Find the latest fuse tenders in south central railway for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
supply of hrc fuse 25 amp, rated voltage 415-690, breaking capacity 80 ka, utilization category gg clip in offset ta g type, is:13703 (part-ii)/ iec:60269-2 suitable for ebc in lhb ac coaches, confirming to edts 163 (rev-c) or latest.mak es: bussmann, ferraz as per bill of material of rcf specification no.edts163, (rev-c) or latest. [ warranty period: 30 months after the date of delivery ] ] sse/ac/chz, scr
View Insights
supply of cylindrical hrc fuse link 2 amps, 500 v ac, size: 10x38 mm, breaking capacity 120 ka gg/g l, to iec 60269- 2 suitable for secondary circuit of 100va control transformer of non ac lhb coaches confo rming to rdso spec. no. rdso/pe/ spec/d/0184-2015, (rev.1) required makes: eaton, siba, bussman, efe n, ferraz, eti, l&t, seimens & abb as per s. no.5 of bom (annexure d) [ warranty period: 30 months aft er the date of delivery ] ]
supply of d.o.fuse element,1 amp capacity for 25 kv dropout fuse switch conforming clause 4.2 of rd so specification no. eti/psi/14 (1/86)rev-1(apr-87). [ warranty period: 30 months after the date of delivery ] ]
supply of set of items fuse and fuse holder for power car 1) hrc fuse , knife type 6 amps,500v ac, br eaking capacity 80ka, size 35 x 60 x 14, conforming to is-13703-1993 brands: l&t,eton, c&s, ge, siemen s, rbco, havells ,abb only - 2 nos/set. 2) hrc fuse holder, rated current -20 amps, rated voltage- 1000 v olt, conforming to iec: 60269, part-2, similar in all respect to l&t cat.no. st30772 or similar of makes : l& t,eton, c&s, ge, siemens, rbco, havells abb only - 1 no/set. [ warranty period: 30 months after the da te of delivery ] ] - set of items fuse and fuse holder
supply of trip indication fuse ti 2000 (gsl-2000) of m/s eec. [ warranty period: 30 months after the date of delivery ] ] - trip indication fuse ti 2000
supply of hrc fuse link of rating 40 a, 690 v, din type confirming to is:13703-2-1/iec 60269-2 of cate gory gg,size nh00 suitable for lhb ac coaches similar to cat. no. 03915 of m/s. wohner or cat. no.nh00g g69v40 of m/s. ferraz or cat. no.3nv0-00-40a-gg-690v of m/s. koncar or cat. no. 40nhg00b-690 of m/s .eaton or equivalent of m/s siemens / l&t / ge / tc make as per item no.17 and note. 7 of rcf drg. no. l w 71002 alt. h or latest .to be procured from oem or its authorized dealers. [ warranty period: 30 month s after the date of delivery ] ] - hrc fuse link of rating 40 a
supply of mcb 10 a double pole 130 v-dc, without external terminal suitable for din power channel fit ment as per rdso spec. no. -e-12/1/04 of march 1992 with amendment 1 of june 1993 (with punching of in dian railway emblem & rdso) make: legrand/l&t/c&s/havells/schneider/abb. [ warranty period: 30 mo nths after the date of delivery ] ]
supply of mcb 16amps, 2 pole, 250v dc, type-c with breaking capacity of 10ka as per clause 5.2.4 of is/iec 60898: part 3 (latest) generally conforming to is/iec 60898: part 3 (latest) [circuit - breakers for dc operations] is/iec-60947: part 2 (latest) [low - voltage switchgear and control gear (circuit - breakers) [ warranty period: 30 months after the date of delivery ] ]
supply of miniature circuit breaker (mcb) 2.5 amps 110/130v dc single pole with extended termi nal as per rdso drg. no. skel-3700, alt-1 and skel-4034 alt-1 to rdso specification no.spec/e-12/1/ 04 of 92 with amendment no. 01 of june 1993 [ warranty period: 30 months after the date of deliv ery ] ] mechanical &
supply of circuit breaker tcc electric blower motor / filter blower motor - 30amp t o dlw drg. no. 40051839 alt. a. or latest. and to dlw part.no: 18310321 for wdp4/wdg4 loc os. [ warranty period: 30 months after the date of delivery ] ]
supply of mcb 06a dc, sp, c-type, protection ip:20, minimum voltage: 200vdc, breaking capacity 4ka to is/iec60898: part 3 (latest) f or dc operations [ warranty period: 30 months after the date of delivery ] ]
