Agency Tenders On Tender247 Bring Together Government Departments, Psus, And Private-Sector Buyers Across India Who Are Sourcing Agency Through Competitive Bidding. Tenders In This Category Typically Specify Quantity, Technical Or Quality Specifications, Delivery Schedule, And Applicable Quality Or Compliance Standards Relevant To The Item. Whenever A New Agency Tender Or Corrigendum Is Published, Tender247 Indexes It Promptly So Suppliers Never Miss A Bidding Opportunity. Suppliers Get Complete Tender Documents, Corrigenda, And Deadline Alerts For Agency Tenders Without Manually Checking Multiple Government Or Psu Websites. Track Agency Tenders On Tender247 And Set Up Custom Alerts By Buyer Or Location To Stay Ahead Of The Competition.
one time rectification of different non functional labmedical equipments, one time rectification of different non functional electro-mechanical equipments, comprehensive operation and maintenance of different types of labmedical equipment rate for 01 year, comprehensive operation and maintenance of different types of electro-mechanical equipmentsrate for 01 year
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
one time rectification of different non functional labmedical equipments, one time rectification of different non functional electro-mechanical equipments, comprehensive operation and maintenance of different types of labmedical equipment rate for 01 year, comprehensive operation and maintenance of different types of electro-mechanical equipmentsrate for 01 year
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
one time rectification of different non functional labmedical equipments, one time rectification of different non functional electro-mechanical equipments, comprehensive operation and maintenance of different types of labmedical equipment rate for 01 year, comprehensive operation and maintenance of different types of electro-mechanical equipmentsrate for 01 year
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
one time rectification of different non functional labmedical equipments, one time rectification of different non functional electro-mechanical equipments, comprehensive operation and maintenance of different types of labmedical equipment rate for 01 year, comprehensive operation and maintenance of different types of electro-mechanical equipmentsrate for 01 year
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
supply installation testing and commissioning of 2 x10 cylinder main manifold for oxygen with nrv pipe connection and with middle frame with chain compatible for control panel wall mounting type gas manifold fabricated with 58x 15 swg copper pipe as per bs en 1057 brass blocks as per is 319 equally spaced at 250 mm fitted on duly powder coated ms frame 95 x 45 hydraulically tested at 300 bar with high pressure non return valve 125 metre long 516 x l6g copper tail pipe tested at 300 bar with standards isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning of 2 x4 cylinder main manifold for oxygen with nrv pipe connection and with middle frame with chain compatible for control panel wall mounting type gas manifold fabricated with 58x 15 swg copper pipe as per bs en 1057 brass blocks as per is 319 equally spaced at 250 mm fitted on duly powder coated ms frame 95 x 45 hydraulically tested at 300 bar with high pressure non return valve 125 metre long 516 x l6g copper tail pipe tested at 300 bar with standards isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning microprocessor based 2 source fully automatic control panel lcd display -touch screen for oxygen with 40 micron filters both sides left bank right bank 2100 lpm it shall be dome loaded fully automatic control panel and shall have touch screen display the manifold shall consist of two bank regulators dome bias used to reduce the cylinder pressure to the two lines regulators which in turn controls the final line pressure the manifold has an intermediate and line relief valve that is internally connected to a common vent port terminating into a l2 fnpt pipe the header bars shall be equipped with high-pressure shutoff valves outside the cabinet to allow for emergency isolation of the header bars the header bar shall incorporate integral check valves for each station the manifold is equipped with pressure transducers which sends information to the main circuit board for operation of the fail-safe relay which transmits a remote signal to the master alarm or buzzer the external shut-off valves connecting to the header bars must be ball valves capable of withstanding pressure of 3 000 psi with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco should also be installed with leak measurement device it should be specifically designed for measuring the flow of oxygen catering to the requirements of hospital where precise oxygen flow control is critical providing features for easy installation versatile units election and comprehensive diagnostic functions it should incorporate at hermalmass flow sensor designed for measuring oxygen it should utilizes a calorimetric measuring principle eliminating the need for additional pressure and temperature measurements it should supports digital interfaces such as modbus rtu and rs485 facilitating seamless communication with other systems should also provide sanalog 420ma and pulse outputs ensuring compatibility with different data acquisition and control systems anda user- friendly display for unit selection and diagnostic functions it should be designed to achieve a high level of accuracy with specified measuring ranges 0-90 nm hand accuracy levels of 15 of measured value and 03 of full - scale value it should operate effectively in a temperature range of -3oto80c and can withstand operating pressure s ranging from-1 to 16 bar it should be with display degreased or 02 service the flowmeter should be designed for case of maintenance it should include diagnostic functions that can be read on the display or accessed remotely facilitating proactive maintenance, supply installation testing and commissioning terminal units for gas of british standard metal gas outlets with stainless steel probe are ce marked as a class iib medical device 9342eec with notified body british standards institute and stamped ce with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco it should have one-piece chromed fascia plate shall frame the outlet with the back rough-in mounted the outlet shall adjust from 38 10 mm to 1 25 mm variation in wall thickness it should have modular design and include a gas specific 16 ga 16 mm steel mounting plate designed to permit on-site ganging of multiple outlets in any order on 5 127 mm spacing it should be cleaned and degreased for medical gas service factory assembled and tested it should be indexed to eliminate interchangeability of gas services it should have 360 swivel inlet pipe for easy installation and should have universal rough-in assembly to accept quick disconnects or diss front adaptors or bs adaptors medical oxygen gas, medical air gas, vacuum, supply installation testing and commissioning of bpc flow meter with dehumidifier bottle of specifications flow range 0-15 lpm for adult accuracy 10 of the scale value or 02 lpm whichever is higher material brass chrome plated float aisi 316 with mesh filter aisi 3 16 wire mesh inletoutlet connection 38 bsp rh calibration 50 psig 345 bar at 21c operation mode manual with a knob to adjust flow supply it shall fully comply and meets with active medical device of class ila and in compliance with the en iso150022008 standard it should be duly ce marked and comply with 9342eec medical devices general it shall be ce marked with the notified body number specified it shall be provided with a copy of the certificate of origin its pressure compensated to prevent back pressure build upon flow indicator expanded scale providing higher reading accuracy durable polycarbonate flow tube with cover flowmeter should be placed in the vertical position lt should be lightweight of 200 g the flowmeters should be of 0-15 lpm range for oxygen and with inlet pressure 50-60psi 45 bar the closing of the knob should be without any leakage polysulphone 250 cc humidifier bottle should be unbreakable reusable to disinfectants and complements with standards isiso 150022008 isiso 7396-12016 a12017 htm 02-01 part a2006 cecdsco, supply installation testing and commissioning of ward vacuum unit adult 1000 ml with vacuum regulator a clear autoclavable polycarbonate jar with varying capacities a vacuum range of 0 to 760 mmhg a regulator with an adjustable knob for precise control and a gauge to measure negative pressure often with a range of 0 1o -760 mmhg the jar is designed to be shatterproof and autoclavable while the regulator typically has an aluminium body brass inner parts and a neoprene diaphragm conform to relevant standards isiso 10079-3 2014 for devices isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning of medical grade copper pipes bsen 133482016 ce cerified kite marked copper pipes used should be solid drawn seamless deoxidized phosphorus non-arsenical half hard tempered and degreased manufactured as per bsen 133482016 in cither r250 half hard or r290 hard meeting the requirements as per the medical grade copper pipe standards degreasing of pipe shall be such that there is less than20mgm2020mgdm2 of hydrocarbons on the degreased surface when tested by method specified by bsen13348 2016 1t should also have lloyd third-party inspection of copper pipes the supplier should provide manufacturers test certificate of copper pipes for physical properties and chemical composition copper pipes joined by silver brazing method for copper to brass inert gas welding technique should be used by passing nitrogen gas inside the copper pipes during brazing in order to avoid carbon deposition inside the copper pipes all copper pipes and fittings like bends tees reducers and straight couplings should be as per eni254-1 copper pipes to be fixed with walls with suitable saddles and supports after erection all the pipes should be cleaned or purged with the help of dry nitrogen gas should be tested with dry nitrogen 12 mm thickness 1 mm, 15 mm tickness 09 mm, 22 mm thickness 09 mm, 28 mm thickness 09 mm, 42 mm thickness 12 mm, supply installation testing commissioning of isolation valve of ball valve its shall have a body of brass metal ballstem shall be of stainless steel or other materials depending on the application ball valve seatsseals are made of ptfe epdm viton or other materials depending on the fluid and temperature with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco 12 mm isolation ball valve, 15 mm isolation ball valve, 