2 Latest Manpower Tenders in Military Engineer Services
Find the latest manpower tenders in military engineer services for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
Category: manpower
Organization: Military Engineer Services
Live Manpower Tenders in Military Engineer Services 2026
1 |Bid Value:₹ 15.18 Lakh |EMD:₹ 30.36 K |23-09-2026 4 Days Left|T247 ID-104166300
...kit and all tp and manpower required at site centrifuging and topping up etc and unit rate quoted shall be deemed to include for the same ii new transformer oil as required shall be measured and paid separatly under respective item as supply only iii the rate quoted by contractor shall deem to be included for three phase generator supply for dehydaration if required iv record of new insulating oil used for replacement and topping up oil in transformer shall be maintained duly signed by rep of contractor and age em, supply only new transformer oil as per is for topup with dielectric strength not less than 60 kv complete all as specified and directed by engineer - in - charge make- savitapower oilhp, ml for hiring of cable fault detector to detect exact position of fault for xlpe pvc ht cable 11000 33000 volts grade heavy duty aluminium conductor of any size complete all as specified and directed by engr-in-charge, ml for fixing in repair end joint kit for 11 kv earthed grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and testing after jointing complete note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed, supply jointing and testing in replacement of indoor type cable end termination joint heat shrinkable suitable for aluminium conductor cable of size 240 sqmm x 3 core to 300 sqmmx 3core 11000 volts grade complete all as specified and directed note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed make- densonraychem3mcabseal, sf in repairs cable jointing kit for 33 kv earthed grade cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed make-densonraychem3mcabseal, ml in repairreplacement for earthing complete with using copper earth plate electrode 600 mmx 600 mmx315 mm thick buried directly in ground earth pit not less than 225 mtr deep below ground level with top edge of the earth plate not less than 150 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 20x3mm copper earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switchcontrol board at another end gi earth lead incased in and including 50 mm dia gi light grade pipe from upper end of earth plate upto equipment with including 20 mm dia bore gi pipe light grade as water pipe from earth chamber to upper edge of the earth plate gi funnel with wire mesh fixed on water pipe and provision of pcc 124 type b1using 20 mm graded stone agg as in pits chamber and rcc pit cover 50 mm thick of precast rcc 124 type b-1 using 20 mm graded stone agg including necessary excavation and earth work in softloose soil all as shown in electric plate no 3 of ssr part-i and testing on completion complete all as specified and directed by engr-in-charge, ml in repairreplacement for earthing complete with using galvanized steel earth plate electrode 600 mmx 600 mmx 60 mm thick buried directly in ground earth pit not less than 225 mtr deep below ground level with top edge of the earth plate not less than 150 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32x6 mm gi earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switchcontrol board at another end gi earth lead incased in and including 50 mm dia gi light grade pipe from upper end of earth plate upto equipment with including 20 mm dia bore gi pipe light grade as water pipe from earth chamber to upper edge of the earth plate gi funnel with wire mesh fixed on water pipe and provision of pcc 124 type b1using 20 mm graded stone agg as in pits chamber and rcc pit cover 50 mm thick of precast rcc 124 type b-1 using 20 mm graded stone agg including necessary excavation and earth work in softloose soil all as shown in electric plate no 3 of ssr part-i and testing on completion complete all as specified and directed by engr-in-charge, sf in repairreplacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduitpipe or fixed to poles or any other indicated situation for loop earthing etc as required by copper strip 20x3 mm all as specified and as directed, sf in repairreplacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduitpipe or fixed to poles or any other indicated situation for loop earthing etc as required by galvanized iron strip 32x6mm complete all as specified and directed, labour for cutting trimming of tree branches up to 80 mm wide all around from the outer face of alignment of 33 kv ht over head electric line which are going touching or falling or acsr conductor poles or near by sub stns etc at any height from gl and making clearance 15m form conductor and removing to a distance up to 100 mtr where directed by engineer-in-charge note- i trimming of the branches on one sides of the conductor ii actual length of cutting will be measured iii the distance as motioned above will be maintained during contract current period same location subject to at least 6 months period between two trimminglopping iv measurement will be taken including all conductor as one only, mlfor preparatiom of old treated steel surface of any description of 33 kv yard and applying one coat of synthetic enamel paint complete all as specified, mlfor preparatiom of old treated pcc plastered surface of wall foundation of 33 kv yard and applying one coat of white wash complete all as specified, clearing away all grass vegetation saplings shrubs brush wood undergrowth roots and trees not exceeding 30 cm girth measured one metre above ground level and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance softloose soil and getting out including sprinkling anti vegitation chemical for complete area with spray machine complete all as specified directed, a line isolator 33 kv horizontal type - servicing of line isolator horizontal break outdoor type including cleaning of contact by ctc liquid proper oiling greasing on contacts moving rod handle for proper function of moveable rod for smooth on off position and checking the incoming and outgoing connection including replacement of terminal lugspg clamps with nut bolts etc and testing with following i meggar testing between phase to phase phase to earth shall be carried out, b ht potential transformer or 33 kv 110 volt outdoor type - cleaning of bushing and terminal of ht potential transformer 33 kv 110 volts outdoor type by ctc liquid and checking of oil level and oil dielectric strength bd test and proper connection checkingtightining of control wiring and testing with following - i meggar testing between phase to phase phase to earth, c ht 33 kv or 11 kv outdoorindoor type current transformer ct cleaning of bushing and terminal by ctc solution of ct 33 kv or 11 kv of any ratio and any type and checking of oil level and oil dielectric strength bdv test and for 11 kv checking of wiring circuits and decarbonising of cablebusbar jointsand proper connection checkingtightining of control wiring and testing with following i testing between phase to phase phase to earth to be carried out by external current injection kit, d 3311 kv vcbbreaker control relay panel 02 nos 33 kv panel - cleaning of control relay panel inside outside and checkingtightningrewiring if required cost of new wire is included in quoted rate all the control cable connection of ct pt vcb meters trivector meter transformer complete and testing with the following - i over current earth fault relay tripping by external current injecting kit on primarysecondary side ii buccholz relay alarm tripping testing iii oil temperature alarm tripping testing iv winding temperature alarm tripping testing v all selector switchesindication lamps such as localremoteonoff accept reset push button indication lamp checkedreplaced if required complete the cost of switchindication lamps will deemed to be included in quoted rate, etransformer 33 11 kv up to 315 mva - cleaning of power transformer 33 11 kv outdoor type externally including all accessories such as conservator tank marshaling box bushings bucholz relay radiator bushings oil level indicator complete and checking the incoming and outgoing terminal connection complete with the following testing - i transformer oil dielectric strength bd voltage test ii buccholz relay alarm trip testing iii oil temprature alarm trip testing iv winding temprature alarm trip testing v meggar testing between hv to earth vi meggar testing between lv to earth vii meggar testing between hv to lv viii earth resistance test for body earthing ix replacement all packing and viewing glass in marshilling box if required, f do fuse 33 kv cleaning of 33kv ht insulators checking the incoming outgoing joint connection replacing with new do fuse of approved rating including replacement of conductor clapms by replacing rusted nut bolts etc and testing with the following - i meggar testing between phase to phase phase to earth, ml for cement concrete for filling in foundations or making good of road pcc floor supports etc type b1 124 using 20 mm graded crushed stone aggregate including necessary form work and fair finishing of exposed surface of concrete facia finish with cement mortar complete all as directed, supply of fuse wire made up of tinned copper of rating 20 amp to 60 amp complete all as specified and directed note- fuse wire shall be taken on charge and record of consumption of same shall be maintained by ageje em, supply of ht insulation tapes roll isi marked for terminating high voltage 3311 kv cables for insulation sealing of connection of wire and cable for bus bar insulation transformer terminal insulation etc complete all as specified and directed, supply and fixing in replacement of danger notice plate 33000 volt and 11000 volt of 16mm thick ms sheet vitreous enamelled white with letters figuers and conventional skull and bones in signal red colour and fixed with ms clamps made out of flat iron 25x3 mm nuts-bolts of approved size for ht 25 x 20 cm and complete all as specified and directed, ml for hardcore of broken stone or boulders gauge of 40mm to 63 mm deposited spread and levelled in layers n exc 15cm thick around ht four poletwo pole structure and transformer area complete all as specified, repair to earth pit earth pit cover of 3311 kv switchyard by using pcc 124 and plastering in cm 13 complete including excavation returning filling and removal etc complete all as specified and directed, supply and laying in replacement of ht high voltage insulation mat size 2mx1m made of elastomeric polymers material having a high insulation registance thus imparting total saety to human being from any leakage current having high insulation registance of class a of size 30 mm thick and 1 m width suitale for 33 kv confirming to is-15652 2006 including pasting of mat with sr-998 by adding thinner as per requirement complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid