suply installation testing and commissioning of do meter online with sensor and transmitter sitc makes hach endress plus hauser forbes marshall, suply installation testing and commissioning of level sensors radarultrasonic sitc 3-yr warranty makes siemens vega endress plus hauser, n s suply installation testing and commissioning of monitoring screens industrial display 32 ip65 anti-glare with inbuilt processor for live data preview qty 3 nos installed at i stp site ii je office with internet iii sdo-specified location with internet, cctv integration camera ip66 ir-enabled nvr-ready as per entire satisfation to the engineer in charge, fire extingisher abc type, supply of monoblock pump 2 hp capacity, s-worm wheel worm shaft s sprindle tr 65x12-anr 106685 s bearing and seals for sbr decanter plc decantor box, supplying and installing of feeding pump for poly dosing, providing and fixing diffuser 3 layer 4 layer in the sbr basin membrane in the sbr basin, supply of junction box ss 316 tp-68 protection, supplying and installing of sludge sump difuser membrane epdm, lab equipments supply of distillation plant filter assembly volumetric flask measuring cylinder 1000 ml 500 ml 100 ml do sensor meter beaker 1000 ml 500 ml 100 ml weighing balance upto 4 digit accuracy tds meter, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 2600 m as per the indicated requirements of discharge in lpm and power capacity in bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect for stp 1 no 18000 lpm 26 mtr head, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 2400 m as per the indicated requirements of discharge in lpm and power capacity in bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect for ips 6750 lpm 24 mtr head, 75 hp ras and sas submersible pump set including 12 mtr cable with auto coupling assembly, supplying erection testing of fully automatic electric control panel board for twells in pump chamber consisting of ms sheet of thickness 14 gauge duly painted box type floor mounted made of angle frame containing 1 no fully automatic air brake starter suitable for motor of the following capacity min switch of suitable range with hrc fuse 1 no volt meter 0 to 500 volts 1 no amp meter of 0 to 100 amp 3 sets of indicating lamp capacitor of suitable capacity and 1 no single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in electric control panel board complete in all respect as per specification given in schedule no ii including mcb suitable capacitor wooden box etc as per site requirement complete in all respect 75 hp, horticulture equipements 1lawn mower petrol electric battery 2brush cutter string trimmer 3knapsack sprayer 1620 l 4hand weeder khurpi manual weeding 45 5sickle grass cutter 6wheelbarrow baskets 7hand tools spade khurpi rake, ns item -supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 2600 m as per the indicated requirements of discharge in lpm and power capacity in bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect for ips 6750 lpm 26 mtr head, supplying and installing wall mounted gas chlorinator system vacuume regulator flow meter rota meter glass tube chloine pressure gauge vacuum tubing cylinder opening key, supply of 100hp air cooled panel with rotary handle 3nos power contactors ac3 duty rated at 60 ambient suitable capacity power capacitors high end electronic relay for uvov sppelr ph failure unbalance dry run preventer level controller a plus ass v plus vss with selector switch kwh meter led indicators bch make
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
design supply installation and testing of lt control panel with change-over maindg and soft starters vfd along with distribution panel in enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay push button red plus green with element indicator onoff aluminum bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 mod bus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensor less vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensor less vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensor less 1 0 to 120hz in sensor less 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required 375 lps 22500 lpm x 42 mtr, supplying designing erection testing and commissioning of non clog for sewerage having head 42 m as per the indicated requirements of discharge in 375 lps 22500 lpm and power capacity as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
providing supplying installation testing and commissioning of oil cooled air cooled as applicable automatic servo controlled voltage stabilizer of required capacity as per site load requirement suitable for three phase 415v 50 hz ac supply complete in all respects, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 16 m as per the indicated requirements of discharge in 18000 lpm as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect 100 hp, supplying erection testing and commissioning of horizontal non clog motor for sewerage having head 16 m as per the indicated requirements of discharge in 18000 lpm and power capacity as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect 100 hp, design supply installation and testing of vfd along with distribution panel in enclosure for enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and nonload bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required 18000 lpm x 16 mtr head 100 hp
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 65hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for non clog submersible pump, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 11458 lpm and power capacity in 65 bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect, supplying erection testing and commissioning of horizontal motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 14000 lpm and power capacity in 80 bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having 60 hp as per the indicated requirements of discharge in lpm and power capacity in bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect discharge capacity - power capacity bhp -100 hp at shadipur ips, design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 100 hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for non clog submersible pump, design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 80 hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for horizontal non clog pump 80 hp
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid