erolimus(1.1 microgram/mm2) eluting ,strut thickness, 55 microns ,cobalt chromium platform,biodegradable polymer matrix", semi compliant ptca balloon catheter,ce approved,tip entry profile 0.016" ,distal shaft 2.6f with platinium iridium marker bands,nominal pressure of 6 atm balloon size 1.2 -4.5 mm and length 7 to 45mm, "non compliant ptca balloon catheter ,ce approved,tip entry profile of 0.016"",distal shaft 2.6 f with platinum iridium marker bands, ,nominal pressure of 14 atm,balloon size 1.2 to 4 mm and length 7mm to 45 mm", des,sirolimus eluting cobalt chromium platform,65 microns strut thickness,with a tip entry profile of 0.016" and crossing profile 0.037", des,rapamycin eluting,cobalt chromium platform,60 microns strut thickness, des ce approved sirolimus 1.3m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters,2m of plla & plga polymers and drug coating, crossing profile 0.88mm. diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des dcgi approved everolimus 1.00m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters, plla & plga polymers, crossing profile 0.88mm.diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des everolimus cobalt chromium dcga approved 60m strut thickness,3m coating thickness, wider peak design and strut locking machanism for radial strength, plga polymer with hydrophilic coated delivery system. size 2.25 to 5 diameter and length from 8mm to 48mm, guide extension catheter with hydrophilic coating, length 1500mm. outer diameter 1.35mm inner diameter-1.17mm, 2mm soft atraumatic tip with 3mm long entry port and stainless steel collar, semi compliant balloon dcgi approved, entry tip profile 0.016,diameter 1,1.10,1.25,1.5 to 4 mm and length 5,8 to 40mm with nominal 6atm and rbp 14atm. catheter length 141cm. crossing profile 0.022 - 0.039., non compliant balloon dcgi approved, entry tip profile 0.016,diameter 2,2.25,2.5,2.75 to 5 mm and length 8 to 40mm with nominal 12atm, rbp 22atm,mbp>=30 . catheter length 141cm. crossing profile 0.029 - 0.0530., transcatheter bicaval try tissue valves system for tricuspid regurgitation, tavr - aortic self expandable transcatheter dry tissue technology valve, 180 cm length, 1.0 tip load cto wire for ptca (tip shape straight), durable patented hydrphilic m coating, with innovative duo core, for a great torque response hybrid wire that fuses nitinol & stainless steel, 180cm and 300 cm., "dcgi approved biodegradable polymer based everolimus eluting coronary stent system with differencial stent architecture of 6 crown design for 2 -, 2.75 mm , 8 crown for 3-3.5 & 10 crown design for 4-4.5 mm length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5", "ce approved biodegradable polymer based sirolimus eluting coronary stent system with differencial stent architecture of 6 crown design for 2 - 2.75 mm , 8 crown for 3- 3.5 & 10 crown design for 4-4.5 mm, length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5", "ce/dcgi approved rapamycin target eluting coronary stent system with cobalt chromium platform and abluminal in-groove design and bioabsorbable polymer. length- 13 mm,16,18,21,23,26,29,31,33,35 and 38mm. diametre-, 2.25 mm,2.5,2.75,3,3.5 and 4 mm.", "ce approved non complaint balloon catheter, balloon size : 2.25mm - 5mm/length : 6mm-20mm rapid exchange proximal shaft, 2.3 f and distal shaft - 2.7 f,tip entry profile 0.017 with nominal inflation pressure 12 atm & rbp-20 atm,and having two plantium iridum markers.", ce approved semi complaint balloon catheter, inner shaft with patented 2 layer design using specialized material. balloon size : 1.00 mm - 4.00mm/length : 6mm-20mm rapid exchange,proximal shaft-2.2 f and distal shaft-2.1 f,crossing profile 0.021" - 0.027" with nominal inflation pressure-6 atm & rbp-16 atm., "ce/dcgi approved thrombus aspiration catheter with removable core wire and 30cm hydrophilic coating from the tip; available in 6f and & 7f., length 145 cm", transcatheter aortic valve replacement system : self expandable system with bovine pericardial leaflets and hybrid cell density frame, electrically motorised recapturable tavi system, vital-x anti-calcification technology,advanced double layer pet skirt.effective length-112 cm,integrated sheath length-30 cm diameter 21mm,24mm,27mm & 30mm., icd single chamber with bluetooth technology, icd dual chamber with bluetooth technology, icd single chamber with bluetooth technology, icd dual chamber with bluetooth technology, "permanent pacemaker- single chamber ,1.5/3t full body mri compatible,bluetooth enabled,advanced physiological rate response,automatic capture, management,bluetooth based remote programming and monitoring,8cc designed with ellipsed shapes for better lead wrap and insertion,20% smaller and lighter,battery life of up to 12-13 years, 10% improvement in energy efficiency, 15% better heart rate adjustment, 8+2 years warranty,battery life diagnostics with 95% accuracy,35% fewer pocket related complications.", "permanent pacemaker- dual chamber ,1.5/3t full body mri compatible,bluetooth enabled,advanced physiological rate response,automatic capture, management,bluetooth based remote programming and monitoring,8cc designed with ellipsed shapes for better lead wrap and insertion,20% smaller and lighter,battery life of up to 12-13 years, 10% improvement in energy efficiency, 15% better heart rate adjustment, 8+2 years warranty,battery life diagnostics with 95% accuracy,35% fewer pocket related complications.", permanent pacemaker- single chamber, without bluetooth device, permanent pacemaker- dual chamber,without bluetooth device, des ce approved sirolimus 1.3m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters,2m of plla & plga polymers and drug coating, crossing profile 0.88mm. diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des dcgi approved everolimus 1.00m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters, plla & plga polymers, crossing profile 0.88mm.diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des everolimus cobalt chromium dcga approved 60m strut thickness,3m coating thickness, wider peak design and strut locking machanism for radial strength, plga polymer with hydrophilic coated delivery system. size 2.25 to 5 diameter and length from 8mm to 48mm, semi complaint cutting balloon dialation catheter,carbon alloy steel blades, blades working length-0.13mm with hydrosurf coating & 0.43mm short tip, paclitaxel coated balloon with urea excipient, trifold & dose of 3micro gm/mm, sq.diameter-2.0 to 4.5mm and length- 9 to 38 mm, semi compliant balloon ce approved, entry tip profile 0.016, hydrophilic coating with nominal 6atm and rbp 14atm, tavr - aortic self expandable transcatheter dry tissue technology valve 23,26,29,31mm. factory loaded with straight sealing zone., transcatheter bicaval dry tissue valves for tricuspid regurgitation, "dcgi approved everolimus eluting coronary stent system, strut thickness of 65 micron,s-shaped links at every third crest along with the open cell design will ensure excellent side branch access. hybrid cell design (8 crowns) innovative hybrid design with open cells at the edges gives uniform expansion. closed cells at the ends provide optimum scaffolding and eliminates problems of edge dissections., components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.3 microgram/mm2 of stent surface area. stent diameter(mm): 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length, (mm): 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48", "ce approved everolimus eluting coronary stent system, struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length, (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47, platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty.", ce approved semi complaint ptca balloon dialation catheter diameter - 1.25,1.50,2.00,2.25,2.50,2.75,3.00,3.50,4.00,4.50,5.00 and 6.00 mm length - 10,12,15,20,25,30,35 and 40 mm, atraumatic tapered tip with enhanced pushability and lesion crossing., "ce approved non complaint ptca balloon dialation catheter diameter - 2.00,2.50,2.75,3.00,3.50 mm x length - 6,9,12,15,20,25,30 mm. diameter - 4.50 mm x length - 6,9,12,15,20,25 mm., diameter - 5.00 mm x length - 6,9,12,15,20 mm.", "ce approved cto ptca balloon dialation catheter, diameter - 1.00, 1.25, 1.50, 2.00, 2.50 mm x length - 10,15,20, mm. conical shaped tip for cto lesions, 2.5f flexible distal shaft", "ce approved non complaint ptca balloon dialation catheter diameter - 0.75, 0.85 mm x length - 5,10,15 mm., diameter - 1,00, 1.25, 1.50, 1.75, 2.00 mm x length - 5,8,10,12,15,17,26,30, mm. diameter - 2.25,2.50,2.75,3.00,3.25,3.50,3.75,4.00 mm x length - 5,8,10,12,15,17,26,30,35,40 mm.", "ce approved semi complaint ptca balloon dialation catheter diameter - 0.75, 0.85 mm x length - 5,10,15 mm., diameter - 1,00, 1.25, 1.50, 1.75, 2.00 mm x length - 5,8,10,12,15,17,26,30, mm. diameter - 2.25,2.50,2.75,3.00,3.25,3.50,3.75,4.00 mm x length - 5,8,10,12,15,17,26,30,35,40 mm.", double luman otw micro catheter for bifurcation lesion, catheter effective length 1400 mm, tip entry profile 1.4 fr, distal shaft od 2.90 fr, proximal shaft od 3.2 fr, hydroplilic coating length 270 mm, double luman otw micro catheter for bifurcation lesion, reverse wire technique, side branch access, distance from tip to otw exit port 6.5 mm, double stainless steel core, tappered short tip, hydrophilic l3 coating, 145 cm usable length, tip od 1.50 fr, distal shaft od 2.50 fr, proximal shaft od 3.2 fr, hydrophilic coating length 38 cm., "ptca balloon semi compliant, ultra low profile, small ballon size begining at, 1.00 mm, hydrophilic coating, crossing profile for 1.00 mm balloon is 0.0157 mm, tr2 hydrophilic coating, 2.3 fr low profile shaft used for 1.50 mm to 2.75 mm balloon diameter, catheter effective length 146 cm, guide catheter compatobity 5fr, nominal pressure 6 atm, rated burst pressure 14 atm", "ptca balloon non - compliant, highest rbp available, 22 atm rbp for 2.25 to, 4.00 mm balloons and 20 atm for 1.50 to 2.00 mm and 4.25 and 4.50 mm, balloon dia 1.50 mm to 4.50 mm, catheter effective length 1460 mm, 5 fr guide compatiblity, advanced hydroplilic coating, normal pressure 12 atm, distal shaft, o.d 2.5 fr ( 1.50mm to 2.00 mm balloon) o.d 2.6 fr ( 2.25 to 3.25 mm balloon) and 2.7 fr o.d for 3.50 to 4.50 mm balloon", manual aspiration thrombuctomy catheter, with large circular aspiration luman, hydrophilic coating on the distal 300 mm, removable core wire, rapid exchange mono rail system, sizes 6fr and 7fr, effective length 1400 mm, aspiration luman proximal id for 6fr 1.10 mm and 1.30 mm for 7fr, guidewire support catheter for reverse wire technique and retrograde cto work, flexible tip for reduced vessel trauma, nylon 12 shaft polimer, stainless steel braid reinforcement, effective length 135cm and 150 cm, distal tip o.d 1.4 fr, distal shaft o.d 1.7 fr, hydrophilic coating 70 cm, proximal shaft o.d 2.5 fr, "ce approved sirolimus eluting coronary stent system, strut thickness 75 microns.cocr l605 material with 2 platinum-iridium markers.fluorinated acrylate polymer., excellent side branch access.entry profile 0.016"" for navigating complex lesions.rapid exchange catheter. compatible with 0.014"" guide wire. compatible with 5f guiding catheter., overexpansion capacity s: 4.00mm m: 5.25 l: 6.00mm . np - 9-11atm rbp - 16atm abp - 22atm. side branch access s : 3.50mm | m : 3.75mm | l : 5.00mm. stent dia - 2.00, 2.25, 2.50, 2.75, 3.00,3.50, 4.00, 4.50. length : 9, 14, 16, 19, 24, 29, 34, 39, 44,, 49.", "everolimus eluting coronary stent system with length 8mm to 52 mm & diameter of 2.00 mm to 4.50 mm.crest :6 valley to valley connectors:2. material : l605 alloy (cobalt chromium). design : open cell design with valley-to-valley connectors( 55, 10 m). strut thickness : 60 mm 10 m/ strut width : struts: 65 10 m / drug dose : 1.20 g/mm2./sds: semi-compliant polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm & 52 mm/ hydrophilic coating: distal & proximal shaft of balloon delivery system., proximal shaft markers: 90 cm & 100 cm .mounted stent length and location defined by radio opaque marker band. nbp: 9 atm / (rbp): 16 atm*/ *rbp 16atm for all the variants except the ones given below whose rbp is 14atm:3.50 x 36 mm, 40 mm, 44 mm , 48 mm & 52 mm/ 4.00 x 32 mm, 36 mm, 40 mm, 44 mm, 48 mm & 52 mm stents / 4.50 mm. (se-mkr)<0.5mm (at both sides, proximal & distal). dcgi approved", abluminal coated everolimus eluting coronary stent : design : open cell , strut design : open cell with valley to valley s connectots(v2vs) , strut width: wavflo struts : 65+/-10um & valley to valley "s" connectors: 55+/-10um, guidewire compatibility : 0.014"(0.36 mm),polymer: biodegradable, strut thickness: 60+ /-, "10um, guiding catheter(inner diameter): 5 french , crossing profile : 0.97 mm( for 3mm), radial strength : 1.5n/mm , l605 stent material: cobalt chromium , number of crowns : 6 (2 - 3mm),8(3.5-4.5mm). post dialatation : 4mm(2 - 3mm),, 5.5mm(3.5- 4.5mm). diameter : 2mm-4.5 mm , length available : 8mm - 52 mm", "sirolimus eluting coronary stent system with length 8mm to 52 mm & diameter of, 2.00 mm to 4.50 mm.crest :6 valley to valley connectors:2. material : l605 alloy (cobalt chromium). design : open cell design with valley-to-valley connectors( 55, 10 m). strut thickness : 60 mm 10 m/ strut width : struts: 65 10 m / drug dose : 1.33 g/mm2./sds: semi-compliant polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm, 48 mm& 52 mm/ hydrophilic coating: distal & proximal shaft of balloon delivery system. proximal shaft markers: 90 cm & 100 cm .mounted stent length and location defined by radio opaque marker band. nbp: 9 atm / (rbp): 16 atm*/ *rbp 16atm for all the variants except the ones given below whose rbp is 14atm:3.50 x 36 mm, 40 mm, 44 mm , 48 mm& 52 mm / 4.00 x 32 mm, 36 mm, 40 mm, 44 mm, 48 mm& 52 mm stents / 4.50 mm. (se-mkr)<0.5mm (at both sides, proximal & distal). dcgi approved", "open cell waveflo struts with v2vsconnectors stent design. cobalt l 605 alloy.uniform strut dimension. 80 micron strut thickness.9 wavflo struts(crown)& 3 v2vs connectors. everolimus drug& biodegradable polymer. diameter 3.5 / 4 /, 4.5 & 4.5 overexpansion upto 6mm. strut width: 65 micron.connector width: 55 micron. crossing profile : 1 mm", "ptca non compliant balloon catheter:zero transition nbp:12 atm / rbp : 18 -20 atm / proximal shaft diameter: 2 french/ catheter working length:140 cm / material: nylon/folds :3 to 5/crossing profile: 0.0336""/marker: 2 bands/coating: hydrophilic (distal tip to guidewire exit port), hydrophobic (guidewire lumen invio)/available diameter(in mm): 1.75 , 2 , 2.25, 2.5, 2.75, 3, 3.25, 3.5 , 3.75 , 4,, 4.5, 5/available length (in mm):8, 10, 12, 15, 18/dcgi approved, ce approved", ptca semi compliant balloon catheter:p tech shaft / sub zero tappered tip/ material : pebax/folds: 3 folds/tip entry profile:0.0164"/crossing profile 0.0216 and 0.0336 / distal shaft diameter: 2.36-2.7 french/marker:2 bands/coating:hydrophilic (distal tip to guidewire exit marker); hydrophobic (guidewire lumen) / diameter (in mm) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in mm): 5, 8,10,12,15,20 / ce / dcgi approved, "non complaint coronary balloon:usable length:14cm(+/- 2 cm.). proximal shaft 2 french(0.66cm). nominal pressure: 12 atm, rbp: 20 atm, balloon length : 8,10,12 15, 18 mm, balloon diameter: 1.75, 2.2.25,2.5,2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5mm,, radiopacity: pt-ir marker, push force 1.9 newton, balloon radial growth(np-rbp)<6%, balloon longitudinal growth<2.5%, 0.43 mm tapered profile, 2mm tri-layered atraumatic tip", "complaint coronary balloon:usable length:14cm(+/- 2 cm.). proximal shaft 2 french(0.66cm). nominal pressure: 6 atm, rbp: 16 atm, balloon length : 5,8,10,12 15, 20 mm, balloon diameter:1, 1.25,1.5,1.75, 2,2.25,2.5,2.75, 3, 3.5, 4 mm,, radiopacity: pt-ir marker, push force 1.9 newton, balloon radial growth(np-rbp)<6%, balloon longitudinal growth<2.5%, 0.43 mm tapered profile, 2mm tri-layered atraumatic tip, nylo flex(crossing profile:0.034"")", "ce / hydro x coating(xd shaft, z tip balloon diameter / diameter (in mm) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in mm): 5,, 8,10,12,15,20", ce/dccgi approved / hydro x coating guidewire lumen / tep: 0.0345" / dia: 1.5- 5mm / length: 6-28mm / rbp:utpo:24 atm, "non complaint high pressure coronary balloon : proximal shaft : 2.1 french , distal shaft: 2.36 f(1.5-5mm) , tip length : 1.5mm(1.5-1.75 mm), 2mm(2-3mm),, 2.5mm(3.25 - 5mm), marker band: 1(1.5mm)(2(1.75-5mm), crossing profile : 0.0345"", coating : hydrophillic(tip-guidewire exit port)hydrophobic(guidewire lumen), nominal pressure: 14 atm, rbp: 24atm(1.5-3.5mm) 22atm(3.75-4mm)20 atm(4.5-5mm), material : nylon & pebax(dual layer), balloon fold: 3(1.5-4mm)5(4.5-5mm), balloon diameter : 1.5,1.75, 2,2.5,2.75,3.3.25,3,5,3.75,4,4.5,5mm , length : 8,10,12,15,18,22,26mm, guidewire, compatibility : 5 f & 6 f", cto coronary balloon : proximal shaft : 1.9 french , distal shaft: 2.36 f(1.5-5mm) , tip length : 1.5mm, marker band: single, crossing profile : 0.0208", coating : hydrophillic(tip-guidewire exit port)hydrophobic(guidewire lumen), nominal pressure: 6 atm, rbp: 16 atm, material : nylon, balloon fold: 2(0.85-1mm)3(1.25 mm), balloon diameter : 0.85 , 1, 1.25 mm , length : 5,8,10,15,18mm, guidewire compatibility : 5 f, high pressure balloon. higher rbp: 26 atm. lowest crossing profile : 0.33". 3 t technology(transition free zone . 0.43 mm tapered profile for lesion, 2mm tri-layered atraumatic tip). diameter: 2mm to 5mm & length 6 to 15 mm. proximal shaft : 2.1 f. distal shaft : 2.7f(2mm to 5mm). tip length: 2mm(2mm to 5 mm). marker band:2. crossing profile : 0.33". coating : profile. nominal pressure:14mm. rbp: 24mm & 26 atm. balloon material : nylon 12. balloon fold : 3, proximal optimisation technique. optimised shoulder length: 0.6mm.3 t technology(transition free zone . 0.43 mm tapered profile for lesion, 2mm tri-layered atraumatic tip). diameter: 2.5 to 5 mm & length: 6mm to 15mm. poximal shaft : 2 f . distal shaft : 2.7 f. tip length : 2 mm. crsossing profile: 0.83". coating : hydrophilic. nominal pressure: 12 atm . rbp: 22 atm., "scoring balloon catheter:catheter type: rapid exchange / guidewire lumen diameter:0.014""/material: nylon blend/balloon compiance: non compliant, /crossing profile:0.0313""/.0.79 mm/ coating(distal shaft and tip): hydro x hydrophilic coating / coating (guidewire lumen): invio hydrophobic / nbp: 12 atm / rbp: 20 atm/available diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / available length (in mm):10, 15, 20 / ce approved", microcatheter: ce certified / proximal / distal profile : 2.6 f / 2.0 f/catheter type : over the wire/ guiding catheter compatibility : 5 f / max. gw o.d.: 0.014"/ tep: 0.0190"/ innerbody lumen dia:0.0170" / innertip lumen dia: 0.0157"/ catheter ext. coating: hydrophilic (60 cm of distal catheter including tip)/ catheter working length : 135 cm (antegrade); 150 cm (retrograde) / hybrid braiding and coil construction: layers: inner layer: ptfe liner , middle layer: hybrid braiding and coil & outer layer: ultra-thin polymer jacket, semi compliant ptca balloon, rapid exchange, nominal pressure:6 atm, rbp 16 atm, meedo s coating, uv solidation, m advance tip,silicon coated inner lumen, strain relief hub. 1mm to 4mm diameter/ length : 10,15,20 & 30 mm, non compliant ptca balloon / nominal pressure: 12 atm / rbp: 22 atm. mean burst pressure: 30 atm. seamless force conduction tech. meedo s coating, strain relief hub / meedo s coating / m advance tip.diameter : 2mm to 5mm/ length: 8,10,12,15 &18 mm, "drug eluting coronary baloon : drug: paclitaxel with natural resin : shellac , available balloon length : 8mm to 52 mm , diameter: 2mm to 4.5 mm , drug dose :, 2.3ug/mm square, balloon material : polyamide , catheter design : rapid exchange delivery system , usable shaft: 140 cm., guidewire compatibility:m0.014"", guiding catheter inner diameter: 5 french(0.056"")(1.4mm)compatible, catheter outer shaft diameter(2.7 french proximal , distal 1.95 french), balloon folding: 3 , delivery system coating : hydrophilic , nominal pressure : 8 atm , rbp: 2-4 mm.....16 atm)(4.5mm....14 atm)", microcatheter: ce certified / proximal / distal profile : 2.6 f / 2.0 f/catheter type : over the wire/ guiding catheter compatibility : 5 f / max. gw o.d.: 0.014"/ tep: 0.0190"/ innerbody lumen dia:0.0170" / innertip lumen