supply, installation, testing & commissioning of video based analytical system for detection of smoke flame , fire detection system, emergency lighting system along with related hardware equipments - supply & installation of addressable alarm control panel. controller shall be 960 character/8 inch color touch screen display, inbuilt networking port (both rs 485 & ethernet), serial port for printer with 6000 history event. the panel shall be modular, decentralized, with capability of redundancy
n cpu and power supply with full functionality, supply & installation of infrared illuminatrors with sensor which automatically switches infrared led off/on during day and night, supply & installation active repeater panel. controller shall be 960 character/ 8 inch color touch screen display, inbuilt networking port(both rs485ðernet), supply & installation of addressable control relay module with inbuilt isolators as per nfpa 72 style 7 wiring requirements & with flexible network structures, supply & installation of addressable module with one input & one output contacts, with inbuilt isolators, monitoring of a line with eol resistor, supply & installation of response indicator with matching screws complete with gi junction box, cable lugs at cable end and ferruling, supply & installation of stand alone loop powered sounder with inbuilt isolators as per nfpa 72 style 7 wiring requirements & with 20 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92 db(a), supply & installation of addressable loop powered voice sounder, this sounder shall have 28 preprogrammed signals. each signal should be sequence of a tone, a voice message, atone, a voice message. there should have minimum 4 different voice messages in 7 languages and 32 different tones available (including din tone 33404, part 3), supply & installation of video fire detection camera with inbuilt intelligent video analytics and shall detect flames and smoke within an incredibly short time span by analyzing video sequences. the video-based fire detection shall be capable of working under low-light (down to 2 lx) and detects test fires like tf1, tf2 upto tf8, supply & installation of 4 loops panel microprocessor based intelligent,digitally addressable fire alarm control panel with minimum 250 devices (250 in any combination per loop).the panel shall have minimum 7 inch screen display with soft keys for displaying alarm, events and operating functions, compatible with graphic user interface for pin point the identification of the fire location ,suitable to operate on 240 volts ac power supply. the panel shall be equipped with automatic battery charger , 24 volts maintenance free batteries sufficient for 24 hours working in normal condition & and then be capable of operating the system for minimum 30 minutes during an emergency conditions as required, supply & installation of ul / en listed intelligent photoelectric multisensor detector with inbuilt fault ioslator / isolator base,alarm indication led, with electronic addressing feature to programme the detectors. the addressable smoke detector shall have ip rating of upto ip30 and operating temperature -10 c to 60 c complete, supply & installation ofen / ul listed 2 input / output module with inbuilt fault isolator / isolator module with minimum ip50, shall be capable of providing dpdt contact rated at 24v dc, 2a.operating temperature shall be -10 c to 60 c (for monitoring different electrical/mechanical device like flow switch etc.), supply & installation of 1 addressable alarm control panel with an 8-inch colour touch screen and cpu/power redundancy, 10 infrared illuminators with automated day/night sensors, 1 active repeater panel matching the main controller interface, 12 addressable control relay modules featuring inbuilt isolators, 12 addressable modules equipped with 1-input/1-output contacts and end-of-line line monitoring, 12 response indicators complete with gi junction boxes and cable lugs, 12 loop powered sounders offering 20 tone variants and 5-level adjustable sound pressure, 12 addressable loop powered voice sounders with 28 preprogrammed multi-language signals, 12 video fire detection (vfd) cameras with intelligent video analytics for rapid flame and smoke recognition down to 2 lx low-light conditions, 1 microprocessor-based intelligent 4-loop fire alarm control panel supporting a minimum of 250 combination devices per loop and dynamic integration protocols like bacnet or modbus, 290 intelligent photoelectric multisensor detectors with electronic addressing and ip30-rated faults isolators for false-ceiling or concealed spaces, 30 ip50-rated 2-input / 2-output modules capable of monitoring electrical or mechanical flow switches, 7 loop powered hooter-cum-strobes with integrated fault isolators, 7 addressable resetting-type manual call points with a minimum rating of ip40, 1 graphical user interface (gui) web-server software package supporting autocad 3d layout imports and secure network encryptions, 1 client workstation configured with an intel core i7 processor, 16gb ddr ram, 1tb internal storage, a 2gb nvidia graphics card, and preloaded windows 10 os, the supply and laying of 3,500 metres of 2c x 1.5 sqmm fire survival armoured cable featuring epr insulation and an lszh outer sheath, the supply and laying of 1,200 metres of cat6 armoured cable, electrification works in the gallery and rooms, 2 high-performance hd video decoders optimized for 4k uhd streaming, 10 camera licenses for smoke detection, labour charges for cable laying, programming & integration charges to sync with the pre-existing cctv surveillance framework, 1 full hd led monitor with hdmi and component inputs, 3 stackable 24-port poe+ switches, 1 addressable single/double-sided emergency led signage featuring a minimum 90-minute operational backup, 45 adaptive addressable 20/30-meter exit escape sign luminaires calibrated to dynamically switch directions or exhibit a red 'x' based on automated fire module matrices, 16 open-space emergency recessed led luminaires producing 250 lm, 25 open-space anti-panic recessed led luminaires, 25 conversion address modules to adapt standard lighting fixtures up to 80w into temporary emergency fixtures, 1 central battery system panel fortified with cybersecurity features, deep-discharge protection, and a 4.3" tft interface, 8 3-phase monitoring i/o modules configured on dedicated rs485 bus topologies to continually trace local distribution panels, 1 heavy-duty vrla battery rack assembly utilizing gas-recombination sealed lead-acid cells designed for a 10-year service life, 1 inbuilt battery monitoring system enclosed within the rack workspace, 1 battery monitoring module tracking voltage, impedance, and internal temperatures alongside a modbus-integrated gateway system, 1 web-based graphical user interface license to supervise up to 500 individual backup configurations, 1 bacnet/ip or modbus/ip interface gateway, the supply and laying of 2,000 metres of 3c x 2.5 mm2 fire survival armoured cables retaining circuit protection up to 2 hours at 950 c, a collective segment of supplementary electrification works, and the absolute testing & commissioning of the entire installed system to perfectly harmonize with the secretariat's existing delta and bosch equipment configurations.
Description :repair, maintenance, and installation of plant systemsequipments (version 2) - government office; as per attached scope of work; service provider
7
Days Left
Submission Date
25 SEP 2026
Opening Date
25 SEP 2026
Tender Estimated Cost
Refer Document
EMD
₹ 5.00 Lakh
Apply with Surety Bond
Tender Document Fees
Refer Document
AI Bid Assistant
Prepare a complete bid response for this tender in under 30 minutes.
Tender247 tries to ensure accurate & authentic tender information at its level best however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before participating / submitting bid.