Find the latest mcb tenders in western railway for 2026 from government departments, corporations and state PSUs. Get tender details and bidding information.
FILTERS
supply of contactor with surge suppressor for 60kva transformer, rated current: 95a, rated volt age: 690v ac, 50/60hz, main pole: 04 nos., aux. contact: 2no + 1nc, control circuit voltage: 230v a c +/-30% (168-300v ac) with plate & rail mounting support confirming to standard iec/en 60947. pla ce of installation: s1k44 in switch board cabinet of lhb ac coach as per rdso spec. no. rdso/pe/spe c/ac/0184-2015 (rev.1) or lat. and rdso ltr. no. el/7.1.108/mssbc dt.: 17-09-21. make as per bom are abb cat. no.af 116b-40, schneider cat. no. lc1d1150046m5+la4da2u only. note: oem or their authorized dealers are eligible to quote. in the case of authorized dealers, a valid and tender-specific authorization certificate from the original manufacturer shall be uploaded along with the offer, otherwi se the offer may be liable to be ignored. specn: rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev.1) or lat. and rdso ltr. no. el/7.1.108/mssbc dt.: 17-09-21. [ warranty period: 30 months after the da te of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs ] ]
View Insights
supply of circuit breaker 10a, 3pole, type-18 with auxiliary contact 2no for 3 phase locos as per clw spec. no. clw/es/3/0096, alt-h and abb document no.hbtb585552r3013. [ warranty p eriod: 30 months after the date of delivery ] ]
supply of mpcb for ventilation fan unit 1 & 2, thermal release range (rated current): 2.5-4.0 a, class 10, breaking capacity: 50 ka, 3 pole, rated voltage 415 v ac, with 1 no + 1 nc auxiliary contact block as per rdso common bill of material letter no: el/7.108/ mssbc dated 17.09.21. accepted make- abb catalo gue no ms:116-4 / legrand / eaton / schneider catalogue no gv2me08+gvae11/l&t catalogue no: st418 960000/ siemens catalogue no: 3rv2011-1ea10+3rv2901-1?. [ warranty period: 30 months after the d ate of delivery ] ]
supply of hrc fuse base 160 amps, 690 v ac, size nh00, as per rdso letter el/7.1.108/mssbc dt. 17/09/2021, make:- wohner-03760, siemens-3nh3 030-0rc or equivalent to abb, eaton, bussmann, l&t only (specification attached) [ warranty period: 30 months after the date of delivery ] ]
supply of vacuum circuit breaker (single bottle) for wag-7/ wap-4 conventional electric locomotives a s per clw specn. no. clw/es/c-47 alt. j & a per rdso draft modification sheet no. rdso/2026/el/ms/051 7, rev. 0 dt. 20.08.26. (note: female coupler pin should have conductor dia. 2.5 sq.mm) [ warranty perio d: 30 months after the date of delivery ] ]
supply of hrc fuse link, capacity 40 amps, rated voltage 415/550v ac, 50 hz, offset tag, b olted edge type, breaking capacity 80 ka, at 415/500v ac, 50 hz, conforming to is 13703 & iec- 60269 and icf drawing no. gs6 7-2-602, alteration-l, similar to siemens make type 3nw tss40 of iec size-a3. accepted makes: siemens, bussmann, c&s, l&t, or any other icf approved make [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] carriage stores depot ajmer,
supply of contactor for local main supply 1 & 2 (place of installation- s1k41, s1k42, s1k43), rated c urrent- 95a (at rated voltage and ac-3 utilization category), rated voltage 690v ac, main pole-4 pole, a uxiliary contacts 2no+1nc, control voltage 230v +/-15% ac, along with surge suppressor, conforming t o rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1), suitable for use in switch board cabinet o f lhb-type ac coaches. accepted make & cat/model no.: rdso-approved make and model as per serial n o. 33 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021 (excluding l&t and siemens makes), c & s with part no. lc1fdp1154u5 + la9f980 (br) or any other rdso-approved make. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] carriage stores depot ajmer,
supply of mpcb for exhaust fan 1,2 and 3 wc mbs 25 auxiliary contact (1no+1nc) and terminal block, rated current: 0.63 amp, thermal release range: 0.4- 0.63 a, rated voltage: 4 15 v ac, class-10, breaking capacity: 50 ka, pole-3p, cat no. ms116-0.63, hk1-11 of abb or gv2-m e04+gv-ae11 of schneider or 3rv2011-0ga10 +3rv2901-1e of siemens or st41892oooo+st41945 oooo of l&t make. make- as per bom of lhb switch board cabinet specification no. rdso/pe/spec/ac/01 92-2018 (rev-1) abb, schneider, siemens & l&t only. [ warranty period: 30 months after the date of d elivery ] ]
supply of set of hrc fuses as per annexure attached conforming to is -13703 (1993) and to clw specn. clw/es/f-8/e . [ warranty period: 30 months after the date of delivery ] ]