22 mm isolation ball valve, 28 mm isolation ball valve, 42 mm isolation ball valve, supply installation testing and commissioning of air compressors 100 oil free oil less reciprocating piston compressor tefc motor standard with dynamically balanced flywheel for low vibration must have 5 microns oversized filter for large dirt holding capacity with electric sensor tank drain a rated control panel also provided with two-way cooling from fan and flywheel to eliminate excess heat composite piston technology with insulated wrist pin to reduce bearing heat 800 lpm, supplying installing testing and commissioning of indigenous electrical control panel for duplex vacuum duplex compressed air plant, 1000 air receiver tank, supply installation testing commissioning of heatless decicant air dryer designed for - 1so7183-1986 e dryer quality class -iso8573-12010 e class 2 pre-filter quality class - iso8573-120 10 e class 1 consistent dew point performance noise level 70 dba i pressure drop 03 kgem2 g it is of aluminium construction free from corrosion scale formation at inner and outer sides uses high crush strength adsorbent materials lt shall also consist of pre and post microbial filter of suitable grade and class 60 cfm, supply lnstallation testing and commissioning of coarase filter for medical air for oil removal coalescing and particulate its flow from 20 to 1810 m3hour particle removal 001 um, supply lnstallation testing and commissioning of activated carbon filter for medical air for odour removal and particle removal its flow from 20 to 1810 m3hour particle removal 001 um, supply installation testing and commissioning of bacteria filter for medical air of borosilicate filter element 99 995 efficiency and must compliant with health technical memorandum 2022 to meet air flow rates from 850 -7504 litresmin 30-265 scfm, supply installation testing and commissioning vacuum pump with motor starter silencer with fitting and bracket cast iron construction - cylinders and frame are designed with 100 cast iron for durability and long life cylinders - separately cast cylinders with deep fins allow for 360 cooling removing the heat of compression individual bolting of the cylinders to the frame for easy inspection and maintenance low oil level protection -the low oil level switch protects the pump from operating without proper lubrication piston rings - each piston is equipped with 2 compression rings and 2 oil control rings to maintain maximum operating efficiency and low oil carryover valves - stainless steel valves are readily accessible and inexpensively replaced if necessary connecting rods -one piece design permits precision aligned machining of both crankpin and piston pin bearings resulting in longer bearing life also allows for simple maintenance-no bolts to come loose or adjust 600 lpm, supply installation testing and commissioning of vacuum tanks tanks are designed for the safe and efficient storage of compressed medical air the air tanks meet stringent medical standards making them reliable components in hospitals clinics and other healthcare environments it shall be painted to avoid corrosion it shall be made of high-quality carbon steel to ensure durability corrosion resistance and long service life it should includes safety valves pressure gauges and drain valves to monitor and maintain safe operating conditions vertical or horizontal options to accommodate available space and facility layouts maximum working pressure is 8 bar to 13 bar custom options available as pe standard gbis01150 4-2011 hgt20584-2011 tsg21-2016 its working temperature s100c 1000 ltr for vacuum system water volume, supply installation testing and commissioning of zonal valve box with pressure gauge the valve box shall be constructed of 18-gauge steel complete with a baked white enamel finish affixed to the opposite sides of the box will be two adjustable steel brackets for the purpose of mounting the box to the structural support the steel brackets shall accommodate various finished wall thicknesses between 38and 1- 316and shall be field adjustable the frame assembly shall be constructed of anodized aluminium and shall be mounted to the back box assembly by standard 6x38 tapping screws as provided with the exception of the security valve box the removable front shall consist of an opaque window with a pull-out ring pre-mounted to the center of the window with the exception of the security valve box access to the zone shut-off valves shall be by merely pulling the ring assembly to remove the window from the frame the window can be reinstalled without the use of tools only after the valve handles have been returned to the open position with the exception of the security valve box and the alarm valve combination units the window shall be marked to prohibit unauthorized persons from tampering with the valves with the following silk-screen caution medical gas controlvalvesclose only in emergency and with the exception of the security valve box and thealarmvalve combination units each valve shall be supplied with an identification bracket which shall be bolted directly on to the valve box for the purpose of applying an approved medical gas identification label the front panel shall be labelled to instruct persons to close the valves only in an emergency the valve boxes hall be constructed so that the front panel cannot be attached to the box while any valve inside is in the closed position lt should have openings to the box sinterior shall be dust-tight it should have each pipe inside the boxes hall come with it shown pressure gauge that can be viewed through the clear window all ases and their respective gauges shall be clearly labelled with the proper color coordinationisiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco 3 gas oxygen vacuum medical air, supply installation testing and commissioning of digital medical gas area alarm it should fully complies and meets nfpa-99 standards only the alarm shall be microprocessor based witha 10screcn and capable of monitoring up to 8 sensors sensors shall be mounted locally in the rough-inbox by installing the copper pipe provided or mounted remotely sensors shall be automated for gas specific detection arca alarm shall be fabricated from18gauge steel with a 38od type k copper pipe for connection to the service line the default set-points shall be - 20 variation from normal condition in the calibration mode high lowest -points shall be adjustable by on board push buttons to view the set points and audible alarm sound level press and hold the mute button for twenty 20 seconds the digital sensors can be mounted locally or remotely utilizing shielded twisted pair wiring up to 500 ft the sensors shall be designed to create interference barrier for increased rfiemi protection the lcd brightness and volume shall be field adjustable the lcd display shall be readable in poor lighting conditions screen text shall be customizable for gas locations the sensors shall be gas specific with a diss nut and a nipple the lcd sensors operating range shall be the following mid-pressure0-99 psi oxygen and vacuum the alarm shall conform to ul standard 1069 the alarm shall comply with the electro magnetic compatibility standards fcc part1s class a and 1ces 003 class a isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 ce cdsco 3 gas oxygen vacuum medical air, supply installation testing and commissioning of horizontal vertical bed head panel double duct it shall be duly ce marked and comply with 9342eec medical devices general shall have ce no or nfpa-99 standards or cga standards or htm02-01 or eniso7396 12 it should be with 2 channels to provide a modular surface mounted unit with integrated accessory rails for equipment management it should have 2 separate partition rows wise for medical gases and electrical switch sockets length should be 1800mm all medical gas piping shall be hard-piped and brazed to a single point of connection fascia panels top middle and bottom cover panels shall be removable for access for easy installation and maintenance it should be pre-piped with provision for 2 to 6 gas outlets as required bed head panels does not include gas out let cost it should have 4 electrical sockets rj-451 rj-1 it should have one stainless steel vertical pole with iv stand and 4 hooks on which dedicated accessories can be mount out of two partitions one partitions should have medical gas piping shall be hard- piped and brazed to a single point of connection fascia panels top bottom cover panels shall be removable for access for easy installation and maintenance design to meets the need of the 1cu wards designed to makel recovery more pleasant should be made of an innovative polycarbonates hee ton to which it is applied a colorful film featuring pictures recommended by user supply installation testing and commissioning of iv pole cum syringe stand supply installation testing and commissioning of ss wire basket, hp medical gas anti-static hose assembly oxygen vacuum medical air4 medical air 7 nitrous oxide carbon dioxide, construction of manifold and plant room and electrical work in plant and manifold room
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
supply installation testing and commissioning of 2 x10 cylinder main manifold for oxygen with nrv pipe connection and with middle frame with chain compatible for control panel wall mounting type gas manifold fabricated with 58x 15 swg copper pipe as per bs en 1057 brass blocks as per is 319 equally spaced at 250 mm fitted on duly powder coated ms frame 95 x 45 hydraulically tested at 300 bar with high pressure non return valve 125 metre long 516 x l6g copper tail pipe tested at 300 bar with standards isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning of 2 x4 cylinder main manifold for oxygen with nrv pipe connection and with middle frame with chain compatible for control panel wall mounting type gas manifold fabricated with 58x 15 swg copper pipe as per bs en 1057 brass blocks as per is 319 equally spaced at 250 mm fitted on duly powder coated ms frame 95 x 45 hydraulically tested at 300 bar with high pressure non return valve 125 metre long 516 x l6g copper tail pipe tested at 300 bar with standards isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning microprocessor based 2 source fully automatic control panel lcd display -touch screen for oxygen with 40 micron filters both sides left bank right bank 2100 lpm it shall be dome loaded fully automatic control panel and shall have touch screen display the manifold shall consist of two bank regulators dome bias used to reduce the cylinder pressure to the two lines regulators which in turn controls the final line pressure the manifold has an intermediate and line relief valve that is internally connected to a common vent port terminating into a l2 fnpt pipe the header bars shall be equipped with high-pressure shutoff valves outside the cabinet to allow for emergency isolation of the header bars the header bar shall incorporate integral check valves for each station the manifold is equipped with pressure transducers which sends information to the main circuit board for operation of the fail-safe relay which transmits a remote signal to the master alarm or buzzer the external shut-off valves connecting to the header bars must be ball valves capable of withstanding pressure of 3 000 psi with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco should also be installed with leak measurement device it should be specifically designed for measuring the flow of oxygen catering to the requirements of hospital where precise oxygen flow control is critical providing features for easy installation versatile units election and comprehensive diagnostic functions it should incorporate at hermal mass flow sensor designed for measuring oxygen it should utilizes a calorimetric measuring principle eliminating the need for additional pressure and temperature measurements it should supports digital interfaces such as modbus rtu and rs485 facilitating seamless communication with other systems should also provide sanalog 420ma and pulse outputs ensuring compatibility with different data acquisition and control systems anda user- friendly display for unit selection and diagnostic functions it should be designed to achieve a high level of accuracy with specified measuring ranges 0-90 nm hand accuracy levels of 15 of measured value and 03 of full - scale value it should operate effectively in a temperature range of -3oto80c and can withstand operating pressure s ranging from-1 to 16 bar it should be with display degreased or 02 service the flowmeter should be designed for case of maintenance it should include diagnostic functions that can be read on the display or accessed remotely facilitating proactive maintenance, supply installation testing and commissioning terminal units for gas of british standard metal gas outlets with stainless steel probe are ce marked as a class iib medical device 9342eec with notified body british standards institute and stamped ce with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 cecdsco it should have one-piece chromed fascia plate shall frame the outlet with the back rough-in mounted the outlet shall adjust from 38 10 mm to 1 25 mm variation in wall thickness it should have modular design and include a gas specific 16 ga 16 mm steel mounting plate designed to permit on-site ganging of multiple outlets in any order on 5 127 mm spacing it should be cleaned and degreased for medical gas service factory assembled and tested it should be indexed to eliminate interchangeability of gas services it should have 360 swivel inlet pipe for easy installation and should have universal rough-in assembly to accept quick disconnects or diss front adaptors or bs adaptors medical oxygen gas, medical air gas, vacuum, supply lnstallation testing and commissioning of bpc flow meter with dehumidifier bottle of specifications flow range 0-15 lpm for adult accuracy 10 of the scale value or 02 lpm whichever is higher material brass chrome plated float aisi 316 with mesh filter aisi 3 16 wire mesh inletoutlet connection 38 bsp rh calibration 50 psig 345 bar at 21c operation mode manual with a knob to adjust flow supply it shall fully comply and meets with active medical device of class ila and in compliance with the en iso150022008 standard it should be duly ce marked and comply with 9342eec medical devices general it shall be ce marked with the notified body number specified it shall be provided with a copy of the certificate of origin its pressure compensated to prevent back pressure build upon flow indicator expanded scale providing higher reading accuracy durable polycarbonate flow tube with cover flowmeter should be placed in the vertical position lt should be lightweight of 200 g the flowmeters should be of 0-15 lpm range for oxygen and with inlet pressure 50-60psi 45 bar the closing of the knob should be without any leakage polysul phone 250 cc humidifier bottle should be unbreakable reusable to disinfectants and complements with standards isiso 150022008 isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning of ward vacuum unit adult 1000 ml with vacuum regulator a clear autoclavable polycarbonate jar with varying capacities a vacuum range of 0 to 760 mmhg a regulator with an adjustable knob for precise control and a gauge to measure negative pressure often with a range of 0 1o -760 mmhg the jar is designed to be shatterproof and autoclavable while the regulator typically has an aluminium body brass inner parts and a neoprene diaphragm conform to relevant standards isiso 10079-3 2014 for devices isiso 7396-12016 a12017 htm 02-01 part a2006 ce cdsco, supply installation testing and commissioning of medical grade copper pipes bsen 133482016 ce certified kite marked copper pipes used should be solid drawn seamless deoxidized phosphorus non-arsenical half hard tempered and degreased manufactured as per bsen 133482016 in cither r250 half hard or r290 hard meeting the requirements as per the medical grade copper pipe standards degreasing of pipe shall be such that there is less than20mgm2020mgdm2 of hydrocarbons on the degreased surface when tested by method specified by bsen13348 2016 1t should also have lloyd third-party inspection of copper pipes the supplier should provide manufacturers test certificate of copper pipes for physical properties and chemical composition copper pipes joined by silver brazing method for copper to brass inert gas welding technique should be used by passing nitrogen gas inside the copper pipes during brazing in order to avoid carbon deposition inside the copper pipes all copper pipes and fittings like bends tees reducers and straight couplings should be as pereni254-1 copper pipes to be fixed with walls with suitable saddles and supports after erection all the pipes should be cleaned or purged with the help of dry nitrogen gas should be tested with dry nitrogen 12 mm thickness 1 mm, 15 mm tickness 09 mm, 22 mm thickness 09 mm, 28 mm thickness 09 mm, 42 mm thickness 12 mm, supply installation testing commissioning of isolation valve of ball valve its shall have a body of brass metal ballstem shall be of stainless steel or other materials depending on the application ball valve seatsseals are made of ptfe epdm viton or other materials depending on the fluid and temperature with standards isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 ce cdsco 12 mm isolation ball valve, 15 mm isolation ball valve, 22 mm isolation ball valve, 28 mm isolation ball valve, 42 mm isolation ball valve, supply installation testing and commissioning of air compressors 100 oil free oil less reciprocating piston compressor tefc motor standard with dynamically balanced flywheel for low vibration must have 5 microns oversized filter for large dirt holding capacity with electric sensor tank drain a rated control panel also provided with two-way cooling from fan and flywheel to eliminate excess heat composite piston technology with insulated wrist pin to reduce bearing heat 800 lpm, supplying installing testing and commissioning of indigenous electrical control panel for duplex vacuum duplex compressed air plant, 1000 air receiver tank, supply installation testing commissioning of heatless decicant air dryer designed for - 1so7183-1986 e dryer quality class -iso8573-12010 e class 2 pre-filter quality class - iso8573-120 10 e class 1 consistent dew point performance noise level 70 dba i pressure drop 03 kgem2 g it is of aluminium construction free from corrosion scale formation at inner and outer sides uses high crush strength adsorbent materials lt shall also consist of pre and post microbial filter of suitable grade and class 60 cfm, supply installation testing and commissioning of coarase filter for medical air for oil removal coalescing and particulate its flow from 20 to 1810 m3hour particle removal 001 um, supply installation testing and commissioning of activated carbon filter for medical air for odour removal and particle removal its flow from 20 to 1810 m3hour particle removal 001 um, supply installation testing and commissioning of bacteria filter for medical air of borosilicate filter element 99 995 efficiency and must compliant with health technical memorandum 2022 to meet air flow rates from 850 -7504 litresmin 30-265 scfm, supply installation testing and commissioning vacuum pump with motor starter silencer with fitting and bracket cast iron construction - cylinders and frame are designed with 100 cast iron for durability and long life cylinders - separately cast cylinders with deep fins allow for 360 cooling removing the heat of compression individual bolting of the cylinders to the frame for easy inspection and maintenance low oil level protection -the low oil level switch protects the pump from operating without proper lubrication piston rings - each piston is equipped with 2 compression rings and 2 oil control rings to maintain maximum operating efficiency and low oil carryover valves - stainless steel valves are readily accessible and inexpensively replaced if necessary connecting rods -one piece design permits precision aligned machining of both crankpin and piston pin bearings resulting in longer bearing life also allows for simple maintenance-no bolts to come loose or adjust 600 lpm, supply installation testing and commissioning of vacuum tanks tanks are designed for the safe and efficient storage of compressed medical air the air tanks meet stringent medical standards making them reliable components in hospitals clinics and other healthcare environments it shall be painted to avoid corrosion it shall be made of high-quality carbon steel to ensure durability corrosion resistance and long service life it should includes safety valves pressure gauges and drain valves to monitor and maintain safe operating conditions vertical or horizontal options to accommodate available space and facility layouts maximum working pressure is 8 bar to 13 bar custom options available as pe standard gbis01150 4-2011 hgt20584-2011 tsg21-2016 its working temperature s100c 1000 ltr for vacuum system water volume, supply installation testing and commissioning of zonal valve box with pressure gauge the valve box shall be constructed of 18-gauge steel complete with a baked white enamel finish affixed to the opposite sides of the box will be two adjustable steel brackets for the purpose of mounting the box to the structural support the steel brackets shall accommodate various finished wall thicknesses between 38and 1- 316and shall be field adjustable the frame assembly shall be constructed of anodized aluminium and shall be mounted to the back box assembly by standard 6x38 tapping screws as provided with the exception of the security valve box the removable front shall consist of an opaque window with a pull-out ring pre-mounted to the center of the window with the exception of the security valve box access to the zone shut-off valves shall be by merely pulling the ring assembly to remove the window from the frame the window can be reinstalled without the use of tools only after the valve handles have been returned to the open position with the exception of the security valve box and the alarm valve combination units the window shall be marked to prohibit unauthorized persons from tampering with the valves with the following silk-screen caution medical gas controlvalvesclose only in emergency and with the exception of the security valve box and the alarmvalve combination units each valve shall be supplied with an identification bracket which shall be bolted directly on to the valve box for the purpose of applying an approved medical gas identification label the front panel shall be labelled to instruct persons to close the valves only in an emergency the valve boxes hall be constructed so that the front panel cannot be attached to the box while any valve inside is in the closed position lt should have openings to the box sinteri or shall be dust-tight it should have each pipe inside the boxes hall come with it shown pressure gauge that can be viewed through the clear window all cases and their respective gauges shall be clearly labelled with the proper color coordinationisiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 ce cdsco 3 gas oxygen vacuum medical air, supply installation testing and commissioning of digital medical gas area alarm it should fully complies and meets nfpa-99 standards only the alarm shall be microprocessor based with a 10screcn and capable of monitoring up to 8 sensors sensors shall be mounted locally in the rough-inbox by installing the copper pipe provided or mounted remotely sensors shall be automated for gas specific detection arca alarm shall be fabricated from18gauge steel with a 38od type k copper pipe for connection to the service line the default set-points shall be - 20 variation from normal condition in the calibration mode high lowest -points shall be adjustable by on board push buttons to view the set points and audible alarm sound level press and hold the mute button for twenty 20 seconds the digital sensors can be mounted locally or remotely utilizing shielded twisted pair wiring up to 500 ft the sensors shall be designed to create interference barrier for increased rfiemi protection the lcd brightness and volume shall be field adjustable the lcd display shall be readable in poor lighting conditions screen text shall be customizable for gas locations the sensors shall be gas specific with a diss nut and a nipple the lcd sensors operating range shall be the following mid-pressure0-99 psi oxygen and vacuum the alarm shall conform to ul standard 1069 the alarm shall comply with the electromagnetic compatibility standards fcc part1s class a and 1ces 003 class a isiso 7396-12016 a12017 htm 02-01 part a2006 isiso 10524-22018 isiso 10524-42008 ce cdsco 3 gas oxygen vacuum medical air, supply installation testing and commissioning of horizontal vertical bed head panel double duct it shall be duly ce marked and comply with 9342eec medical devices general shall have ce no or nfpa-99 standards or cga standards or htm02-01 or eniso7396 12 it should be with 2 channels to provide a modular surface mounted unit with integrated accessory rails for equipment management it should have 2 separate partition rows wise for medical gases and electrical switch sockets length should be 1800mm all medical gas piping shall be hard-piped and brazed to a single point of connection fascia panels top middle and bottom cover panels shall be removable for access for easy installation and maintenance it should be pre-piped with provision for 2 to 6 gas outlets as required bed head panels does not include gas out let cost it should have 4 electrical sockets rj-451 rj-1 it should have one stainless steel vertical pole with iv stand and 4 hooks on which dedicated accessories can be mount out of two partitions one partitions should have medical gas piping shall be hard- piped and brazed to a single point of connection fascia panels top bottom cover panels shall be removable for access for easy installation and maintenance design to meets the need of the 1cu wards designed to makel recovery more pleasant should be made of an innovative polycarbonates hee ton to which it is applied a colorful film featuring pictures recommended by user supply installation testing and commissioning of iv pole cum syringe stand supply installation testing and commissioning of ss wire basket, hp medical gas anti-static hose assembly oxygen vacuum medical air4 medical air 7 nitrous oxide carbon dioxide, construction of manifold and plant room and electrical work in plant and manifold room
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid