Glass Fabric Tenders On Tender247 Bring Together Government Departments, Psus, And Private-Sector Buyers Across India Who Are Sourcing Glass Fabric Through Competitive Bidding. Tenders Usually Specify Material Composition, Gsm Or Count, Quantity, Color/Finish Requirements, And Applicable Bis Quality Standards. On Tender247, A Search For 'Glass Fabric Tenders' Returns Every Live, Upcoming, And Recently Closed Tender For Glass Fabric, Updated In Real Time. Suppliers Get Complete Tender Documents, Corrigenda, And Deadline Alerts For Glass Fabric Tenders Without Manually Checking Multiple Government Or Psu Websites. Suppliers Of Glass Fabric Can Register On Tender247 For Real-Time, Category-Based Notifications And Never Miss A Deadline.
ml for disconnecting carefully electrical connection from both ht lt primary secondary sides of the transformer keeping them at safe side and taking out the transformervoltage stabiliser indoor outdoor type of capacity 630 kva to 800 kva 11 kv433kv step down any make for carrying out complete overhauling which shall comprise of the following- a ml for lifting transporting handling the transformer to workshop and back to the original location after complete overhauling or one location to another location where required b conducting the tests on core and windings as per is like ratio magnetic imbalance short circuit etc in presence of engr-in-charge and test results shall be signed both by the contractor and engineer -in-charge and kept on record note- i any damage to insulators bushes windings etc while in the custody of the contractor shall be made good at no extra cost to department the serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody ii ml for rewinding re-insulation of ht lt primary secondary coils bushes studs transformer oil cable box replacement of bucholtz relay mog if any etc will be measured and paid separately, all as per item no 1 herein before but transformervoltage stabiliser indoor outdoor type of capacity up to 400 kva to 500 kva complete all as specified and directed by engr-in-charge, all as per item no 1 herein before but transformervoltage stabiliser indoor outdoor type of capacity up to 100 kva to 315 kva complete all as specified and directed by engr-in-charge, ml for filtration of transformer oil of transformersservo voltage stabilizer installed at various locations to achieve di-electric strength not less than 60 kv at 25mm gap as per relevant is with portable filtration plant testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and directed by engr-in-charge, supply and topping up of transformer oil with di-electric strength not less than 60 kv in to the conservator tank body tank of the transformersservo voltage stabilizer etc at various locations complete all as specified and directed by engr-in-charge make power oil transol sabitha chemicals as approved by ge, ml for rewinding of distribution transformersavr of capacity 100 kva to 800 kva type by winding the low insulationdefective coils of primary coil ht coil with new copper wire as per is of same gauge and existing size together with new insulated materials bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber testing and commissioning the transformer and recording the test results complete all as specified and directed by engr-in-charge note ml for re-insulation of serviceable coils will be measured paid separately under relevant items, ml for rewinding of distribution transformers of capacity 100 kva to 800 kva type by winding the low insulated defective coils of secondary coil lt coil with new copper wire as per is of same gauge and existing size together with new insulated materials bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber testing and commissioning the transformer and recording the test results complete all as specified and directed by engr-in-charge note ml for re-insulation of serviceable coils will be measured paid separately under relevant items, ml for re-insulating windings of distribution transformers of capacity 100 kva to 800 kva size type by strip opening of ht lt coils ie primary secondary coils from core assembly safely unwinding the ht lt coils ie primary secondary coils complete removing the old defective insulation paper and replacing with new dpc insulation to the copper conductor re-varnishing of the windings with super varnish including heating drying backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per is 1986-87 and complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, 500 kva to 800 kva, 100 kva to 400 kva, shifting the transformeravr 100 kva to 800 kva from existing site to another site by dismantling of ht and lt cables jumpers and bus bars including lt busbar cable boxes and close the transformers for loading into vehicle with the help of crane transportation to another site unloading cable connections both ht and lt testing and commissioning complete all as specified and directed by engr-in-charge, ml for replacement of silica gel breather assembly complete with breather unit and silica gel including connecting with proper necessary gaskets if necessary including removing the unserviceable breather assembly complete all as specified and directed by engr-in-charge, ml for replacement of gun metal drain valves of transformers of following capacities including dismantling old one complete all as specified and directed by engr-in-charge make - upadhyay leader zoloto, supply and fixing in repairs off load tap changer assembly suitable for any make with 7 tapping position including opening top cover conservator etc complete all as specified and directed by engr-in-charge, supply and replacement of wti winding temperature indicator of following distribution transformers including dismantling old one complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, 500 kva to 800 kva, 100 kva to 400 kva, ml for replacement of oil gauge glass with gaskets of the following capacity distribution transformers of any makesizetype including dismantling old one complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, ml for replacement of oti oil temperature indicator of following distribution transformers including dismantling old one complete all as specified and directed by the engr-in-charge, ml for replacement of drain plugs to valvesconservator caps of the sizes 34 1 15 valves and plugs of 100 kva to 800 kva capacity distribution transformers of any makesizetype all as directed including dismantling old one complete all as specified and directed by the engr-in-charge, supply and laying of graded coarse aggregate of size 20 mm dia size upto height of 010 mtr in outdoor sub-station yards including surface dressing nexc 05 cm deep and removing debris to a distance nexc 50 m before laying of sand complete all as specified and directed by the engr-in-charge note punned thickness will be measured and paid separately for sand, material labour for excavation in trenches not exceeding 15 metre wide not exceeding 15 meter in depth for foundation laying of cable or pipe where provided for protection of cable or fixing with poles and stays and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the engr-in-charge, material labour for returning filling in including spreading levelling watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the engr-in-charge, material labour for removal excavated material ie soil from site to a distance n exc 50 mtrs away and depositing where directed at a level n exc 15 mtr above the starting point complete all as specified and directed by engr-in-charge, material and labour for river washed and screened dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed by the engr-in-charge note measurement shall be taken after punning down, supplying and laying reinforced precast concrete cable cover class hv type 1 flat size 300mmx 180mm x 40mm laid along alignment of cable as protection to cable in trenches complete all as specified and directed by engineer-in-charge, ml for gi pipe light grade 80 mm dia for cable protection on road crossings plinth protection with fixed to the pole wall etc suitable fittings for cable protection, testing the cables with high voltage dc testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault disconnecting faulty 11 kv ht cables of different sizes from both ends removal of fault re-connections and testing of cables after removal of fault complete all as specified and directed by the engr-in-charge note a 11 kv ht cable joints shall be measured and paid for separately under respective items of schedule b retrieved old serviceable cable cover will be laid in trenches for cable protection if extra pcc cover and sand required at site shall be measured and paid separately under respective items of boqs c excavation and earth work will be measured and paid for separately under respective items of schedule, ml cable jointing kit for 11 kv earthed grade xlpe cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armored aluminium conductor cable of size 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge note earth work will be measured and paid separately, ml cable jointing kit for 11 kv earthed grade xlpe cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armored aluminium conductor cable of size 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge note earth work will be measured and paid separately, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 95 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 120 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 185 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 240 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 300 