Find the latest fuse tenders in southern railway for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
supply of clip on hrc fuse link with staggered tag 20 amps ns type 80 ka breaking capacity at 5 00 v for ebc of lhb ac coaches, confirming to is:13703 (part no. 2)/ iec:60269-2 as per edts no.163 (rev. c) or latest. makes acceptable :siemens, lauritz knudsen (formerly l&t), ge, eaton bussm ann, siba, ferraz, eti, wohner or any other rdso/icf/rcf approved makes only. oem or their auth orized dealers only to quote with documentary evidence. [ warranty period: 30 months after the dat e of delivery ] ] gsd/per, sr
View Insights
supply of battery fuse box negative for lhb type ac eog coaches as per rcf drawing no. lw 710 02 alt. 'j'or latest. [ warranty period: 30 months after the date of delivery ] ] csd/per, sr
supply of set of fuses, set consists of 02 items as given below: (1) hrc fuse with fuse gauge piece link 10 amps, 500 v ac and 250v dc bottle type as per clw specn. no. clw/es/f-8 ald - d - 01 no/set. (2) hrc fuse with fuse gauge piece link 2 amps.500v ac and 250v dc bottle type as per clw specn.clw/es/f-8 ald-d - 01 no/set [ warranty period: 30 m onths after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
supply of high voltage hrc fuse din type 25a, 1000 v ac, gb, size: nh000m, without holder conf orming to is:13703 of type /make: article no. 20 386 03 of siba or equivalent efen / ferraz / eti /sie mens / bussmann / schneider / ge /l&t make as per annexure 'a' of rcf specification no. edts 355, rev.01.offers from oem or their authorized dealers are only accepted. [ warranty period: 30 month s after the date of delivery ] ] amm/gsd/ed, sr
supply of hrc fuse link (din type), rated current 25a without holder, rated voltage 500v, breaking capacity 100ka for providin g in lhb type non ac coaches as per rdso specn. no. rdso/pe/spec/0184-2015 (rev-1), bom (bill of material) item no.18. accept ed makes: siemens, wohner-italweber, abb, eaton and lk (l&t). [ warranty period: 12 months after the date of delivery ] ]
supply of trip indicator fuse link ti 1200-bi for rectifier of emu /memo, having dimension (a) length of fuse = 104 mm, (b) cap dia (top) = 7.3 mm, (c) length of cap (top) = 20 mm, (d) cap dia (bottom)=6.4 mm, (e) len gth of cap (bottom) = 5.8 mm as per spec ti 1200-bi. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 l acs ] ]
supply of supply of hrc fuse cylindrical type 6 amps 500 volts ac, size:10x38, breaking capacity 120 ka, co nfirming to is:iec 60269 & rcf edts-355, suitable for switch board cabinet of non-ac lhb coaches. make: as per rdso spec. no. rdso/pe/spec/ tl/0195- 019(rev.0) s. no. 51 pg.33 - bussmann (eaton)/ siemens/ l&t/ siba/fe rraz/ eti/ abb/ makes only will be accepted. oem or authorized dealers only to quote with documentary evidence. supplier to ensure that the offered product is supplied with valid oem`s warranty certificate. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 la cs ] ]
supply of fuse base rated current 160 amps, rated voltage 690 v ac, size nh00 to wohner catalogue no. 03760 or siemens catalogue no: 3nh3030-0rc, conforming to is 13703 (part 2 / sec.2) - 1993. makes siemens/ wohner / italweber/ ferraz/ bussmann/ schneider/ ge/ l&t/ efen/ eti/ siba only accepted. oem o r authorized dealers only to quote with documentary evidence. [ warranty period: 12 months after the da te of delivery ] ] - fuse base rated current 160 amps, rated
supply of 5 in 1 switch socket (with shutter ), one fuse and one indicator combined, suitable for supplying 16/6 amp load, 2 30 v ; colour ivory or white as per is: 3854/1997 or latest, with four holes for fixing without junction box as is 3854/1997 or lates t & ancher by panasonic product code no 14618 or anchor/gm/fibros/kundan make. [ warranty period: 30 months after th e date of delivery ] ] - procurement of 5 in 1 switch socket,
supply of switch plate assembly complete with polycarbonate cover frame and powder coated steel pl ate with (i) on / off switch -1nos (ii) 3 pin socket 6 a, 250v ac - 1 no, (iii) 2 a glass fuse of m/s. ferraz s hawmut /cooper bussman / equivalent (with fuse holder)- 1 no.as per rcf specification no. edml - 064 rev.b, am - 4, corr. 1, table 10, sl. no. 7 with rcf drawing no. lw74202,alt.f, item no 16 suitable for lhb ac coaches. make acceptable: oswin, sks, ssk, havells, cpl. oem or authorized dealers only to quote wi th documentary evidence. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] - set of switch plate assembly complete fo
supply of - switch disconnectors and fuse combination units (switch fuse unit) conforming to isiec 60947 (part 3) (q2) - | quantity - 5
supply of printed circuit board for 110v,450mm sweep (bldc) universal brushless ac/dc railway carriag e fan confirming to rdso specificationno:rdso/pe/spec/tl/0021/2005 (rev-3) with amnt no-1.the pcb shall confirming to clause 4.4 to 4.4.8 of the rdso specification. [ warranty period: 30 months after the date of delivery ] ]
supply of set of miniature circuit breaker single pole, ac 240 /415v, 50 hz, type-c, breaking capa city 10 ka, conforming to is /iec 60898-1:2002 incorporating mounting of body as per rdso drg. no. skel 3700, alt.1 with extended terminal suitable for bg ac emu, motor load application with current r ating and quantity as follows : (1) 15/16 amps -2 nos./set, (2) 10 amps - 3 nos./set, (3) 32/35 amps - 4 nos./ set. (make: legrand/ siemens/ schneider/indo asian/ havells or their authorised dealers o nly to quote) (note: dealer should enclose latest authorised dealership certificate from oem along with offer) [ warranty period: 30 months after the date of delivery ] ]
