FILTERS
supply of aoh replacement kit for single bottle vcb type 22cb to m/s schneider electric as per new part code mfr 38245 without repair kit for pressure regulator as per attached annexure b [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] diesel stores depot bgkt, - aoh replacement kit for single bottle vcb
View Insights
supply of miniature circuit braker 06 amphere 3 pole 10 ka as per legrand model no. c6 curve 415v dx. [ warranty period: 30 months after the date o f delivery ] ] - miniature circuit braker 06 amphere 3
supply of miniature circuit breaker single pole 250/440 v ac,35a, type c with extended terminal and base confirming to is/ies-60898-1 (2002). make: m/s.legrand,,m/s siemens, m/s schenider, m/s indo asian and m/s havell's. [ warranty period: 30 months after the date of deli very ] ] - miniature circuit breaker single
supply of 110 v dc,15 amps,single pole miniature circuit breaker,conforming to rdso speci fication no specn.e12/1/04 of march 1992 with ammendment 1 of june 1993 and rdso drg no. s kel 3700 alt.1 dated 05.09.1994 suitable for icf built mainline emu. [ warranty period: 30 mont hs after the date of delivery ] ] dy cmm - dahod, wr - 110 v dc,15 amps,single pole
supply of supply for main mother board pcb for cls panel of capacity 05 kva/10kva/25kva,03 nos incoming supply source of 220 volt ac with voltage verification 165 volt to 270 volt ac +/-5% and ther mal buzzer out put and buzzer remote as per spec [ warranty period: 30 months after the date of deliver y ] ] - supply for main mother board pcb
supply of set of hrc fuses as per annexure [ warranty period: 30 months after the date of delivery ] ] - set of hrc fuses as per annexure
supply of - glass fuse (q3) - | quantity - 34320
supply of 25kv drop out fuse switch assembly without insulator suitable for 25 kva auxiliary transform er as per rdso specification no. eti/psi/14 (1/86) rev i(apr-87) or latest and as per rdso drawing no. eti/ psi/032 mod d or latest and eti/psi/038 mod c or latest. [ warranty period: 30 months after the date of d elivery ] ] - 25kv drop out fuse switch
supply of circuit breaker- 2 pole, 65 amp., 74 vdc for controlling of computer in siemens controlle d hhp locomotives to siemens pt. no. 102327844, or eaton pt. no.- am2r-b-2b3-la-07-d-nu44-65-2 or ai rpax pt. no. ialhk11-71211-6. [ warranty period: 30 months after the date of delivery ] ] - circuit breaker- 2 pole, 65 amp., 74 vdc for controlling of computer in siemens controlled hhp locomotives to siemens pt. no. 102327844, or eaton pt. no.- am2r- b-2b3-la-07-d-nu44-65-2 or airpax pt. no. ialhk11-71211-6.
supply of mpcb for water pump 1 & 2 with auxiliary contact (1no+1nc) and terminal block db, rated current:1- 1.6 amp, thermal relea se range: 1-1.6a, rated voltage: 690 v, class-10, breaking capacity 50 ka, pole-3p, cat no. ms116-1.6, hk1-11 of abb or gv2-me06+gvae11 of schneider or 3rv20111aa10 +3rv2901-1e of siemens or st41894oooo+st41945oooo of l&t make. make- as per modification sheet no. rdso/pe/m s/tl/0090-2023 (rev-0) of lhb non ac coach. abb, schneider, siemens & l&t only. [ warranty period: 30 months after the date of delivery ] ] - mpcb for water pump
supply of hrc fuse link 80 amp 660v ac, 80 ka breaking capacity size 1 with indicator(both s ides mounting hole size m-12) conf to is 13703 [ warranty period: 30 months after the date of deliv ery ] ] - hrc fuse link 80 amp 660v ac, 80 ka breaking capacity size 1 with indicator(both sides mounting hole size m-12) conf to is 13703
supply of fast acting glass fuse 6.3 amps, size 6x32 mm, suitable for lhb ac coaches, make : eaton bussman part no agc-6-r of equivelent of legrand , siemens, schneider, ge, l&t, ferraz, wago, rs, wickmann, weidmuller, phoenix only. [ warranty period: 30 months after the date of delivery ] ] - fast acting glass fuse 6.3 amps, size 6x32 mm
supply of mcb 2 pole current rating 10a, voltage rating 250v dc, c curve, as per spec. no. clw/es/3/ 0037 alt-h or latest for hog control circuit modification as per rdso ms no. rdso/2026/el/ms/488 (rev 1) [ warranty period: 30 months after the date of delivery ] ] - mcb 2 pole current rating 10a, voltage rating 250v dc, c curve, as per spec. no. clw/es/3/0037 alt-h or latest for hog control circuit modification as per rdso ms no. rdso/2026/el/ms/488 (rev 1)
supply of ac circuit breaker main compressor 41a, type-16 as per clw specn. no. clw/es/3/0096 alt- l or latest with aux. contacts 2no. type: s803x-40- ah1669 qm3 41a / qx3 40a ah6569 or ng125h - d 40 a [ warranty period: 30 months after the date of delivery ] ] - ac circuit breaker main compressor 41a, type-16 as per clw specn. no. clw/es/3/0096 alt-l or latest with aux. contacts 2no. type: s803x-40- ah1669 qm3 41a / qx3 40a ah6569 or ng125h - d 40 a
supply of circuit breaker 2 pole, 10 amp. 74 vdc with trip coil for ag field to medha code - sp696131 010 or airpax part no.: ialhk21-1rec5r-39404-10. [ warranty period: 30 months after the date of delive ry ] ] - circuit breaker 2 pole, 10 amp. 74 vdc with trip coil for ag field to medha code - sp696131010 or airpax part no.: ialhk21-1rec5r-39404-10.
supply of mcb double pole, 10 amps, c curve, 200v dc as per rdso modification sheet no. rdso/2026/el/ms/488 (rev.1). makeschneider electric, abb, legrand or equivalent. [ warranty period: 30 months after the date of delivery ] ] - mcb double pole, 10 amps, c curve, 200v
supply of populated main pcb for suntron ecu (timer card/control card) for cls panel (auto changeov er panel for 30a and 60a) part number- ecu/0003. accepted offer: make/brand - suntron systems (oem). [ warranty period: 30 months after the date of delivery ] ] - populated main pcb