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, servicing inspecting checking overhauling cleaning by using of blower lubrication greasing and carrying out preventive maintanance of rmu capacity 11 kv 250350 mva including calibrating the relay by conducting secondary injection tests and rmu in serviceable condition testing and commissioning complete all as specified and directed by the engr-in-charge notes i the rate quoted shall be deemed to include for necessary tp nuts bolts washers gasket insulation tape compound painting of rmu panels with approved colour including lettering details all as per exisitng etc, self powered relay with oc sc ef protectionrelay should have a front usb port for laptop interface lcd display 10 event records 5 fault records min 2 setting group and keypad for setting parameters for the relay suitable fo rmu, ct having ratio 100-501-1a for class - 10 25va for metering and class 10p10 25va for protection- 1set, cable termination bushing suitable for upto 1 run 3cx185 sq mm xlpe cable- 1set, cable termination cover boots push on type -1set, three phase ryb indicating lamps - 1set, 11kv230v ac 1kva control transformer - 1no, battery and battery charger 12ah ip-230v ac op - 24v dc - 1no, spring charging motor, ml of notice plate of 16 mm thick mild steel sheet vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with ms clamps bolts and nuts of approved size for ht 11 kv of size 25 x 20 cm, disconnection and taking out the idmt numeric microprocessor based relay of any type of any make from 11 kv ht panel cleaning the contacts calibrating the relay by conducting secondary injection tests checking of current transformer rectification of defects in control wiring for proper tripping of circuit breakers through cts and relay and tripping coils adjustmentsetting to plug and time multiplier settings of the relay to achieve the discrimination in tripping tunesynchronise upstream breaker relay settings re-installation of relay testing commissioning etc complete all as specified and directed by the engr-in-charge note the contractor has to arrange necessary testing kits testing equipments tools etc rental rates for the testingcalibration kits connected equipments are deemed to be included in the quoted rate testing tuning shall be carried out in the presence of representative of the department to the satisfaction of the department, taking down ht switch gear vacuum circuit breaker at sub stn of capacity 11 kv 250350 mva comprising of repairs complete overhaulingservicing carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repairs overhauling note i the servicing includes for busbar duct chamber cable alleys and connecting accessories ii the rate quoted shall be deemed to include for necessary tp nuts bolts washers gasket insulation tape compound painting of vcb panels with approved colour including lettering details all as per existing etc to put in to the vcbs and panels in serviceable condition testing and commissioning all as specified and as directed by the engineer-in-charge iii major spares like breaker bushings vacuum interrupter assly busbar spout busbar spout connections circuit spoutcircuit spout connectionsbuffer fixed contacts moving contacts tank asslybarriers solenoid spares dependentspring mechanism motor mechanism trip unit etc will be measured and paid separately under relevant items of schedule a however the rate quoted shall be deemed to include for any other minor spares require replacement iv the servicing shall be carried out by auhtorised agencyrep of oem of vcb, supplying and laying as replacement in sub station 33 to 11 kv electrical insulation mat of size 5 mtr x 1 mtr x 25 mm thick confirming to is 15652 2006 complete all as specified and directed by engineer- in- charge, platform - ml for brick masonary using sub class b brick platform of size 3m x 3m x 1m height built in cm 14 complete incl all necessary excavation earth work pcc 148 type d-2 in foundation 15 mm thick rendering in cm 16 on sides and top of the brick work up to 150 mm below ground level incl sf of 02 nos ms channels of size ismc-100 for balancing of transformer embedded in pcc 124 type b-1 up to 100 mm thick rcc 124 with 10 mm steel bar placed 100mm cc including provn of steps on one side complete all as specified and directed by engineer- in- charge, fencing - ml for perimeter fencing of size 8mx4mx2m as per site condition having ms work of angle iron for post and struts of fencing around the transformer plinthsubstationlt panels etc drilling holes flat iron fillet for securing wire mess by welding to angle iron frame and framed work as in doorgate of angle iron and wiremeshdoor to be fixed by 03 nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed by engr- in- charge details are as follows- a angle iron post to post distance maintained not more than 02mtr size of angle shall be 40x40x5mm angle iron shall be embedded in natural ground not less than 090 m deep b ms wire 75x75mm mesh 315 mm dia 2mtr height and shall be fixed to post with flat iron 32 x 6 mm fillet with two coats of synthetic enamel paint over a coat of red oxide primer c cement concrete type d-2 148 using grade crushed stone aggregate for mass concrete foundation d brickwork with subclass b bricks straights or curved on plane exc 6m mean radius built in cement mortar 16 complete for toe wall along the perimeter fencing the toe wall shall be one brick thick 30cm high 15cm above gl and 15cm below gl on 75mm thick pcc lean concrete e the exposed surfaces of brickwork shall be rendered 15mm thick in cm 14 finished fair and even without using extra cement f the steel gate shall be of size 100m x200 m fabricated from angle iron 40x40x5 mm frame and 12x12 mm square guard bars g all the exposed surfaces of steel shall be painted with two coats of synthetic enamel paint over one coat of red oxide primer h dry stone aggregate of size 40mm spreaded leveled compacted up to 100mm thick j necessary excavation and earthwork shall be included in the quoted rate, m l for painting of vcb with si-coat 570 rtv silicone high voltage insulator coating solution prior to cleaning the complete paint surface with silica paper blower heat blower complete all as specified and directed by the engr-in-charge, supply of ht insulation tape complete all as specified and directed by the engr-in-charge
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
comprehensive maintenance of electrically operated washing machine make nat steel equipments 50 kg capacity front loading type steam heating arrangement auto controlled with electric motor 3 ph 415 v 5 hp including maintenance of electrical control panel door seal door locking arrangement maint of shaft pulley inner drum descaling of inner drum and connected pipelines including replacement of all minor spare parts adjustments lubrication etc except major items mentioned hereafter in boq complete all as specified and directed 5 nos machine for a period of 6 months, comprehensive maintenance of electrically operated hydro extracting machine 25 kg capacity make nat steel equipments xsoni system auto controlled with elect motor 3 ph 415 v 5 hp including maintenance of complete electrical control panel door seal door locking arrangement leg spring inner drum when plant is running complete including minor spare partsadjustments lubrication except major items mentioned hereafter in boq complete all as specified and directed 4 nos machine for a period of 6 months, comprehensive maintenance of electrically operated hydro extracting machine 50 kg capacity make nat steel equipments xsoni system auto controlled with elect motor 3 ph 415 v 5 hp including maintenance of complete electrical control panel door seal door locking arrangement leg spring inner drum when plant is running including minor partsadjustments lubrication except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maint of air compressor 10 kg per cm 2 capacity make l-hg khosla including minor repairs and topping up of mobil oil periodically approx 5 ltrs including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of pneumatically operated steam heated auto temperature controlled flat bed press of size 750 x 1500 mm make xsoni system including cleaning of padding cloth descaling of steam pipeline including replacement of all minor spare partsadjustments lubrication including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 3 nos machine for a period of 6 months, comprehensive maintenance of steam boiler oil fired type fully automatic of capacity 600 kghour having fuel pump motor 3 ph 415 v 2 hp thermax model rxa-6 including overhauling of pump set tuning of pumps lubricating cleaning of head chimney using iron brush cleaning of economiser etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of electrically operated front loading sluice machine make nat steel equipments 15 kg capacity auto controlled having separate electric motor 3 ph 415 v 2 hp 3 hp washing and extraction including maintaining of complete electrical control panel shaft pulley door seal locking arrangement etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 3 nos machine for a period of 6 months, comprehensive maintenance of calendering machine make snow white roller type of size 24 x 3 incl testing of steam valve lubricant of gear system adjustment of chain pneumatic valve replacing of twin threads descaling of strainer including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of drying tumbler end loading type of capacity 25 kg make nat steel and 50 kg make-xsoni system including aligning lubricating and cleaning of gear monthly etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of autoclave machine at ot including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of autoclave machine at cssd including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required sizeexcept major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of dry cleaning machine at laundry including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of sterilizer machine at laundry including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, ml for rewinding of electric motor induction 3 ph 415v 50 cs 5 hp capacity with suitable size of copper wire as per existing and insulating materials heat varnishing including replacement of ball bearing 2 nos as per existing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 3 hp capacity with suitable size of copper wire as per existing and insulating materials heat varnishing complete including replacement of changing of ball bearing 3 nos as per existing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 2 hp capacity with suitable size of copper wire and insulating materials heat varnishing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 1 hp capacity with suitable size of copper wire and insulating materials heat varnishing complete all as specified and directed, opening the top cover of boiler and all connecting fittings and taking out top cover incl defective refractory and cleaning for the boiler descaling of steam coil by suitable descaling compound and re fixing the top cover by replacement suitable size nuts bolts as asbestos rope packing etc complete all as specified and directed, photo cell, diffuser plate-stud, nozzle 6-5 gph 450 degree, packing-asbestos, packing-hylam, electorde-bush, ignition electrode-rod each set, hose pipe braied dia 1 as per samle, ignition electrode -cap -api 15017170, wegman cone - dia 250 - h, belt v- belt as pe sample- a 56, pid control-selec-tc-513ax-ns207- ip-rtdtc 1coc rly 1sp 48x48, pr switch -01 to 11 bar, pr gauge brdn-wpcpb - 0-25 kg d100 38 bspt pcb, pr gauge ksch-rfm 4 rb63 0-4 bar d63 rp 14 bt, ign trans-230 vct-145kv 500va, pr switch -1 to 16 bar, diffuser plate -dia 136- rx-06, sp-dkolb water pump -triplex capacity-2160 lithr rpm 950 triplex make-dampt kolben or equivalent as approved by ge, gear pump oil pump as per existingsample, sequence controller with ase ma 810 as per existingsample, fuel pump aj6ac poif 510030 for boiler, safety valve as per existingsample, 20 mm non return valve as per existingsample, stop valve flange type as per existingsample, top refractory as per existingsample, removing heavy weight steam coil from the boiler shell establishing leakage damage of existing coil by hydraulic test replacing with new heavy weight steam coil makesagar for replacing worn out defective fittings including heat proof metallic gasket makechampion brand and testing on load of two hours installation testing and commissioning complete all as specified and directed, st suction en 05-15, oil filter en 5-15, st separator en 5-15, air tube xp5l, st solenoid 2-1524 ac, compressor oil, add-on block no-nc, push button, indicator light led, dtc temp, solenoid valve, pneumatic valve, pneumatic gland, dtc timer, bed spring heavy and high tension, pillow block bearing ucp-211 make - nat steel, pillow block bearing ucp-509 make - nat steel, oil seal as per existingsample, roller micro switch, steam stop valve 25 mm 20 mm make neta or equivalen, overload relay as per existingsample, ci pulley as per existingsample, main drive ci pulley as per existingsample, v belt no b-59, v belt no b-60, gland packing, for hydro big, for hydro small, descaling of stainless steel drum by proper descaling compound to remove scale from the perforated body for proper cleaning of cloth and economy usage of steam complete all as specified and directed, sf in replacement limit switch for washing machine sluicing machine drying tumbler calendering machine hydro extractor boiler autoclave machine as per existingsample complete all as specified and directed, contactor 9 amp, contactor 18 amp, contactor 25amp, contactor 32 amp, oil seal as per existingsample, brake shoe assembly complete with liner as per existingsample, ci pulley as per existingsample, door gasket as per existingsample, main shaft as per existingsample, v belt as per sampleb-68 and a-58, leg shaft as per existingsample, ball bearing as per existingsample, hydro balancing spring, hydro rubber buffer, hydro balancing spring bush, collar bush, belt adjusting clamp, sf in replacement inner ss drum for 25 kg hydro extractor - as per existingsample make -nat steel complete all as specified and directed, electric heater 1 kw fin type as per existingsample, v belt as per sample belt no-b-75 b-94 a-64, ball bearing as per existingsample, timer 0-60 min, push button with nonc, dtc, add-on block no-nc, blower fan, door gas kit, teflon wire 10mm, electric heater 15 2 kw fin type as per existingsample, pneumatic on of valve, 14 double pilot air valve incl fittings, v belt as per sample belt no-b-36, add-on block no-nc, push button, indicator light led, solenoid valve, air pipe, tongal switch, vspd 2, feeding belt, guide belt moq, padding, steam steel hose pipe 1 inch, air solenoid valve, namda cloth, sf in replacement ball valve of size 50 mm dia as per existingsample complete all as specified and directed, cleaning of underground dlpp tank of 5000 ltr capacity by removing the accumulated dirt with scraper iron brush etc complete all as specified and directed, cleaning of oh dlpp tank of 500 ltr capacity by removing the accumulated dirt with scraper iron brush etc complete all as specified and directed, door gasket of suitable size as per existingsample make nat or equivalent, door start pine, heating element 6kw make nat or equivalent as per existingsample, channel jacket pipe, 12 ss connector male thread, 12 ss connector female thread, boiler gasketnew type, float switch, float switch gasket, door hub part no-84199090, door handlebig part no-84199090, diaphragm plate part no-84199090, diaphragm gasket part no-84199090, solenoid valve 15mm complete set steamline make-avcon or equivalent as approved by ge, solenoid valve 20 mm complete set waterline make-avcon or equivalent as approved by ge, solenoid valve 25 mm complete set waterline make-avcon or equivalent as approved by ge, door bracket pin, sensor adjustable 20 mm bsp6make- simplex, relay card for autoclave machine, ball valve 15 mm, ball valve 20 mm, alane key bolts as per sample, v belt as per existingsample, ball bearing as per existingsample, door gasket, ml for fabrication of ms base made of ms channel of size 50 x 100 mm 6 mm thickness and length 12 to 15 m including reinforcement as per direction and grouting 04 nos bolts of size 58 x 6 long including the taking out old unserviceable existing base with washing sluicing machine and fixing new base frame with installation washing machinesluicing machine including necessary cement work including with dismantling of old worn out base plate complete all as specified and directed, ml for opening of chimney at both end of boiler and central exhaust system cleaning of shunt carbon from both end of central exhaust system of both the boiler chimney including replacement of gasket nut bolts complete all as specified and directed, sf in replacement ss door lock for washing machine complete all as specified and directed, ml for repairs to hydro extractor by replacement of bright rod with nuts for foundation base frame - 03 nos grouting bolts nuts - 03 nos repair of main ss drum - 01 no pulley shaft - 01 no foundation frame with necessary machining work as per site requirement - 01 no 03 hp motor hanger as per attachment - 01 no complete brake shoe assembly - 01 no leg shaft - 03 nos gm main check nut of centrifugal ss drum - 01 no and necessary repairs of ci housing if required and assemble all parts and balancing ss centrifugal drum after disconnection of electrical as well as mechanical connections etc and re-installing the complete hydro extractor along with reconnecting all electrical connections and mechanical connection after performing a test load for 1 hour complete all as specified and directed, ml for descaling of ss boiler tank of autoclave machine by opening of drum removing of old worn out steam gasket and ss nuts bolts and taking out all heating elements along with disconnecting electrical connection complete and descaling the tank with proper descaling agent refixing of all electrical connection and heating element and also replacing diaphragm gasket and other necessary steam gasket ss nuts bolts testing complete twice in a year complete all as specified and directed, supply and fix in repairs after taking down the old unserviceable one mcb spn up to 32 amp 10ka breaking capacity 230240 volt ac as specified and directed make- legrand cat no-4085 28 to 4086 36 or equivalent model of indoasian havells l t, sf in replacement mcb sp 6-32 amp c curve 10ka breaking capacity 230240 volt ac complete all as specified and directed, 25 mm bore, 40 mm bore, 80 mm bore, 20 mm bore, 25 mm bore, 50 mm bore, sf in replacement single phase preventer auto reset 50 v unbalance complete all as specified and directed make minilec cat no vsp3 or equivalent as approved by ge, suppyly only dry cleaning machine chemical tetrachloroethylene perchloroethylene perc complete all as specified and directed, vacumm pump lx-2 3 hp, air compressor st v belt xpz 108t, st interface valve net en11, drain valve assembly wi04ggas valve w2, sf in replacement of out dia connector of ss drain of washing machine of both end including shaft as per existingsample with complete fabrication and foundation complete all as specified and directed, sf padding for hydraulic press complete all as specified and directed, sf in replacement air exhaust system for dry cleaning machine complete all as specified and directed, sf in replacement temperature to frequency convertor for steriliser machine complete all as specified and directed, sf in replacement door frame with heatproof glass and heat proof gasket for dryer complete all as specified and directed, ml for complete overhauling and repairs of high-pressure triplex reciprocating boiler feed water pump scope includes dismantling the pump assembly replacement of worn-out eccentric shaft main bearings high-pressure plungers fluid-end suctiondelivery valve kits v-packings and oil seals item includes crankcase oil replacement re-coupling alignment with motor and pressure testing at rated boiler operating pressure to ensure leak-free performance complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
excavating in trenches nexc 15 mtr wide and nexc 15m in depth for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out on any type of soil complete all as specified and directed, excavating in trenches nexc 15 mtr wide and nexc 15m in depth for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out in hard and dense soil complete all as specified and directed, excavating in trenches exc 15 mtr depth and nexc 15 mtr wide for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out on any type of soil complete all as specified and directed, returning and filling in including spreading and levelling watering and well remming in layers not exc 25 cm all as specified and directed, removing excavated soil to a distance nexc 50 mtr and depositing where directed at a level nexc 15 mtr above the starting point all as specified and directed, supply laying testing commissioning of ht 33 kv earthed isi marked xlpe insulated screened pvc bedded electric power cable heavy duty with aluminium conductor 33000 volts grade circular screened with extruded semi conducting compound in combination with copper tape inner sheath of pvc tape galvanized steel strip flat around and overall pvc sheathed armoured conforming to is 7098 part ii 1985 amended upto date of size 3 core 300 sqmm isi marked laid in trenches or passing through pipesducts including taking down old cable of any size all as specified and as directed note - 1 excavation and earthwork sand cushioning gi pipe cable protection shall be measured and paid separately 2 cable shall be tested at high voltage test before after laying 3 no straight through joint shall be permitted inside pipe or duct 4 cost of straight through joints required if any shall deemed to be included in the quoted rates of cable, supply and fixing in replacement of ht single core power cable 11 kv isi marked earthed strandred of size 95 sqmm compacted circular aluminium conductor conductor screen with extruded semiconducting compound xlpe insulated insulation screening with extruded semiconducting compound in combination with copper tape aluminium round wire armored and frls pvc inner and outer sheathed oxygen index cable confirming to is 7098 part ii 2011 up to date amendments complete all as specified, supply lay hdpe dwc pipe 110mm bore for laying of ht cables etc complete with all jointing accessories all as specified and directed, sf steel tubing gi light grade of size 80mm bore dia for cable protection passing under road floor or for fixing to poles all as specified and as directed, ml for cable jointing kit for 11 kv grade cable for straight through heat shrinkable joint suitable for xlpe armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed make dension m sealsiemens, all as per item no 10 above but 120-185 sqmm 3 core all as specified and directed, ml for end termination cable jointing kit for 11 kv grade cable heat shrinkable joint out door suitable for xlpe armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 95 sqmm all as specified and directed make denson m sealsiemens, all as per item no 12 above but 120-185 sqmm 3 core all as specified and directed, all as per item no 12 above but 240-400 sqmm 3 core all as specified and directed, ml for end termination cable jointing kit for 33 kv grade cable heat shrinkable joint out door suitable for xlpe armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 300 sqmm all as specified and directed make denson m sealsiemens, m l for checking of ht ug 11 kv xlpe faulty cable with ht ug cable fault locating testing machine rectifying the fault putting the jointing kit and charging the cable approx length 650 rm for each job complete as all as specified and directed the rate for excavation removing of old cable laying after repairs is deemed to be included in the rates quoted, dismantling of existing unserviceable ht lt poles of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata demolition of concrete disconnecting of conductor etc all as specified and as directed, ml for cement concrete 148 type d2 using graded stone aggregate as in foundation for pole including necessary form work all as specified directed, demolition of cement concrete as in pole coping and depositing where as directed, ml cement concrete 136 type c1 using graded stone aggregate as in foundation for pole including necessary form work all as specified directed, dismantling of unserviceable existing cross arms made from channels angles and unserviceable fi clamps nuts bolts etc from oh line and removing complete all as specified and as directed, ml for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts botls washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide primer one under coat and one inishing coat of aluminium paint all as specified and as directed, dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed, ml for pin type porcelain vitreous brown or green insulator including one galvanised mild steel spindle steel washers and one galvanised nut of size 150mm height 150mm dia for 11000 volts grade complete all as specified directed, m l for disc type porcelain vitreous white or brown 145 mm height 255 mm dia ball and socket type complete with tension assembly clamps for conductor for 11000 volts grade single disc assembly complete all as specified directed, dismantling carefully the existing unserviceable htlt overhead line acsr conductor of any size from its position by necessary disconnecting of conductor and removing complete, supply and stringing new acsr conductor weasel ferret for over head line securing on pole complete including binding wire jointing sleeves aluminium tap and pg clamp etc of any size all as specified and as directed note - a jumper on cutout point2 pole structure4 pole structure shall be provided with pvc insulated sleeve b rate is inclusive of jumper tree branch cutting to make a safe distance from over head line, sf in repairsreplacement of continuous gi earth wire 4mm dia on cross of poles for guarding including binding with aluminum wire 16 swg etc and dismantling of old broken guarding complete all as specified and directed, ml for restringing of ht over head line consisting of 3 conductors by dismantling taking down repairing wherever required including cutting re-jointing and restringing in situ with proper sag binding to insulator with and including aluminium binding wire complete all as per specified and directed, sf jumpers in replacement made out of 61 x 259 mm weasel acsr conductor including pvc alkaline pipe and nuts bolts etc all as specified and as directed, sf jumpers in replacement made out of 61 x 472mm dog acsr conductor including pvc alkaline pipe and nuts bolts etc all as specified and as directed, dismantling of unserviceable stay assembly carefully including stay wire including necessary excavation and earth work in any type of soil demolition of pcc of any type and removing from site al as specified and as directed, sf in replacement of galvanized ms stranded stay wire of size 74mm including necessary binding straightening complete all as specified and directed, s f in replacement of loop type insulators vitreous porcelain white brown or green large size with over all dimensions 140mm clearance of hole 255mm including necessary cutting jointing all as directed by engr-in- charge, sf stay assembly complete with accessories as shown in electrical plate no 1 of ssr 2009 part i using stay rod 20mm dia including clamps made out of 50 x 6mm ms flat ms galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm and conductor all as specified and as directed note loop type insulator stay clamps excavation and concrete shall be measured and paid separately, m l for replacement of danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with ms clamps of size 25x4mm bolts and nuts of approved size for ht 25x20cm size complete all as specified and directed, ml for pruning and removing of tree branches touching to electric over head lines wild growth around lt ht over head lines and around pole and stay complete to make clear span of 15 mtr of tree both sides of the oh line with jcb hydraulic vehicle cutter and all tools plants etc all as directed by engineer-in-charge note i distance between pole to pole will be measured and paid ii any breakdown of line caused during pruning shall be made good without any extra cost iii the contractor shall ensure proper safety of the tradesmans to avoid any mishappening if any mishappening occures the contractor shall be solely responsibleiv laddervehicaltansport required for tree cutting shall be supplied by contractor at his own arrangement cost of vehicaljcbladdermanpower included in quoted rates, sf in replcement of vertical type air break switch gang operated triple pole mechnically operated outdoor type with all fittings and accessories