supply of pin linkage mcb governer to drg no. goc/d/sk-4-14071 [ warranty period: 30 months after the date of delivery ] ]
supply of circuit breaker for output battery charger, battery and control circuit (pos no: 110,112,112.1) type-8, clw spec.no: clw/es/03/0050 alt.c or latest and abb document no: hbtb 585501r4371 or latest. note : 1) supply by sources as per clw ite m id: 2100412 in ireps vendor directory. 2) authorisation letter from oem specifically for this tender has to be submitted along wi th offer, otherwise offer will not be considered. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
supply of single bottle vacuum circuit breaker (vcb) of electric locos as per clw specn no. clw/ es/c-47, alt.j or latest [ warranty period: 30 months after the date of delivery ] ] amm/elsd/rpm, sr
supply of auxiliary contactor pantograph and vcb (pos no 130.1, 136.4) to clw spec no clw/es/ 3/0040 alt-c or latest, abb document no- hbtb 585683r1127 or latest. [ warranty period: 30 mont hs after the date of delivery ] ]
supply of pcb of fixed type universal bldc fan 450 mm sweep which operates under the following rati ngs. rated voltage - 110 v ac/dc, voltage range 90 v-140v, rpm-1200, min input- 40 watt, sweep- 450 m m. make: cgpisl part no.- 84024068-s or rke part no- sj-bldc-dsp-r3vi(kanwar) or spj nova part no.840 24068.spj [ warranty period: 30 months after the date of delivery ] ]
supply of switch disconnector fuse unit, capacity 63 amps, three pole with neutral link, double break, front operated handle ss sheet enclosure, as per is:60947[pt1] 2007, quick make and break, interlock at cover, uninterrupted duty as per utilization cat egory ac-23a and confirming to is: 60947[pt.3] / 1999. it shall be supplied with three numbers of bs type hrc fuses having rupt uring capacity not less than 80ka, confirming to is:13703/1993, suitable for operating on 415v, 3 phases, 50 hz ac. the supplier should submit the test report along with the material. the unit shall be similar to the c&s model e-cssdf63b3-nf. preferred make: c&s / l&t / siemens / ge / havells / schneider / indoasian. [ warranty period: 12 months after the date of delivery ] ]
supply of mccb 250a 3 pole -3vl3725 2dc36 0aa0 medha part no. sp696201004 or siemens part no. 3vl3725 1dc36 0aa 0. test certificate (tc) & guarantee certificate (gc) is also required from supplier. make: siemens /medha/ equivalent. [ warra nty period: 30 months after the date of delivery ] ]
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 475
supply of - residual current operated circuit breakers (rcbo) with integral overcurrent protection isi marked to is 12640 (part 2) (q2) - | quantity - 230
supply of floor mounted type 3 phase 12 way vertical fabricated, mccb distribution board, made out of powder coat finished 1.6mm crca sheet steel having short time withstand current 50 ka per second and co mplete with copper bus bar for there phase and neutral with suitable earth link, cable chamber for both side (rh & lh), 3 phase led indication lamp and multi function meter with ct & internal control wiring with 1 no. of 400 a, 50 ka, fp, mccb with on and off rotary handle attachment as incomer and 12 nos. of 100a, fp, 2 5ka, mccbs with on and off rotary handle attachment as complete set, mccbs conforming to is/iec 60947 or latest, mccb make: indoasian, schneider, legrand, abb, l&t, havells, anchor. c&s, bch preferable. warr anty period: 30 months. [ warranty period: 30 months after the date of delivery ] ]
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 200
supply of - residual current operated circuit breakers (rccb) without integral overcurrent protection isi marked to is 12640 (part 1) (q2) - | quantity - 250
supply of set of items for pcb components overhauling in vcu, bur and sr. one set consists of 30 items as p er annexure attached [ warranty period: 30 months after the date of delivery ] ]
supply of 750v, 3 phase, 1kv, 630a, control voltage 440v ac +10/-20% with auxiliary 4 no+ 4nc isola tion contactor (power contactor) in hog modified power cars for isolation of iv coupler input and air circuit breaker output (hog-a & hog-b) in lhb power cars as per rdso modification sheet no. rdso/pe/ms/ac/00 51-2011(rev- 2) amendment 1 & edml-154. the contactor make shall be of abb model no af750-30-22 or schneider model no lc1 -f630 or equivalent part of tele mechanique franc only [ warranty period: 30 m onths after the date of delivery ] ] sse/e/tl/ten, sr
supply of - miniature circuit breakers (mcb) for ac operation marked to isiec 60898 (part 1) (q2) - | quantity - 525
supply of supply of residual current circuit breaker with overload (rcbo) 16a, 4 pole with type 'd' tripping cu rves. 415v,50hz,sensibility 30ma ac. breaking capacity 10 ka, suitable to fit with din rail clamps. * impulse curre nt withstand at 8/20 micro seconds pulses = 3ka, make : legrand or schneider or abb or lk or siemens only. similar to cat no. auf3d401603,part no.a9n4p16d, a9v61440. [ warranty period: 24 months after the date of d elivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 la cs ] ] - supply of residual current circuit breaker
supply of - residual current operated circuit breakers (rcbo) with integral overcurrent protection isi marked to is 12640 (part 2) (q2) - | quantity - 180