Latest Substation Tenders in Military Engineer Services
Find the latest substation tenders in military engineer services for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
Category: Substation
Organization: Military Engineer Services
16 Live Substation Tenders in Military Engineer Services 2026
T247 ID-103639149 |Bid Value:₹ 95.00 Lakh |EMD:₹ 1.68 Lakh |26-09-2026 7 Days Left
dehydration of tranformer oil obtained from transformersvoltage stabilizer etc dielectric strength shall not be less than 50 kv in 25 mm gap electrode after dehydration dehydration of transformer shall be carried out by using electrically operated dehydration machine complete all as specified and as directed note- i centrifuging machine with all tp testing machine of oil required for dehydration shall be arranged by the contractor ii oil required for topping up the transformer will be measured paid separately, supply only ehv transformer oil as per is 335 of 1983 is 1866-2000 for topping up of transformer oil in existing position having dielectric strength not less than 50 kv in 25 mm gap electrode complete all as specified and as directed make -power oilsavitaservo, supply fix and testing in repair wti with 3 mtr capillary lengths as per sample complete all as specified and as directed, supply fix and testing in repair oti with 3 mtr capillary lengths as per complete all as specified and as directed, s f in repair breather assembly for transformer of capacity 5 mva complete all as specified and as directed, supply only silica gel of superior quality of 5 to 10 mm grade complete all as specified and as directed, ml for surface dressing averaging 15 cm depth in softloose soil for cleaning and cuttingremoval of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grassbushes complete all as specified and as directed, material and labour for preparation of old rusted steel surfaces of ht swaged poles of 11m length and applying one coat of synthetic enamel paint up to 12 meter height as per the existing pattern above the pcc coping and one coat of aluminium paint beyond 12 meter height for the rest portion including cross arms brackets and re-writing pole numbers and cutting vegetation growth all around and on the poles up to 1 metre radius complete including replacement of self adhesive fluorescent colour tape as per existing pattern and size complete all as specified and as directed, ditto all as per item no 08 above but ht 4-pole structure complete all as specified and as directed, ditto all as per item no 08 above but ht 2-pole structure complete all as specified and as directed, s f steel tubular swaged pole with cast iron base plate finial tapper plug bolts nuts and screws type 410 sp-55 1100 m long including two coats of aluminium paints over one coat of red oxide primer on external exposed surfaces and two coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole as in repairs complete all as specified and as directed, excavation in trenches not exceeding 15 m in deep not exceeding 15 m wide and getting out in soft loose soil including leveling and ramming complete all as specified and as directed, excavation in trenches not exceeding 15 m in deep not exceeding 3 m wide and getting out in soft loose soil including leveling and ramming complete all as specified and as directed, returning refilling in trenches exvcavated soils including spreading leveling well ramming in layers not exceeding 25 cm thick complete all as specified and as directed, removal of excavated surplus soil to a distance nexceeding 50 m and depositing where directed at a level not exceeding 15 metre above the starting point complete all as specified and as directed, m l pcc 136 type c2 using 40 mm graded crushed stone aggregates as in foundation of poles filling and mass concrete complete all as specified and as directed, m l pcc 124 type b2 using 40 mm graded crushed stone aggregates as in coping of poles filling and mass concrete complete all as specified and as directed, ml clean dry river sand in trenches ducts for cushioning to cable 8 cm below the cable and 15 cm above the cable and measured only 18cm thick sand paid complete all as specified and as directed, supplying laying jointing testing 185 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 33000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 185 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 120 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 95 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supply and laying un-reinforced precast concrete cable class hv type -i flat size 300mm x180mmx40mm complete all as specified and as directed, m l for road cutting including excavation in trenches for laying ht ug cable in pipe not exc 45 cm wide and nexc 60 cm depth or as per site requirement for laying of gi pipe making good the disturbed surfaces with cement concrete 136 type c-1 and top surface neatly finished as per existing to match with the existing complete all as specified note - gi pipe light grade will be paid and measured under separate item the cut excavated surface will be repaired on same day with pcc failing which a penality of rs 500 per day will be recovered from contractor dues, sf steel tubes light grade galvanised with all fitting laid in trenches fixed to wall and floor of 150 mm dia bore for cable protection complete all as specified and as directed, sf steel tubes light grade galvanised with all fitting laid in trenches fixed to wall and floor of 100mm dia bore for cable protection complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 120 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 120 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 33 kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 33 kv ht xlpe cable of size 120 sqmm to 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 11 kv ht xlpe cable of size 120 sqmm to 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 11 kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, ml in repair earthing complete with galvanised steel earth plate 600x600x6mm thick buried directly in ground earth pit not less