supply of - 1 long guiding sheath for radial access with id point 088inches with hvdrophilic coating , 2 long guide sheath 6f point088inches for femoral use , 3 intermediate catheter 070inches for intracranial neurovascular use available in id 035inches to 070inches , 4 dmso compatible detachable tip microcatheter with distal 1point5f for avm embolization with wire also available in 1point 2f distal diameter , 5 intrasaccular aneurysm device for neurovascular use , 6 dual lumen extracompliant
lloon catheter for intracranial use 4x11 mm , 7 neurovascular detachable coils 3d with expandable coating latest generation , 8 electrolytically detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 9 electrothermally detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 10 nitinol flow diverter withdrawn filled tubing for cerebral aneurysms latest generation , 11 microcatheter 0165 for endovascular coiling of aneurysms 2point4f proximal 1point7f distal with 2 tip markers , 12 dual layer hydrophilic coated 021 inches rocutfretinches for neurovascular device delivery , 13 microcatheter 027inches for deployment of intracranial device , 14 liquid embolic agent 18psi evoh based for avm embolization available in 12 and 18 concentration 1point5 ml , 15 mechanically detachable coil for intracranial aneurysm coiling they should be latest generation of varying sizes coil detacher if required should be provided , 16 microguidewire , 17 remodelling balloon , 18 flow diverter low profile flow diverter , 19 dual compatible microcatheter for aneurysm coiling and avm embolization 156 cm and 167 cm lengths , 20 microguidewire for liquid embolics , 21cobalt chromium flow diverter , 22 stent retriever with parametric design 021inches compatible with at least 3 distal and 1 proximal radio opaque marker and multiple markers along the length of the device for better visibility , 23 aspiration catheter for mechanical thrombectomy zero point 072 inches - dsa consumable for neurointervension | quantity - 1164
Description : - 1 long guiding sheath for radial access with id point 088inches with hvdrophilic coating , 2 long guide sheath 6f point088inches for femoral use , 3 intermediate catheter 070inches for intracranial neurovascular use available in id 035inches to 070inches , 4 dmso compatible detachable tip microcatheter with distal 1point5f for avm embolization with wire also available in 1point 2f distal diameter , 5 intrasaccular aneurysm device for neurovascular use , 6 dual lumen extracompliant balloon catheter for intracranial use 4x11 mm , 7 neurovascular detachable coils 3d with expandable coating latest generation , 8 electrolytically detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 9 electrothermally detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 10 nitinol flow diverter withdrawn filled tubing for cerebral aneurysms latest generation , 11 microcatheter 0165 for endovascular coiling of aneurysms 2point4f proximal 1point7f distal with 2 tip markers , 12 dual layer hydrophilic coated 021 inches rocutfretinches for neurovascular device delivery , 13 microcatheter 027inches for deployment of intracranial device , 14 liquid embolic agent 18psi evoh based for avm embolization available in 12 and 18 concentration 1point5 ml , 15 mechanically detachable coil for intracranial aneurysm coiling they should be latest generation of varying sizes coil detacher if required should be provided , 16 microguidewire , 17 remodelling balloon , 18 flow diverter low profile flow diverter , 19 dual compatible microcatheter for aneurysm coiling and avm embolization 156 cm and 167 cm lengths , 20 microguidewire for liquid embolics , 21cobalt chromium flow diverter , 22 stent retriever with parametric design 021inches compatible with at least 3 distal and 1 proximal radio opaque marker and multiple markers along the length of the device for better visibility , 23 aspiration catheter for mechanical thrombectomy zero point 072 inches
1
Days Before
Submission Date
17 SEP 2026
Opening Date
17 SEP 2026
Tender Estimated Cost
₹ 12.77 Cr.
EMD
Refer Document
Apply with Surety Bond
Tender Document Fees
Refer Document
AI Bid Assistant
Prepare a complete bid response for this tender in under 30 minutes.
Tender247 tries to ensure accurate & authentic tender information at its level best however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before participating / submitting bid.