dia: 0.0157"/ catheter ext. coating: hydrophilic (60 cm of distal catheter including tip)/ catheter working length : 135 cm (antegrade); 150 cm (retrograde) / hybrid braiding and coil construction: layers: inner layer: ptfe liner , middle layer: hybrid braiding and coil & outer layer: ultra-thin polymer jacket, steerable microcatheter: 180 degree articulating coronary microcatheter: inner diameter: 0.016" ,0.021" / outer diameter proximal portion : 2.3 f& 2.7 f / usable length: 125 cm & 150 cm. / hydrophilic coating length : 80 cm & 100 cm. / max guidewire : <=0.014" , <=0.018" / max injection pressure : 6900 kpa(1000 psi) / distance from tip to 1" marker band: 0.5mm/ distance between 1" and 2" marker band: 13.5mm, des ce approved sirolimus 1.3m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters,2m of plla & plga polymers and drug coating, crossing profile 0.88mm. diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des dcgi approved everolimus 1.00m/mm2,cobalt chromium 59m hybrid ultra low thickness strut for all diameters, plla & plga polymers, crossing profile 0.88mm.diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des everolimus cobalt chromium dcga approved open and closed cell design,60m strut thickness,3m coating thickness, wider peak design and strut locking machanism for radial strength, plga polyme 1.00m/mm2 with hydrophilic coated delivery system. size 2.0 to 5 diameter and length from 8mm to 48mm, sirolimus drug eluting stent system, open & closed hybrid cell design, 63 microns struts thickness & 40 microns connectors with hydrophilic coated balloon delivery system having diameters 2 mm to 5.00 mm and lengths 08 mm to 48 mm, sirolimus drug eluting stent system, open & closed hybrid cell design, 65 microns strut thickness & 40 microns connectors with hydrophilic coated balloon having diameters 2mm 50 5 mm and lengths 8mm to 48mm, semi complaint cutting balloon dialation catheter,carbon alloy steel blades, blades working length-0.13mm with hydrosurf coating & 0.43mm short tip. size-2 to 4 dia,length-5,10,15, paclitaxel coated balloon with urea excipient, trifold & dose of 3micro gm/mm sq.diameter-2.0 to 4.5mm and length- 9 to 38 mm, semi compliant balloon ce approved, entry tip profile 0.016, hydrophilic coating with nominal 6atm and rbp 14atm, non compliant balloon ce approved, crossing profile 0.018 catheter length 141.4 cm. diameter 1.5mm to 5mm and length 8 to 40 mm., guide extension catheter with hydrophilic coating, length 1500mm. outer diameter 1.35mm inner diameter-1.17mm, 2mm soft atraumatic tip with 3mm long entry port and stainless steel collar.,
guiding catheter with flat braiding and inner diameter of 115fr-1.40mm, 6fr-1.78mm, 7fr-2.0mm, "diagnostic catheter ce approved with braided shaft and hydrophilic coated.available length 110cm and 100cm., tavr - aortic self expandable transcatheter dry tissue technology valve 23,26,29,31mm. factory loaded with straight sealing zone.", transcatheter bicaval dry tissue valves for tricuspid regurgitation, ivl catheter and non magnetic connector cable-rx for treating high calcified lesions integrated 12mm sc balloon, np-6atm/rbp-10atm. diameters 2.5,2.75,3.0,3.25,3.5,3.75,4.0., "ce approved non complaint balloon catheter, balloon size: 2.25mm 4.5mm/length: 6mm-20mm rapid exchange proximal shaft 2.3 f and distal shaft 2.7 f, tip entry profile 0.0165 and crossing profile 0.028 - 0.038 with nominal pressure 12 atm & rbp -22 atm(2.25mm-4.0mm) and 20 atm (4.50mm), and having two platinum iridum markers., ce approved semi complaint balloon catheter, inner shaft with patented 2 layer design using specialized material.", "ce approved semi complaint balloon catheter, inner shaft with patented 2 layer design using specialized material., balloon size:1.00mm-4.00mm/length : 6mm-20mm rapid exchange proximal shaft - 2.2f and distal shaft-2.1 f, crossing profile 0.021-0.027 with nominal inflation pressure-6 atm & rbp -16 atm.", des ce approved sirolimus 1.3m/mm2 ,cobalt chromium 59m hybrid ultra low thickness strut for all diameters,2m of plla & plga polymers and drug coating, crossing profile 0.88mm. diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des dcgi approved everolimus 1.00m/mm2 ,cobalt chromium 59m hybrid ultra low thickness strut for all diameters, plla & plga polymers, crossing profile 0.88mm.diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters., des everolimus cobalt chromium dcga approved 60m strut thickness,3m coating thickness, wider peak design and strut locking machanism for radial strength, plga polymer with hydrophilic coated delivery system. size 2.25 to 5 diameter and length from 8mm to 48mm, semi complaint cutting balloon dialation catheter,carbon alloy steel blades, blades working length-0.13mm with hydrosurf coating & 0.43mm short tip, paclitaxel coated balloon with urea excipient, trifold & dose of 3micro gm/mm sq.diameter-2.0 to 4.5mm and length- 9 to 38 mm, semi compliant balloon ce approved, entry tip profile 0.016, hydrophilic coating with nominal 6atm and rbp 14atm, non compliant balloon ce approved, crossing profile 0.018 catheter length 141.4 cm. diameter 1.5mm to 5mm and length 8 to 40 mm., guide extension catheter with hydrophilic coating, length 1500mm. outer diameter 1.35mm inner diameter-1.17mm, 2mm soft atraumatic tip with 3mm long entry port and stainless steel collar, guiding catheter with flat braiding and inner diameter of 5fr-1.40mm, 6fr-1.78mm, 7fr-2.0mm, diagnostic catheter ce approved with braided shaft and hydrophilic coated.available length 110cm and 100cm., tavr - aortic self expandable transcatheter dry tissue technology valve 23,26,29,31mm. factory loaded with straight sealing zone., transcatheter bicaval dry tissue valves for tricuspid regurgitation, "des, sirolimus, cobalt chromium platform with 65 micron strut ""c, and s link design with 8 crowns and schifsorb polymer coating technology size 2.25 -4.5 mm length 7 to 48mm, dcgi approval", "des, everolimus, only dcgi cobalt chromium platform with, 60 micron, strut ""c and s link design with schifsorb polymer coating technology size 2.25 -4.5 mm length 7,10,13,15,17,20,24,28,33,28,42,, 48mm", "drug everolimus stent with dcgi approval , low strut thickness of 55 microns, c chromiul605, and drug dose of 1.1umm with mri comparatable, plla@plga p laser marking lidentification and traceabilityto each device highly radiopaque a maximum expansion of 4diameters from 2mm to 4.5mm, snd lenghts 7to 48 ce approved,semi compliant balloon with tapered tip with low entry profile an, 4trifolc balloon folding and rewarp technology,with platinum -iridium marker b diameter (1,1.25,1.5,2,2.25,2.5,2.75,3,3.5,4,4.5 length(mm) - 7,10,12,14,16,18,20,25,29,34,39,43,45 3.03", ce approved non compliant balloon with tapered tip with low entry profile and elongated 4mm tip with trifolc balloon folding and rewarp technology,with platinum -iridium marker bands diameter-mm diameter (mm)- 1,1.25,1.5,2,2.25,2.5,2.75,3,3.5,4,4.5 length(mm) - 7,10,12,14,16,18,20,25,29,34,39,43,45, "ce approved,semi compliant balloon with tapered tip with low entry profile and elongated 4mm tip with trifolc balloon folding and rewarp technology,with platinum -iridium marker bands diameter (mm)-1,1.25,1.5,2,2.25,2.5,2.75,3,3.5,4,4.5 length(mm) -, 7,10,12,14,16,18,20,25,29,34,39,43,45, 3.03", ce approved non compliant balloon with tapered tip with low entry profile and elongated 4mm tip with trifolc balloon folding and rewarp technology,with platinum -iridium marker bands diameter-mm diameter (mm)- 1,1.25,1.5,2,2.25,2.5,2.75,3,3.5,4,4.5 length(mm) - 7,10,12,14,16,18,20,25,29,34,39,43,45, peripheral self-expanding stents nitinol/ eptfe, guidewire - 0.035, diameters 6, 7, 8, 9, 10, 12, 13.5mm, lengths - 40, 60, 80, 100, 120mm, delivery system lengths -80, 117cm, "nitinol stent system for sfa diameters- 5, 6, 7, 8, lengths - 20, 40, 60, 80,, 100, 120, 150, 200mm, delivery system length - 75, 130", balloon expandable peripheral stent,diameter:5mm-7mm/length:14mm 21mm, aotic stent graft, "des, everolimus,fda/dcgi/ce approved cobalt chromium platform,50 micron strut thickness,, diameter 2.25,2.5,2.75,3.00,3.5,4.00,4.5.length, 8,13,16,19,24,29,32,37,40,44,48 nominal pressure 8 atm,5 f, compatable", "des, sirolimus,fda/dcgi/ce approved cobalt chromium, platform with 65 micron strut (0.025mm), biodegradable polymer, hybrid open and closed cell structure, variable strut width.length available 8,13,16,19,24,29,32,37,40,43,47./stent balloon 0.5 longer than stent nominalpressure-9 atm rated burst pressure 14/16.sizes from 2.25,2.5,2.75,3,3.5,4,4.,", "des, sirolimus,fda/dcgi/ce approved cobalt chromium, platform.balloon overhang<0.3 mm, recoil average 3.2%, percentage foreshortening 1.3%. diameter 2.25,2.50,2.75.3.0.4.0.length 8,13,16,19,24,29,32,37,40", sirolimus eluting tapered stent,fda/dcgi/ce approved, "rapid exchange semi complaint nylon balloon.fda/dcgi/ce approved with nominal prerssure 8 atm hydrophilic coating balloon diameter 1.25,1.5,2.0,2.25,2.75,3.0,3.5,4.0,, 4.5.length6.9,12,14,15,17,20,25,30,33,38,41,45,49", rapid exchange (rx) non-compliant nylon balloon dilatation catheter has a hydrophilic coating and is available in diameters from 2.00 mm to 5.00 mm with lengths from 8 mm to 38 mm. it features platinum/iridium markers and a tip length of 3.5 0.5 mm., paclitaxel coated balloon with urea excipient,trifold &dose of 3 microgm/mm sq.diamter -2.0 to 4.5mm and length -9 to 38 mm, "rapid exchange (rx) semi-compliant sirolimus eluting balloon dilatation catheter uses a solid lipid nanoparticle (sln) formulation with sirolimus, 3.00 g/mm for controlled drug release. it has a hydrophilic coating,, ptfe-coated shaft, and is available in diameters from 2.00 mm to 4.50 mm with lengths from 9 mm to 49 mm.", rota pro-rotational atherectomy system, rapid exchange catheter is a semi-compliant balloon with hydrophilic coating, using acoustic pressure waves at 4 atm to fracture calcium. it delivers 80 pulses (mason c) or 120 pulses (mason pro c) through 2 emitters, with balloon diameters from 2.50 mm to 4.00 mm., cobalt chromium stent with 65 m strut thickness, hybrid cell design, and biodegradable plla/plga polymer carrying sirolimus 1.25 g/mm. it is available in diameters 2.004.50 mm and lengths 848 mm, with platinum/iridium markers and a rapid exchange delivery system., semi-compliant rapid exchange balloon with sirolimus 3.00 g/mm lipid formulation (i-chem technology) for controlled drug delivery. it is available in diameters 2.004.50 mm and lengths 941 mm, with platinum/iridium markers, ensuring rapid drug absorption and suitability for lesions unsuited for stents., semi-compliant rapid exchange balloon with hydrophilic coating, available in diameters 1.254.50 mm and lengths 641 mm. it features platinum/iridium markers and is optimized for seamless performance and lesion access., non-compliant rapid exchange balloon with hydrophilic coating, available in diameters 2.005.00 mm and lengths 838 mm. it features platinum/iridium markers and is designed for challenging, calcified lesions, "1) sc baloon, ptca pre-dilatation semi-compliant balloon catheter:, * monorail/rapid exchange design., * low entry profile for enhanced lesion crossing., * compatible with 5f and 6f guiding catheters., * hydrophilic-coated shaft for reduced friction and improved trackability. * dual gold marker bands for precise fluoroscopic visualization and positioning., * balloon material: pebax., * balloon diameters available from 1.25 mm to 4.0 mm., * balloon lengths available from 6 mm to 30 mm., *dcgi approved", "2) nc baloon, ptca post-dilatation non-compliant balloon catheter :, *monorail/rapid exchange design., * low entry profile for enhanced lesion crossing., * compatible with 5f and 6f guiding catheters., * hydrophilic-coated shaft for reduced friction and improved trackability. * dual gold marker bands for precise fluoroscopic visualization and positioning., * balloon material:nylon., * balloon diameters available from 1.5 mm to 4.0 mm., * balloon lengths available from 6 mm to 27, mm. *dcgi approved"
Tender247 tries to ensure accurate & authentic tender information at its level best however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before participating / submitting bid.