supply of - circuit breakers for dc operation (q3) - | quantity - 150
View Insights
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 100
supply of fuse cartridge 6 amps 500 v.ac/250 v dc,quick action type 'd'hrc fuse links to is:8187 of make bharat linder,ferraz or bussman.each unit should be emboss/engraved with maker's name,mon th,year and batch no.of manufacturing at a conspicuous place. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lac s ] ] - fuse cartridge
supply of surge arrester for current transformer to spec. no. clw/es/3/0085/a. [ war ranty period: 30 months after the date of delivery ] ] - surge arrester for current transformer
supply of set of items fuse and fuse holder for power car 1) hrc fuse , knife type 6 amps,500v ac, br eaking capacity 80ka, size 35 x 60 x 14, conforming to is-13703-1993 brands: l&t,eton, c&s, ge, siemen s, rbco, havells ,abb only - 2 nos/set. 2) hrc fuse holder, rated current -20 amps, rated voltage- 1000 v olt, conforming to iec: 60269, part-2, similar in all respect to l&t cat.no. st30772 or similar of makes : l& t,eton, c&s, ge, siemens, rbco, havells abb only - 1 no/set. [ warranty period: 30 months after the da te of delivery ] ] - set of items fuse and fuse holder
supply of surge arrester for 3 phase loco as per clw?s specn.no. clw/es/3/0016. clw- vendor- i d: 2100153. [ warranty period: 30 months after the date of delivery ] ] - surge arrester for 3 phase loco
supply of single bottle vaccum circuit breaker (vcb) for electric locomotives as per clw spec. no. cl w/es/c-47/alt-i or equivalent. [ warranty period: 30 months after the date of delivery ] ] - single bottle vaccum circuit breaker.
supply of vacuum circuit breaker [single bottle] for three phase electric locomotives as per clw's specn. no. clw/es/c-47, alt-j or latest. [ warranty period: 30 months after the date of delivery ] ] - vacuum circuit breaker [single bottle] for three phase electric locomotives as per clw's specn. no. clw/es/c-47, alt-j or latest.
supply of set of spares for contactors and mpcb 01 set consists of 01 no. each of items. contactors : 3 p (3no), 415v ac, 50hz, 32a-110v dc coil. motor power - 15 kw confirming to iec 60947-4-1 ac-3. width - 45 mm (+/-) 2 mounting support - din rail. (schneider part no. lc1d32fd). mpcb - 3p, 415v ac, 24-32a, tr ip unit technology - thermal magnetic, breaking capacity (icu) : 10 k a motor power 15ka confirming to iec 60947-4-1 ac-3. width - 45 mm (+/-) 2 mounting support - din rail. (schneider part no. gv2me32). the co ntactor & mpcb spares must be compatible with rmpu control panel in ac emu bhel rakes. make : abb or siemens or schenider. both items should be of same make. the material should be procured from oem or it s authorized dealer. an authorization certificate must be submitted by the firm, during offer, otherwise, the offer will not be evaluated. [ warranty period: 30 months after the date of delivery ] ] - set of spares for contactors and mpcb 01
supply of supply, installation, testing & commissioning of pcb card suitable for automatic changeover cls panel capacity 5 kva to 50 kva as per # rdso specification no ti/spc/psi/cls/0020 or latest with all n ecessary accessories and the modification required .a common card suitable for all core approved makes c ls panel. make-savy/arsh/suntron/sse/asian [ warranty period: 30 months after the date of delivery ] ] - supply, installation, testing & commissioning of pcb card suitable for automatic changeover cls panel
supply of supply, installation, testing & commissioning of pcb card suitable for automatic changeover cls panel capacity 5 kva to 50 kva as per rdso specification no. ti/spc/psi/cls/0020 or latest with all ne cessary accessories and the modification required. a common card suitable for all core approved makes cl s panel. make: savy/arsh/suntron/sse/asian or similar. [ warranty period: 30 months after the date o f delivery ] ] - supply, installation, testing & commiss
supply of 2 amps glass fuse of size: 5x20 mm for switch plate assemblies of all lhb ac & non ac coa ches as per the rcf specification no. edml-64, rev. b, amendment-4 or latest or icf specification no. icf/ edml 007, rev. b or latest. make : ferraz shawmut, cooper bussmann, simens, abb, l&t, protectr on. ] - 1 amp & 2 amps glass fuse of size: 5x20 mm
supply of hrc fuse 25 amp, rated voltage 415-690, breaking capacity 80 ka, utilization category gg clip in offset tag type, is:13703 (part-ii)/ iec:60269-2 suitable for ebc in lhb ac coaches, confirmin g to edts 163 (rev-c) or latest. make brand: bussman/ferraz only. [ warranty period: 30 months af ter the date of delivery ] ] - hrc fuse
supply of air circuit breaker 3 pole, 800 amp, 750v, 50hz cn-cs800c, with 6 no + 6 nc, open ai r execution thermal magnetic mv voltage release dn1e fixed type manually operated, confi rming to rcf specification no. edts 103 rev-d, am-7, suitable for use in control panels of raj dhani /shatabdi trains power cars. accepted make : lauritz knudsen electrical automation (formerl y l&t), abb & ge, as per sr no. 5 of bom of rcf specification no. edts 103 rev-d, am-4, or any rc f/rdso approved make. [ warranty period: 30 months after the date of delivery ] ] - air circuit breaker 3 pole, 800 amp, 750v, cn-cs800c
supply of overhauling kit for mv26 pov port & pvsu port of ercp for kbil make electric ccb syste m of 3-phase locomotives. one set consist of 13 items in 27 nos. as per kbi kit no. xki/kit/03192. anne xure attached. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] - overhauling kit for mv26 pov port & pvsu port of ercp
supply of auxiliary contactor pantograph and vcb (pos no 130.1 136.4) clw spec no clw/es/3/0040 alt-c abb document no - hbtb 585683r1127] [ warranty period: 30 months after the date of delivery ] ] - auxiliary contactor pantograph and vcb (pos no 130.1 136.4) clw spec no clw/es/3/0040 alt-c abb document no - hbtb 585683r1127]
supply of set of as-659 electrical spare kit consists of 03 items in 4 nos. for trident make air dryer, m odel lp2000120 , (1) controller pcb assembly - part no : ad 1224 qty. = 01 no. per set (2) solenoid -part no: a 5079, qty.= 02 nos. per set (3) pressure switch - part no.- ce 484, qty.= 01 no. [ warranty period: 30 months after the date of delivery ] ] - set of as-659 electrical spare kit.
supply of mccb 250 amps,3pole,415 v,50 hz ,breaking current 80 ka confirming is/iec 60947-2:2 003 [ warranty period: 30 months after the date of delivery ] ] - mccb 250 amps,3pole,415 v,50 hz
supply of contactor for 60 kva transformer current rating 95 amp. rated voltage: 690 v ac, main pole: 4, aux. contact: 1no+1nc, control voltage: 168-300v ac means 230 v ac +/- 30% with surge s uppressor, make: abb make af116b-40. schneider (lc1d1150046m5+la4da2u), siemens (3rt2346 -1np30-4aa0) only. note: firm should supply proof of purchase from oem or authorized dealers only. f irm should supply test certificate & guaranty certificate along with supply of item. [ warranty period: 30 months after the date of delivery ] ] - contactor for 60 kva transformer currentcontactor for 60 kva transformer.
supply of trip indication fuse ti 2000 (gsl-2000) of m/s eec. [ warranty period: 30 months after the date of delivery ] ] - trip indication fuse ti 2000
supply of cylindrical type hrc fuse 6 amps, 415 v, size: 14x51 mm, sf90146 gg, 80 ka of wohner / l &t or ge make as mentioned in bill of material of edts-103 rev-d. [ warranty period: 30 months after th e date of delivery ] ] - cylindrical type hrc fuse 6 amps
supply of - moulded case circuit breakers (mccb) conforming to isiec 60947 (part 2) (q2) - | quantity - 48
supply of set of circuit breakers. one set consisting of 02 items 03 nos. each specn/ drg. no.- a) ac circuit breaker 16a 650v 3pole as per clw specn no. clw/es/3/0096 alt-l with latest alteration -0 3nos. cat no. qx-3 ah 8569-16a b) dc circuit breaker 16a 250v dc 1 pole as per clw specn no. clw /es/3/0037 alt-h with latest alter. -03nos cat no. qx1 dh8538-16a offered item make: abb part no. (a ) s803x-16-ah8569 (b) s801x-16-dh8538. make/brand:abb [ warranty period: 30 months after the date of delivery ] ] - set of circuit breakers.
supply of mpcb for exhaust fan 1,2 and 3 wc mbs 25 auxiliary contact (1no+1nc) and t erminal block, rated current: 0.63 amp, thermal release range: 0.4- 0.63 a, rated voltage : 415 v ac, class-10, breaking capacity: 50 ka, pole-3p, cat no. ms116-0.63, hk1-11 of abb or gv2-me04+gv-ae11 of schneider or 3rv2011-0ga10 +3rv2901-1e of siemens or st41892oooo +st41945oooo of l&t make. make- as per bom of lhb switch board cabinet specification no. rdso/ pe/spec/ac/0192-2018 (rev-1) abb, schneider, siemens & l&t only. spec:rdso/pe/spec/ac/0192-2 018 (rev-1) [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] - mpcb for exhaust fan 1,2 and 3 wc mbs 25
supply of : hrc fuse din type lhb ac coaches , current rating 125a , voltage rating 1000v breaking ca pacity 80ka, size nh1l , catetory gb , dimensions similar to siba catalogue no 2028003.125 suitable for fit ment in existingholder of siba , place of installation sif50 to sif55 of switch board cabinet of lhb ac coach es edts -073 as perrdso/pe/spec/ac/0184-2015(rev-2). [ warranty period: 30 months after the date of delivery ] ] - hrc fuse din type lhb ac coaches
supply of mpcb for exhaust fan 1,2 and 3 wc mbs 25 auxiliary contact (1no+1nc) and t erminal block, rated current: 0.63 amp, thermal release range: 0.4- 0.63 a, rated voltage : 415 v ac, class-10, breaking capacity: 50 ka, pole-3p, cat no. ms116-0.63, hk1-11 of abb or gv2-me04+gv-ae11 of schneider or 3rv2011-0ga10 +3rv2901-1e of siemens or st41892oooo +st41945oooo of l&t make. make- as per bom of lhb switch board cabinet specification no. rdso/ pe/spec/ac/0192-2018 (rev-1) abb, schneider, siemens & l&t only. specn: rdso/pe/spec/ac/0192- 2018 (rev-1) [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] - mpcb for exhaust fan 1,2 and 3 wc mbs 25 ......
supply of siemens fuse (male and female) 3na3 832-7y nh00 125 amp,500 v- 120ka for ltt coa ching depot [ warranty period: 30 months after the date of delivery ] ] jr.engineer coaching cla(t) - siemens fuse (male and female)
supply of fuse auxiliary 1000 volts, 50 amps for hb panel of wap-7 & wag-9 three phase locos. to clw spec. no.clw/es/3/0092 alt-d or latest. specn: clw spec. no. clw/es/3/0092 alt-d or latest. note :- latest alteration/specification will be applicable at the time of tender opening. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] - fuse auxiliary 1000 volts, 50 amps for hb panel of wap-7 & wag-9 three phase locos. to clw spec. no.clw/es/3/0092 alt-d or latest. specn: clw spec. no. clw/es/3/0092 alt-d or latest. note:- latest alteration/specification will be applicable at the time of tender opening.
supply of 2 amp glass fuse size 5 x 20 mm for switch plate assembly in lhb type coaches as per edml 064, rev b, am 4 as per attached specification. [ warranty period: 30 months after the date of delivery ] ] - 2 amp glass fuse size 5 x 20 mm for switch plate assembly in lhb type coaches as per edml 064, rev b, am 4.
supply of surge arestor for auxiliary convertor mvr 0.80 -10ka as per abb document no- hawa 300 296r0080 . [ warranty period: 30 months after the date of delivery ] ] - surge arestor for auxiliary convertor mvr 0.80 -10ka as per abb document no- hawa 300296r0080 .
supply of auxiliary contactor pantograph and vcb (pos no 130.1, 136.4) clw spec no clw/es/3/004 0 alt-c, abb document no.- hbtb 585683r1 127. [ warranty period: 30 months after the date of deliv ery ] ] - auxiliary contactor pantograph and vcb (pos no 130.1, 136.4) clw spec no clw/es/3/0040 alt-c, abb document no.- hbtb 585683r1 127.
supply of set of spares for pcb of e-70 brake system as per m/s ftrtipl part, set consists of 02 ite ms in 02 nos.. set details : (1) suppression pcb assembly part no. 025207000 - 01 no./set (2) drive int er lock module assembly part no. 025208000 - 01 no./set. [ warranty period: 30 months after the dat e of delivery ] ] - set of spares for pcb.
supply of hrc fuse link of rating 40 a, 690 v, din type confirming to is:13703-2-1/iec 60269-2 of cate gory gg,size nh00 suitable for lhb ac coaches similar to cat. no. 03915 of m/s. wohner or cat. no.nh00g g69v40 of m/s. ferraz or cat. no.3nv0-00-40a-gg-690v of m/s. koncar or cat. no. 40nhg00b-690 of m/s .eaton or equivalent of m/s siemens / l&t / ge / tc make as per item no.17 and note. 7 of rcf drg. no. l w 71002 alt. h or latest .to be procured from oem or its authorized dealers. [ warranty period: 30 month s after the date of delivery ] ] - hrc fuse link of rating 40 a
supply of residual current circuit breaker (rccb),high immunity type, 25a, four pole (4p) with 30ma s ensitivity ,415v ac, 50hz conforming to is-12640-1/iec-61008-1. test certificate of oem should be submitte d at the time of supply of material. (material to be procured from oem / authorised dealer) simila r to model - cat.no. 411896 of legrand make or cat no. aurad402503 of l&t make or ch425j of hager make or schneider or abb or eaton or siemens or bch [ warranty period: 30 months after the date of delivery ] ] - residual current circuit breaker (rccb)
supply of vb trainset schneider make vcb spare aoh kit as per rdso specification no. rdso/pe/spec/emu/01 96-2019 (latest) along with latest annexure and addendum/corrigendum to m/s. schneider part no. mfr38245 suit able to vb rakes. [ warranty period: 30 months after the date of delivery ] ] - vb trainset schneider make vcb spare aoh kit as per rdso specification no. rdso/pe/spec/emu/0196-2019
supply of hrc fuse link 100 amp.660 vac,tcp-100, two hole fixing bolt offset tag is : 13703-98 co de sfb-8125100. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted : max 8 lacs ] ] - hrc fuse link 100 amp.660 vac,tcp-100
supply of auxiliary switch (8 no + 8 nc ) with crank, part no. as/s of alind make for 25 kv ac single pole outdoor vacuum circuit breaker type vse 5/20. make: alind or any other make or similar make suitable for vacuum circuit breaker of alind make provided in jabalpur division of w est central railway. (firm should integrate the item with the existing system.) ( warranty period : upto 30 months from the date of supply) [ warranty perio d: 30 months after the date of delivery ] ] - auxiliary switch
supply of ioh replacement kit for new 22cb schneider make vcb with new part code no. mfr38246lc_s with additional auxiliary switch. as per annex ure attached mfr38246lc_s. [ warranty period: 30 months after the date of delivery ] ] - ioh replacement kit
supply of set of mpcb of different ratings and capacities, suitable for vb trainset coaches as per attac hed annexure - a, accepted makes - siemens, schneider or abb only. [ warranty period: 30 months after the date of delivery ] ] sr.section engineer(tlac)ajni, - set of mpcb of different ratings and capacities, suitable for vb trainset coaches as per attached annexure - a, accepted makes - siemens, schneider or abb only.
supply of hrc fuse link of rating 40 a, 690 v, din type confirming to is: 13703-2-1/iec 60269-2 of cate gory gg, size nh00 suitable for lhb coaches similar to cat. no. 03915 of rating 40a of m/s wohner or cat. n o. nh00gg69v40 of m/s ferraz or cat. no. 3nv0-00-40a-gg-690v of m/s koncar or cat. no. 40nhg00b-690 of m/s eaton or equiv. of m/s siemens / l&t / ge / tc make as per rcf drawing no: lw71001. oem test rep ort attached along with supply. [ warranty period: 30 months after the date of delivery ] ] - hrc fuse link of rating 40 a