mounted on and including ht 11 kv porcelain insulators 9 nos and steel channel frame gi operating rod 25 mm dia of suitable length to worked from ground including locking arrangements suitable for 11000 volts 400 amps current rating complete including dismantling existing one all as specified and as directed, repair maint of air break switch by replacing stationary and moving contacts flexible copper chord gi nuts bolts etc including alignment for smooth functioning from ground level all as required at site and all as specified directed, sf in replacement of ht 11 kv out door non-linear type lightening arrestor with mountings accessories complete fixed on cross arms of two pole structure gi flat strip and connect with same size of acsr conductor encased in pvc alkathine pipe with all fittings connected to earth strip with nuts bolts and washers transmission class having discharge capacity of 65 ka and rupturing capacity 5 kva and suitable for working pressure 9 kv rms complete including taking down old lightning arrestor including dismantling existing one all as specified and as directed, sf drop out fuse unit explusion type for out door air break gang operated switch single pole mounted on and including insulators for 11 kv working pressure fixed to and including ms channel with nuts bolts and washer etc synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity upto 400 amps all as directed including taking down old one all as specified and as directed, ml for replacement of earthing of polessystem with galvanised earth plate 60x60 cm x 6 mm thick electrode of size and 32 x 6mm gi strip buried vertically in ground not less than 225 mtr below ground level with top edge of the plate not less than 15 mtr below ground level and connected to copper strip dia by means of nuts bolts and washers and encased in and including 15 dia gi medium grade pipe upt 24 mtr height from ground level fixed by ms flat iron clamp 40mm x 5mm with nut bolt and washers gi strip fixed to base along pole and connected to over head line for providing earthing to ht polefeeder ab switch la complete with charcoal dust salt packed around plate 150 mm thick including watering gi pipe medium grade 40 mm dia with blanking cap 15 mtr long fixed to funnel with wire mesh complete with pcc chamber and rcc chamber over all as per electrical plate no 3 of ssr part i - 2009 incl excavation and earth work in any type of strata and testing on compeltion note any length of gi strip and 15 mm dia gi medium grade pipe shall be provided as per actual requirement at site, supply install in replacement of gi strip 32 mm x 6 mm buried groundfloorsurfaceroof including taking doown existing gi strip complete all as specified and directed, supply fix in replacement of complete with saddles and epoxy insulator for fitting the stripincluding taking down existing al strip complete all as specified and directednote rate included with insulater, supply and spreading stone aggregate of size 20 mm at 11 kv substations near dp structures electrical outdoor installation yard after through cleaning anti grass treatment etc all as per pecified and as directed, supply and fix in replacement of basic numerical relay wide range with facility over current phase fault short circuit earth fault instantaneous with connected accessories complete all as specified and directed make cgl tashida, supply and fix in replacement of ingress protection relay wide range 4bi 6bo iec 103modbus on rs 485 port non draw out 24-250 vdcac universal voltage ct secondary 1a 5 a universal wide range complete all as specified and directed, labour only for disconnecting repairing servicing of existing ht 11 kv33 kv vcbssf6 breakers of any make from housing and cleaning rubbing and overhauling the mechanical parts and servicing of 11 kv indoor vcb upto 800 amp checking of quality of vaccum interrupter insulation resistances static contact resistance testing ir value ratio test polarity test and connection verification of 11 kv current transformer set of three by primary injection kit and testing and calibration of relay set of two over current and one earth fault by secondary injection kit including all other functional tests of vcb cr panel and cts pts auxilary relay complete all as directed note i rate included also for complete bus bar cleaniong and tightning checking of bus bar insulation test ir test with heat shrinkasble bus bar slive ir test crm test for busbar and breaker including testing of breaker ir testing closing and opening time test coil ressitrance test motor resistance test and submit the all final test reports checking and replacement of rusted ht hardware nut and bolts ii contractor shall make his own arrangement of testing equipments and electric supply so required a detailed test report should be submitted to engr-in-charge iii all test shall be carried out by authorised company service dealer with company othorised certificate of individual iv service charges of service engineer for attending servicingoverhauling of 11 kv vcb included in quoted rates, labour only for testing of power transformer routine regular at site 3311 kv 315 mva including removing of both side cable and refixing the same after carrying out folling test ir test ratoi test magnetic core balance test open circuit test vector group test short circuit test no load test winding resistence test complete note test report mandatory for all test and shall be submitted to engr in charge is resposibility of contractor ii external eletric supply and transport required for all above test is supplyed by contractor at his own arregement rate included in quoted rate, supply and fix in replacement of dc power pack input 230 volt ac and output 30 volt dc spd base continous load 100 va impulse load 450 volt for 240 ms backup 20 minutes complete all as specified and directred make gogate elerosystem allen electricals and equivalent, supply and fixing cttb current transformer terminal block 2 5 sqmm including control wiring 25 sqmm suitable for 11 kv vcb complete all, supply and fixing in replacement of pt fuses suitable for 11 kv rating 315 amps complete all as specified and directed, supply and fixing hooter suitable for control relay panel of range 18 -90 volt acdc complete all as specified and directed, supply and fixing in replacement of breaker control switch four position suitable for 15 amps complete all as specified and directed, suply and fixing in replacement of space heater 10080 watt for vcbs 11 kv complete all as specified and directed, s f in replacemennt for resin cast type twin secondary current transformer of ratio 100-505-5a core 115 vaclass 05 and core 2 15 vaclass 03 p10 stc 263 ka1 sec for protection and metering conforming to is 2705 of 1992 complete all as directed, supply and fixing in replacement of toughend arylic transparent door glass with gas kit of suitable size existing size 5 mm, supply and fix in replacement of auxilary contactor 2 no 2 nc with add on 30 volt dc 20-25 amps make l 7 t abb siemens, supply and fixing in replacement of trippingclosing coil 11kv 30 volt dc complete all as specified and directed make cromptonkirloskar, supply and fixing in replacement of trippingclosing coil 33kv 30 volt dc make cromptonkirloskar, supply and fixing in replacement of fuse base with carrier 20 amp make cg, supply and fixing in replacement of 32 pin plug and socket for cg breakercomplete all as specified and directed, supply and fixing in replacement of tripping half shaft for 11 kv cg vcb complete all as specified and directed, supply and fixing in replacement of closing half shaft for 11 kv cg vcb complete all as specified and directed, supply and fixing in replacemnt of master trip relay 30 volt dc cgl complete all as specified and directed, supply and fixing in replacement of big gear assembly for 11 kv vcb make - cgkirloskar, supply and fixing in replacement of small gear assembly for 11 kv vcb make- cgkirloskar, supply and fix in replacement of warm wheel for 11 kv vcb full teeth compmete all as specified and directed make cg, supply and fix in replacement of motor cut off limit switch suitable for 11 kv vcb complete all as specified asnd directed, supply and fixing in replacement of micro switch assembly for vcb 11 kv make -kirlosker cg, supply and fix in replacement of anti pumpiung device relay for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of timer for motor protection range 0-25 amps for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of trip circuit healthy push butten with normally open contact for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of announaciator for sf6 control and relay panel upto 12 window voltage range 18-90 volt complete all as specified and directed, m l for replacement of sf6 copper armed cable 10 core 25 sqmm complete all as specified and directed, ml for gas charging for breaker by using sf 6 gas including checking sf6 gas pipe line pole leakage and reparing and reffiling of gas complete all as specified, supply and fix in repair of ratchet wheel assembly for sf6 breaker 33 kv, supply and fix repair povel set assembly make as per existing site for sf6 breaker, supply and fix in repair closing latch aseembly, supply and fix in repair of complete set oring assembly, supply and fix in repair of crank lever assembly, supply and fix in repair of avr relay for rtcc panel 110v ac, supply and fix in repair of tap position indicator meter for rtcc panel complte all as specified, supply fix and testing of rtcc panel including rewiring relay setting testing calibration and reconditioning complete all as specified and directed, labour only for dehydration filtration and cleaning of transformer oil of 33 kv 11kv power transformer distribution transformer ht switchgear till achievement of die-electric-strength of strength should be not less than 40 kv for new insulating oil and 45 kv for existing oil at 25mm gap all as specified and directed note i toping of transformer oil shall be measured and paid separately ii transportation of filtration vehical and required vehical mounted dg set for power supply during the filtration of transformer is responsibility of contractor and rate included in quaited rates, supply only new insulating oil conforming to is 335 for power transformermocb etc all as specified and directed note transfor oil shall be supply only in seailed barrel, decanning the power transformer oil from leaking transformer by opening the stop valvechecking for leakages arresting the leakages replacing cork sheet gasket 5 mm thick bushing washer hvlv road tapchanger gasket reassembling the transformer completely at nearest authorized workshope refilling transformer oil connecting ht lt connection complete and back install at sub station 3311 solapur new klp all as directed note i spares required shall be measured and paid separately under relevant ii topping of transformer oil will be measured and paid separately iii the rate quoted includes hvlv rod gasket cork sheet washers tap changer gaskit etc iv the rates also includes charging with and without load v the rates includes transportation of transformer to workshop and after repairing installed back at site complete all as directed by engr-in-charge vi re-insulation heating of lvhv coil included in rate quoted, ml for existing 33 kv 800a god set horizontal operation by replacing all stationary and moving contacts for all the three phases rutsed nuts bolts all as specified and directed, ml for repair and servicing testing and recommissioning series reactor by replacing gasket set insulating oil etc including painting by using two coats of synthtic enemel paints all as specified and directed, m l for taking down carefully transformer of capacity 315 mva any make any type from pole plinth base disconnecting hvlv side connections earthing strip of transformer supporting angles cross arm shifting transporting transformer carefully from the site to the workshop minimum 30 kms from site opening the top cover of the transformer bushing removing the tap changer conservator breather assembly draining of oil from the transformer lifting the core complete taking out defective coils from the core cleaning the tank and reassembling the transformer after carrying out the repairsreplacement of worn out part ovening the complete unit till to get desired megger value complete spray painting transporting returning back to the site installing re-commissioning and testing of the transformer at its original place as per is 2026 connecting up hv lv sides earthings supports cross arms etc all as directed by eic i repair of damaged transformer is including of quoted rate ii lv coil reinsulation -543 kg is including of quoted rate iii hv coil re insulation - 640 kg is including of quoted rate iv painting of transformer testing as per is 2026 is including of quoted rate note i spares rewinding of transformer if will be measured and paid separately under respective items, ml rewinding of oldburnt out 33 kv power transformer lv coils with super enamelled copper winding wire dpc cu of appropriate size of superior quality including insulating material varnishing heating coil in position copper bus bar and charging completely all as directed in engr-in-charge, supply and fix in repalacement of insulation material complete all as specified and directed, supply filling new transformer oil conforming to is 335 for transformer etc all as specified and directed, supply and fix in replacement of hv terminal rod complete all as specified and directed, supply and fix in replacement of hv bushing cap complete all as specified and directed, supply and fix in replacement of breather complete all as specified and directed, supply and fix in replacement of hardware tank nuts bolts complete all as specified and directed, supply and fix in replacement of oil level indicator glass complete all as specified and directed, supply and fix in replacement of explosion vent diapraghm complete all as specified and directed, supply and fix in replacement of core bolt insulation complete all as specified and directed, supply and fix in replacement of bushing member complete all as specified and directed, m l for servicing testing of oltc including opening top and bottom plate removing of oil and refilling of oil and checking of all taps removing of unsv parts and replace it complete all as specified and directed note spare parts and oil measured and paid separetly, supply and fix in replacement of resistance moving contact assembly for oltc complete all as specified and directed, supply and fix in replacement of main moving contact assembly for oltc complete all as specified and directed, supply and fix in replacement of contact for oltc complete all as specified and directed, supply and fix in replacement of transister register assembly for oltc complete all as specified and directed, supply and fix in replacement of local remote switch for oltc complete all as specified and directed, supply and fix in replacement of electrical counter for oltc complete all as specified and directed, supply and fix in replacement of directional selector switch oltc complete all as specified and directed, supply and fix in replacement of oil sealed for oltc complete all as specified and directed, supply and fix in replacement of top let gasket bottom let gasket assembly for oltc complete all as specified and directed, supply and fix in repair auto manual selector switch for oltc complete all as specified and directed, supply and fix in repair on 0ff switch for oltc complete all as specified and directed, supply and fix in repair lowerraiseack push butten for oltc complete all as specified and directed, supply and fix in repair tap changer alarm hooter complete all as specified and directed, supply and fix in repair mechanism stuck alarm hooter for oltc complete all as specified and directed, supply and fix in repair tap counter for oltc complete all as specified and directed, supply and fix in repair tap position indicator for oltc complete all as specified and directed, supply and fix in repair starter three phase 4-10 amps complete all as specified and directed, supply and fix in repair spring charging motor gear box assembly 230 vac for vcb 11 kv make - cromptonabbsiemens, supply and fix in repair control fuse links ns type 2a 4a 6a 10a 16a complete all as specified, supply and fix in repair only bus bar support insulator complete all a specified and directed, sf in repair of dropout do fuse expulsion for outdoor single pole mounted on and including 33000v insulator - 02 nos and ms channel with nuts bolts and washer of capacity 100amp all as specified and directed, sf in repair of lightning arrestor station class metal oxide 33 kv class iii iec long duration current impulse rating with pressure relief high suitable for 33 kv including reconnecting in 33 kv distribution circuit and testing all as specified and directed, supply and fixing in repair marshaling box with terminal box including tb terminal for ctpt connection for 33 kv vcb including complete wiring and testing complete all as specified and directed, supply and fix in repair 33 kv sf6 outdoor breaker tr-02 closing linkage assembly complete all as specified and directed, supply and fix in repair mcb dp 10 amps 10 ka complete all as specified and directed, ml for painting to 33 kv substation outer fencing and 11 kv substation fencing of structure complete including channel beams angle bracket supports clamps by using two coats of aluminium paint after scrapping out existing worn out paint including square wire mesh all as specified and directed, s f in replacement sign boards for mes installations of size 1200x 900mm made out with angle iron 40x40x 6mm as framing covered one side with 2 mm thick aluminium sheet rivetting on frame covered with retro reflective sheet 100mm high letters as directed th sign board to be fixed on 2 no 40x40x6mm angle iron legs of upto 2 mtr long embedded in pcc 148 using 40mm graded stone aggregate including of necesary excavation complete at the installation etc complete all as specified and directed by engr-in-charge note informationmatter on sign board shall be supplied by engr in charge, m l for painting of vcb panel consist 6 nos of panel in one job outerside with power coating spray painting with instant dry type paint rl 7032 including covering panel assessories like amp meter volt meter relay selector switch etc with masking tape and removing after paint complete all as specified and directed, m l for painting with epoxy paint for vcb breaker insulator complete all as specified, supply and fixing in repair relay fixing plate including cutting drlling fixing etc plate size 200 x 200 mm with power coating rl 7032 complete all as specified and directed, supply and fixing in repair residual voltage transformer voltage ratio - 11kvv3110kvv3190 volt 3 phase 50 hz complete set insulation level - l1 75 ac 2812 cont 19 for 30 sec burden - 50 va sec 50 va ter class - 13 p make harshanil eletric pvt ltd and equivalent as approved by ge, supply and fixing in replacement including testing of power factor capacitor set of 3 outdoor box type fixed on channel 11 kv of following specification capacitor unit pmpo 3 phase rated kvar 70 rated kv 67 50 hz for each rated current 1045 amps temp catagory 50 degree centigrade insulation level - 2875 discharge time - 600 