than 40 mtr deep below ground level with top edge of the plate not less than 325meters below normal ground level connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts nuts check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work gi pipe light grade 40 mm bore for protection of gi strip from earth electrode to and including the earth test point of galvanised ironsteel of size 75x75x 25mm supplying and laying charcoal dust common salt pcc 124 type b1 chamber and ms angle iron frame 40x40x6 cm and rcc cover 40mm thick 124 type b1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars 75mm cc both ways with ms handle 12mm dia pgi funnel and wire mesh 20 mm dia gi pipe light grade for watering all as shown in drawing and connected to earth test point including testing complete all as specified and as directed, material and labour for repairreplacement of earth pit including using pcc 136 type c-1 precast rcc 1153 type a-1 cover slab of size 40x40x 6 cm reinforced with 8mm dia tmt bars 150mm cc both ways with one handle for lifting made out of 8mm dia ms bar embeded in precast cover slab including necessary excavation and earth work in any type of soil complete all as specified and as directed, ml for pin type porcelain white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one one galvanised iron nut suitable for 33 kv grade complete all as specified and as directed, ml for disc type string of 3 disc insulator porcelain white brown or green insulator suitable for 33 kv grade complete all as specified and as directed, sf in repair pin type insulator polymer with hardware fittings grey brown or green suitable for 11000 volts grade complete all as specified and as directed, sf in repair disc type insulator polymer with hardware fittings grey brown or green suitable for 11000 volts grade complete all as specified and as directed, ml cross arms bracing supports clamps and back plates fabricated from structual steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all as specified and as directed, supply and fixing in repair new aluminium conductor steel reinforced acsr of any sizetype stringing and jointing on poles including providing binding wire etc complete all as specified and as directed, supply an fixing danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with msclamps bolts and nuts of approved size for 33 kv ht 25x20cm size complete all as specified and as directed, supply an fixing danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with msclamps bolts and nuts of approved size for 11 kv ht 25x20cm size complete all as specified and as directed, supply and fix in replacement d o drop out fuse unit double stack channel type 3 pole 33 kv channel mounted complete all as specified and as directed, supply and fix in repair polymer type air break switch gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 amps and working pressure 11000 volts with drop out type fuses set 12 insulators three numbers of 400 amp capacity complete including dismentling air break gang operated switches verticalhorizontal mounted including insulator hand operating mechanism for replacement of brokenworn out components and insulators etc all as specified and directed, supply and fixing in repair triple pole double break central rotating banging type isolator horizontal mounting current rating up to 600 amps for 33 kv including post insulators accessories as per existing complete all as specified and as directed, ml for removing and taking out old stone aggreated any size clear all surface their after laying single layer of sand dust in 33 kv mrs yard 11 kv distribution sub station and before laying stone aggregate complete yard including spreading of anti vegetation chemical to prevent abnormal growth of grassbushes complete all as specified and as directed, ml for spreading and levelling evenly 40 mm graded stone aggregated at 33kv main receiving station 11 kv sub station complete all as specified and as directed, material and labour for laying trench cover on cable trenches as per existing at 33 kv11 kv mrs ward made out of rcc 124 type b0 125mm graded stone aggregate, ml lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 11000 volt complete all as specified and as directed, ml lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 33000 volt complete all as specified and as directed, material labour in repair of polymer lighting arrester high tension expluive type complete with all fitting transmission class diescharge capacity 65 kilo amp suitable for 11000 volts complete all as specified and as directed, supply fix testing current transformer ct of 33 kv single phase out door oil cooled ct ratio 100505 amps dual core - one for metering and other for protection having 16 va burdon and class 5p-10 protection and 05 metering complete all as specified and as directed, supply fix testing potential transformer pt of 33 kv single phase outdoor oil cooled pt ratio 33000v3110v3v class 10 having 100 va burdon complete all as specified and as directed, supply fix testing pt protection transformer for 11 kv indoor vcb draw out type 11 kv 11000110 v va-5 class 1 rated friquency 50 hz make- cgl approved vendor all as directed note- complete above said work will be carried out through authorised rep of cg, ml for structural ms frame work half round or other stock section including securing posts and stuts in fencing frame work for gates of substations base frame for equipments including securing bolts posts and struts in fencing including cutting and making shapes as desired drilled holes notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilled bolting or riveting etc and similar work confirming to fe-290 gde e-165 complete all as specified and as directed, sf mild steel screw boltmechine made with hexagonal or square head nexc 5cm but nexc 10 cm dia complete all as specified and as directed, ml for prepration of steel surface of one coat of red oxide and two coat of synthetic enamel paint any description n exc 10 cm in width or grith when unconnected with other painting or when painted in a different complete all as specified and as