supply of decorative pole of 7-8mtr above the ground level with single armbracket hold 100w led 10k lumens street lighteach pole light is complete in all aspects with all accessories without foundation bolts in all respect with design and drawing as per satisfaction of engineer in charge, supply of mineral oxide based pigment iron oxide uv stable alkali resistant and weatherproof suitable for integrally coloured cement concrete conforming to astm c-979 complete as approved by engineer-in charge same as above qty 25kg per cum, provision for making house connection of sewer line damaged during excavation complete in all respect detail attached, provision for restoration of water connections damaged due to laying of strom water complete in all respects detail attached, supply of decorative pole of 7-8mtr above the ground level with single armbracket hold 100w led 10k lumens street lighteach pole light is complete in all aspects with all accessories without foundation bolts in all respect with design and drawing as per satisfaction of engineer in charge, supply of mineral oxide based pigment iron oxide uv stable alkali resistant and weatherproof suitable for integrally coloured cement concrete conforming to astm c-979 complete as approved by engineer-in charge same as above qty 25kg per cum, provision for restoration of water connections damaged due to laying of strom water complete in all respects detail attached, supply of decorative pole of 7-8mtr above the ground level with single armbracket hold 100w led 10k lumens street lighteach pole light is complete in all aspects with all accessories without foundation bolts in all respect with design and drawing as per satisfaction of engineer in charge, supply of mineral oxide based pigment iron oxide uv stable alkali resistant and weatherproof suitable for integrally coloured cement concrete conforming to astm c-979 complete as approved by engineer-in charge same as above qty 25kg per cum, provision for making house connection of sewer line damaged during excavation complete in all respect detail attached, provision for restoration of water connections damaged due to laying of strom water complete in all respects detail attached, supply of mineral oxide based pigment iron oxide uv stable alkali resistant and weatherproof suitable for integrally coloured cement concrete conforming to astm c-979 complete as approved by engineer-in charge same as above qty 25kg per cum, supply of decorative pole of 7-8mtr above the ground level with single armbracket hold 100w led 10k lumens street lighteach pole light is complete in all aspects with all accessories without foundation bolts in all respect with design and drawing as per satisfaction of engineer in charge, supply of mineral oxide based pigment iron oxide uv stable alkali resistant and weatherproof suitable for integrally coloured cement concrete conforming to astm c-979 complete as approved by engineer-in charge same as above qty 25kg per cum
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
...gas chlorinator system vacuume regulator flowmeter rota meter glass tube chloine pressure gauge vacuum tubing cylinder opening key, supply of 100hp air cooled panel with rotary handle 3nos power contactors ac3 duty rated at 60 ambient suitable capacity power capacitors high end electronic relay for uvov sppelr ph failure unbalance dry run preventer level controller a plus ass v plus vss with selector switch kwh meter led indicators bch make
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
cctv cameras providing and installing 7 cctv cameras - 5 cameras for stp and 2 cameras for mps complete as per satisfaction of the engineer - in - charge along with 90 days recording dvr 32 inch led screen 16 channel dvr at stp siteand 8 channel dvr at mps site with connectors cables poles and power supply with online real time output facility the cameras at both the sites ie mps and stp shall be synchronized at stp site at stp and mps site 1 no ptz speed dome 360 degree 50x zoom camera 3 no 12mm lens size 1 no 36mm size make - cp plus internet protocol minimum 5 mp wdr night vision colour mode 242 12mm very focal with extra ir cctv cameras should be installed and commissioned before starting execution of work
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
design supply installation and testing of lt control panel with change-over maindg and soft starters vfd along with distribution panel in enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay push button red plus green with element indicator onoff aluminum bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 mod bus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensor less vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensor less vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensor less 1 0 to 120hz in sensor less 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required 375 lps 22500 lpm x 42 mtr, supplying designing erection testing and commissioning of non clog for sewerage having head 42 m as per the indicated requirements of discharge in 375 lps 22500 lpm and power capacity as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