supply of mcb 20a double pole 130 v dc, with extended terminal suitable for din power channel fitme nt as per rdso spec. no. - e-12/1/04 or latest, for use in 1400hp demu. makes: legrand/havells/schnieder/ abb only. note: oem/authorized dealers to quote along with necessary authorization certificate/ purchase proof/authorized test report. [ warranty period: 30 months after the date of delivery ] ]
supply of isi marked miniature circuit breaker single pole with neutral 16 a capacity with breakin g capacity of 10ka, conforming to is/iec :60898 [ warranty period: 30 months after the date of deliv ery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs ] ]
supply of mpcb (motor protection circuit breaker) of current rating: 0.63 amps, thermal release range- 0.4 to 0.63amps, class-10, breaking capacity: 50ka, 3 pole, voltage rating-415 volt ac with 01 no + 01nc auxiliary contact block as per abb catalogue no:ms116- 0.63 + hk1-11, schneider catalogue no.gv2-me04 +gv-ae11, siemens catalogue no.3rv2011-0ga10+3rv2901-1e, l&t catalogue no. st418920000+st419 450000, eaton catalogue no.pkzm01-0.63+nhi-e-11-pkzo and confirming to rdso specification no. rdso/ pe/spec/ac/0184-2015 (rev-1) and rdso lr. no. el /7.1.108/mssbc, dt.17/09/21. spec: rdso specificatio n no. rdso/pe/spec/ac/0184-2015(rev-1) and rdso lr. no. el /7.1.108/mssbc,dt.17/09/21. [ warranty period: 30 months after the date of delivery ] ]
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 800
supply of - circuit breakers for dc operation (q3) - | quantity - 150
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 100
supply of set of mcb as per is : 8828-1996, iec 898-1995. breaking capacity 10 ka. 240-415v ac 50 hz with extendedterminals din type make- havells/hager/ legrand/ schneider/ siemens/ abb / l & t [larsen and turbo]/control and switch gear [c&s]/ cgl. one set consisting the following.(1) m cb (single pole) 10 amps - 5 nos.(2) mcb(single pole) 15 amps - 1 no. (3) mcb (single pole) 35 amps - 2 nos. [ warranty period: 30 months after the date of delivery ] ] mechanical & - set of mcb as per is : 8828-1996, iec 898-1995. breaking capacity 10 ka. 240- 415v ac 50 hz with extendedterminals din type make- havells/hager/ legrand/ schneider/ siemens/ abb/ l & t [larsen and turbo]/control and switch gear [c&s]/ cgl. one set consisting the following.(1) mcb (single pole) 10 amps - 5 nos.(2) mcb(single pole) 15 amps - 1 no. (3) mcb (single pole) 35 amps - 2 nos.
supply of vacuum circuit breaker [single bottle] for three phase electric locomotives as per clw's specn. no. clw/es/c-47, alt-j or latest. [ warranty period: 30 months after the date of delivery ] ] - vacuum circuit breaker [single bottle] for three phase electric locomotives as per clw's specn. no. clw/es/c-47, alt-j or latest.
supply of mcb, single pole, 130v dc, rated short-circuit breaking capacity of 6ka, c - type, 03a, din r ail mounting type confirming to iec 60947-2 of makes abb, l&t, legrand, havells, hager,siemens, c& s, schneider. [ warranty period: 30 months after the date of delivery ] ] - mcb 03a dc, sp, c-type
supply of mcb 25 amp, d curve, 3 pole, rated voltage: 415 v ac, breaking capacity: 10 ka suitable for switch board cabinet of lhb ac coaches as per common bill of material of rdso letter no.el/7.1.108/mss bc dated 17.09.2021 [ warranty period: 30 months after the date of delivery ] ] - mcb 25 amp, d curve
supply of residual current circuit breaker (rccb),high immunity type, 25a, four pole (4p) with 30ma s ensitivity ,415v ac, 50hz conforming to is-12640-1/iec-61008-1. test certificate of oem should be submitte d at the time of supply of material. (material to be procured from oem / authorised dealer) simila r to model - cat.no. 411896 of legrand make or cat no. aurad402503 of l&t make or ch425j of hager make or schneider or abb or eaton or siemens or bch [ warranty period: 30 months after the date of delivery ] ] - residual current circuit breaker (rccb)