directed, attending the testing by authorised rep of oem of vcb for attending of servicing overhauling of 11 kv indoor vcb panel including breaker cgabbjyoti make at 3311 kv mrs at ge babina station and including following, supply only led indicating lamps any colour redyellowgreenblue universal voltage for vcb 11 kv of 630400 amps all as per sample complete all as specified and as directed, supply only trip circuit healthy push button with no contacts suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only spring charging motor 230vac dc suitable for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only limit switch suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only microswitch assembly suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only big gear assembly suitable for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only small gear assembly suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only tripping shaft assembly suitable for vcb 11000 volt of 630 400 amps all as per sample and complete all as specified and as directed, supply only closing shaft assembly suitable for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only segment gear assembly suitable for vcb 11000 volt of 630 400 amps all as per sample and complete all as specified and as directed, supply only pt fuse for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only spring charging handle for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only breaker control switch 4 passion for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only ctepoxy type ratio 300-15055a core 115 vaci05 core 2 15 vacl5p10 stc 263 ka 1 sec for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only ctepoxy type ratio 100-5055a core 115 vaci05 core 2 15 vacl5p10 stc 263 ka 1 sec for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only closing coil assembly 30vdc for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only tripping coil assembly 30vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only closing coil assembly 110vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only tripping coil assembly 110vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only plug sockect for vcb 11000 volt of 630400 amps as per sample and complete all as specified and as directed, supply only 8no8nc auxiliary switch for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only space heater 10080w for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only thermostat for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only hrc control fuse 2a 4a 6a 10a for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only complete breaker mechanism assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only onoff push button plate assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only fuse base with carrier up to 32 a for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only timer for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only anti pumping device for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only relay ammeter voltmeter fixing plates with powder coating paint siemens gray rl7032 for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only door knob for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only trip catch assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only set of 06 sleeve for poles for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only set of 06 isolating contacts for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only set of 03 vaccum intrruptor supporting insulators for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only tcs auxiliary relay 24vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed make- lt, supply only auxiliary switch 5 no5 nc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed make- lt, supply only closing coil 30vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only lugs ferules cable teis saddle base 12 sqmm 25 sqmm for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only hooter for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only crc spray bottle for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only epoxy paint for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only 15 multistrandad flexible copper cable 1100v grey colour control wiring for vcb 11000 volt complete all as specified and as directed, ml for spring charging motor modification works under vcb 11000 volt of 630400 complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, ml for modification works under vcb 11000 volt of 630400 to compatable new vcb trolly with existing vcb panel complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, ml for modification fabrication work connection of 11 kv copper bus bar of suitable size suitable lenght as per menufacturer recommendations under vcb 11000 volt of 630400 including copper busbar its jointing and cover with reycam sleeves in existing vcb panel complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, attending the testing by authorised rep of cg for servicingoverhauling of 11 kv rmu 4 way 6way 8way of make- lucyabbmegawin at differenet location under ge babina station complete all as specified and as directed for following, attending the testing by authorised rep of cg for servicingoverhauling of 33 kv cg abb areva make outdoor sf6vcb breakers at 3311 kv mrs at ge babina station all as specified and directed for following, supply only ratchet wheel assembly for 33kv vcb 1250 amp 25 ka as per existing sample complete all as specified and as directed, supply only closing latch assembly for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only tripping latch assembly for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only set up o ring for pole for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only dc auxiliary 30v dc contactor for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only motor contactor 30v dc for 33kv vcb 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only limit switch for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only closing coil assembly 30 v dc for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only tripping coil assembly 30 v dc for 33kv vcb 1250 630400 amp as per existing sample complete all as specified and as directed, supply only spring charging motor 230 vacdc for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only spring charging gear assembly for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only small gear assembly for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only anti pumping device for 33 kv vcb 1250 630400 amps all as per existing sample complete all as specified and as directed, supply only complete pole assembly 33 kv outdoor type all as per existing sample complete all as specified and as directed, supply only breaker charging complete mechanism 33 kv outdoor type all as per existing sample complete all as specified and as directed, testing of outdoor ct pt connection marshaling box with tbs channels for 33 kv vcb control connection complete all as specified and as directed, supply fixing installation and testing in repair power pack unit for battery backup 230 vac 30 vdc suitable for existing cgabb make indoor vcb panel as recommanded by oem complete all as specified and as directed, supply fixing installation and testing in repair power pack unit for battery backup 230 vac 110 vdc suitable for existing cgabb make indoor vcb panel as recommanded by oem complete all as specified and as directed, supply fixing installation and testing in repair 3 phase over current 01 earth fault relay in existing 11 kv indoor vcb panel with high set with idmt and inst characteristics having aux supply v of 20-110v dc rated volt 250 vac 30 or 110 vdc universal wide range as per site requirement complete all as specified and as directed make- cg model - cg14n or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair 3 phase over current 01 earth fault relay in existing 11 kv indoor vcb panel with high set with idmt and inst characteristics having aux supply v of 24 to 240 v acdc rated volt 250 vac 30 or 110 vdc universal wide range as per site requirement complete make- lt model - mc61a-nx cat no mc61anx4000 or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair rej601 feeder protection inrush current relay abb make in existing 33 kv and 11 kv indoor vcb panel with over current short circuit earth fault inrush current instantaneous protection features ct secondary 1 a 5a universal wide range auxiliary voltage universal acdc wide range site selectable range make- abb model rej601 or equevalent of seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair aegis a131d1 feeder protection inrush current relay cg make in existing 33 kv and 11 kv indoor vcb panel with over current short circuit earth fault inrush current instantaneous protection features ct secondary 1 a 5a universal wide range auxiliary voltage universal acdc wide range site selectable range make- cg model no aegis a131d1 or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair wtioti alarm relay for transfomer protection in existing 33 kv control panel as sample complete all as specified and as directed make- cg cs abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair wtioti trip relay for transfomer protection in existing 33 kv control panel as sample complete all as specified and as directed make- cg cs abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair 86 master trip relay in existing 33 kv or 11 kv indoor vcb control panel with 30 vdc complete all as specified and as directed make- cs cg abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, attending and testing by service engineer to carry out priodical on site testing of 3311kv 02 nos 5 mva 01 nos 125 mva transformer by authorised agency at 3311 kv mrs at ge babina station are as under - a ir value test b ratio test c magnetic core balance test d open circuit test e vector group test f short circuit test g no load current test note- a all necessary arrangement at the site of testing quipment for the testing will be responsibility of the contractor and rate for the same will be included in quoated rate b after the testing of transformer test report will be submitted to the department necessary recommandation suggestion also be mentioned in report if any, sf in repairreplacement voltmeter digital type with selector switch of size 96x96mm 01 phase rating complete all as specified and as directed make- elmeasure conzervelt, sf in repairreplacement voltmeter digital type with selector switch of size 96x50mm 3 phase 03 wire rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair replacement ammeter digital type with selector switch of size 96 x 96 mm 01 phase rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair repalcment ammeter digital type with selector switch of size 96 x 50 mm 3 phase 3 wire rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair replacement multifunctional meter of size 96 x 96 mm rating complete all as specified and as directed make- elmeasure conzervelt, supply fixed installed and testing in repair replacement em7230 demand controller cl 10 rs485 in existing 11 kv indoor vcb panel complete all as specified and as directed make- schneiderltabb, sf in repair breaker control switch trip-neutral-close tnc with 2no 2nc spr rtn for 33 kv control panel cat part no 72009 lt, ml earth continuity conductor or main earthing lead 32 x 6 mm galvanized iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed, ml framed work as in doors or gates of angle or other section with gusset plates rails braces etc complete drilled for fixing of steel heeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete fe 410 wgde e-250 complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 12m x 2m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 12m x 3m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 15m x 3m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 15m x 4m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 6m x 07m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf retro reflective sign board made up with 12 mm thick stainless steel sheet of which both sides shall be fully covered with high intensity prismatic hip retro reflecting sheeting of approved specification asper morth having approved message matter and base fully processed by pressure sensitive equipment of approval brand avery dennison3 m fixed hanging on sub station fencing on stainless steel frame makeup of ss as described complete all as specified and as directed, material and labour for repairmaint of trolly of trolly mounted transformer including oiling greasing of moving parts checking repairing make fuctional of punture tyre of trolly and painting of complete trolly with synthetic enamel paint with existing pattern or as directed after cleaing of oily surface of trolly complete all as specified and as directed, material and labour for preparation of old rusted steel surfaces of complete 33 kv yard including ht 2 pole 4 pole structure of 11m length out door ctpt steel structure outdoor vcb steel structure islolator do fuse structure etcas per the existing pattern above the pcc coping with two coat of aluminium paint on complete steel structure and pcc coping painted by applying one coat of synthetic enamel paint complete all as specified and as directed, 12 core 25 sqmm, 6 core 25 sqmm, 4 core 25 sqmm, supply and fix in replecemnet of automatic fcbc and trickle battery charger cum tripping unit 30 vdc 165 ah for 33 kv and 11 kv protection equipment with comprising of following- electrical specification a ac input voltage 230 v range 180v to 264 v b ac input frequency normal 50 hz - 3 hz c dc output volt normal for load 30vdc d 20 amps total current output capacity battery type- a lead acidsmfvlrs b indications for mains supply float charging boost charging ac volt meter dc volt meter dc fail ac fail alarm dc amp meter for load dc amp meter for charging protection- a circuit breaker for mains incoming supply circuit breaker for output load over load protection ac short circuit protection battery reverse polarity low high volatage protection housing and enclosure- a heavy duty sheet steel enclosure finished with powder coated paint floor mounted operation a automannual control cccv close loop rectifier full wave half controlled bridge element fuse protection for rectifier element fuse failsure relay dc earth fault relay alarm annunciation dual float charger option note- i the internal control wiring of battery charger should ber carried out by susing suitable size of multistranded frls copper conductor cable with lugs ii all necessary connection battery bank to vcbs should be carried out by using suitable size of copper wire complete, s f in repair of vrla battery bank 30v 02 v x 15 nos cell 100 ah 02 v with vrla battery rack including connection with necessary suitable copper cable or bus bar strip complete all as specified and as directed make - exideamronluminous, testing of earth resistance of existing earth pit as and when required as per is 3043 1987 ssr part-i para 19146 using earth resistance testing equipments as directed and producing the test result for recording purpose complete all as specified and as directed note - 1the contractor shall be asked to carry out the earth test as completely 2 testing of each earth pit shall be measured as one unit 3all test result to be entered in a register properly bound and covered and to be submitted to the engr-in-charge during payment 4 for the purpose of testing contractor shall supply all equipments and apparatusinstruments at his own cost without any extra claim, testing of battery of existing battery bank and battery charger as and when required using testing equipments if required changing of terminals greasing of terminals and pouring of distilled water as directed and producing the test result for recording purpose complete all as specified and as directed by the engr in charge note 1the contractor shall be asked to carry out the battery test as completely 2 testing of all battery in the battery bank shall be measured as one unit 3 all test result to be entered in a register properly bound and covered and to be submitted to the engr-in-charge during payment 4 for the purpose of testing contractor shall supply all equipments and apparatusinstruments at his own cost without any extra claim, testing repairing and making functional of existing 11 kv ht capacitor bank make abb including all necessary spare parts of capacitor as required for making functional of ht capacitor bank complete all as specified and as directed note- i reparing work of ht capacitor bank will be carried out through authorised and specialised agency of similar field ii submit the test report to department before starting and after completion of repair work with functioning of ht capacitor bank and submit their recommendations if any for further improvement of the system iii 11 kv ht capacitor if required for replacement shall be measured and paid separately under respective item of schedule here in after as supply only, supply only do fuse elementwire suitable for 33 kv 5 to 100 amp, supply only do fuse elementwire suitable for 11 kv 5 to 200 amp, s f abc power portable wheeled extinguishers with class a b c and electically started fires packed with 50 and 90 map concentration state of the art pressure gauge quick powerful and reliable fire fighting system with 25 kg ms sp red make cease fire cat part no cf-001167 or equivalent to other make complete all as specified and as directed, s f abc power portable wheeled extinguishers with class a b c and electically started fires packed with 50 and 90 map concentration state of the art pressure gauge quick powerful and reliable fire fighting system with 50 kg ms sp red make cease fire cat part no cf-001167 or equivalent to other make complete all as specified and as directed, s f power portable class ceasefire multimax state of the art pressure gauge quick powerful and reliable fire fighting system with 09kg make cease fire or equivalent to other make complete all as specified and as directed, refilling of dry chemical powder extinguisher stored pressure type with change of nozzle pipe pressure gauge 09 kg complete all as specified and as directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid