubber,5.0mm, jointing sheet,neoprene rubber,6.0mm, masking tape,2in, masking tape, hose,pvc,1/2inx16kgs, hose,pvc,1in,12 kg/cm2, scissors,medium size, paper,emery,grid size 120, hand pad,scotch brite,7440,180grit,6x9in, tarpaulin,canvas,12x15ft, tarpaulin,canvas,36x18ft, supra bins-sb-7,(polypropylene tray), supra bins-sb- 6,(polypropylene tray)- procurement of consumables required for pipeline maintenance in vijaipur region | quantity - 4158
"annual maintenance charges for split/ window ac works with following works -,(a) servicing once in a year. ,(b) quarterly preventive maintainance ,(c) checking selector switch , thermostat, relays, remote controle, motor bushing, tightening of nuts & bolts, drivemotors and fans, cooling efficiency, firmness of the suppportng arraneent for the compressor, blower motor, air conditioners casing and fixing of the air conditioners etc. ,(d) replacement of any component of air conditioners (outdoor and indoor uits, inlet and outlet pipelines, electrical connections etc) found defective after the abvoe checks and tests.,(e) charging of refgrigerant gas, oiling the motors, chemical washing ,",the spares replaced under comprehensive maintenance shall be measured and paid oem tax invoice if same company spare not avl in market then spares will be paid on company invoice with 15% contractor profit. (a) compressor (b) running capacitor (c) fan capacitor (d) fan motor (e) grill (f) chasis (g) remote (h) brass pipe (j) pcb board (k) thermostate (l) drain pipe (m) pipe insulation (m) power cord (m) air filer (n) wall bracket (o) condensor of out door unit.,installation of new split air conditiner stand on wall, connect inlet ac assembly to air conditioner , connect electricity supply to air conditioner and making insect proof the wall hole with white cement and check split ac functions after installation,dismantle of ac stand from wall, dismantly/fixed front air grill, disconnect electricity supply to air conditioner and re-installtion split air conditiner stand on wall, connect inlet ac assembly to air conditioner , connect electricity supply to air conditioner and making insect proof the wall hole with white cement and check split ac functions after installation,re-filling the ac gas, first check the compressor, connect valve on the compressor process tube, fil gas according to air conditioner check leakage after refill gas , - amc for repair and maintenance of air conditioner | quantity - 72
e-house package - development of surface facilities to supply natural gas to iggl pipeline at duliajan of m/s oil india limited
requirement of repairing, renovation, maintenance and upgradation, work etc at bakrol cattle pound & dog shelter - providing and laying cement concrete 1:4:8 (1- cement : 4- coarse sand : 8- graded brick bats aggregate 40mm normal size) and curing complete excluding cost of formwork in (a) foundation and cmt 2643.11 plinth 2 providing and laying cement concrete 1:3:6 (1- cement : 3-coarse sand : 6- hand broken stone aggregates 40mm nominal size) and curing complete. cmt 4006.15 3 providing and laying controlled cement concrete m.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (c) slabs,landing,shelves,balconies, lintels, beams, girders and cantilever up to floor two level. ground floor cmt 4496.07 first floor cmt 4496.07 4 extra for additional lift of concrete for all r.c.c.work above floor two level excluding cost of reinforcement second floor cmt 4535.92 5 brickwork: brick work using common burnt clay building bricks having crushing strength not less than 35 kg/sq. cm. in foundations and plinth in cement mortar 1:6 (1 cement :6 fine sand) for conventional type bricks. cmt 3981.21 6 brick work using common burnt clay building bricks having crushing strength not less than 35 kg/sq. cm. in cement mortar 1:6 (1 cement :6 fine sand) for superstructure up to two level height. for conventional type bricks. (a) for superstructure above plinth level up to floor two level (b) conventional. ground floor cmt 4253.46 first floor cmt 4253.46 7 half brick masonry in common brunt clay building bricks having crushing strength not less than 35 kg/sq.cm. in lime mortar 1:1.5 ( 1- lime :1.5 -coarse sand ) in foundation and plinth. (b) conventional. smt 566.91 21 8 extra for half brick masonry in superstructure above plinth level up to floor two level. (b)conventional ground floor smt 619.71 first floor smt 619.71 plaster work: 9 providing 15 mm thick cement plaster in single coat on rough (similar) side of single or half bricks walls for interior plastering up to floor two level and finished even and smooth in (ii) cement mortar 1: 4 (1 cement : 4 sand). this includes finishing with a floating coat of neat slurry and doing plaster after making thaiyaas / levellers and after approval from engineer in charge. ground floor smt 155.61 first floor smt 155.61 10 providing and laying polished kota stone slab flooring over 20mm (average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or l.m. 1.1.5 laid over and jointed with grey cement slurry including rubbing and polishing etc. complete. (b) 30 mm thick. smt 1085.48 11 providing and laying polished kota stone slab 25 mm thick in risers of steps, skirting dedo and pillars laid on 10 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. smt 1176.03 12 providing and applying penetrating & crystalline water proofing treatment to rcc structures. work shall be carried out suing penetron products / equivalent brand but of same standard and quality. the treatment shall be done as per the instructions of manufacturer and as approved by the consultants. smt 667 13 vata: rmt 23.45 providing cement vata (10 cms. x 10 cms size) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete 14 providing and fixing black or any approved colour granite stone counter for wash basin and sitting arrangement etc. the counter shall be sandwich type and shall have polished kotah stone as base on which the granite stone shall be resting. the counter shall be embedded in the wall at least 50 mm and shall be self resting and / or having granite stone as base. the visible edges of the polished kotah stone shall be cladded with the granite stone. the shape of the final product shall be of any shape in plan. smt 3200 15 providing,fixing at site 18-20 mm thick black coloured granite stone on the bottom,sides,top of window, door and vent periphery, self and sill, with necessary moulding at edges, fixing with araldite wherever required including cutting,grinding,moulding,making necessary holes, metallic anchor fasteners, making necessary provision for fixing of ms grill and windows, all contingencies etc. complete. smt 2600 22 16 providing and fixing double side polished 25 mm thick white or any colour marble stone to be fixed as a partition in wall. the size of a smt 952.43 partition shall be 1.20 mts. x 0.75 mts. one side of 1.20 mts length shall be embedded at least 50 mm in the wall vertically and shall be fixed with cement mortar 1:1. the partition shall be fixed after cutting the stone as per the design and pattern approved. the partition shall be polished on both the sides and shall be fixed as per the directions of the project consultants. all the visible edges of this stones shall be properly moulded and polished on site. 17 providing and laying white glazed tiles 6mm thick in skirting risers of steps and dado on 10mm thick cement plaster 1:3 (1-cement : 3- coarse sand) and jointed with white cement slurry .for dado smt 1044.23 18 providing and laying coloured glazed tiles of the size 300 mm x 200 mm x 8 mm / 300 mm x 450 mm x 8 mm in skirting, risers of steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry. smt 935 19 applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. smt 40.19 20 applying priming coat over new steel and other metal surface after and including preparing the surface by thoroughly cleaning, oil, grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead. smt 34.34 21 painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleaning the surface of all dirt, dust and other foreign matter. smt 86.94 22 wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. sor-2023-24 goverment of gujarat r&b department 18031 p-135 smt 78.44 23 extra over item (add 18031 as per sor item no:18.57 p-135) for every subsequent coat of wall painting with plastic emulsion paint ceilings roof of approved brand sor-2023-24 goverment of gujarat r&b department 18032 p-135 smt 111.83 23 24 providing and applying 2 mm thick texture of specified quality approved make make of asian, nerolec or equivalent as per approval of eic over plastered surface, at all levels, all floors, all height, all complete as per drawing, specifications, instruction & directions of the engineer-in charge. payment shall be done as per drawing/laid at site of plastered area. smt 376 25 texture paint: sq.m. 950 providing and laying texture paint of 1.00 mm thick and of approved shade, pattern on wall / ceiling of plastered or wooden panel / ceiling. rate include necessary back coat laapi, texture grout, and finishing coat of plastic emulsion paint 26 finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete smt 113.4 27 febrication new kg 175 28 febrication reparing kg 150 29 aluminium saction sq.ft 370 30 bricks work sq.ft 300 31 plaster per sq.ft 400 32 floring work with vitrified tiles sq.ft 110 33 floring with kota stone sq.ft 140 34 plumbing 1/2 per ft 200 35 plumbing 1 per ft 300 36 providing and fixing 35 mm thick water proof flush doors, rate also includes 10 x 7 cms teak wood (pure saag) frame and including fixing of 1.00 mm thick laminate sheets ( door skin) on both sides of the doors , border pattis of c.p. saag on thickness of the doors on all four sides, polishing the same and fixtures fasteners complete as directed.atleast 1 aldropt, 4 hinges, 2 handles (8") , 4 hinges, (4"), 1 stopper (10") , 1 taadi (10") , 1 door magnet / stop in each door smt 4806.42 37 gypboard false ceiling (gyproc mr (moisture resistant). providing and fixing m/f suspended ceiling, which includes gypsteel ultra crp surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centers. (single layer of 12.5mm tapered edge gyproc mr (conforming to bs 1230 part1) rate to include making cut outs for light fittings, grills diffusers, etc with necessary g.i. framing around the cut outs to make it strong & stable (heavy duty type). smt 753 38 providing and fixing of roller blind curtain/blackout. the fabric shall be woven from formulated platisol extruded over a polyaster yarn.the fabric shouldl be weaved to provide subtle view of the side of the blind and should offer elimination of glare and sunlight radiance upto a minimum of 80%.the fabric shall be flame retardant. smt 2610 39 chain-link fencing ( 4' 0" tall ) with necessary 3" diameter m.s. pipe of size 1.50 mts. and frame of 35 x 35 x 5 mm m.s. angle and smt 750 24 fixing with 25 x 5 mm m.s. flat, including necessary foundation work with r.c.c. 1:2:4, of size at least 350 mm x 350 mm x 230mm. rate also includes painting all the steel works with one coat of primer coat and 3 coats of approved brand and shade oil bound enamel paint, etc. complete. the spacing of the chain-link shall be not more than 50 mm c/c, and the gauge of the wire used shall be 10 gauge. 40 providing and fixing wash down water closet (european type, w.c.pan) with integral p or s trap including jointing the trap with soil pipe in cement mortar 1:1 (i-cement: 1-fine sand) (seal and cover to be measured and paid for separately) (a) vitreous china pattern :(i) in white colour. no 1290.8 41 providing and fixing g.i. inlet connection for flush pipe with w.c. pan each 14.97 42 providing and fixing plastic seat and cover for wash down water closer with c.p. brass hinges and rubber buffers. (b) black plastic seal and cover. each 288.45 43 providing and fixing washbasin with single hole for pillar tap with c.i. or m.s. brackets painted white including sutting holes and making good the same but excluding fittings.(a)vitreous china:(ii) flat back washbasin 550 mm x v 400mm size. (i) in white colour. each 1400.18 44 providing and fixing kitchen sink with c.i. or m.s. brackets, painted white including cutting holes in walls and making good the same but excluding fittings. (c) vitreous china sink.(i) 600mm x 450mm x l50mm size each 2257.69 45 providing and fixing c.p. brass towel rail complete with c.p. brass brackets fixed to wooden plugs with c.p. brass scews.(b) 600mm x 20mm size. each 597.22 46 providing and fixing c.p. brass waste for washbasin or sink. (b) 40mm dia. each 88.94 47 providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin. each 292.87 48 providing and fixing pillar tap, capstan head, screw down high pressure with screws, shanks and back nuts. (i) 15mm dia. each 305.67 49 providing and fixing heavy duty stainless steel flexible connection pipe set with acessories each 200 50 providing and fixing screw down bib taps of following size.(a) brass screw down bib tap polished bright. (i) l5mm dia.for washyard each 184.98 51 providing and fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick a.c. sheet or plywood sheet and fixing to wooden pluge with c.p. brass screws and washers. each 825.48 25 52 providing and fixing rubber plug for sink or wash basin. each 16.98 53 providing and fixing chromium plated,c.p.angle stop cock 15 mm heavy duty with cap of approved quality for . each 403.39 54 providing and fixing urinal of approved quality including connection with trap and with integral longitudinal flush pipe.(a) squating plate pattern white earthenware 550mm x 300mm. each 1535.63 55 providing and fixing c.p.brass waste for urinal. (b) 40mm dia. each 88.94 56 providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin/urinal. each 292.87 57 providing and fixing chromium plated brass half turn flush cock of approved quality including fixing in pipe line etc. complete.(i) 20mm dia. each 252.26 58 providing and fixing water closet squatting pan (indian type w.c. pan) size 580mm (earthwork, bed concrete, foot reste and trap to be measured and paid for separately) (a) vitreous china.(i) long pattern = white colour. each 926.1 59 providing and laying in trenches galvanized mild steel tubes (medium grade) of the following nominal bore, and tube fitting (earthwork in trenches to be measured and paid for separately) (e)65mm. rmt 716.66 60 providing and laying in trenches galvanized mild steel tubes (medium grade) of the following nominal bore, and tube fitting (earthwork in trenches to be measured and paid for separately) (h) 80mm rmt 910.69 61 providing and fixing gun metal check or non-return full way wheel valve. (a) 15mm dia. each 184.98 62 providing and fixing gun metal check or non-return full way wheel valve. (b) 20mm dia. each 201.8 63 providing and fixing gun metal check or non-return full way wheel valve. (c) 25mm dia. each 416.47 64 providing and fixing gun metal check or non-return full way wheel valve. (d) 32mm dia. each 311.61 26 65 providing and fixing gun metal check or non-return full way wheel valve. (e) 40mm dia. each 656.86 66 providing and fixing ball cock of approved. quality as directed. (a)copper metal (i) 25mm dia. each 131.57 67 providing and fixing ball cock of approved. quality as directed. (a)copper metal (ii) 50mm dia. each 187.96 68 providing and fixing ball cock of approved. quality as directed. (b) abonite (i) 25mm dia. each 101.89 69 providing and fixing ball cock of approved. quality as directed. (b) abonite (ii) 50mm dia. each 136.52 70 providing and fixing in position cowel went to pipes.(c) l00mm dia each 496.9 71 providing, laying and jointing in true line and level 160 diameter u.p.v.c (type b) conforming to is 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to isi 14735 -1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of pvc clamp of the size 160mm diameter x 210mm length x 196 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. rmt 822.99 72 providing, laying and jointing in true line and level 110 diameter u.p.v.c (type b) conforming to is 13592-1992 with one end plain and other end socketed with rubber ring,& fittings conforming to isi 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of pvc clamp of the size 110 mm diameter x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. rmt 826.88 73 providing and fixing pvc swr pipes is 13592 for drain - 75 mmdia sor-2023-24 goverment of gujarat r&b department m803 p-41 rmt 169 74 providing and fixing p.v.c. pipes 10 kgf / sq.cm. 50mm dia. sor-2023-24 goverment of gujarat r&b department m443 p-26 rmt 105 27 75 providing and fixing p.v.c. pipes 10 kgf / sq.cm. 40mm dia.. rmt 70 76 providing and fixing pvc swr p- trap is 14735 for drain -110x110 - each 186 77 providing and fixing pvc swr nahni trap is 14735 for drain- 100 mm diameter with jali of the following nominal diameter of self cleansing design with c.i scread down or hinged grating including the cost of cutting and making good the walls. each 565.43 78 providing and fixing pvc swr nahni trap is 14735 for drain -75 mm diameter with jali of the following nominal diameter of self cleansing design with c.i scread down or hinged grating including the cost of cutting and making good the walls. each 552.83 79 providing and laying (to level or slopes) and jointing with stiff mixture of cement mortar in proportion 1:1 salt glazed stoneware pipes including testing of pipes and joints complete.(a) l00mm dia. rmt 211.05 80 providing and laying (to level or slopes) and jointing with stiff mixture of cement mortar in proportion 1:1 salt glazed stoneware pipes including testing of pipes and joints complete.(b) l50mm dia. rmt 288.23 81 providing and laying cement concrete 1:5:10 (1cement : 5-fine sand :10-graded stone aggregate 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete. (a) 100 mm dia. (112 mm ave.bed thickness) rmt 125.9 82 providing laying (to level or slopes) and jointing reinforced concrete light duty non-pressure pipes i.s. class np2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(b) l50mm rmt 246.21 83 providing laying (to level or slopes) and jointing reinforced concrete light duty non- pressure pipes i.s. class np3 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(c) 250mm rmt 344.59 84 providing laying (to level or slopes) and jointing reinforced concrete light duty non- pressure pipes i.s. class np3 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (d) 300mm rmt 658.89 85 providing laying (to level or slopes) and jointing reinforced concrete light duty non- pressure pipes i.s.class np3 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(e) 450mm rmt 1050.09 86 providing and fixing l00mm sand cast iron grating for gully, floor or nahni trap. each 36.61 87 providing and fixing s.w. gully trap with c.i. grating brick masonry chamber and water tight c.i. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) square mouth traps. (b) l50mm x l00mm size p or r type each 1234.57 28 88 constructing brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm c.i. horizontal grating wih frame complete. each 1997.22 89 constructing brick masonry road gully chamber 1100mm x 775mm including 500mm x 450mm (c.i.horizontal grating with frame and vertical grating complete.) each 5077.8 90 providing and fixing g.i. rain water spout of 50mm dia. and 30cm. length. each 100.9 91 providing and fixing cast iron steps of size 500mm x l50mm x 22.5mm and painting with two coats of anti-corrosive paint etc. complete. each 162.23 92 supplying and fixing c.i. cover 300mm x 300mm without frame for gulley trap (standard pattern) the weight of cover to be not less 4.53 kg.) each 491.8 93 constructing brick masonry chamber for underground c.i. inspection chamber and bends with bricks having crushing strength not less than 35kg/ cm2 in c.m. 1:5 c.i. cover with frame (light duty) 455mm x 6l0mm internal dimensions total weight of cover with frame to be not less than 38kg. (wt. of cover 23 kg.) and wt. of frame 15kg.) (r.c.c. top slab with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete. (iii)inside dimensions 600mm x 850 mm and 450mm deep for pipe lines with three or more inlets. each 7109.35 94 providing erecting and fixing double coated isi water tank of required capacity each with all necessary fittings and connection etc. complete liter 3.91 on terrace 95 supplying and erecting water filter cum purifier with ultra violate technology. (aquaguard / waterdoc model or equivalent nos. 4484 symphony/ crystal/videocon model) 96 aluminium : smt 2850 29 providing & fixing in position external quality high grade anodized (preferably m-6), aluminum door , ventilations, window fix /sliding type - 2/3/4 track with frame & shutter using approved quality metalic color anodised aluminum section of standard weight of "jindal" or equivalent make, including p/f installing 5 mm thick approved clear or frosted glass of modiguard or equivalent make with necessary fixtures & fittings of standard quality as approved by engg.in charge etc. complete as directed and approved. rate includes all necessary hardware, fixtures, locks, handles, door-stop, door-magnets, etc. as required upto the fullest satisfaction of consultants. the ventilations shall be of movable type. 97 providing and fixing window having extruded aluminum colour anodized section frame main outer size 127mm x 38.10mm x 1.35mm @wt. 1.384kg/m, horizontal four track member size 122.20mm x 31.75mm x 1.10mm@ wt 1.205 kg/m, vertical member of size 122.20mm x 31.75mm x 1.50mm @1.398 kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm@ 0.456kg/mt ,vertical member of size 40mm x 18mm x 1.29mm @ 0.456 kg/mt with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc complete for window. (ahmedabad city building sor 2023-24) item code11026 smt 2119.14 98 providing and fixing window having extruded aluminum colour anodized section frame main outer size 95mm x 24mm x 1.17mm @ wt.of 0.738 kg/mt , horizontal three track member size 92mm x 31.75mm x 1.30mm,@ wt.1.07 kg/mt , vertical member of size 92mm x 31.75mm x 1.50mm @ wt. 1.06 kg/mt with sliding shutters of horizontal member size 40 mmx18mm x1.29mm @ wt.of 0.456 kg/mt, vertical member of size 40mm x 18mm x 1.29 mm @ wt.of 0.456kg/mt/ with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc . smt 1568.27 99 providing and fixing 35 mm thick shutters for doors, windows and clerestory windows including indian teak wood frames 10 cm x 7 cm. size including anodized alluminium fixtures and fastenings including primer coat of approved quality and two coats of oil painting etc, complete. (i) fully glazed. smt 4595.06 30 (ii) fully panelled. smt 5285.45 (iii) partly panelled and partly glazed. smt 4940.25 making water connection from exi.muni.water line. no. 250 100 carrying out timber treatment to all wood work smt 54.98 including drilling holes and spraying oil based chemical solution on surface of timber work for termite control including labor and material etc. complete. using chlorpyriphos20 ec as per 6313 2013 part iii (1% concentration by mass) is recommended one litre chemical emulsion diluted with 19 liters of kerosene. total diluted concentration will be 20 liters inclusive of 1 liter chemical emulsion application in drilled holes and 0.75 / litre chemical per one sqmt two coat on wood surface not protected by paint or varnish. 31 101 door closer: no. 850 providing and fixing hydraulic door closer of approved size of ebco, kadson, falcon or equivalent isi make as directed etc. complete 102 providing 2 mm thick f.r.p.gutter with necessary m.s.supporting brackets. rmt. 400 103 dismantling santtary fittings like wash basin . w.c. pan indian and european type, flushing tank etc. including stacking the materials with all lead and lift. each 401.63 104 supplying and fixing pvc water tank of isi mark including delivery at site,supply and fixing inlet,outlet, overflow,ballcock,drainage sleeves of specific size with necessar neoprene/gasket/ packing/ washer,g.i washer and checknut etc.compt. as directed on terrace, loft,bathroom etc in any height. the rate shall be included for fixing additional accessories supplied by suppliyer accessories. lit. 5.5 105 provoding and fixing 1.2x0.6 mt board with 14 gauge ms sheet colored three coats of approved quality of oil paint with radium numbering. fixing with necessary bolt, screws etc. up to any lead from fabrication unit to municipal building no. 1970 106 providing & laying led tubelight of approved quality & syska, philips, or equivalent brand with necs. tolls & fittings. rate also include all types of labour work & conveying charges. etc. comp. no. 695 107 removing and scraping of old deteriorated bathroom-toilet dado / flooring of any thickness from wall / r.c.c member, flooring including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift smt 85 108 providing & fixing 25mm dia upvc valve/cock to wall,ceiling & floor open / concealed upvc pipeline schedule - 80 of "prince" or equivalent brand of following nominal bore with all required fitting with brass insert wherever required,clamps & solution incl.making good the wall,ceiling and floor. no. 690 109 providing and fixing flush tank in position with clamps, 32mm nominal internal diameter flush pipe for high level flushing cistern, etc. including connecting the flush pipe with cistern and closet and making good the walls and floors. each 1950 110 glass: providing and fixing following thickness glass. the glass shall be fixed either with beading patti or as directed by the consultants. it also includes necessary frosting in pattern as per the design / directions and also the moulding if necessary
complete overhauling work of kanohar make 150 mva, 220/132 kv auto transformer no. 2 (sl. n.-kt 150000/5) and 132/33 kv 50 mva power transformer no. 2 (s.n.-kt 50000/70 including (oil leakage rectification, replacement of gaskets in main tank body & oltc unit & valve replacement of oil & gas circulation pipeline, pre/post installation test and repairing, refilling, testing & interlinking of transformer auxiliary unit ctr make nifp system & oltc) at 220/132/33 kv gss ulijhari (chaibasa-i), overhauling, testing etc. of one no. 132/33 kv, 50 mva imp make power transformer no-2, sl. no.-pt 7274 of 132/33 kv grid substation, manoharpur including oil filtration painting, erection, dismantling, replacement of damaged/worn out part, copper strip earthing etc. all complete job, urgent requirement of 132/33 kv 50 mva & 20 mva power transformer accessories at 132/33kv gss, noamundi and 132/33 kv gss rajkharsawan, work of installation of cable tray with support hanger in main & branch cable trenches at 132/33 kv gss, kendposi under tsd kendposi, painting of switchyard equipment, support structure etc. in switchyard at 132/33 kv gss, rajkharsawan, naming of 132 kv, 33kv feeders in their respective bays and structure & equipment painting work at 132/33 kv gss, manohapur.
shifting of filtration machine , transformer oil tank shifting , arrangement of dry air or n2 , dismantling and assembly of hv lv links jumpers etc , draining and refilling of transformer oil , attending oil leakage , replacement of gasket of all inspection cover , replacement of gasket of oil pipeline and prv , filtration of transformer oil , servicing of oltc mech , air venting and tightness , servicing of marshalling box , cleaning of transformer , complete testing of 30mva st 1 2 , painting of 30mva st 1 2 and associated equipment - boq station transformer | quantity - 2426
supply of - ball bearing of 23mm aa craft sp munt schilka gun,zsu 23 , split pin 2 16 001 of 23mm aa craft sp munt,schilka gun zsu 23 , gasket of 23mm aa craft sp,munt schilka gun zsu 23 , second stage valve kttb 1,033 of 23mm aa craft sp munt schilka gun zsu 23 ,,bushing of 23mm aa craft sp munt schilka gun zsu,23 , second stage connecting rod kttb 1 011 of,23mm aa craft sp munt schilka gun zsu 23 , worm,wheel of 23mm aa craft sp munt schilka gun zsu 23 ,,pusher lever spring of 23mm aa craft sp munt,schilka gun zsu 23 , outer spring of 23mm aa craft,sp munt schilka gun zsu 23 , hinge coupling,assembly of 23mm aa craft sp munt schilka gun zsu,23 , screw m8 35 66 019 of 23mm aa craft sp munt,schilka gun zsu 23 , muzzle adapter of 23mm aa,craft sp munt schilka gun zsu 23 , wrench 7811,002581 of 23mm aa craft sp munt schilka gun zsu 23,, cover lock of 23mm aa craft sp munt schilka gun,zsu 23 , screw m14 1 5 25 66 019 of 23mm aa craft sp,munt schilka gun zsu 23 , screw m5 20 66 016 of,23mm aa craft sp munt schilka gun zsu 23 , screw,m6 12 66 019 of 23mm aa craft sp munt schilka gun,zsu 23 , screw m6 16 66 019 of 23mm aa craft sp,munt schilka gun zsu 23 , screw m6 20 66 019 of,23mm aa craft sp munt schilka gun zsu 23 , screw,m3 8 66 016 of 23mm aa craft sp munt schilka gun,zsu 23 , screw m6 22 of 23mm aa craft sp munt,schilka gun zsu 23 , screw m8 20 66 019 of 23mm aa,craft sp munt schilka gun zsu 23 , spring handle of,23mm aa craft sp munt schilka gun zsu 23 , pin 4c 3 8,of 23mm aa craft sp munt schilka gun zsu 23 , pin,4p2 2a 18 of 23mm aa craft sp munt schilka gun zsu,23 , pin 4p2 2a 20 of 23mm aa craft sp munt schilka,gun zsu 23 , pin 6c3 16 of 23mm aa craft sp munt,schilka gun zsu 23 , front attachment right hand,of 23mm aa craft sp munt schilka gun zsu 23 , pin,8p2 2a 22 of 23mm aa craft sp munt schilka gun zsu,23 , front attachment left hand of 23mm aa craft,sp munt schilka gun zsu 23 , taper pin 2 16 of 23mm,aa craft sp munt schilka gun zsu 23 , pin of 23mm aa,craft sp munt schilka gun zsu 23 , pin conical 4 25,of 23mm aa craft sp munt schilka gun zsu 23 ,,trunnion of 23mm aa craft sp munt schilka gun zsu,23 , washer of 23mm aa craft sp munt schilka gun,zsu 23 , pin cotter 1 12 001 of 23mm aa craft sp,munt schilka gun zsu 23 , nipple of 23mm aa craft sp,munt schilka gun zsu 23 , pin cotter 1 6 16 001 of,23mm aa craft sp munt schilka gun zsu 23 , split pin,2 5 16 001 of 23mm aa craft sp munt schilka gun zsu,23 , split pin 2 5 25 001 of 23mm aa craft sp munt,schilka gun zsu 23 , left hand valve of 23mm aa,craft sp munt schilka gun zsu 23 , stop washer 17 2,of 23mm aa craft sp munt schilka gun zsu 23 ,,spring of 23mm aa craft sp munt schilka gun zsu 23,, taper pin 4 16 of 23mm aa craft sp munt schilka,gun zsu 23 , small washer of 23mm aa craft sp munt,schilka gun zsu 23 , housing of sleeve lock of 23mm,aa craft sp munt schilka gun zsu 23 , bolt 3m6 10 66,019 of 23mm aa craft sp munt schilka gun zsu 23 ,,bolt 3m6 16 66 016 of 23mm aa craft sp munt schilka,gun zsu 23 , bolt 3m8 20 66 016 of 23mm aa craft sp,munt schilka gun zsu 23 , bolt m12 35 66 019 of 23mm,aa craft sp munt schilka gun zsu 23 , bolt m24 32 77,019 of 23mm aa craft sp munt schilka gun zsu 23 ,,bolt m4 20 66 016 of 23mm aa craft sp munt schilka,gun zsu 23 , boltm6 16 16 66 019 of 23mm aa craft sp,munt schilka gun zsu 23 , big washer of 23mm aa,craft sp munt schilka gun zsu 23 , bolt m6 18 66 019,of 23mm aa craft sp munt schilka gun zsu 23 , bolt,m6 20 66 019 of 23mm aa craft sp munt schilka gun,zsu 23 , spring of slide of 23mm aa craft sp munt,schilka gun zsu 23 , bolt m8 12 66 019 of 23mm aa,craft sp munt schilka gun zsu 23 , bolt m8 18 66 019,of 23mm aa craft sp munt schilka gun zsu 23 , bolt,m8 20 66 019 of 23mm aa craft sp munt schilka gun,zsu 23 , bolt 3m6 12 66 019 of 23mm aa craft sp munt,schilka gun zsu 23 , bolt m10 25 66 019 of 23mm aa,craft sp munt schilka gun zsu 23 , bolt m10 35 66,019 of 23mm aa craft sp munt schilka gun zsu 23 ,,bolt m8 22 66 019 of 23mm aa craft sp munt schilka,gun zsu 23 , bolt m6 25 of 23mm aa craft sp munt,schilka gun zsu 23 , split pin 2 12 051 of 23mm aa,craft sp munt schilka gun zsu 23 , bolt 2m10 30 66,019 of 23mm aa craft sp munt schilka gun zsu 23 ,,bolt m6 20 of 23mm aa craft sp munt schilka gun,zsu 23 , cambric article 430 mounting set of 23mm,aa craft sp munt schilka gun zsu 23 , split pin 3 2 25,001 of 23mm aa craft sp munt schilka gun zsu 23 ,,washer 3h 65g of 23mm aa craft sp munt schilka,gun zsu 23 , nut m2 2 1 5 10 40 of 23mm aa craft sp,munt schilka gun zsu 23 , nut m2 2 1 5 8 55 06 of,23mm aa craft sp munt schilka gun zsu 23 , nut m10,051 of 23mm aa craft sp munt schilka gun zsu 23 ,,nut m8 051 of 23mm aa craft sp munt schilka gun,zsu 23 , washer 12h 65g of 23mm aa craft sp munt,schilka gun zsu 23 , spring washer 5h 65g of 23mm,aa craft sp munt schilka gun zsu 23 , washer 6h 65g,of 23mm aa craft sp munt schilka gun zsu 23 ,,washer 12 65g of 23mm aa craft sp munt schilka,gun zsu 23 , washer 24 65g of 23mm aa craft sp,munt schilka gun zsu 23 , washer 5 65g of 23mm aa,craft sp munt schilka gun zsu 23 , spring washer 6h,65g of 23mm aa craft sp munt schilka gun zsu 23 ,,bolt m10 20 66 019 of 23mm aa craft sp munt schilka,gun zsu 23 , split pin 3 2 12 66 019 of 23mm aa craft,sp munt schilka gun zsu 23 , right hand clamp,bracket assembly of 23mm aa craft sp munt schilka,gun zsu 23 , ring kpbib of 23mm aa craft sp munt,schilka gun zsu 23 , leaf spring assembly of 23mm,aa craft sp munt schilka gun zsu 23 , obturting,bush of 23mm aa craft sp munt schilka gun zsu 23 ,,sensor plug of 23mm aa craft sp munt schilka gun,zsu 23 , obturating bushing of 23mm aa craft sp,munt schilka gun zsu 23 , insulator of 23mm aa,craft sp munt schilka gun zsu 23 , a is of 23mm aa,craft sp munt schilka gun zsu 23 , clamp of 23mm aa,craft sp munt schilka gun zsu 23 , bolt of 23mm aa,craft sp munt schilka gun zsu 23 , lockup bush,spacing bush of 23mm aa craft sp munt schilka gun,zsu 23 , bush of 23mm aa craft sp munt schilka gun,zsu 23 , third stage piston kpv kttb of 23mm aa,craft sp munt schilka gun zsu 23 , flash eliminator,of 23mm aa craft sp munt schilka gun zsu 23 , oil,pump kttb 1 07 of 23mm aa craft sp munt schilka,gun zsu 23 , impeller kpv 1 06 of 23mm aa craft sp,munt schilka gun zsu 23 , first stage valve kttb 1,016 of 23mm aa craft sp munt schilka gun zsu 23 ,,gas regulator of 23mm aa craft sp munt schilka,gun zsu 23 , stud of 23mm aa craft sp munt schilka,gun zsu 23 , screw of 23mm aa craft sp munt,schilka gun zsu 23 , tube of 23mm aa craft sp munt,schilka gun zsu 23 , small tube of 23mm aa craft sp,munt schilka gun zsu 23 , pipe line of 23mm aa craft,sp munt schilka gun zsu 23 , inner armour hose of,23mm aa craft sp munt schilka gun zsu 23 , recoil,buffer body rh of 23mm aa craft sp munt schilka,gun zsu 23 , rod of 23mm aa craft sp munt schilka,gun zsu 23 , pusher guide right hand of 23mm aa,craft sp munt schilka gun zsu 23 , pusher assembly,left hand feed of 23mm aa craft sp munt schilka,gun zsu 23 , armour hose assembly of 23mm aa,craft sp munt schilka gun zsu 23 , lever of 23mm aa,craft sp munt schilka gun zsu 23 , right hand slide,of 23mm aa craft sp munt schilka gun zsu 23 , left,slide of 23mm aa craft sp munt schilka gun zsu 23 ,,left hand ratchet of 23mm aa craft sp munt schilka,gun zsu 23 , lower distribution bo of 23mm aa craft,sp munt schilka gun zsu 23 , upper distribution bo,of 23mm aa craft sp munt schilka gun zsu 23 , micro,switch of 23mm aa craft sp munt schilka gun zsu 23,, non return valve of 23mm aa craft sp munt,schilka gun zsu 23 , block of 23mm aa craft sp munt,schilka gun zsu 23 , shutter block of 23mm aa craft,sp munt schilka gun zsu 23 , rubber spacer of 23mm,aa craft sp munt schilka gun zsu 23 , rear block of,23mm aa craft sp munt schilka gun zsu 23 , pusher,assembly left feed of 23mm aa craft sp munt,schilka gun zsu 23 , pusher assembly right feed of,23mm aa craft sp munt schilka gun zsu 23 , delivery,hose assembly of 23mm aa craft sp munt schilka,gun zsu 23 , brush assembly of 23mm aa craft sp,munt schilka gun zsu 23 , auto safety assembly of,23mm aa craft sp munt schilka gun zsu 23 , front,cartridge stop assembly rh of 23mm aa craft sp,munt schilka gun zsu 23 , front cartridge stop,assembly lh of 23mm aa craft sp munt schilka gun,zsu 23 , rear shutter assembly of 23mm aa craft sp,munt schilka gun zsu 23 , pipeline assembly of 23mm,aa craft sp munt schilka gun zsu 23 , pusher,assembly right hand feed of 23mm aa craft sp munt,schilka gun zsu 23 , t piece for feeding oil line of,23mm aa craft sp munt schilka gun zsu 23 , left,hand small sleeve of 23mm aa craft sp munt schilka,gun zsu 23 , left hand big sleeve of 23mm aa craft,sp munt schilka gun zsu 23 , gear of 23mm aa craft,sp munt schilka gun zsu 23 , twin gear of 23mm aa,craft sp munt schilka gun zsu 23 , gear shaft of,23mm aa craft sp munt schilka gun zsu 23 , bevel,gear of 23mm aa craft sp munt schilka gun zsu 23 ,,outlet pipe connection of 23mm aa craft sp munt,schilka gun zsu 23 , locking ring of 23mm aa craft,sp munt schilka gun zsu 23 , foot assembly of 23mm,aa craft sp munt schilka gun zsu 23 , transmitter,insulator of 23mm aa craft sp munt schilka gun zsu,23 , iginition coil assembly of 23mm aa craft sp munt,schilka gun zsu 23 , rubber packing gland of 23mm,aa craft sp munt schilka gun zsu 23 , packing of,23mm aa craft sp munt schilka gun zsu 23 , front,upper tie rod assembly of 23mm aa craft sp munt,schilka gun zsu 23 , rear upper tie rod assenbly of,23mm aa craft sp munt schilka gun zsu 23 , front,lower tie rod assenbly of 23mm aa craft sp munt,schilka gun zsu 23 , rear lower tie rod assenbly of,23mm aa craft sp munt schilka gun zsu 23 ,,lubricator of 23mm aa craft sp munt schilka gun,zsu 23 , retracting cylinder of 23mm aa craft sp,munt schilka gun zsu 23 , folding plat form of,23mm aa craft sp munt schilka gun zsu 23 , cover of,23mm aa craft sp munt schilka gun zsu 23 , bracket,of 23mm aa craft sp munt schilka gun zsu 23 , plate,of 23mm aa craft sp munt schilka gun zsu 23 , rod,assembly of 23mm aa craft sp munt schilka gun zsu,23 , generator tacho tg 2m2 of 23mm aa craft sp,munt schilka gun zsu 23 , remote pressure gauge,indicator of 23mm aa craft sp munt schilka gun zsu,23 , buckle of 23mm aa craft sp munt schilka gun,zsu 23 , left hand rear attachment assembly of,23mm aa craft sp munt schilka gun zsu 23 , right,hand rear attachment assembly of 23mm aa craft,sp munt schilka gun zsu 23 , transmitter body assy,of 23mm aa craft sp munt schilka gun zsu 23 ,,sensor instulator assembly of 23mm aa craft sp,munt schilka gun zsu 23 , armature pusher,assembly of 23mm aa craft sp munt schilka gun zsu,23 , connector assembly of 23mm aa craft sp munt,schilka gun zsu 23 , receiver cover right hand,assembly of 23mm aa craft sp munt schilka gun zsu,23 , receiver cover left hand assembly of 23mm aa,craft sp munt schilka gun zsu 23 , right lever,assembly of 23mm aa craft sp munt schilka gun zsu,23 , washer 10 02 0112 of 23mm aa craft sp munt,schilka gun zsu 23 , washer 10 65g of 23mm aa craft,sp munt schilka gun zsu 23 , washer 16 0 5 40 019 of,23mm aa craft sp munt schilka gun zsu 23 , washer 5,021 of 23mm aa craft sp munt schilka gun zsu 23 ,,washer 8 021 of 23mm aa craft sp munt schilka gun,zsu 23,desktop, laptops, test, qwertyusderftgyhuj, hr hiring,,canteen| quantity - 1414
supply of djoint rubber ring with nut and bolt isi 300 mm , djoint,rubber ring with nut and bolt isi 250 mm , djoint rubber,ring with nut and bolt isi 200 mm , djoint rubber ring with,nut and bolt isi 150 mm , djoint rubber ring with nut and,bolt isi 100 mm , djoint rubber ring with nut and bolt isi,80 mm , pvc pipe 10 kg cm2 isi 250 mm , pvc pipe 10 kg,cm2 isi 200 mm , pvc pipe 10 kg cm2 isi 180 mm , pvc,pipe 10 kg cm2 isi 160 mm , pvc pipe 10 kg cm2 isi 140,mm , pvc pipe 10 kg cm2 isi 110 mm , pvc pipe 10 kg cm2,isi 90 mm , pvc pipe 10 kg cm2 isi 50 mm , upvc pipe 10,kg cm2 isi 63 mm , upvc pipe 10 kg cm2 isi 75 mm , cast,iron sluice valve double flanged heavy duty isi 300 mm ,,cast iron sluice valve double flanged heavy duty isi 250,mm , cast iron sluice valve double flanged heavy duty isi,200 mm , cast iron sluice valve double flanged heavy duty,isi 150 mm , cast iron sluice valve double flanged heavy,duty isi 125 mm , cast iron sluice valve double flanged,heavy duty isi 100 mm , cast iron sluice valve double,flanged heavy duty isi 80 mm , cast iron sluice valve,double flanged heavy duty isi 65 mm , cast iron sluice,valve double flanged heavy duty isi 50 mm , upvc pipe 1 2,inch , upvc coupler 1 2 inch , upvc elbow 1 2 inch , upvc,bend 1 2 inch , upvc ft brass 1 2 inch , upvc mt brass 1 2,inch , upvc offset 1 2 inch , upvc pipe 1 inch , upvc,coupler 1 inch , upvc elbow 1 inch , upvc bend 1 inch ,,upvc ft brass 1 inch , upvc mt brass 1 inch , upvc offset 1,inch , gi barrel nipple 1 3 inch , gi barrel nipple 1 6 inch ,,gi barrel nipple 1 9 inch , barrel nipple gi 1 12 inch , barrel,nipple gi 1 24 inch , service saddle 2 1 2 inch , service,saddle 3 1 2 inch , service saddle 4 1 2 inch , service,saddle 6 1 2 inch , service saddle 8 1 2 inch , pata clamp 2,1 2 inch , pata clamp 3 1 2 inch , pata clamp 4 1 2 inch ,,pata clamp 6 1 2 inch , pata clamp 8 1 2 inch , pata clamp,10 1 2 inch , brass valve rn 1 2 inch , brass valve rn 1 inch,, brass valve rn 2 inch , brass valve rn 3 inch , brass valve,rn 4 inch , pvc pipe coupler 2 inch , pvc pipe coupler 2 1 2,inch , pvc pipe coupler 3 inch , pvc pipe coupler 4 inch ,,pvc pipe coupler 6 inch , pvc pipe coupler 8 inch , nut bolt,403 inch , nut bolt 404 inch , nut bolt 405 inch , nut bolt,408 inch , gland rope turner 8 mm , gland rope turner 10,mm , ci telepiece 300 mm , ci telepiece 250 mm , ci,telepiece 200 mm , ci telepiece 150 mm , ci telepiece 125,mm , ci telepiece 100 mm , ci telepiece 80 mm , ci,telepiece 65 mm , ci telepiece 50 mm , rubber packing,300 mm , rubber packing 250 mm , rubber packing 200,mm , rubber packing 150 mm , rubber packing 125 mm ,,rubber packing 100 mm , rubber packing 80 mm , rubber,packing 65 mm , rubber packing 50 mm , ci gasket ring,300 mm , ci gasket ring 250 mm , ci gasket ring 200 mm,, ci gasket ring 150 mm , ci gasket ring 100 mm , ci,gasket ring 80 mm , end plug pvc 250 mm , end plug pvc,200 mm , end plug pvc 180 mm , end plug pvc 160 mm ,,end plug pvc 140 mm , end plug pvc 110 mm , end plug,pvc 90 mm , end plug pvc 50 mm , end plug pvc 63 mm ,,end plug pvc 75 mm , tap 1 2 inch , socket gi 1 2 inch ,,suction pipe 100 feet 4 inch , suction pipe 100 feet 2 inch ,,flanch ci 2 inch , flanch ci 3 inch , flanch ci 4 inch , flanch,ci 6 inch , flanch ci rubber packing 2 inch , flanch ci,rubber packing 3 inch , flanch ci rubber packing 4 inch ,,flanch ci rubber packing 6 inch , elbow pvc 2 inch , elbow,pvc 3 inch , elbow pvc 4 inch , elbow pvc 6 inch , elbow,pvc 8 inch , bend pvc 2 inch , bend pvc 3 inch , bend pvc,4 inch , bend pvc 6 inch , bend pvc 8 inch , pvc offset 2,inch , pvc offset 3 inch , pvc offset 4 inch , pvc offset 6,inch , pvc offset 8 inch , leakage coupler double coupler,leakage socket 2 inch , leakage coupler double coupler,leakage socket 2 6 inch , leakage coupler double coupler,leakage socket 2 9 inch , leakage coupler double coupler,leakage socket 2 12 inch , leakage coupler double coupler,leakage socket 2 24 inch , leakage coupler double coupler,leakage socket 2 36 inch , leakage coupler double coupler,leakage socket 3 inch , leakage coupler double coupler,leakage socket 3 6 inch , leakage coupler double coupler,leakage socket 3 9 inch , leakage coupler double coupler,leakage socket 3 12 inch , leakage coupler double coupler,leakage socket 3 24 inch , leakage coupler double coupler,leakage socket 3 36 inch , leakage coupler double coupler,leakage socket 4 inch , leakage coupler double coupler,leakage socket 4 6 inch , leakage coupler double coupler,leakage socket 4 9 inch , leakage coupler double coupler,leakage socket 4 12 inch , leakage coupler double coupler,leakage socket 4 24 inch , leakage coupler double coupler,leakage socket, 4 by 36 inch , leakage coupler double,coupler leakage socket, 6 inch , leakage coupler double,coupler leakage socket, 6 by 6 inch , leakage coupler,double coupler leakage socket, 6 by 9 inch , leakage,coupler double coupler leakage socket, 6 by 12 inch ,,leakage coupler double coupler leakage socket, 6 by 24,inch , leakage coupler double coupler leakage socket, 6 by,36 inch , pvc tee by 10 kg by , 2 by 2 inch , pvc tee by 10,kg by , 3 by 3 inch , pvc tee by 10 kg by , 4 by 4 inch , pvc,tee by 10 kg by , 6 by 6 inch , no. 40 oil, 1 litre , no. 90,oil, 1 litre , c.i. bend, 150 mm , tee, 150 by 150 by 90 mm,, solution, 1 litre pack , tee, 90 by 90 by 90 mm , d-joint,,150 mm by 16 cl by , d-joint, 90 mm , d-joint, 100 mm ,,bend 90, 150 mm , reducer, 150 by 90 mm , pvc bend, 90,mm , flange, 90 mm , sluice valve, 90 mm , telepiece, 90,mm , rubber washer, 90 mm , sluice valve by hamer,company by , 200 mm , telepiece, 200 mm , rubber,washer, 200 mm , nut bolt, 5 by 3 , gasket ring, 200 mm ,,reducer, 90 by 63 mm , tee, 200 by 200 by 200 mm , tee,,250 by 250 by 200 mm , sluice valve, 150 mm , telescope,c.i., 150 mm , rubber packing, 150 mm , gasket ring, 150,mm , sluice valve, 100 mm , telescope, 100 mm , rubber,packing, 100 mm , nut bolt, 4 by 4 , tee, 100 by 100 by,100 mm , d-joint, 200 mm by 10 cl by , reducer c.i., 250,by 200 mm , tee, 200 by 200 by 90 mm , n.r.v. by non-,return valve by , 150 mm , t.c.i., 200 by 200 by 90 mm ,annual rate contract for water supply pipeline materials,and accessories- quantity - 199
supply of - amc for fire fightin , refilling of fe,co2,2kg , refilling of fe,co2,4.5kg , refilling of co2 cartridge,9kg , refilling of gas cartridge,1kg , refilling of gas cartridge,2kg , hydrotesting of 2kg co2 fe , hydrotesting of 4.5kg co2 fe , hydrotesting ust 9 10 kg dcp , hydrotesting ust 25 75kg dcp , hydrostatic testing fire hose , hydrotesting of unloading hose , silica gel , gskt,spw,15mm, 150,316,grf , gskt,spw,20mm, 150,316,grf , gskt,spw,25mm, 150,316l,grf , gskt,spw,40mm, 150,316,grf , gskt,spw,50mm, 150,316,grf , gskt,spw,80mm, 150,304,grf , gskt,spw,100mm, 150,316l,grf , gskt,spw,150mm, 150,316l,grf , gskt,spw,200mm, 150,304,grf , gskt,spw,250mm, 150,316,grf , gland rope supply , testing servicing pv vent,4in , testing servicing pv vent,6in , calibration of pressure guage , cal of thermal relief valve , refilling of scaba cylinder , sply instln of compound gauge , sply instln pressure gauge , cleaning of strainer,10in bel , cleaning of strainer,4in bel , servicing of sprinkler nozzle , sply a of bolt w nut , supply of ss nut bolt washers , sply instln of 8in valve , sply instln of 4in valve , sply instln of 6in valve , sply instln valve, 4in btrfl , gasket sheet,3mm , stnr,y- ty,bw,cs,rf,100mm , stnr,y-ty,bw,cs,rf,80mm , stnr,y- ty,bw,cs,rf,50mm , coating wrapping of pipeline , funnel , helmet,safety , hand gloves,cotton,8 , fire hose box glass , discharge hose,9 10kg dcp , discharge hose, 75kg dcp , discharge hose, 4.5kg dcp , discharge hose, 25kg dcp , hose nozzle, 9 10kg , hose nozzle, 25kg dcp , hose nozzle, 75kg dcp , supply of fire hose,15mt , foam branch pipe , hydrant valve , sand drum with scoop , horn for 2 kg co2 , bend pipe for 2kg co2 , cap washer , safety clip , coupling washer , co2 cartridge for 9 10kg dcp , dry chemical powder , hose box cabinet , fall arrester , safety harness,full body , eye goggle , half cut barrel,ms , barrel,empty,ms , bucket,round , jet nozzle , sply fixg of magnetic sheet , sply and fixg of tsv , nozzle,sprinkler,brass, k41 , nozzle,sprinkler,brass, k30 , spark arrestor, 2in , spark arrestor,3in , spark arrestor,4in , spark arrestor, 6in , sply fixg luminous wind sock , sply and replmnt of glass seal , windsocks stand , vinyl sticker,sop and safety , banner,flex print frntlight , dsgn and sply of acp sheet , safety slogan letter writing , welding of pipes,all dia , refilling of clean agent,2kg , sply and fixg of wheel choke , rope,cotton,14mm , bonding clip , suply n fix flg gt valv 1.5 , sply n fix stnr y type 1.5 , sply n fix btfly vlv waf 4 , first box , nrv 4 , nrv 8 , sply of oil resistant nitrile gloves - fire fighting amc and plant maintenance works at kozhikode ird | quantity - 17052