providing supplying installation testing and commissioning of oil cooled air cooled as applicable automatic servo controlled voltage stabilizer of required capacity as per site load requirement suitable for three phase 415v 50 hz ac supply complete in all respects, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 16 m as per the indicated requirements of discharge in 18000 lpm as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect 100 hp, supplying erection testing and commissioning of horizontal non clog motor for sewerage having head 16 m as per the indicated requirements of discharge in 18000 lpm and power capacity as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect 100 hp, design supply installation and testing of vfd along with distribution panel in enclosure for enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and nonload bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required 18000 lpm x 16 mtr head 100 hp
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 65hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for non clog submersible pump, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 11458 lpm and power capacity in 65 bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect, supplying erection testing and commissioning of horizontal motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 14000 lpm and power capacity in 80 bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect, supplying erection testing and commissioning of submersible motor pumping set non clog for sewerage having 60 hp as per the indicated requirements of discharge in lpm and power capacity in bhp as per is marked including all accessories like ss pipes ss chain shackle chain ss foundation bolt complete base frame monorail chain guide line auto compiling duct foot bend df bend etc complete in all respect discharge capacity - power capacity bhp -100 hp at shadipur ips, design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 100 hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for non clog submersible pump, design supply installation and testing of vfd along with distribution panel in enclosure for motor rating of 80 hp enclosure shall be ip54 the panel shall be equipped with mccb tp with suitable rating spreader link tp extended rotary handle volt meter digital volt selector switch amp meter amp selector switch ct with suitable rating control mcb sp with suitable rating pla relay pushbutton red plus green with element indicator onoff aluminium bus barsuitable rating power and control wiring labour and margin fabrication with minimum sheet thickness of 2 mm for load bearing and non-load bearing side vfd should be capable of protecting motor from high and low voltage and earth fault as well vfd should restrict harmonics up to 35 vfd should be capable of providing starting torque up to 200 while starting motor it should have class 3c3 avgconformal coating so that components are safe from dust and moisture communication -built-in rs485 modbus rtu ambient temperature -heavy duty -10 50 deg c normal duty -10 40 deg c pcb protection conformal coating complying to iec 60721-3-3 class 3c3 application humidity below relative humidity 95 rh no condensation altitude 0 to 1 000 m without deration 1 001 to 4 000 m with deration of 1 per rise in 100 m vibration up to 98 msec2 10 g global compliance ce ul rohs control method vf control sensorless vector control slip compensation closed loop vector control starting torque 200 at 05hz in sensorless vector control and 150 at 3hz in vf frequency control range 0 to 400hz in vf 0 to 300hz in sensorless 1 0 to 120hz in sensorless 2 vector frequency precision setting- digital 001hz analog 003hz 60hz base complete with all other accessories as required for horizontal non clog pump 80 hp
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
...installation of 400 mm electromagnetic flowmeter internal battery operated with integrated pressure transducer 10-year battery life mid approved and oiml compliant ip68 sensorconverter 04 accuracy 8-digit lcd and in-built gsmgprs data transmission through sim complete, providing supplying and installing 400 mm di sluice valve pn 10 with epdm rubber gasket rubber sheet ms nuts and bolts two flange joints testing and commissioning transportation loadingunloading and stacking complete as per is 14846, providing lowering laying aligning fixing and jointing 400 mm ci dismantling joint suitable for sluice valve including all jointing materials labour testing and commissioning complete, supplying and fabricating 2032 mm finished-thickness 400 mm ms flange properly ribbed and one face machined including drilling and electric arc welding to ms pipe complete, cutting of cidi pipes and making flange joints with cidims pipes or specials including rubber gaskets nuts bolts washers removal of cut pieces and all accessories for watertight joints complete for 400 mm installation, supply and installation of 600 mm electromagnetic flowmeter internal battery operated with integrated pressure transducer 10-year battery life mid approved and oiml compliant ip68 sensorconverter 04 accuracy 8-digit lcd and in-built gsmgprs