second make madhav capacitors pvt ltd and equivalent as approved by ge, m l for shifting of transformer of any capacity from two pole fore pole structure with crane including dismantling existing connection of transfomer and shifting it on plinth within 100 mtr distance and reconection of transformer after shifting on the plinth with necessary connection and testing for serviceable complete without any damage all as specified and directed by engr in charge note any type of damageleakage of tranformer oil during the shiftingtransportation shall be repaired by contractor at his own cost without any claim, m l for transformer plinth of size 2000mm x 2000 mm x 1500 mm including excavation in trenchs in any type of soil pcc 14 8 in foundation fly ash bricks machinaryin cement mortor1 6 filling with moorum inside the plinth and rcc 124 over plinth including 16 mm bar reinforcement with center to centre distane 100mm and external surface of masonry shall be plastered with cement morter 14 and painted with weather coat paint double coat paint of shade complete all as specified and directed by engr in charge, supply and fixing in replacement of synthetic insulating rubber mat tested for ht 1122 kv with test certificate for installation of size 2m x1m x22 mm etc complete all as specified and directed by engineer-in-charge, supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation returning and removing complete all as specified and directed, ml providing pre cast rcc 113 type a1 using 20 mm graded stone aggregates as in cable route indicator of height 800 mm x width 300 mm x thickness 120 mm duly reinforced all as per details shown in drawing and having top circular section provided with and including pcc 148 type d2 using 40 mm graded stone aggregates foundation of suitable size as directed and including engraving letters mes 11 kv ht on route indicator duly painted in synthetic enamel dark brown colour paint complete all as specified and directed, supply and fixing in replacement of indicating lamp with universal voltage with color coding red yellow blue amber white green all as specified and directed, supply fixing in replacement of digital volt meter single phase all as specified and directed make lt seimens, supply fixing in replacement of digital ammeter meter 1133 kv control supply 230v ac all as specified and directed make lt seimens, s f replacement of ht bushing porcelain vitreous brown body suitable for power transformer as per is 3347 all as specified and directed, m l for replacement of breather assembly including silica gel complete suitable for power transformer existing at site complete all as specified and directed, supply and fix ht 33 kv out door type gang operated air-break switch suitable for horizontal mounting fixed type complete with 9 insulators 33 kv and with earth switch upto 200400 amps with all fittings and accessories mounted on and steel channel frame gi operating rod 25 mm dia of suitable length to worked from ground including locking arrangements suitable for 33000 volts 400 amps current rating complete including dismantling existing one all as specified and as directed, material and labour for copper earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick buried vertically in ground each pit not less than 225 mtrs deep below normal ground level with top edge of plate not less than 150 m below normal ground level connected to copper strip 20 x 3 mm by means of bolts nuts and check nuts and washers etc encased in gi protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extent of 75 meters all as shown on electrical plate no 3 of mes ssr - 2004 part - i gi protection pipe buried in ground laid under floors plinths or mixed on walls pole etc or concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate including pcc 124 type b-1 earth pit with ms angle iron frame cast iron cover with locking arrangement with gi 20 mm dia medium grade pipe and ms funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil strata and testing on completion complete all as specified and directed note- i cost of copper strip 20 x 3 mm and protection pipe 40 mm dia is deemed to be included in rate quoted ii excavation and returning filling of soil any type is deemed to be included in rates, material and labour for chemical earthing complete with copper earth plate electrode 900 x 600 x 5 mm thick buried vertically in ground each pit not less than 225 mtrs deep below normal ground level with top edge of plate not less than 150 m below normal ground level connected to copper strip 32 x 6 mm by means of bolts nuts and check nuts and washers etc encased in gi protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extent of 75 meters all as shown on electrical plate no 3 of mes ssr - 2004 part - i gi protection pipe buried in ground laid under floors plinths or mixed on walls pole etc or concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate including pcc 124 type b-1 earth pit with ms angle iron frame cast iron cover with locking arrangement with gi 20 mm dia medium grade pipe and ms funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil strata and testing on completion complete all as specified and directed note- i cost of copper strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii excavation and returning filling of soil any type is deemed to be included in rates, m l for replacement of sf6 copper armed cable 12 core 25 sqmm complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
surface excavation nexc 30 cm deep and averaging 15 cm in deep and getting out in any type of soil complete all as specified and as directed, removal of surplus soil to a distance of 250m and not exceeding 500m and depositing complete all as specified and as directed, excavating over areas n exc 15 m deep and getting out in softloose soil complete all as specified and as directed, ml for plain cement concrete 148 type d2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed, returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed, removing excavated soil exc 250 m but n exc 500 m and depositing where directed at a level n exc 15 m above the starting point complete all as specified and as directed, moorumred bajri filling in floors or pavings laid in layers n exc 15 cm thick spread levelled and rammed including watering complete all as specified and as directed, ml for hard core of broken stone or boulders of gauge nexc63mm deposited spread levelled in layers nexc15cm thickness watered and rammed to a true surface complete all as specified and as directed, ml for damp proof course to horizontal or vertical surface including necessary form work 40 mm thick in cement concrete 124 type b-0 using 125 mm graded stone aggregate complete all as specified and as directed, m l for brickwork with subclass b bricks straight or curved on plan exc 6m mean radius with built in cm 16 complete all as specified and as directed, ml for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 14 complete all as specified and as directed, ml rendering 15mm thick on fair face of brick walls or concrete surfaces in cm 16 finished even and smooth without using extra cement complete all as specified and as directed, ml for new plastered surfaces of walls and applying two coats of distemper oil emulsion over a one coat of primer and 3 mm wall putty complete all as specified and directed, ml for preparing newly plastered surfaces of walls and applying two coats of cement based paint complete all as specified and as directed, use and waste of form work to sides of foundationfootings plinth beams and similar work for rough finished surfaces complete all as specified and as directed, use and waste of form work to sides of columns and pillars for for fair finished surfaces complete all as specified and as directed, formwork to sides and soffits of floor or roof beams beam haunchings girders bressummers lintels cantilevers shelves including supports overhangs etc also splays between floors and beams etc complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in footings plinth beams and the like complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in columns and pillars complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in lintel beams roof beams lintle beams and the like complete all as specified and as directed, mild steel bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 09mm dia or securing with clips complete all as specified and as directed, mild steel bars 5mm dia and over upto and including 10mm dia in stirrups spacers and binders cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 09mm dia or securing with clips complete all as specified and as directed, roof trusses framed trussed purlins crane gantries rails and fastenings and heavy bracket framing beam tee angle channel or flat sections including distance pieces cleats etc cleats etc of ge 410 gde-e-250 quality-a complete all as specified and as directed, plates plain or chequered channels square cut or notched ordinary and counter sunk forming holes without any attachment of ge 410 gde-e-250 quality-a complete all as specified and as directed, sf aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 550mm thick tinted glass fixed with rubber gasket with aluminium heading clips frame made with aluminium box sec as appended below complete all as specified and directed including aluminium wire mess shutter a frame 100x44x148mm thick with rawl plug b middle and lock rail 150x44x148mm thick c bottom rail 100x44x148mm thick d top railstyle 100x44x148mm thick e aluminium beading 07mm thick f aluminium handle d type 150mm long nos-02 aluminium tower bolt-02 99mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper hydraulically regulated designationed no-3 universal type of wt btn 61 to 80 kg-01 g making good of wall surface to match with existing surface complete, sf powder coated aluminium sliding windows frame with movable shutter sliding on minimum two pvc roller of best quality for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and incl 550 mm thick glass stainless steel wire messs fixed with neoprene rubber gasket with aluminium beading clips frame made with aluminium section as appended below- i window frame 63x35mm x 148 mm thick for two tracks ii topbottom rail and style rail of shutter 19x38x148mm thick and over iii aluminium beading - 07mm thick iv stainless steel wire cloth 045mm nominal dia of wire and average width of aperature 140mm and fixed in aluminium window or alongwith fy section fixed with aluminium wire staples complete v aluminium fittings such aluminium suitable handle with auto interlocking closing vi making good of wall surfaces to match with existing surfaces complete all as specified and as directed, ml prepainted galvalume aluminum zinc coating gi based corrugated steel sheet 050mm thick of any colour having tensile strength of 550 mpa as in roof coveringcladding to wall fixed with self tapping screws complete all as specified and as directed, ml prepainted galvalume aluminum zinc coating gi based plain steel sheet 050mm thick of any colour having tensile strength of 550 mpa as in roof coveringcladding to wall fixed with self tapping screws complete all as specified and as directed, ml preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed, m l for 100 mm thick cement concrete type c- 2 136 20mm graded aggregate in plinth protection and finishing surfaces of concrete in sub-floors sub-bases path etcfinished even and smooth without using extra cement complete all as specified and as directed, ml rubber moulded interlocking paver block any shape and size confirming to is 15658 -2006 of 80mm thickness m-40 grade with grey cement and no pigment complete all as specified and as directed, excavation over area n exc 15 m deep and getting out in harddense soil complete all as specified and as directed, ml for pcc 148 type d2 using 40 mm graded stone aggregate as in mass concrete complete all as specified and as directed, m l for walling of random rubble uncoursed well bonded bedded and solidly hearted built in cm 16 complete all as specified and as directed, extra over stone walling for hammer dressing to face stone and dressing of face beds and joints complete all as specified and as directed, m l pcc 124 type b - 1 20 mm graded aggregate cast in situ as in coping incl weathering slightly rounded and champhered angles and throating all as directed, ml for precast cement concrete 136 type c1 using 20 mm graded crushed stone aggregate as in bond stones complete all as specified and as directed, m l flush pointing to random rubble stone masonry in cm 14 uncoursed or brought upto courses complete all as specified and as directed, sf of 110 mm bore pvc swr pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed, removing excavated material n exc 50 m and depositing where directed at a level not exceeding 15m above the starting point complete all as specified and as directed, hand packing any thickness at back of walls over arches etc and raising or lowering to the required level complete all as specified and as directed, a one light pointfan pointex fan point controlled by one 5 amps switch one way, b one 3 pin 5 amp switch socket outlet on independent board, c one 3 pin 5 amp switch socket outlet on same board with accessories, ml for point wiring using proper colour coding complete with 1100 volts grade 25 sqmm single core pvc insulated unsheathed cable with multistranded copper conductor with isi mark frls grade conforming to is-694 in and including pvc medium grade conduitcasing caping not less than 25mm dia isi marked with all accessories concealed in wallceiling floor roof etc with sunk pressed steelgi terminals boxes having 16 mm thick suitable for housing of modular type switchessocketsfan regulators including 25 sqmm pvc insulated unsheathed multistranded copper conductor frls 1100 volts grade green colour as earth wire connected to common earth dolly for switch socket combination 3 pin 15 amps on independent board all as specified and directed, sf switch piano flush type single pole one way 6 amp 240 volts complete all as specified and as directed, sf switch piano flush type single pole 15 amp 240 volts complete all as specified and as directed, sf socket outlet 2 in 1 3 pin 5 amps flush type complete with gang box complete all as specified and as directed, sf socket outlet 2 in 1 3 pin 5 and 15 amps flush type complete with gang box complete all as specified and as directed, supply and fix ceiling rose 3 terminal pvc polycarbonate isolated body complete all as specified and as directed, sf in repairs distribution board spn 8 way double door complete all as specified and as directed, s f in repairs mcb dp 40 amps 240 volts b curve complete all as specified and as directed, s f mcb single pole 6-32a amps 240 volts b curve complete all as specified and as directed, supply and fixing led lights fitting 1x 20w 220v ac decorative box type with driver holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed, ml for supplying and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor served with inner sheathing of pvc tape and overall pvc sheathed in sevice connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire with two single core cables flat or circular 16 sqmm 2 core complete all as specified and as directed, supply and fix building security light led fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with- 25 nos ip 6566 protection complete all as specified and as directed, ml for earthing complete with galvanised steel earth plate electrode 6060cmx 6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not lessthan 15 metres below normal ground level connected to galvanised earth lead wire 40mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed, supply installation testing commissioning of 44 wall mounted gas manifold with nrv copper tail fabricated with high pressure copper of size 58 x 10swg and with is319 brass nrv hydraulic tested at 300 bar degreased copper tail pipe of size 58 x 16 swg hydraulic tested at 300 bar fitted on ms frame middle frame with chain for oxygen without cylinders complete all as specified and as directed hsn code-995415 make - mr, supply installation and commissioning of semi-automatic control panel p c with inbuilt audio visual alarm non return valves for oxygen with copper tubing for connecting manifold to control panel for both sides left bank right bank complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of 1 cylinder emergency wall mounted gas manifold with nrv copper tail fabricated with high pressure copper of size 58 x 10swg and with is319 brass nrv hydraulic tested at 300 bar degreased copper tail pipe of size 58 x 16 swg hydraulic tested at 300 bar fitted on ms frame middle frame with chain for oxygen and with single stage double gauge mox regulator -indian without cylinders complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of british standard nemo safe gas outlets with stainless steel probe oxygencomplete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of metal body bpc flow meter with humidifier bottle 0- 15 litres adult complete all as specified hsn code-995415 make - mr, supply and fix conversion kit with 5 mtr high pressure tubing antistatic for oxygen complete all as specified and as directed, supply installation testing commissioning of vacuum pump simplex with500ltr reservoir tank electrical motor 3phase base frame vacuum pump 5 hp 1 nos make aw ir vacuum receiver tank 500 ltr capacity 1 nos bacterial filter silencer brass fitting complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of british standard nemo safe gas outlets with stainless steel probe vacuum complete all as specified and as directed hsn code-995415 make - mr, supply and fix ward vacuum unit with regulator collection jar of 600 ml with bracket complete all as specified and as directed hsn code-995415 make - mr, supply and fix low pressure tubing - vacuum complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of medical grade bs en 13348 lloyd tested copper pipe indian copper pipe 12 mm od x 07 mm thick complete all as specified and as directed hsn code-995415 make - mexflowrajcommandev, all as per item no 69 above copper pipe 15 mm od x 09 mm thick complete all as specified and as directed, all as per item no 69 abovecopper pipe 22 mm od x 09 mm thick complete all as specified and as directed, all as per item no 69 abovecopper copper pipe 28 mm od x 09 mm thick complete all as specified and as directed, supply installation testing commissioning of line isolation ball valve - indian with both side end fittings 15mm 22mm complete all as specified and as directed hsn code-995415 make - rnrb, all as per item no 73 above copper 22mm complete all as specified and as directed, supply installation testing commissioning of microprocessor based line pressure alarm- digital type for 2 gas service oxygen vacuum complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of horizontal bed head panel envirom 4 feet long mr-bhp-01 with powder coating and with the following provision gas outlet points 2 nos provision electrical switches socket - 4 nos each not in our scope ward vacuum unit slider stainless steel railing 2 feet long complete all as specified and as directed hsn code-995415 make - mr
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid