supply of - electric traction lifts (q2) , dismantling of passenger-cum - bed elevater-1360 kg, 20 passenger 07 landings ,elevator complete in all respect. , dismantling of passenger-cum-bed elevater-1360 kg, 20 passenger 06 landings ,elevator complete in all respect. , dismantling of passenger- cum- bed elevater-1020 kg, 15 passenger 07 landings ,elevator complete in all respect. , dismantling of passenger elevater- 408 kg, 06 passenger 07 landing ,elevator complete in all respect. ,
g of passenger elevater-544 kg, 08 passenger 07 landing ,elevator complete in all respect. , dismantling of passenger elevater-272 kg, 04 passenger 07 landing ,elevator complete in all respect. , dismantling of passenger elevater-408 kg, 06 passenger 05 landing ,elevator complete in all respect. , plaster repairs 12mm- 20mm in cement mortar , polymer modified cementitious waterproofing coating , 12mm dia gi injection nipples fixing , providing and injecting approved grout in proportion recommended by the manufacturer ry by suitable gun etc , white washing with lime to give an even shade on old work two or more coats , demolishing r.c.c. work manually or by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead , brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level up to floor v level in all shapes and sizes , reinforced cement concrete work in walls any thickness, including attached pilasters, buttresses, plinth etc , form work centering and shuttering etc , steel reinforcement steel reinforcement for rcc work including straightening, cutting, bending, placing in position and binding all complete above plinth level etc , electrical work supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 or 6 a modular etc , wiring for circuit or submain wiring alongwith earth wire with the following sizes of frls pvc etc , wiring for circuit or submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor etc , sitc of pre- wired bulkhead light in lift shafts as per the site requirement and direction , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories , supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, , supplying and fixing 25 mm x 5 mm g.i strip on surface or in recess for connections etc. as required. , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic etc , supplying and fixing following rating, four pole, 415 v, mcb tpn in the existing mcb db etc , supplying and fixing following rating, double pole, 240 v, mcb in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 a - boq of dsitc of passenger lifts | quantity - 10582
Description : - electric traction lifts (q2) , dismantling of passenger-cum - bed elevater-1360 kg, 20 passenger 07 landings ,elevator complete in all respect. , dismantling of passenger-cum-bed elevater-1360 kg, 20 passenger 06 landings ,elevator complete in all respect. , dismantling of passenger- cum- bed elevater-1020 kg, 15 passenger 07 landings ,elevator complete in all respect. , dismantling of passenger elevater- 408 kg, 06 passenger 07 landing ,elevator complete in all respect. , dismantling of passenger elevater-544 kg, 08 passenger 07 landing ,elevator complete in all respect. , dismantling of passenger elevater-272 kg, 04 passenger 07 landing ,elevator complete in all respect. , dismantling of passenger elevater-408 kg, 06 passenger 05 landing ,elevator complete in all respect. , plaster repairs 12mm- 20mm in cement mortar , polymer modified cementitious waterproofing coating , 12mm dia gi injection nipples fixing , providing and injecting approved grout in proportion recommended by the manufacturer ry by suitable gun etc , white washing with lime to give an even shade on old work two or more coats , demolishing r.c.c. work manually or by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead , brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level up to floor v level in all shapes and sizes , reinforced cement concrete work in walls any thickness, including attached pilasters, buttresses, plinth etc , form work centering and shuttering etc , steel reinforcement steel reinforcement for rcc work including straightening, cutting, bending, placing in position and binding all complete above plinth level etc , electrical work supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 or 6 a modular etc , wiring for circuit or submain wiring alongwith earth wire with the following sizes of frls pvc etc , wiring for circuit or submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor etc , sitc of pre- wired bulkhead light in lift shafts as per the site requirement and direction , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories , supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, , supplying and fixing 25 mm x 5 mm g.i strip on surface or in recess for connections etc. as required. , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic etc , supplying and fixing following rating, four pole, 415 v, mcb tpn in the existing mcb db etc , supplying and fixing following rating, double pole, 240 v, mcb in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 a
19
Days Left
Submission Date
06 OCT 2026
Opening Date
06 OCT 2026
Tender Estimated Cost
Refer Document
EMD
₹ 7.65 Lakh
Apply with Surety Bond
Tender Document Fees
Refer Document
AI Bid Assistant
Prepare a complete bid response for this tender in under 30 minutes.
Tender247 tries to ensure accurate & authentic tender information at its level best however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before participating / submitting bid.