Submission Date
29 SEP 2026Opening Date
01 OCT 2026Tender Estimated Cost
Refer DocumentEMD
₹ 50.00 KTender Document Fees
Refer DocumentPrepare a complete bid response for this tender in under 30 minutes.
0000_xyzw_00000_0
Department Of Health Services has invited bids for the supply of cath lab equipments - "angiographic catheter comprised of a two-layer construction, double braided stainless-steel two-ply mesh, sandwiched between layers of polyurethane and polyamide elastomers., -steel, braid., r layer and outer layer contain barium sulphate., -kinking protector, with non-braided tip shaft (distal -2 cm) ., designed to cannulate left and right coronary arteries tig, tig ii,, e in 4f, 5f, 6f sizes, 1.03mm, 5f= 1.20mm, 6f = 1.30mm, -approved", "femoral diagnostic catheter:, steel mesh technology., 1.20mm, 6fr = 1.30mm or more resulting in higher flow rates., -steel, braid., should contain barium sulphate, have ultra-thin wall that creates large lumen.", "-kinking protector, with non-braided tip shaft (distal - 2 cm)., ar, im, pigtail. designed to cannulate vasculature in coronary,, approved", "multipurpose(mp)diagnostic catheter size ranging from 5f to 6f/100cm, hydrophillic guidewire with super elastic nitinol allow for superior kink resistance,, extra lubricity., construction for one to one torque & radiopaque polyurethane jacket., -infused, polyurethane jacket., - straight, and angle usfda/pmda approved", multipurpose(mp)diagnostic catheter size ranging from 5f to 6f/100cm, "introducer sheath with puncture needle for adults (sizes 5 - 11 fr.) , -16-25 cm long;, 0.021 or 0.025-inch guide wire compatible;, of etfe, cross cut valve should be made up of silicon rubber &, should have silicone coating. dilator tube should be made up of polypropylene and should have silicon, coating., valve; with integrated side arm with attached 3-way stopcock; with, suture eye for securing sheath and click sound; kink resistant., -hub lock mechanism to prevent its back-out during insertion; pack must include, with or without metallic needle, "radial introducer sheath with puncture needle for adults (sizes 4, - 7 fr.) , 0.038-inch guide wire compatible, include surflash 20g*2 entry, needle (plastic iv catheter) and 0.025 mini plastic guidewire, h tubing, dilator tube should be made up of polypropylene and should have silicon, coating;, valve to prevent back leak of blood and aspiration of air; with, integrated side arm with attached 3-way stopcock;, uture eye; kink resistant; with dilator-hub lock mechanism., ", "150cm long hydrophilic guide wire, 0.035 black angled & straight.", "260 cm long hydrophilic guidewire 0.035, black angled and straight", 150cm-260cm ptfe coated guide wire, ebu guiding catheter length for 100cm)size 5f,6f,7f curves 3,3.5,4.0,4.5,5.0), "judkins left guiding catheter 5f-, 7f/100cm,curve 3,3.5,4.0,4.5,5.0", "judkins right guiding catheter for 5f-, 7f/100cm curve 3.5 and 4.0/side holes", "amplatz,right and left(ar& al)6f-7f/100cm curves 1.0,2.0,3.0 side holes guiding, catheter", mbi and ima guiding catheter 6f-7f/100cm, pressure monitoring line-100cm-200cm., "puncture needle 18g &20g 18g-7cm,20g-, 4cm", inflation device- gun type, 3 port manifold, "high pressure resistance y- connector with, bonded extension tube push pull valve", jelco 20g, surgeon gown, "angiogram kit(surgeons gown-2nos,hand towel 2nos,large drop with aperture, 1nos,trolley sheet-1nos,wrap sheet 1nos)", biohazard angiogram kit, "special slender sheath (gss), reducing the outer diameter by 1 fr size whilst maintaining the one, size lager inner diameter., diameter of 2.8mm, 6fr with od of 2.46 mm & 5fr with od of 2.13mm., coating with 20/21g surflash needle and tif tip technology which provide optimal tapering design., "femoral diagnostic catheter:, steel mesh technology., =1.03mm ,5fr =, 1.20mm, 6fr = 1.30mm or more resulting in higher flow rates., -steel, braid., catheter should have ultra-thin wall that creates large lumen., -kinking protector, with non-braided tip shaft (distal - 2 cm)., ar, im, pigtail. designed to cannulate vasculature in coronary,, "hydrophillic guidewire with super elastic nitinol allow for superior kink resistance,, extra lubricity., torque & radiopaque polyurethane jacket., -infused, polyurethane jacket., ble in 150 cm, 180 cm -, straight and angle", "hydrophillic guidewire with super elastic nitinol allow for superior kink resistance,, extra lubricity., one piece construction for one to one torque & radiopaque polyurethane jacket., -infused, polyurethane jacket., - straight, and angle usfda/pmda approved", "baby j wire with 1.5mm j tip,, j curve must have radius of 1.5, mm., oy, m coat, hydrophilic coat,, torque & radiopaque polyurethane jacket., -infused, polyurethane jacket., "ptfe guidewire, v stick, with choice of stainless steel core or nitinol core,, 40 cms to 260 cms of lengths & 0.018'' to 0.038'', diameter, with silicon coated tip and bevel indicator usfda/pmda approved", "guiding catheter , flat 2 over 2, stainless steel wire guiding catheter with hydrophilic coating (uncoated distal 7 cm & proximal 25 cm)., fluoro polymer, hapes like tig/ebu/xbra,jr, jr with side holes., pmda approved/usfda", special guiding catheter ikari curve, "must have ikari curve for radial route. must have stainless steel flat wire braid, high strength wired braided catheter with inner layer of ptfe with fluoro polymer., must have zone technology - five zone each fabricated from a material of different stiffness., must have larger lumen. 6fr id -, .071", usfda/pmda approved", guiding catheter 6f /7f having henka braiding, atraumatic tip, flexiblity and more radiopacity, 100cm, ptfe inner liner, urethane tip for flexiblity and visualisation. jl / jr/extra backup/special curve/ar/al/mp, "balloon inflation device ii, 30 ml clear syringe barrel with smooth moving plunger. adjustable manometer 45degree left and right. nighlight dial", radial artery compression tourniquets transparent pad. spherical design. elastic pressure belt. contactless supporting pad, "y connector(push click), unique push click design . torque & introducer fit0.014""-0.021"" guidewire. 180 psi leak-proofseal from propreitary valve", "guide wire m stiff type is a nitinol hydrophilic guide wire covered, with polyurethane containing tungsten and a hydrophilic polymer, coating (patented m coating) with good shape memory and high, stiffness and resistance and comes in 150 cms length.", "guide wire m stiff type is a nitinol hydrophilic guide, wire covered", "with polyurethane containing tungsten and a hydrophilic polymer, coating (patented m coating) with good shape memory and high, stiffness and resistance and comes in 260 cms length.", "femoral introducer sheath, introducer sheath with puncture needle for adults, (sizes 5 - 11 fr.) , standard length; 10-16-25 cm long; 0.021 or 0.025-inch guide wire, compatible; material of sheath tubing should be made of etfe,, cross cut valve should be made up of silicon rubber & should have, silicone coating. dilator tube should be made up of polypropylene, and should have silicon coating. must have with haemostatic, crosscut valve; with integrated side arm with attached 3-way, stopcock; with suture eye for securing sheath and click sound;, kink resistant. must have with dilator-hub lock mechanism to, prevent its back-out during insertion; pack must include with or, without metallic needle usfda/pmda approved", "finecross m3, coronary micro-guide catheter distal diameter 1.8 fr coronary, micro-guide catheter tapered stainless steel braid mesh, construction and inner ptfe layer. 13 cm floppy distal segment., distal outer diameter 1.8 fr and proximal outer diameter 2.6fr., 70cm distal hydrophilic coating. length 130cm for antegrade approach and 150 cm for retrograde approach. gold, marker for the tip visibility", "guidewire material: nitinol: proximal & stainless steel(304 v) / tip material: platinum- tungsten coil, alloy & hydrophilic polymer coating/coating: hydrophilic coating / ptfe coating on proximal shaft,", "distal tip is radiopaque / guidewire diameter: 0.014"", / length: 180 cm & 300 cm., flexibility / stiffness: 0.6 gf, 0.7 gf & 1.0 gf / radiopaque coil length : 3 cm.., hydrophilic coating length : 25 cm. & 28 cm./ distal core wire : 40 cm nitinol from distal tip", "y connector(push click): unique push click design . torque & introducer fit0.014""-0.021"" guidewire. 180, psi leak-proofseal from propreitary valve", "y connector(twist):memory hemostatic device . large inner diameter. 300 psi leak proof seal from, propreitary valve", "balloon inflation device:ergonomic design. selok patent technology . precise pressure gauges., maximum pressure of 30 atm. 20 ml clear syringe barrel with smooth moving plunger.", "balloon inflation device:30 ml clear syringe barrel with smooth moving plunger. adjustable manometer, 45degree left and right. nighlight dial", "inflation device(screw type): single hand deflation mechanism / high pressure upto: 40 atm/ clear, guage display", "high pressure line:pressure rating upto 500 psi., standard length at 900 mm and 1220 mm", "introducer sheath kit:smooth transition between dialator and sheath. polyer guidewire with hydrophilic coating & iv catheter. french size(5,7,8f), sheath length(8,11 cm.),guidewire size 0.025"",, needle(trocar), needle gauge(20g),", "introducer sheath: atraumatic tapered tip. hydrophilic coating. french size(5f, 6f,7f,8f).sheath length(8cm& 11 cm). guidewire size(0.021""&0.38""). needle(metal / trocar). needle gauge(21,20, g.radial)(18g..femoral)", "mini introducer kit : sheath length :(7 cm to 10 cm.)/ guidewire(nitinol/platinum(0.018""x45 cm.)/ needle(21 gx4.5cm/7cm echogenic / non echogenic needle / shaeth size(4 f / 5 f) / shaeth type: standard, / stiffen)", "proximal optimisation technique. optimised shoulder length: 0.6mm.3 t technology(transition free zone ., 0.43 mm tapered profile for lesion, 2mm tri-layered atraumatic tip). diameter: 2.5 to 5 mm & length: 6mm to 15mm. poximal shaft : 2 f . distal shaft : 2.7, f. tip length : 2 mm. crsossing profile: 0.83"". coating, : hydrophilic. nominal pressure: 12 atm . rbp: 22 atm.", high pressure balloon. higher rbp: 26 atm. lowest, "crossing profile : 0.33"". 3 t technology(transition free zone . 0.43 mm tapered profile for lesion, 2mm tri-layered atraumatic tip). diameter: 2mm to 5mm & length 6 to 15 mm. proximal shaft : 2.1 f. distal shaft :, 2.7f(2mm to 5mm). tip length: 2mm(2mm to 5 mm). marker band:2. crossing profile : 0.33"". coating : profile. nominal pressure:14mm. rbp: 24mm & 26, atm. balloon material : nylon 12. balloon fold : 3", "scoring balloon catheter:catheter type: rapid exchange / guidewire lumen diameter:0.014""/material: nylon blend/balloon compiance: non compliant /crossing profile:0.0313""/.0.79 mm/ coating(distal shaft and tip): hydro x hydrophilic coating / coating (guidewire lumen): invio hydrophobic / nbp: 12 atm / rbp: 20 atm/available diameter (in mm):1.75, 2, 2.25,, 2.5,2.75, 3, 3.5, 4 / available length (in mm):10, 15, 20 / ce approved", "microsurgical cutting balloon.hydro c coating. non complaint. based on microsurgical atherotome concept.low profile blade height(0.13 mm). pre-shaped longitudinal segmentation. tip entry profile: 0.016""high contrast 1mm width for naccurate visualization under fluoroscopy.distal shaft:2.36-, 2.6f.proximal shaft: 2 f", "scoring dilation catheter: balloon material: semi compliant / scoring element material : nylon / number of scoring element: 3 / proximal shaft : 2f/ distal shaft: 2.6f / np: 6 atm / rbp: 14 atm / diameter: 2-4.5 mm / balloon length: 8/12/15/20, mm / gw compatibility: 0.017""", "contrast media- lohexol,100ml (300-350mg, lodine/ml)", "blunt introducer, 20 g facilitate guidewire entry smoothly. fits guidewire sizes up to 0.020 inches.", "torque device ( torque device options: blue , white and orange ), easy to grip torquer which provides 1:1 torquer control and easy movement of the guidewire. (gw capacity 0.014"")", torque glider (torque glider color options : yellow and red ), screw type hemostasis y-connector & kit, push pull hemostasis y-connector & kit push click hemostasis y-connector & kit, "introducer needle, 18 g x 7cm, 20 g x 4 cm, 21 g x 4 cm, 20 g x 32 mm(catheter) iv needle and 20 g x 45 mm(catheter) iv needle, needle material - stainless steel aisi 304 made from japanese tube which is electro polished inside and outside and hydrophilic coated", "2 & 3 port stopcock manifold, 2 port manifold right (off) 250 psi, 2 port manifold right (on) 250 psi, 3 port manifold right (off) 250 psi 3 port manifold right (on) 250 psi 2 port manifold right (off) 500 psi, 2 port manifold right (on) 500 psi, 3 port manifold right (off) 500 psi 3 port manifold right (on) 500 psi, clear handle sign indicates fluid control, anti-siphon, flexible luer provides better sealing performance under 500 psi pressure, unique female ports suitable for various connectors.", "control device, 2,3,5,10,12,20 ml barrel syringe. easy to move plunger in cylinder and generate high pressure resistance.", "pressure monitor line, designed to sustain pressure in the range of 450-1200 psi. made from non toxic medical grade pvc and tpu reinforced with nylon fiber., length: 25 cm x pressure: 450 psi, length: 25 cm x pressure: 250 psi, length: 25 cm x pressure: 1200 psi, length: 50 cm x pressure: 450 psi, length: 50 cm x pressure: 250 psi, length: 50 cm x pressure: 1200 psi, length: 100 cm x pressure: 450 psi, length: 100 cm x pressure: 250 psi, length: 75 cm x pressure: 1200 psi, length: 120 cm x pressure: 450 psi, length: 120 cm x pressure: 250 psi, length: 100 cm x pressure: 1200 psi, length: 150 cm x pressure: 450 psi, length: 150 cm x pressure: 250 psi, length: 120 cm x pressure: 1200", "psi, length: 200 cm x pressure: 450 psi, length: 200 cm x pressure: 250 psi, length: 150 cm x pressure: 1200 psi, length: 250 cm x pressure: 450 psi, length: 250 cm x pressure: 250 psi,", "angoigraphy kit and angioplasty kit, 2 port right off manifol, pml - 200 cm (450 psi), iv set vented, 10 ml luer lock syringe, 5 ml luer lock syringe, introducer needle 18g - 7cm., 3 port right off manifol, pml - 200 cm (450 psi), iv set vented, 12 ml luer lock syringe, 5 ml luer lock syringe, 10 ml luer lock syringe, introducer needle 18g - 7cm, high pressure line 100 cm, ptca connector push pull kit.", inflation device - gun type inflation device - ultima type inflation device - mega type inflation device - screw type, "angiography guide wire, ptfe (pre-coated) stright and j tip - 0.025"", 0.032"", 0.035"" and 0.038"" x 150 cm, 180 cm, 260 cm nitinol stright and j tip - 0.025"", 0.032"", 0.035"" and 0.038"" x 150 cm, 180 cm, 260 cm, ptfe coating throughout the whole shaft, straight and j tip (available in pre- coated and poast - coated)., made from ss 304 core and nitinol alloy, special core wire design increases crossability in tortuous vessels.", "hydrophilic wire, hydrophilic coating throughout the whole shaft,made from ss 304 core and nitinol alloy. angel tip - 0.032"", 0.035"" and 0.038"" x 150 cm, 260, cm, straight tip - 0.032"", 0.035"" and 0.038"" x 150 cm and, 0.025"" x 45 cm", "introducer radial sheath, radio oaque sheath with proprietary homeostasis valve and side apart with attached 3-way stopcock side arm, radio opaque atraumatic vessel dilator,, smooth atraumatic arterial sheath & dilator", "transitions locking hub design, dilator internal tip diameter equals to mini guidewire external diamter. 4f radial x 9 cm, 5f radial x 7, 9, 11 cm, 6f radial x 7, 9, 11 cm 7f radial x 11 cm", "introducer radial sheath kit, radio oaque sheath with proprietary homeostasis valve and side apart with attached 3-way stopcock side arm, radio opaque atraumatic vessel dilator, smooth atraumatic arterial sheath & dilator transitions locking hub design, dilator internal tip diameter equals to mini guidewire external diamter. 4f radial x 9 cm + 0.021""x 45cm guide wire , 20g x 4 cm introducer needle, 5f radial x 9, 11 cm + 0.021""x 45cm guide wire , 20g x 4 cm introducer needle, 6f radial x 9, 11 cm + 0.021""x 45cm guide wire , 20g x 4 cm introducer needle, 7f radial x 11 cm + 0.021""x 45cm guide wire , 20g x 4 cm introducer needle, 5f radial x 7 cm + 0.025""x 45cm guide wire , 20g x 32/45 mm introducer needle, 6f radial x 7 cm + 0.025""x 45cm guide wire , 20g x 32/45 mm introducer needle", "introducer femoral sheath, radio oaque sheath with proprietary homeostasis valve and side apart with attached 3-way stopcock side arm, radio opaque atraumatic vessel dilator, smooth atraumatic arterial sheath & dilator transitions locking hub design, dilator internal tip diameter equals to mini guidewire external diamter. 4f femoral x 10 cm + 0.035"" x 45 cm guide wire, 18g x 7cm introducer needle, 5f, 6f, 7f, 8f femoral x 11 cm + 0.038"" x 45 cm guide wire, 18g x 7cm introducer needle", "introducer femoral sheath kit, radio oaque sheath with proprietary homeostasis valve and side apart with attached 3-way stopcock side arm, radio opaque atraumatic vessel dilator, smooth atraumatic arterial sheath & dilator transitions locking hub design, dilator internal tip diameter equals to mini guidewire external diamter. 4f femoral x 10 cm, 5f, 6f, 7f, 8f femoral x 11 cm", "guiding catheter, 100 cm catheter length for easy navigation to the target vessel via radial artry. winged polycarbonate hub design for easy manipulation wire braided for torque, stability and control. ptfe inner layer allows smooth guide wire handling with less resistance, even in totuous anatomy., 6f - ebu3.0, ebu3.5, al1, al2, ar1, ar2, jl3.0, jl3.5, jr3.0, jr3.5 x 100 cm, 5f - jl3.0, jl3.5, jr3.0, jr3.5 x 100 cm", "angiography catheter tig-2 (5f, tig2, 100 cm), 100 cm catheter length for easy navigation to the target vessel via radial artry.winged polycarbonate hub design for easy manipulation, wire braided for torque, stability and control.larger inner lumens to facilitate contrast injection , soft tip provides atraumatic positioning within the vessel ostium., angiography catheter, 100 cm catheter length for easy navigation to the target vessel via radial artry.winged polycarbonate hub design for easy manipulation wire braided for torque, stability and control.larger inner lumens to facilitate contrast injection , soft tip provides atraumatic positioning within the vessel ostium., 5f - jl3.0,jl3.5,jr3.0, jr3.5 x 100 cm, 6f - jl3.0,jl3.5,jr3.0, jr3.5, al1, al2 x 100 cm", "mutiway (2-3 port manifold) right on/off with/without color code . continues large internal lumen for high flow rates. smooth turning handles. lates free.products are available sterile and non, sterile.", "y connector with dual valve one with push and other with screw type with ability to lock push and pull mechanism. with upto 10 fr compatibility and above, 3.25mm inner diameter and 90 mm length. prevent back blood flow in closed position and minimal in half open position.", y connector(push click), "unique push click design . torque & introducer fit0.014""-0.021"" guidewire. 180 psi leak-proofseal, from propreitary valve", y connector(twist), "memory hemostatic device . large inner diameter., 300 psi leak proof seal from propreitary valve", balloon inflation device, "ergonomic design. selok patent technology . precise pressure gauges. maximum pressure of 30 atm. 20, ml clear syringe barrel with smooth moving plunger.", balloon inflation device ii, "30 ml clear syringe barrel with smooth moving plunger. adjustable manometer 45degree left and, right. nighlight dial", radial artery compression tourniquets, "transparent pad. spherical design. elastic pressure, belt. contactless supporting pad", control syringe, "glass like polycarbonate barrel with enhanced scale marking. designed for single hand operation. plunger, with latex- free stop", high pressure line, pressure rating upto 500 psi. standard length at 900 mm and 1220 mm, introducer sheath, "atraumatic tapered tip. hydrophilic coating. french size(5f, 6f,7f,8f).sheath length(8cm& 11 cm)., guidewire size(0.021""&0.38""). needle(metal / trocar). needle gauge(21,20 g.radial)(18g..femoral)", introducer sheath kit, "smooth transition between dialator and sheath. polyer guidewire with hydrophilic coating & iv catheter. french size(5,7,8f), sheath length(8,11 cm.),guidewire size 0.025"", needle(trocar), needle, gauge(20g),", iv catheter 20g x 32 /45 mm, y connector, angiographic syringe pump(190ml), disposable mri injectable syringe 65ml(for contrast & 115ml saline with connector tube., with an EMD of ₹0.01 Cr. Please refer to the tender document for project value details. Interested bidders can submit applications until 29 September 2026, with the technical opening scheduled for 1 October 2026.
Loading.....
The EMD is ₹50 Thousand.
Bids close on 29 September 2026; bid opening is on 1 October 2026.
Department Of Health Services, Kerala.