supply of miniature circuit breaker single pole 110 v dc, 35 ampss,conforming to rdso spe cn no.spec/e-12/ 1/04 of march 1992, with amendment 1 of june 1993 & to rdso drg.no.skel 370 0 alt-1 dt.05.09.1994. suitable for icf built mainline emu.make:m/s.legrand,,m/s siemens, m/s sc henider, m/s indo asian and m/s havell's. [ warranty period: 30 months after the date of delivery ] ]
supply of non deteriorating non indicating type, low voltage electrical fuse for railway signalling r ated 16 amp rated voltage 240v ac/dc fuse cylindrical cap type bhf 14x51 confirming to rdso speci fication no.- irs:s-78/92 [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs ] ] division stores depot
supply of contactor for 60kva transformer, rated voltage - 690 v ac, main pole - 4, aux. c ontact - 1no + 1nc, control voltage - 230v ac (168 v ac - 300v ac means 230v ac+/-30%) with s urge suppressor conf. to rdso spec no.rdso/pe/spec/ac/0184 - 2015 (rev-1) suitable for switc h board cabinet of lhb ac coaches. accepted make: schneider lc1d1150046ms+la4da2u, abb p art no - af116b-40 only. [ warranty period: 30 months after the date of delivery ] ] sr. section engineer(train
supply of mpcb for condenser fan unit, thermal release range (rated current) 1.6 a - 2.5 a, class 10, breaking cap- 50 ka, 3 pole, rated voltage 415 v ac, as per abb ms116-2.5, schneide r- gv2me07, l&t st41895oooo, eaton- pkzm01-1.6+nhi-e-11-pkz0, siemens 3rv2011-1ca10+3rv290 1-1e as per rdso letter no: el/7.1.108/mssbc dated 17.09.2021. suitable for use in switch board cabinet of lhb type ac coaches. make: abb, schneider, l&t, eaton, siemens only. [ warranty pe riod: 30 months after the date of delivery ] ] sr. section engineer(train
supply of switch disconnecting fuse (sdf), 2 pole 315 a, 415 v insulation suitable for 690 v with 315 a , 415 v, braking capacity of rated fuse ? 100 ka (min) and metallic cover of approx. maximum size l=450 mm, w=350mm & h=300mm with 02 nos of fuse (315 a,415 v)as per rdso modification sheet no. rdso/p e/ms/ac0086-2022 (rev.0), makes as per modification sheet, l&t cat no. ck910070009 (switch disconnect or fuse with enclosure) & sf94234 (fuse), siemens cat no. 3kx8345-4ac (enclosure), 3kl8331-2uaoo (sw itch disconnector fuse), 3na33520rc (fuse) and similar model no. abb & schneider only. [ warranty peri od: 30 months after the date of delivery ] ] sr. section engineer(train
supply of - residual current operated circuit breakers (rcbo) with integral overcurrent protection isi marked to is 12640 (part 2) (q2) - | quantity - 65
supply of miniature circuit breaker single pole 250/440 v ac 2.5 amps type 'c' with extended terminals and base.conforming to is /iec-60898-1 (2002) make : m/s legrand, m/s sie mens, m/s schenider, m/s indo asian m/s havells. [ warranty period: 30 months after the date of de livery ] ] dy cmm - dahod, wr
supply of hrc fuse cylindrical type (cartridge fuse) 2 amps, size: 10x38 mm , voltage 500v a c, breaking capacity 120 ka, confirming to rdso/pe/spec/d/0184-2015 (rev-2) or latest. suitable f or switch board cabinet of lhb coach. make: eaton, siba, bussmann, efen, ferraz, eti, l&t, sie mens & abb only. firm should submit certificate of authorization from oem & test report. ] section engineer electrical
supply of motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 o f schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no. clw/es/3/0096 alt. l or latest, str no. clw/2021/eldo/e/str/0104 rev.0.note : this item is reserved for clw approved suppli ers only. firm should submit authorized dealership certificate along with tender. [ warranty period: 30 m onths after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
supply of residual current circuit breaker with overload (rcbo) 16a, 4 pole with type 'd' tripping curv es. 415v,50hz, sensibility 30ma ac. breaking capacity 6-10 ka, suitable to fit with din rail clamps. impuls e current withstands at 8/20 microseconds pulses = 3ka, make: legrand (or) schneider (or) abb (or) lk (o r) siemens only. similar to cat no. auf3d401603, part no : a9n4p16d, a9v61440. the material shall be procured from the said oem or their authorized dealers with tender specific authorization only. [ warranty period: 30 months after the date of delivery ] ]
supply of miniature circuit breaker single pole 250/440 v ac,35a, type c with extended ter minal and base confirming to is/ies-60898-1 (2002). make: m/s.legrand,,m/s siemens, m/s schenider, m/s indo asian and m/s havell's. [ warranty period: 30 months after the date of delivery ] ] dy cmm - dahod, wr