Find the latest mcb tenders in south coast railway for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
supply of supply of set of mccbs as per specification details attached at annexure-i and set details are mentioned below. 1) 125a. qty/set. = 01 no. 2) 160a. qty/set. = 01 no. 3) 250a. qty/set. = 01 no. 4) 300a. qty/set. = 01 no. 5) 40 0a. qty/set. = 01 no. makes: l&t or legrand or havells or schneider or its equivalent. note:bidders must mention the specific make of the offered material while participating in the tender, if not offer will not be considered. [ warranty pe riod: 30 months after the date of delivery ] ]
View Insights
supply of miniature circuit breaker (mcb) 2.5 amps 110/130v dc single pole with extended terminal as per rdso drg. no. skel-3700, alt-1 and skel-4034 alt-1 to rdso specification no.spec/e-12/1/04 of 92 with amen dment no. 01 of june 1993. [ warranty period: 30 months after the date of delivery ] ] carriage repair workshop tpty,
supply of auxiliary contactor pantograph and vcb (pos no 130.1, 136.4) clw spec no clw/es/3/0 040 alt-a or latest, abb document no- hbtb 585683r1127 or latest. ]
supply of set of bottle type high rupturing capacity [hrc] fuses as per clw spec.no.clw/es/f-8/e or latest and c onfirming to clw drg. no. clw/es/sk-1/f8 with latest alteration. each set consists of three items as : 1.fuse 16 amps - 2nos. 2.fuse 35 amps -1 nos. 3.fuse 6 amps -3 nos. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] diesel stores depot guntakal,
supply of rcbo (residual current circuit breaker with over current protection) , 4 pole, 16 amps, d c urve with breaking capacity 10 ka at 415v,50 hz, 30ma residual current, impulse current withstand at 8/2 0microsec pulses=3ka , rdso file no: rdso-pe0peb(nsbc)/1/2020-ed/psemu/rdso part no?s of oems: p art no: a9n4p16d + a9v61440 of m/s schneider, m/s legrand, m/s siemens, m/s abb,m/s lk, m/s l&t. [ w arranty period: 30 months after the date of delivery ] ]
supply of set of fuse gauge piece suitable for bl or viral make fuse units as per spec. no. clw/es/f8 alt c or lates t if any for 6a, 10a, 16a fuse units and spec. no. clw/es/f1/l or latest if any for 35a fuse unit. set consisting of (1) 6a f use. qty/set. = 200 nos., (2) 10a fuse. qty/set. = 100 nos., (3) 16a fuse. qty/set. = 100 nos., (4) 35a fuse. qty/set. = 10 0 nos. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
supply of supply of high-voltage hrc fuse din type, 25a, 1000v ac, size nh000m, breaking capacity 120 ka,con%ufb01rming to is: 13703/iec 269-2. it tender title is suitable for non-ac lhb coaches of switchboard cabinets. makes (as per bill of material edts -355 rev-1, s.no.1 to 6) makes:siba, efen, eti, ferraz, siemens, bussmann, schneider and l&t only. 2. item details s.no. pl code item stock / ordering consider approving inspection currency estimated (group) type nonstock for eval agency agency allowed rate gst(y/n) 1 428100750079 goods (y) non stock --- yes
supply of supply of cylindrical hrc fuse link 2 amps, 500v ac, size 10x38 mm breaking capacity 120k a confirming to iec 60269-2 suitable for secondary circuit of 100va control transformer of non-ac lhb coa ches conf to rdso spec.no. rdso/pe/spec/ac/0203-2020 (rev.0) makes: bussmaan (eaton), l & t, siemen s, siba, ferraz or its equivalent. note:- one sample to be got approved before bulk supply. [ warranty per iod: 30 months after the date of delivery ] ] - cylindrical hrc fuse link 2 amps, 500v ac, size 10x38 mm breaking capacity 120ka confirming to iec 60269-2 suitable for secondary circuit of 100va control transformer of non-ac lhb coaches
supply of supply of hrc fuse link (low voltage), din type, current rating 100a, 500v ac, breaking cap 1 00ka, conforming to to is:13703 pt.2 & rdso spec.no.rdso/pe/spec/ac0184-2015 (rev.1) suitable for use in switch board cabinet of lhb ac coaches. makes :- abb or wohner or eaton bussman or l&t. [ warranty period: 30 months after the date of delivery ] ] - hrc fuse link (low voltage), din type, current rating 100a, 500v ac, breaking cap 100ka, conforming to to is:13703 pt.2 & rdso spec.no.rdso/pe/spec/ac0184- 2015 (rev.1)
supply of air circuit breaker(acb) suitable for lhb power car of system voltage-750 v , ca pacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protect ion , thermal ,magnetic release, 6 no+ 6 nc aux contact block and draw-out acbs terminal a daptors) similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d, am-07 or latest, make- lauritz knudsen formely l&t /abb /ge only. note: sample sho uld be got approved before bulk supply. only oem or its authorized dealers to participate [ warranty peri od: 30 months after the date of delivery ] ] - air circuit breaker(acb) suitable for lhb power car of system voltage- 750 v , capacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protection , thermal ,magnetic release, 6 no+ 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d, am-07 or latest, make- lauritz knudsen formely l&t /abb /ge only. note: sample should be got approved before bulk supply. only oem or its authorized dealers to participate
supply of 25a rccb four pole 30ma residual current circuit breaker. accepted makes: schneider/siem ens/abb/l&t/legrand only [ warranty period: 30 months after the date of delivery ] ] - 25a rccb four pole 30ma residual current circuit breaker. accepted makes: schneider/siemens/abb/l&t/legrand only