data transmission through sim complete, providing supplying and installing 600 mm di sluice valve pn 10 with epdm rubber gasket rubber sheet ms nuts and bolts two flange joints testing and commissioning transportation loadingunloading and stacking complete as per is 14846, providing lowering laying aligning fixing and jointing 600 mm ci dismantling joint suitable for sluice valve including all jointing materials labour testing and commissioning complete, supplying and fabricating 2032 mm finished-thickness 600 mm ms flange properly ribbed and one face machined including drilling and electric arc welding to ms pipe complete, cutting of cidi pipes and making flange joints with cidims pipes or specials including rubber gaskets nuts bolts washers removal of cut pieces and all accessories for watertight joints complete for 600 mm installation, supply and installation of 400 mm electromagnetic flowmeter internal battery operated with integrated pressure transducer 10-year battery life mid approved and oiml compliant ip68 sensorconverter 04 accuracy 8-digit lcd and in-built gsmgprs data transmission through sim complete, providing supplying and installing 400 mm di sluice valve pn 10 with epdm rubber gasket rubber sheet ms nuts and bolts two flange joints testing and commissioning transportation loadingunloading and stacking complete as per is 14846, providing lowering laying aligning fixing and jointing 400 mm ci dismantling joint suitable for sluice valve including all jointing materials labour testing and commissioning complete, supplying and fabricating 2032 mm finished-thickness 400 mm ms flange properly ribbed and one face machined including drilling and electric arc welding to ms pipe complete, cutting of cidi pipes and making flange joints with cidims pipes or specials including rubber gaskets nuts bolts washers removal of cut pieces and all accessories for watertight joints complete for 400 mm installation, construction of valve chamber of outside dimensions 19 m 19 m including earthwork timbering concrete brickwork filling centeringshuttering reinforcement rcc manhole cover plaster and cement punning complete, labour welfare cess 1
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
...pune, 4 dismantling of existing flowmeter reinstallation of 1000 after modification on 1000 mm dia pipeline mula dam, 5 calibration and testing of electromagnetic flow meters site by comparison method with ultrasonic master flowmeter or any other standard device calibrated and tested at cwprsidemi 51 up to size 500mm, 5 calibration and testing of electromagnetic flow meters site by comparison method with ultrasonic master flowmeter or any other standard device calibrated and tested at cwprsidemi 52 above size 500 to 1000mm, 6 supply of low inductance copper conductor double shielded special cable for signal out put for shifting of display of meters wtp, 7 annual comprehensive maintenance of full bore electromagnetic flowmeter having various sizes on quarterly basis installed at various locations of centralized water supply scheme at anagar including checking inspection of normal operation for all parameters carrying out all necessary repairs cropped up during the quarter or as per emergency call including all material labour necessary spares et complete
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
...supply and delivery of electromagnetic flowmeter shall be a velocity sensing electromagnetic type microprocessor based signal converter sealed housing flanged tube meter for 10 mpa working pressure manufactured to highest standard available for mag-meters equipped with minimum six digit digital totalizers reading in units of kilolitres cubicmeter and shall be accurate within 05 of measured value shall operate within a range of 03msec to 4 msec and be constructed as followsmeter tube sensor shall be fabricated from stainless steel tube and use class pn10 flat face carbon steel flanges in accordance with is 1538 these flanges shall be welded to the flow tube the internal and external of the meter tube shall be blasted to near white and lined with hard rubber polyurethrene ptfe preferably by sbr or epdm meter tube shall have a constant nominal inside diameter offering no obstruction to the flow the accuracy should be inclusive of linearity hysteresis repeatability temperature and pressure effects coil housing shall be fabricated from stainless steel ss 304 with anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils electrode connections and wiring harness capable of submerged or buried operation with ip 68 protection signal converter shall be pulsed dc coil excitation type with auto zeroing the signal converter shall be remotely mounted away from the meter the converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions the converter shall provide an isolated 4-20 ma output into minimum 500-ohm load and a frequency output of a maximum of 0-10 khz and a scaled pulse output communication interface is rs485 hart output the microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays rate of flow and total volume converter shall be supplied with a programmable low flow drop out higher flow and empty pipe zero return the signal converter housing should be die-cast aluminium with glass window the converter cum transmitter should be fully programmable form the front facia the programming should be user friendly self-prompting menu driven flowmeter test calibration certificate from fcri flow test lab nabl accredited lab to be furnished and as directed by the dept officers, supply delivery and installation of a solar power system capable of providing power for the electromagnetic flowmeter including all necessary accessories such as solar panels charge controller battery panel box to house the flow transmitter and battery solar mounting pole frame connectors interconnecting cables and all other items required for complete operation as directed by the departmental officers, installation and commissioning of the electromagnetic flowmeter on the existing pvc inlet pipeline including cable routing for the flow transmitter unit labour charges and the provision of all necessary specials tools and tackles required for successful completion of the work
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
flowmeter shifting transportation collection of client-supplied dn500 mm krohnemarshall flowmeter from existingdesignated location and transportation to installation site including loading unloading safe handling shifting positioning and required manpowerlifting arrangements, jcb excavation site preparation excavation of existing groundroad by jcb for exposing dn700600 mm ci pipeline including removal and stacking of excavated earth preparation of adequate working space around pipeline levelling and site preparation for cutting and installation based on 8 hoursday 2 days 16 hours, dewatering arrangement providing deploying and operating suitable dewatering pump with required hosepipeline electricaldg connection as applicable and manpower for continuous removal of water from excavation and working area during pipeline cutting fitting and flow-meter installation including shifting of pump as required, generator with diesel providing suitable dg set with diesel operator cables and necessary accessories for power requirements during night-timesite work including operation fuel shifting and standby arrangement as required for cutting welding fabrication and installation activities, pipeline cutting fitting labour cutting of existing dn700600 mm ci pipeline at the approved installation location removal of cut portion cleaning and preparation of pipe ends alignment levelling fitting and jointing of the complete flow-meter assembly including skilled fitters fabricators welders helpers gas-cuttingwelding equipment tools tackles and all associated installation labour, dn600 to dn500 reduction pipe specials flowmeter assembly supply fabrication installation and jointing of 2 nos dn600 dn500 reducers 2 nos dn500 flanged tail pieces 1 no dn500 mj collar required cidims pipe pieces flanges titanlocking rings couplings suitable gaskets bolts nuts washers and allied accessories includes fabrication drilling welding cutting alignment levelling assembly and connection with the dn500 flowmeter complete in all respects, dn700 to dn500 reduction pipe specials flowmeter assembly supply fabrication installation and jointing of 2 nos dn700 dn500 reducers 2 nos dn500 flanged tail pieces 1 no dn500 mj collar required cidims pipe pieces flanges titanlocking rings couplings suitable gaskets bolts nuts washers and allied accessories includes fabrication drilling welding cutting alignment levelling assembly and connection with the dn500 flowmeter complete in all respectsnote - the size of line will be confirmed after excavation work so any one item either sno 6 or sno 7 will be executed at site depending upon the line size ie of 700 mm or 600 mm dia, testing alignment commissioning complete testing and checking of installed assembly including pipe and flange alignment level checking tightening of jointsbolts gasket inspection leakage testing rectification of minor leakage checking of flow-meter installation and assistance during commissioning in coordination with the client note - the size of line will be confirmed after excavation work so any one item either sno 6 or sno 7 will be executed at site depending upon the line size ie of 700 mm or 600 mm dia, backfilling compaction backfilling of excavated area after satisfactory completiontesting of pipeline installation including suitable approved earth filling around pipe in layers watering manualmechanical compaction proper support to pipeline and bringing the area to originalrequisite ground level, concreteroad reinstatement reinstatement of concreteroad surface disturbed during excavation including removal of damaged material preparation and levelling of base providing suitable concretemortarapproved material finishing and restoration of excavated road area to match the existing surface as far as practicable complete
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
...supply and fixing of electromagnetic flowmeter shall be a velocity sensing electromagnetic type microprocessor based signal converter sealed housing flanged tube meter for 10 mpa working pressure manufactured to highest standard available for mag-meters equipped with minimum six digit digital totalizers reading in units of kilolitres cubicmeter and shall be accurate within 05 of measured value shall operate within a range of 03msec to 4 msec and be constructed as followsmeter tube sensor shall be fabricated from stainless steel tube and use class pn10 flat face carbon steel flanges in accordance with is 1538 these flanges shall be welded to the flow tube the internal and external of the meter tube shall be blasted to near white and lined with hard rubber polyurethrene ptfe preferably by sbr or epdm meter tube shall have a constant nominal inside diameter offering no obstruction to the flow the accuracy should be inclusive of linearity hysteresis repeatability temperature and pressure effects coil housing shall be fabricated from stainless steel ss 304 with anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils electrode connections and wiring harness capable of submerged or buried operation with ip 68 protection signal converter shall be pulsed dc coil xcitation type with auto zeroing the signal converter shall be remotely mounted away from the meter the converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions the converter shall provide an isolated 4-20 ma output into minimum 500-ohm load and a frequency output of a maximum of 0-10 khz and a scaled pulse output communication interface is rs485 hart output the microprocessor based signal converter shall have a selfdiagnostic test mode and a backlit display that continuously displays rate of flow and total volume converter shall be supplied with a programmable low flow drop out higher flow and empty pipe zero return the signal converter housing should be die-cast aluminium with glass window the converter cum transmitter should be fully programmable form the front facia the programming should be user friendly self-prompting menu driven flowmeter test calibration certificate from fcri flow test lab nabl accridiated lab to be furnished
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
supply a 350mm mechanical flowmeter woltman type conforming to iso 4064 class b and the flowmeter shall be tested and certified by fcri- palakkad, dismantling the existing 350mm faulty meter and conveying and fixing the new 350mm mechanical type flowmeter, providing and laying di specials of class k - 12 suitable for push - on jointing as per is 9523 upt 600 mm dia, providing and laying di specials of class k - 12 suitable for mechanical jointing as per is 9523 upto 600 mm dia, cutting 350mm id ms pipes for making bends and other specials by gas cutting including cost of gas all labour and hire charges of tools etc complete for pipes fabricated with 8mm thick ms plates, welding 350mm id ms pipes for making bends and other specials by gaselectric welding machine including cost of gas and welding rods all labour and hire charges of tools etc complete for pipes fabricated with 8mm thick ms plates, grinding cut and weld edges of 350mm id ms pipes during fabrication work including all labour and hire charges of tools etc complete for pipes fabricated with 8mm thick ms plates, earth work in excavation by mechanical means hydraulic excavator manual means in foundation trenches or drains not exceeding 15 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift up to 15 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 mall kinds of soil, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level124 cement 2 coarse sand zone-iiiderived from natural sources 4 graded stone aggregate 20 mm nominal size derived from natural sources, centering and shuttering including strutting etc and removal of form forwalls any thickness including attached pilasters butteresses plinth and string courses etc, centering and shuttering including strutting etc and removal of form forfoundations footings bases of columns etc for mass concrete, centering and shuttering including strutting etc and removal of form forsuspended floors roofs landings balconies and access platform, providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement - all work up to plinth level1153 1 cement 15 coarse sand 3 graded stone aggregate 20 mm nominal size derived from natural sources, steel reinforcement for rcc work including straightening cutting bending placing in position and binding all complete upto plinth levelthermo - mechanically treated bars of grade fe-500d or more, supply of ci double flanged sluice valve conforming to is 14846 - 2000 sluice valve with cap pn 16 size 150mm, conveying and fixing ci sluice valves with cap by providing bolts nuts rubber insertions etc complete but excluding the cost of the valve tail pieces if required will be paid separately 150mm diameter class ii
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
design engineering supply ultrasonic flowmeter detail specification is available in tender document - volume-02 technical, non comprehensive amc for 1st year 12 months, non comprehensive amc for 2st year 12 months, non comprehensive amc for 3st year 12 months, non comprehensive amc for 4st year 12 months
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid