customised head neck surgery pack sterile, customized disposable impervious absorbent adhesive drape set for thoracotomy or laparotomy, disposable sterile surgical impervious gown reinforced with aami level 4 high fluid protection abrasion resistance with level 4 liquid barrier standards en13795 us fda approved sfs integrated film microcool breathable fabrics sterile surgical gown
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
establishment of chemotherapy ward at cantonment general hospital including supply installation testing and commissioning of various medical equipments and allied infrastructure with 05 years warranty
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
dehydration of tranformer oil obtained from transformersvoltage stabilizer etc dielectric strength shall not be less than 50 kv in 25 mm gap electrode after dehydration dehydration of transformer shall be carried out by using electrically operated dehydration machine complete all as specified and as directed note- i centrifuging machine with all tp testing machine of oil required for dehydration shall be arranged by the contractor ii oil required for topping up the transformer will be measured paid separately, supply only ehv transformer oil as per is 335 of 1983 is 1866-2000 for topping up of transformer oil in existing position having dielectric strength not less than 50 kv in 25 mm gap electrode complete all as specified and as directed make -power oilsavitaservo, supply fix and testing in repair wti with 3 mtr capillary lengths as per sample complete all as specified and as directed, supply fix and testing in repair oti with 3 mtr capillary lengths as per complete all as specified and as directed, s f in repair breather assembly for transformer of capacity 5 mva complete all as specified and as directed, supply only silica gel of superior quality of 5 to 10 mm grade complete all as specified and as directed, ml for surface dressing averaging 15 cm depth in softloose soil for cleaning and cuttingremoval of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grassbushes complete all as specified and as directed, material and labour for preparation of old rusted steel surfaces of ht swaged poles of 11m length and applying one coat of synthetic enamel paint up to 12 meter height as per the existing pattern above the pcc coping and one coat of aluminium paint beyond 12 meter height for the rest portion including cross arms brackets and re-writing pole numbers and cutting vegetation growth all around and on the poles up to 1 metre radius complete including replacement of self adhesive fluorescent colour tape as per existing pattern and size complete all as specified and as directed, ditto all as per item no 08 above but ht 4-pole structure complete all as specified and as directed, ditto all as per item no 08 above but ht 2-pole structure complete all as specified and as directed, s f steel tubular swaged pole with cast iron base plate finial tapper plug bolts nuts and screws type 410 sp-55 1100 m long including two coats of aluminium paints over one coat of red oxide primer on external exposed surfaces and two coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole as in repairs complete all as specified and as directed, excavation in trenches not exceeding 15 m in deep not exceeding 15 m wide and getting out in soft loose soil including leveling and ramming complete all as specified and as directed, excavation in trenches not exceeding 15 m in deep not exceeding 3 m wide and getting out in soft loose soil including leveling and ramming complete all as specified and as directed, returning refilling in trenches exvcavated soils including spreading leveling well ramming in layers not exceeding 25 cm thick complete all as specified and as directed, removal of excavated surplus soil to a distance nexceeding 50 m and depositing where directed at a level not exceeding 15 metre above the starting point complete all as specified and as directed, m l pcc 136 type c2 using 40 mm graded crushed stone aggregates as in foundation of poles filling and mass concrete complete all as specified and as directed, m l pcc 124 type b2 using 40 mm graded crushed stone aggregates as in coping of poles filling and mass concrete complete all as specified and as directed, ml clean dry river sand in trenches ducts for cushioning to cable 8 cm below the cable and 15 cm above the cable and measured only 18cm thick sand paid complete all as specified and as directed, supplying laying jointing testing 185 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 33000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 185 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 120 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supplying laying jointing testing 95 sqmm x 3 core xlpe insulated pvc sheathed armoured ht cable 11000 volts grade heavy duty with aluminium conductor laid in trenchespipefixed on the wall etc complete all as specified and as directed, supply and laying un-reinforced precast concrete cable class hv type -i flat size 300mm x180mmx40mm complete all as specified and as directed, m l for road cutting including excavation in trenches for laying ht ug cable in pipe not exc 45 cm wide and nexc 60 cm depth or as per site requirement for laying of gi pipe making good the disturbed surfaces with cement concrete 136 type c-1 and top surface neatly finished as per existing to match with the existing complete all as specified note - gi pipe light grade will be paid and measured under separate item the cut excavated surface will be repaired on same day with pcc failing which a penality of rs 500 per day will be recovered from contractor dues, sf steel tubes light grade galvanised with all fitting laid in trenches fixed to wall and floor of 150 mm dia bore for cable protection complete all as specified and as directed, sf steel tubes light grade galvanised with all fitting laid in trenches fixed to wall and floor of 100mm dia bore for cable protection complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 120 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 11kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 120 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination indoor type cable jointing kit for 11kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f heat shrink end termination outdoor type cable jointing kit for 33 kv ht xlpe cable of size 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 33 kv ht xlpe cable of size 120 sqmm to 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 11 kv ht xlpe cable of size 120 sqmm to 185 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, s f in repair heat shrink straight through type cable jointing kit for 11 kv ht xlpe cable of size 95 sqmm 3 core complete with jointing material and accessories complete all as specified and as directed, ml in repair earthing complete with galvanised steel earth plate 600x600x6mm thick buried directly in ground earth pit not less than 40 mtr deep below ground level with top edge of the plate not less than 325meters below normal ground level connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts nuts check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work gi pipe light grade 40 mm bore for protection of gi strip from earth electrode to and including the earth test point of galvanised ironsteel of size 75x75x 25mm supplying and laying charcoal dust common salt pcc 124 type b1 chamber and ms angle iron frame 40x40x6 cm and rcc cover 40mm thick 124 type b1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars 75mm cc both ways with ms handle 12mm dia pgi funnel and wire mesh 20 mm dia gi pipe light grade for watering all as shown in drawing and connected to earth test point including testing complete all as specified and as directed, material and labour for repairreplacement of earth pit including using pcc 136 type c-1 precast rcc 1153 type a-1 cover slab of size 40x40x 6 cm reinforced with 8mm dia tmt bars 150mm cc both ways with one handle for lifting made out of 8mm dia ms bar embeded in precast cover slab including necessary excavation and earth work in any type of soil complete all as specified and as directed, ml for pin type porcelain white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one one galvanised iron nut suitable for 33 kv grade complete all as specified and as directed, ml for disc type string of 3 disc insulator porcelain white brown or green insulator suitable for 33 kv grade complete all as specified and as directed, sf in repair pin type insulator polymer with hardware fittings grey brown or green suitable for 11000 volts grade complete all as specified and as directed, sf in repair disc type insulator polymer with hardware fittings grey brown or green suitable for 11000 volts grade complete all as specified and as directed, ml cross arms bracing supports clamps and back plates fabricated from structual steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all as specified and as directed, supply and fixing in repair new aluminium conductor steel reinforced acsr of any sizetype stringing and jointing on poles including providing binding wire etc complete all as specified and as directed, supply an fixing danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with msclamps bolts and nuts of approved size for 33 kv ht 25x20cm size complete all as specified and as directed, supply an fixing danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with msclamps bolts and nuts of approved size for 11 kv ht 25x20cm size complete all as specified and as directed, supply and fix in replacement d o drop out fuse unit double stack channel type 3 pole 33 kv channel mounted complete all as specified and as directed, supply and fix in repair polymer type air break switch gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 amps and working pressure 11000 volts with drop out type fuses set 12 insulators three numbers of 400 amp capacity complete including dismentling air break gang operated switches verticalhorizontal mounted including insulator hand operating mechanism for replacement of brokenworn out components and insulators etc all as specified and directed, supply and fixing in repair triple pole double break central rotating banging type isolator horizontal mounting current rating up to 600 amps for 33 kv including post insulators accessories as per existing complete all as specified and as directed, ml for removing and taking out old stone aggreated any size clear all surface their after laying single layer of sand dust in 33 kv mrs yard 11 kv distribution sub station and before laying stone aggregate complete yard including spreading of anti vegetation chemical to prevent abnormal growth of grassbushes complete all as specified and as directed, ml for spreading and levelling evenly 40 mm graded stone aggregated at 33kv main receiving station 11 kv sub station complete all as specified and as directed, material and labour for laying trench cover on cable trenches as per existing at 33 kv11 kv mrs ward made out of rcc 124 type b0 125mm graded stone aggregate, ml lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 11000 volt complete all as specified and as directed, ml lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 33000 volt complete all as specified and as directed, material labour in repair of polymer lighting arrester high tension expluive type complete with all fitting transmission class diescharge capacity 65 kilo amp suitable for 11000 volts complete all as specified and as directed, supply fix testing current transformer ct of 33 kv single phase out door oil cooled ct ratio 100505 amps dual core - one for metering and other for protection having 16 va burdon and class 5p-10 protection and 05 metering complete all as specified and as directed, supply fix testing potential transformer pt of 33 kv single phase outdoor oil cooled pt ratio 33000v3110v3v class 10 having 100 va burdon complete all as specified and as directed, supply fix testing pt protection transformer for 11 kv indoor vcb draw out type 11 kv 11000110 v va-5 class 1 rated friquency 50 hz make- cgl approved vendor all as directed note- complete above said work will be carried out through authorised rep of cg, ml for structural ms frame work half round or other stock section including securing posts and stuts in fencing frame work for gates of substations base frame for equipments including securing bolts posts and struts in fencing including cutting and making shapes as desired drilled holes notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilled bolting or riveting etc and similar work confirming to fe-290 gde e-165 complete all as specified and as directed, sf mild steel screw boltmechine made with hexagonal or square head nexc 5cm but nexc 10 cm dia complete all as specified and as directed, ml for prepration of steel surface of one coat of red oxide and two coat of synthetic enamel paint any description n exc 10 cm in width or grith when unconnected with other painting or when painted in a different complete all as specified and as directed, attending the testing by authorised rep of oem of vcb for attending of servicing overhauling of 11 kv indoor vcb panel including breaker cgabbjyoti make at 3311 kv mrs at ge babina station and including following, supply only led indicating lamps any colour redyellowgreenblue universal voltage for vcb 11 kv of 630400 amps all as per sample complete all as specified and as directed, supply only trip circuit healthy push button with no contacts suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only spring charging motor 230vac dc suitable for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only limit switch suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only microswitch assembly suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only big gear assembly suitable for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only small gear assembly suitable for vcb 11000 volt of 630 400 amps all as per sample complete all as specified and as directed, supply only tripping shaft assembly suitable for vcb 11000 volt of 630 400 amps all as per sample and complete all as specified and as directed, supply only closing shaft assembly suitable for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only segment gear assembly suitable for vcb 11000 volt of 630 400 amps all as per sample and complete all as specified and as directed, supply only pt fuse for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only spring charging handle for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only breaker control switch 4 passion for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only ctepoxy type ratio 300-15055a core 115 vaci05 core 2 15 vacl5p10 stc 263 ka 1 sec for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only ctepoxy type ratio 100-5055a core 115 vaci05 core 2 15 vacl5p10 stc 263 ka 1 sec for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only closing coil assembly 30vdc for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only tripping coil assembly 30vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only closing coil assembly 110vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only tripping coil assembly 110vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only plug sockect for vcb 11000 volt of 630400 amps as per sample and complete all as specified and as directed, supply only 8no8nc auxiliary switch for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only space heater 10080w for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only thermostat for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only hrc control fuse 2a 4a 6a 10a for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only complete breaker mechanism assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only onoff push button plate assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only fuse base with carrier up to 32 a for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only timer for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only anti pumping device for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only relay ammeter voltmeter fixing plates with powder coating paint siemens gray rl7032 for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only door knob for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only trip catch assembly for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only set of 06 sleeve for poles for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only set of 06 isolating contacts for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only set of 03 vaccum intrruptor supporting insulators for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only tcs auxiliary relay 24vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed make- lt, supply only auxiliary switch 5 no5 nc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed make- lt, supply only closing coil 30vdc for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only lugs ferules cable teis saddle base 12 sqmm 25 sqmm for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only hooter for vcb 11000 volt of 630400 amps all as per sample complete all as specified and as directed, supply only crc spray bottle for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only epoxy paint for vcb 11000 volt of 630400 amps all as per sample and complete all as specified and as directed, supply only 15 multistrandad flexible copper cable 1100v grey colour control wiring for vcb 11000 volt complete all as specified and as directed, ml for spring charging motor modification works under vcb 11000 volt of 630400 complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, ml for modification works under vcb 11000 volt of 630400 to compatable new vcb trolly with existing vcb panel complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, ml for modification fabrication work connection of 11 kv copper bus bar of suitable size suitable lenght as per menufacturer recommendations under vcb 11000 volt of 630400 including copper busbar its jointing and cover with reycam sleeves in existing vcb panel complete all as specified and as directed note- complete modification work will be carried out through authorised rep of cg, attending the testing by authorised rep of cg for servicingoverhauling of 11 kv rmu 4 way 6way 8way of make- lucyabbmegawin at differenet location under ge babina station complete all as specified and as directed for following, attending the testing by authorised rep of cg for servicingoverhauling of 33 kv cg abb areva make outdoor sf6vcb breakers at 3311 kv mrs at ge babina station all as specified and directed for following, supply only ratchet wheel assembly for 33kv vcb 1250 amp 25 ka as per existing sample complete all as specified and as directed, supply only closing latch assembly for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only tripping latch assembly for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only set up o ring for pole for 33kv vcbsf-6 breaker 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only dc auxiliary 30v dc contactor for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only motor contactor 30v dc for 33kv vcb 1250630400 amp 263 ka as per existing sample complete all as specified and as directed, supply only limit switch for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only closing coil assembly 30 v dc for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only tripping coil assembly 30 v dc for 33kv vcb 1250 630400 amp as per existing sample complete all as specified and as directed, supply only spring charging motor 230 vacdc for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only spring charging gear assembly for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only small gear assembly for 33kv vcb 1250630400 amp as per existing sample complete all as specified and as directed, supply only anti pumping device for 33 kv vcb 1250 630400 amps all as per existing sample complete all as specified and as directed, supply only complete pole assembly 33 kv outdoor type all as per existing sample complete all as specified and as directed, supply only breaker charging complete mechanism 33 kv outdoor type all as per existing sample complete all as specified and as directed, testing of outdoor ct pt connection marshaling box with tbs channels for 33 kv vcb control connection complete all as specified and as directed, supply fixing installation and testing in repair power pack unit for battery backup 230 vac 30 vdc suitable for existing cgabb make indoor vcb panel as recommanded by oem complete all as specified and as directed, supply fixing installation and testing in repair power pack unit for battery backup 230 vac 110 vdc suitable for existing cgabb make indoor vcb panel as recommanded by oem complete all as specified and as directed, supply fixing installation and testing in repair 3 phase over current 01 earth fault relay in existing 11 kv indoor vcb panel with high set with idmt and inst characteristics having aux supply v of 20-110v dc rated volt 250 vac 30 or 110 vdc universal wide range as per site requirement complete all as specified and as directed make- cg model - cg14n or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair 3 phase over current 01 earth fault relay in existing 11 kv indoor vcb panel with high set with idmt and inst characteristics having aux supply v of 24 to 240 v acdc rated volt 250 vac 30 or 110 vdc universal wide range as per site requirement complete make- lt model - mc61a-nx cat no mc61anx4000 or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair rej601 feeder protection inrush current relay abb make in existing 33 kv and 11 kv indoor vcb panel with over current short circuit earth fault inrush current instantaneous protection features ct secondary 1 a 5a universal wide range auxiliary voltage universal acdc wide range site selectable range make- abb model rej601 or equevalent of seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair aegis a131d1 feeder protection inrush current relay cg make in existing 33 kv and 11 kv indoor vcb panel with over current short circuit earth fault inrush current instantaneous protection features ct secondary 1 a 5a universal wide range auxiliary voltage universal acdc wide range site selectable range make- cg model no aegis a131d1 or equevalent of abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair wtioti alarm relay for transfomer protection in existing 33 kv control panel as sample complete all as specified and as directed make- cg cs abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair wtioti trip relay for transfomer protection in existing 33 kv control panel as sample complete all as specified and as directed make- cg cs abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, supply fixing installation and testing in repair 86 master trip relay in existing 33 kv or 11 kv indoor vcb control panel with 30 vdc complete all as specified and as directed make- cs cg abb seimens schneider note- i all necessary arrangement for fixingaccommodate new relays in exisitng 11 kv vcb panel including cuttingcasing control wiring will be included in quoated rate ii complete fixing installation and testing work of relay will be carried out through authorised rep of cg, attending and testing by service engineer to carry out priodical on site testing of 3311kv 02 nos 5 mva 01 nos 125 mva transformer by authorised agency at 3311 kv mrs at ge babina station are as under - a ir value test b ratio test c magnetic core balance test d open circuit test e vector group test f short circuit test g no load current test note- a all necessary arrangement at the site of testing quipment for the testing will be responsibility of the contractor and rate for the same will be included in quoated rate b after the testing of transformer test report will be submitted to the department necessary recommandation suggestion also be mentioned in report if any, sf in repairreplacement voltmeter digital type with selector switch of size 96x96mm 01 phase rating complete all as specified and as directed make- elmeasure conzervelt, sf in repairreplacement voltmeter digital type with selector switch of size 96x50mm 3 phase 03 wire rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair replacement ammeter digital type with selector switch of size 96 x 96 mm 01 phase rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair repalcment ammeter digital type with selector switch of size 96 x 50 mm 3 phase 3 wire rating complete all as specified and as directed make- elmeasure conzervelt, sf in repair replacement multifunctional meter of size 96 x 96 mm rating complete all as specified and as directed make- elmeasure conzervelt, supply fixed installed and testing in repair replacement em7230 demand controller cl 10 rs485 in existing 11 kv indoor vcb panel complete all as specified and as directed make- schneiderltabb, sf in repair breaker control switch trip-neutral-close tnc with 2no 2nc spr rtn for 33 kv control panel cat part no 72009 lt, ml earth continuity conductor or main earthing lead 32 x 6 mm galvanized iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed, ml framed work as in doors or gates of angle or other section with gusset plates rails braces etc complete drilled for fixing of steel heeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete fe 410 wgde e-250 complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 12m x 2m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 12m x 3m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 15m x 3m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 15m x 4m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf in repair repalcement for led glow sign board of size 6m x 07m made out acrylic sheet 3 mm dia with acp sheet in front of it placed covered with cgi in all side 26 gauge sheet with led modular lights inside duly complete including fixed on suitable steel pole and with suitable supporting frame or fixed on wall and fixing arrangement lighting connection with suitable copper wire complete all as specified and as directed, sf retro reflective sign board made up with 12 mm thick stainless steel sheet of which both sides shall be fully covered with high intensity prismatic hip retro reflecting sheeting of approved specification asper morth having approved message matter and base fully processed by pressure sensitive equipment of approval brand avery dennison3 m fixed hanging on sub station fencing on stainless steel frame makeup of ss as described complete all as specified and as directed, material and labour for repairmaint of trolly of trolly mounted transformer including oiling greasing of moving parts checking repairing make fuctional of punture tyre of trolly and painting of complete trolly with synthetic enamel paint with existing pattern or as directed after cleaing of oily surface of trolly complete all as specified and as directed, material and labour for preparation of old rusted steel surfaces of complete 33 kv yard including ht 2 pole 4 pole structure of 11m length out door ctpt steel structure outdoor vcb steel structure islolator do fuse structure etcas per the existing pattern above the pcc coping with two coat of aluminium paint on complete steel structure and pcc coping painted by applying one coat of synthetic enamel paint complete all as specified and as directed, 12 core 25 sqmm, 6 core 25 sqmm, 4 core 25 sqmm, supply and fix in replecemnet of automatic fcbc and trickle battery charger cum tripping unit 30 vdc 165 ah for 33 kv and 11 kv protection equipment with comprising of following- electrical specification a ac input voltage 230 v range 180v to 264 v b ac input frequency normal 50 hz - 3 hz c dc output volt normal for load 30vdc d 20 amps total current output capacity battery type- a lead acidsmfvlrs b indications for mains supply float charging boost charging ac volt meter dc volt meter dc fail ac fail alarm dc amp meter for load dc amp meter for charging protection- a circuit breaker for mains incoming supply circuit breaker for output load over load protection ac short circuit protection battery reverse polarity low high volatage protection housing and enclosure- a heavy duty sheet steel enclosure finished with powder coated paint floor mounted operation a automannual control cccv close loop rectifier full wave half controlled bridge element fuse protection for rectifier element fuse failsure relay dc earth fault relay alarm annunciation dual float charger option note- i the internal control wiring of battery charger should ber carried out by susing suitable size of multistranded frls copper conductor cable with lugs ii all necessary connection battery bank to vcbs should be carried out by using suitable size of copper wire complete, s f in repair of vrla battery bank 30v 02 v x 15 nos cell 100 ah 02 v with vrla battery rack including connection with necessary suitable copper cable or bus bar strip complete all as specified and as directed make - exideamronluminous, testing of earth resistance of existing earth pit as and when required as per is 3043 1987 ssr part-i para 19146 using earth resistance testing equipments as directed and producing the test result for recording purpose complete all as specified and as directed note - 1the contractor shall be asked to carry out the earth test as completely 2 testing of each earth pit shall be measured as one unit 3all test result to be entered in a register properly bound and covered and to be submitted to the engr-in-charge during payment 4 for the purpose of testing contractor shall supply all equipments and apparatusinstruments at his own cost without any extra claim, testing of battery of existing battery bank and battery charger as and when required using testing equipments if required changing of terminals greasing of terminals and pouring of distilled water as directed and producing the test result for recording purpose complete all as specified and as directed by the engr in charge note 1the contractor shall be asked to carry out the battery test as completely 2 testing of all battery in the battery bank shall be measured as one unit 3 all test result to be entered in a register properly bound and covered and to be submitted to the engr-in-charge during payment 4 for the purpose of testing contractor shall supply all equipments and apparatusinstruments at his own cost without any extra claim, testing repairing and making functional of existing 11 kv ht capacitor bank make abb including all necessary spare parts of capacitor as required for making functional of ht capacitor bank complete all as specified and as directed note- i reparing work of ht capacitor bank will be carried out through authorised and specialised agency of similar field ii submit the test report to department before starting and after completion of repair work with functioning of ht capacitor bank and submit their recommendations if any for further improvement of the system iii 11 kv ht capacitor if required for replacement shall be measured and paid separately under respective item of schedule here in after as supply only, supply only do fuse elementwire suitable for 33 kv 5 to 100 amp, supply only do fuse elementwire suitable for 11 kv 5 to 200 amp, s f abc power portable wheeled extinguishers with class a b c and electically started fires packed with 50 and 90 map concentration state of the art pressure gauge quick powerful and reliable fire fighting system with 25 kg ms sp red make cease fire cat part no cf-001167 or equivalent to other make complete all as specified and as directed, s f abc power portable wheeled extinguishers with class a b c and electically started fires packed with 50 and 90 map concentration state of the art pressure gauge quick powerful and reliable fire fighting system with 50 kg ms sp red make cease fire cat part no cf-001167 or equivalent to other make complete all as specified and as directed, s f power portable class ceasefire multimax state of the art pressure gauge quick powerful and reliable fire fighting system with 09kg make cease fire or equivalent to other make complete all as specified and as directed, refilling of dry chemical powder extinguisher stored pressure type with change of nozzle pipe pressure gauge 09 kg complete all as specified and as directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
earthwork excavation in trenches not exceeding 15 m wide and not exceeding 15 m depth and getting out in soft loose soil for laying cables pipes erection of poles etc complete all as specified and as directed note- excavation shall be carried out manually at certain places wherever directed by the engineer-in-charge at site to avoid breakage of existing electrical water connections quoted rate shall deemed to be include for the manual excavation and nothing extra shall be paid, removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 15m above the starting point complete all as specified and as directed, returning filling in soil including spreading levelling watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed, ml for burnt bricks sub class b old size laid in trenches with equal to length of bricks across the cable for cable protection all as specified and as directed, ml for fine sieved excavated dry soil laid to the required width of trench at bottom and top of cable as cushioning to cable complete all as specified note - thickness shall be measured after punning, supply and lay ht cable xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty 11000 volts grade earthed cable with stranded aluminium conductor cable of size 3 core x120 sqmm complete all as directed note a ht cable route indicator shall be provided at site and quoted rate shall deemed to be included in the quoted rate b the routine tests and acceptance tests as per is 7098 part ii shall be carried out at factory premises and contractor shall submit the test report alongwith paid vouchers and quoted rates shall deemed to be include for the same, supply and lay gi tubes light grade galvanised with all fittings of bore of tube 100mm laid in trenches for drawing cables under roaddrain crossings etc all as specified and directed, ml for making bore hole under the road in any type of soil through trenchless technology by hdd horizontal direction drilling method including preparing and setting up the plant and equipment preparing new pipecable laying work like excavation shoring strutting etc drilling stringing reaming pulling back the new work on the path alignment proper disposal of drilling fluid and the ground penetrating radar survey to protect existing utilities at the pipecable installation location restoration of site after completion all inclusive as per and stt is no 23 22 22 second edition 2008 code of practice of trenchless technology suiting indian condition for making horizontal bore size of 250mm dia suitable for hdpe pipe insertion under the road crossing hard standing including hdpe pipe of size 200 mm nominal dia 2830 mm minimum wall thickness of grade pe 80 16 kgcm2 for protection of ms pipecable to any depth complete all as specified and directed, sf cable jointing kit for 11 kv earthed grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed, sf cable jointing kit for 11 kv earthed grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed, sf cable jointing kit for 11 kv earthed grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed, supply and laying medical gas pipe line oxygen air vacuum made out of copper tubing with 090mm thickness and 15 mm outer dia including different colour code oxygen-yellow air-blue with white colour brand vacuum - blue with black colour brand parallelly drawn fixed on existing wallrooffloor trenches with and including necessary drilling saddling fixing accessories as required for fixing pipe line complete and making good the disturbed surfaces of wall complete all as specified and directed by engineer-in-charge make max flow or other equivalent make approved by cwe note i quoted rate shall inclusive for cutting insertion of necessary t for making new pipe line branches from the existing main source pipes of mh buildings all as specified and directed by engineer-in-charge, s f chromium plated isolation valves minimum working pressure rating of pn 16 or higher to easily safely handle medical gas distribution pressures including necessary testing for leakahes etc complete all as specified and as directed note 3 nos of valve for each ward make conex or other equivalent make approved by cwe, s f din outlets comply with din 13260-2 and en iso 9170-1 iso 9170-1 including necessary testing complete all as specified and as directed note 87 nos of din outlets for each ward make u-metg-flow or other equivalent make approved by cwe
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
ml for disconnecting carefully electrical connection from both ht lt primary secondary sides of the transformer keeping them at safe side and taking out the transformervoltage stabiliser indoor outdoor type of capacity 630 kva to 800 kva 11 kv433kv step down any make for carrying out complete overhauling which shall comprise of the following- a ml for lifting transporting handling the transformer to workshop and back to the original location after complete overhauling or one location to another location where required b conducting the tests on core and windings as per is like ratio magnetic imbalance short circuit etc in presence of engr-in-charge and test results shall be signed both by the contractor and engineer -in-charge and kept on record note- i any damage to insulators bushes windings etc while in the custody of the contractor shall be made good at no extra cost to department the serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody ii ml for rewinding re-insulation of ht lt primary secondary coils bushes studs transformer oil cable box replacement of bucholtz relay mog if any etc will be measured and paid separately, all as per item no 1 herein before but transformervoltage stabiliser indoor outdoor type of capacity up to 400 kva to 500 kva complete all as specified and directed by engr-in-charge, all as per item no 1 herein before but transformervoltage stabiliser indoor outdoor type of capacity up to 100 kva to 315 kva complete all as specified and directed by engr-in-charge, ml for filtration of transformer oil of transformersservo voltage stabilizer installed at various locations to achieve di-electric strength not less than 60 kv at 25mm gap as per relevant is with portable filtration plant testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and directed by engr-in-charge, supply and topping up of transformer oil with di-electric strength not less than 60 kv in to the conservator tank body tank of the transformersservo voltage stabilizer etc at various locations complete all as specified and directed by engr-in-charge make power oil transol sabitha chemicals as approved by ge, ml for rewinding of distribution transformersavr of capacity 100 kva to 800 kva type by winding the low insulationdefective coils of primary coil ht coil with new copper wire as per is of same gauge and existing size together with new insulated materials bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber testing and commissioning the transformer and recording the test results complete all as specified and directed by engr-in-charge note ml for re-insulation of serviceable coils will be measured paid separately under relevant items, ml for rewinding of distribution transformers of capacity 100 kva to 800 kva type by winding the low insulated defective coils of secondary coil lt coil with new copper wire as per is of same gauge and existing size together with new insulated materials bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber testing and commissioning the transformer and recording the test results complete all as specified and directed by engr-in-charge note ml for re-insulation of serviceable coils will be measured paid separately under relevant items, ml for re-insulating windings of distribution transformers of capacity 100 kva to 800 kva size type by strip opening of ht lt coils ie primary secondary coils from core assembly safely unwinding the ht lt coils ie primary secondary coils complete removing the old defective insulation paper and replacing with new dpc insulation to the copper conductor re-varnishing of the windings with super varnish including heating drying backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per is 1986-87 and complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, 500 kva to 800 kva, 100 kva to 400 kva, shifting the transformeravr 100 kva to 800 kva from existing site to another site by dismantling of ht and lt cables jumpers and bus bars including lt busbar cable boxes and close the transformers for loading into vehicle with the help of crane transportation to another site unloading cable connections both ht and lt testing and commissioning complete all as specified and directed by engr-in-charge, ml for replacement of silica gel breather assembly complete with breather unit and silica gel including connecting with proper necessary gaskets if necessary including removing the unserviceable breather assembly complete all as specified and directed by engr-in-charge, ml for replacement of gun metal drain valves of transformers of following capacities including dismantling old one complete all as specified and directed by engr-in-charge make - upadhyay leader zoloto, supply and fixing in repairs off load tap changer assembly suitable for any make with 7 tapping position including opening top cover conservator etc complete all as specified and directed by engr-in-charge, supply and replacement of wti winding temperature indicator of following distribution transformers including dismantling old one complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, 500 kva to 800 kva, 100 kva to 400 kva, ml for replacement of oil gauge glass with gaskets of the following capacity distribution transformers of any makesizetype including dismantling old one complete all as specified and directed by engr-in-charge, 500 kva to 800 kva, 100 kva to 400 kva, ml for replacement of oti oil temperature indicator of following distribution transformers including dismantling old one complete all as specified and directed by the engr-in-charge, ml for replacement of drain plugs to valvesconservator caps of the sizes 34 1 15 valves and plugs of 100 kva to 800 kva capacity distribution transformers of any makesizetype all as directed including dismantling old one complete all as specified and directed by the engr-in-charge, supply and laying of graded coarse aggregate of size 20 mm dia size upto height of 010 mtr in outdoor sub-station yards including surface dressing nexc 05 cm deep and removing debris to a distance nexc 50 m before laying of sand complete all as specified and directed by the engr-in-charge note punned thickness will be measured and paid separately for sand, material labour for excavation in trenches not exceeding 15 metre wide not exceeding 15 meter in depth for foundation laying of cable or pipe where provided for protection of cable or fixing with poles and stays and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the engr-in-charge, material labour for returning filling in including spreading levelling watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the engr-in-charge, material labour for removal excavated material ie soil from site to a distance n exc 50 mtrs away and depositing where directed at a level n exc 15 mtr above the starting point complete all as specified and directed by engr-in-charge, material and labour for river washed and screened dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed by the engr-in-charge note measurement shall be taken after punning down, supplying and laying reinforced precast concrete cable cover class hv type 1 flat size 300mmx 180mm x 40mm laid along alignment of cable as protection to cable in trenches complete all as specified and directed by engineer-in-charge, ml for gi pipe light grade 80 mm dia for cable protection on road crossings plinth protection with fixed to the pole wall etc suitable fittings for cable protection, testing the cables with high voltage dc testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault disconnecting faulty 11 kv ht cables of different sizes from both ends removal of fault re-connections and testing of cables after removal of fault complete all as specified and directed by the engr-in-charge note a 11 kv ht cable joints shall be measured and paid for separately under respective items of schedule b retrieved old serviceable cable cover will be laid in trenches for cable protection if extra pcc cover and sand required at site shall be measured and paid separately under respective items of boqs c excavation and earth work will be measured and paid for separately under respective items of schedule, ml cable jointing kit for 11 kv earthed grade xlpe cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge, ml cable jointing kit for 11 kv earthed grade xlpe cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armored aluminium conductor cable of size 120 to 185 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge note earth work will be measured and paid separately, ml cable jointing kit for 11 kv earthed grade xlpe cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armored aluminium conductor cable of size 240 to 300 sqmm including testing after jointing complete all as specified and directed by the engr-in-charge note earth work will be measured and paid separately, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 95 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 120 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 185 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 240 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, supply laying testing commissioning of xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts grade earthed of size 3 core 300 sqmm complete in trenches ducts on pole etc complete all as specified and directed by the engr-in-charge, servicing inspecting checking overhauling cleaning by using of blower lubrication greasing and carrying out preventive maintanance of rmu capacity 11 kv 250350 mva including calibrating the relay by conducting secondary injection tests and rmu in serviceable condition testing and commissioning complete all as specified and directed by the engr-in-charge notes i the rate quoted shall be deemed to include for necessary tp nuts bolts washers gasket insulation tape compound painting of rmu panels with approved colour including lettering details all as per exisitng etc, self powered relay with oc sc ef protectionrelay should have a front usb port for laptop interface lcd display 10 event records 5 fault records min 2 setting group and keypad for setting parameters for the relay suitable fo rmu, ct having ratio 100-501-1a for class - 10 25va for metering and class 10p10 25va for protection- 1set, cable termination bushing suitable for upto 1 run 3cx185 sq mm xlpe cable- 1set, cable termination cover boots push on type -1set, three phase ryb indicating lamps - 1set, 11kv230v ac 1kva control transformer - 1no, battery and battery charger 12ah ip-230v ac op - 24v dc - 1no, spring charging motor, ml of notice plate of 16 mm thick mild steel sheet vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with ms clamps bolts and nuts of approved size for ht 11 kv of size 25 x 20 cm, disconnection and taking out the idmt numeric microprocessor based relay of any type of any make from 11 kv ht panel cleaning the contacts calibrating the relay by conducting secondary injection tests checking of current transformer rectification of defects in control wiring for proper tripping of circuit breakers through cts and relay and tripping coils adjustmentsetting to plug and time multiplier settings of the relay to achieve the discrimination in tripping tunesynchronise upstream breaker relay settings re-installation of relay testing commissioning etc complete all as specified and directed by the engr-in-charge note the contractor has to arrange necessary testing kits testing equipments tools etc rental rates for the testingcalibration kits connected equipments are deemed to be included in the quoted rate testing tuning shall be carried out in the presence of representative of the department to the satisfaction of the department, taking down ht switch gear vacuum circuit breaker at sub stn of capacity 11 kv 250350 mva comprising of repairs complete overhaulingservicing carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repairs overhauling note i the servicing includes for busbar duct chamber cable alleys and connecting accessories ii the rate quoted shall be deemed to include for necessary tp nuts bolts washers gasket insulation tape compound painting of vcb panels with approved colour including lettering details all as per existing etc to put in to the vcbs and panels in serviceable condition testing and commissioning all as specified and as directed by the engineer-in-charge iii major spares like breaker bushings vacuum interrupter assly busbar spout busbar spout connections circuit spoutcircuit spout connectionsbuffer fixed contacts moving contacts tank asslybarriers solenoid spares dependentspring mechanism motor mechanism trip unit etc will be measured and paid separately under relevant items of schedule a however the rate quoted shall be deemed to include for any other minor spares require replacement iv the servicing shall be carried out by auhtorised agencyrep of oem of vcb, supplying and laying as replacement in sub station 33 to 11 kv electrical insulation mat of size 5 mtr x 1 mtr x 25 mm thick confirming to is 15652 2006 complete all as specified and directed by engineer- in- charge, platform - ml for brick masonary using sub class b brick platform of size 3m x 3m x 1m height built in cm 14 complete incl all necessary excavation earth work pcc 148 type d-2 in foundation 15 mm thick rendering in cm 16 on sides and top of the brick work up to 150 mm below ground level incl sf of 02 nos ms channels of size ismc-100 for balancing of transformer embedded in pcc 124 type b-1 up to 100 mm thick rcc 124 with 10 mm steel bar placed 100mm cc including provn of steps on one side complete all as specified and directed by engineer- in- charge, fencing - ml for perimeter fencing of size 8mx4mx2m as per site condition having ms work of angle iron for post and struts of fencing around the transformer plinthsubstationlt panels etc drilling holes flat iron fillet for securing wire mess by welding to angle iron frame and framed work as in doorgate of angle iron and wiremeshdoor to be fixed by 03 nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed by engr- in- charge details are as follows- a angle iron post to post distance maintained not more than 02mtr size of angle shall be 40x40x5mm angle iron shall be embedded in natural ground not less than 090 m deep b ms wire 75x75mm mesh 315 mm dia 2mtr height and shall be fixed to post with flat iron 32 x 6 mm fillet with two coats of synthetic enamel paint over a coat of red oxide primer c cement concrete type d-2 148 using grade crushed stone aggregate for mass concrete foundation d brickwork with subclass b bricks straights or curved on plane exc 6m mean radius built in cement mortar 16 complete for toe wall along the perimeter fencing the toe wall shall be one brick thick 30cm high 15cm above gl and 15cm below gl on 75mm thick pcc lean concrete e the exposed surfaces of brickwork shall be rendered 15mm thick in cm 14 finished fair and even without using extra cement f the steel gate shall be of size 100m x200 m fabricated from angle iron 40x40x5 mm frame and 12x12 mm square guard bars g all the exposed surfaces of steel shall be painted with two coats of synthetic enamel paint over one coat of red oxide primer h dry stone aggregate of size 40mm spreaded leveled compacted up to 100mm thick j necessary excavation and earthwork shall be included in the quoted rate, m l for painting of vcb with si-coat 570 rtv silicone high voltage insulator coating solution prior to cleaning the complete paint surface with silica paper blower heat blower complete all as specified and directed by the engr-in-charge, supply of ht insulation tape complete all as specified and directed by the engr-in-charge
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
dismantling taking down centrifugal pump set from platform and disconnecting suction delivery pipe line electrical connections transport the same to workshop for repairie machine work welding grinding turning polishing lathe work filler work etc complete as required on site and after repairing transporting the pump set from workshop to site installation at site connecting suction delivery pipe and electrical connection complete all as directed by engineer-in-charge for 120 hp capacity pumps note- i the quoted rate shall deemed to be inclusive of the cost of providing foundation nuts bolts washers gland packing greasing oiling and oil sheet gasket ii the spare parts shall be measured and paid separately under relevent items of this boq no extra payment will be made to the contractor for any additional requirement for fixing reinstalling the pump motor set iii gland packing greasing and oiling shall be changed at the time of repairs, all as per item no 1 above but 100 hp, all as per item no 1 above but 75 hp, all as per item no 1 above but 5040 hp, all as per item no 1 above but 30 20 hp, all as per item no 1 above but 12515hp, all as per item no 1 above but 1075 hp, all as per item no 1 above but 5 3 25 hp, material and labour for disconnecting the motor by delinking the centrifugal pump set transporting to workshop opening the motor removing the unserviceableburnt windings from the motor stator cleaning the stator slots with petrol rewinding with existing size of copper winding wire insulating to the existing class of insulation varnishing ovening etc testing at factory under no load assembling transporting to site fixing on foundation re-assembling the motor and testing at load to the satisfaction of engineer-in-charge for motor capacity 100120 hp - note -i transportation and necessary tp for shifting the motor to workshop back is included in the quoted rates ii major spares like coupling bearings etc will be measured and paid under respective item of schedule a, all as per item no 9 above but 5075 hp, all as per item no 9 above but 203040 hp, all as per item no 9 above but 151251075 hp, all as per item no 9 above but 2535 hp, supply only ci impeller suitable of 120 hp capacity centrifugal pump sets, supply only casing ring suitable of 120 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 120 hp capacity centrifugal pump sets, supply only impeller key suitable of 120 hp capacity centrifugal pump sets, supply only coupling key suitable of 120 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 120 hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 120 hp capacity centrifugal pump sets, supply only bearing suitable of 120 hp capacity centrifugal pump sets, supply only brass bush suitable of 120 hp capacity centrifugal pump sets, supply only shaft suitable of 120 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 120 hp capacity centrifugal pump sets, supply only gland cap ci suitable of 120 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 120 hp capacity centrifugal pump sets, supply only ci impeller suitable of 100 hp capacity centrifugal pump sets, supply only casing ring suitable of 100 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 100 hp capacity centrifugal pump sets, supply only impeller key suitable of 100 hp capacity centrifugal pump sets, supply only coupling key suitable of 100 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 100 hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 100 hp capacity centrifugal pump sets, supply only bearing suitable of 100 hp capacity centrifugal pump sets, supply only brass bush suitable of 100 hp capacity centrifugal pump sets, supply only shaft suitable of 100 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 100 hp capacity centrifugal pump sets, supply only gland cap ci suitable of 100 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 100 hp capacity centrifugal pump sets, supply only ci impeller suitable of 7550 hp capacity centrifugal pump sets, supply only casing ring suitable of 7550 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 7550 hp capacity centrifugal pump sets, supply only impeller key suitable of 7550 hp capacity centrifugal pump sets, supply only coupling key suitable of 7550 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 7550 hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 7550hp capacity centrifugal pump sets, supply only bearing suitable of 7550hp capacity centrifugal pump sets, supply only brass bush suitable of 7550 hp capacity centrifugal pump sets, supply only shaft suitable of 7550 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 7550hp capacity centrifugal pump sets, supply only gland cap ci suitable of 7550 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 7550 hp capacity centrifugal pump sets, supply only ci impeller suitable of 3040 hp capacity centrifugal pump sets, supply only casing ring suitable of 3040 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 3040 hp capacity centrifugal pump sets, supply only impeller key suitable of 3040 hp capacity centrifugal pump sets, supply only coupling key suitable of 3040 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 3040 hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 3040hp capacity centrifugal pump sets, supply only bearing suitable of 3040hp capacity centrifugal pump sets, supply only brass bush suitable of 3040 hp capacity centrifugal pump sets, supply only shaft suitable of 3040 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 30400hp capacity centrifugal pump sets, supply only gland cap ci suitable of 3040 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 3040 hp capacity centrifugal pump sets, supply only ci impeller suitable of 2015125 hp capacity centrifugal pump sets, supply only casing ring suitable of 2015125 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 2015125 hp capacity centrifugal pump sets, supply only impeller key suitable of 2015125 hp capacity centrifugal pump sets, supply only coupling key suitable of 2015125 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 2015125 hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 2015125 hp capacity centrifugal pump sets, supply only bearing suitable of 2015125 hp capacity centrifugal pump sets, supply only brass bush suitable of 2015125 hp capacity centrifugal pump sets, supply only shaft suitable of 2015125 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 2015125 hp capacity centrifugal pump sets, supply only gland cap ci suitable of 2015125 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 2015125 hp capacity centrifugal pump sets, supply only ci impeller suitable of 755325 hp capacity centrifugal pump sets, supply only casing ring suitable of 755325 hp capacity centrifugal pump sets, supply only impeller ring brass nut suitable of 755325 hp capacity centrifugal pump sets, supply only impeller key suitable of 755325 hp capacity centrifugal pump sets, supply only coupling key suitable of 755325 hp capacity centrifugal pump sets, supply only coupling rubber bushes tyre coupling suitable of 755325hp capacity centrifugal pump sets, supply only shaft sleeve steel suitable of 755325 hp capacity centrifugal pump sets, supply only bearing suitable of 755325 hp capacity centrifugal pump sets, supply only brass bush suitable of 755325 hp capacity centrifugal pump sets, supply only shaft suitable of 755325 hp capacity centrifugal pump sets, supply only ms coupling beam jaw gear any type for both pump and motor suitable of 755325 hp capacity centrifugal pump sets, supply only gland cap ci suitable of 755325 hp capacity centrifugal pump sets, supply only gland bolt and nut suitable of 755325 hp capacity centrifugal pump sets, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 120100 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 755040 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 302520 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 1512510 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 755 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs motor cooling fan of same size as existing suitable for motor of 32 hp capacity centrifugal pump sets including all fiiting fixtures etc as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 120100 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 755040 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 302520 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 1512510 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 755 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply and fix in repairs front rear ends bearing of same size as existing suitable for motor of 32 hp capacity centrifugal pump sets including all fiiting fixtures etc incl taking out motor if not in repair as directed by engr-in-charge, supply laying and fixing or passing through pipes ducts or laid under floor of through walls etc jointing and testing lt xlpe insulated pvc sheathed electric cable 1100 volt grade heavy duty isi marked with copper conductor and over all served with an outer sheath of pvc from panel to motor including providing copper lugs as per site requirement including taking down old cable complete size of cable 70 sqmm single core as specified and directed by engineer-in-charge note- cost of dwc pipe of suitable size for laying of xlpe copper cable from panel to motor for sizes up to 70 sqmm shall deemed to be included in the quoted rate, all as per item 104 above but size of cable 35 sqmm single core, all as per item 104 above but size of cable 25 sqmm single core, all as per item 104 above but size of cable 16 sqmm single core, taking out the submersible pump set of 10755 hp capacity from deep bore well with connected cable and column pipes of 3m length with flange end 32 dia appx 10 nos per bore well and disconnecting the cable for removing the submersible pump set for carrying out necessary repairs all as directed by engineer-in-charge, lowering of submersible pump set 10755 hp in bore well with connected cable column pipes re-assembling column pipe of 3m long with flange ends 32 dia appx 10 nos and testing and commissioning of pump set after repairs including rectification of any leakage to the entire satisfaction of engineer-in-charge, repairs to submersible pumping set 10755 hp by dismantling pumps and motor carrying out required repairs to pump by machines ie grindingpolishing reassembling after renewal of all worn out spare parts cleaning and refixing with motors with required coupling etc complete testing all as specified directed by engineer-in-charge note - i rewinding of motor renewal of parts will be measued paid separately ii rate of taking down of old unserviceable spare parts shall be included in quoted rate of this item, rewinding of ac 3 phase induction motor of 10 hp capacity submersible pump motor by cutting of burnt out winding cleaning of starter slots cleaning bleaching of motor and rewinding with appropriate gauge of pvc insulated copper winding wire complete including all required parts complete all as specified directed by engineer-in-charge, rewinding of ac 3 phase induction motor of 755 hp capacity submersible pump motor by cutting of burnt out winding cleaning of starter slots cleaning bleaching of motor and rewinding with appropriate gauge of pvc insulated copper winding wire complete including all required parts complete all as specified directed by engineer-in-charge, taking out the submersible pump set of 50 hp capacity from rainwater sump at cair with connected cable and column pipes of 3m length with flange end 32 dia and disconnecting the cable for removing the submersible pump set for carrying out necessary repairs all as directed by engineer-in-charge, repairs to submersible pumping set 50 hp by dismantling pumps and motor carrying out required repairs to pump by machines ie grindingpolishing reassembling after renewal of all worn out spare parts cleaning and refixing with motors with required coupling etc complete testing all as specified directed by engineer-in-charge note - i rewinding of motor will be measued paid separately ii rate of renewalrepairs of unserviceable parts of motor and pump set are deemed to be included in the quoted rate and incl taking down of old unserviceable spare parts shall be included in quoted rate, rewinding of ac 3 phase induction motor of 50 hp capacity submersible pump motor by cutting of burnt out winding cleaning of starter slots cleaning bleaching of motor and rewinding with appropriate gauge of pvc insulated copper winding wire complete including all required parts complete all as specified directed by engineer-in-charge, supply only for fixing thrust bearing plate for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing assembly for coupling sleeve for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing winding protector set for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing motor bearing bush for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing drain plug for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing sand guard for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing key for thrust plate for motor of submersible pump set suitable for 10755 hp motor, supply only for fixing impeller of submersible pump set suitable for 10755 hp pump, supply only for fixing stage bowl of submersible pump set suitable for 10755 hp pump, supply only for fixing bowl fixing steel bolt and nut with washer of submersible pump set suitable for 10755 hp pump, supply only for fixing bearing sleeve of submersible pump set suitable for 10755 hp pump, supply only for fixing shaft nut with washers of submersible pump set suitable for 10755 hp pump, supply only for fixing suitable bearing bush of submersible pump set suitable for 10755 hp pump, supply only for fixing suitable neck ring of submersible pump set suitable for 10755 hp pump, supply only for fixing casing wear ring of submersible pump set suitable for 10755 hp pump, supply only for fixing suitable strainer of submersible pump set suitable for 10755 hp pump, supply only for fixing suitable shaft seal of submersible pump set suitable for 10755 hp pump, supply only for fixing stage gasket of submersible pump set suitable for 10755 hp pump, m l for lifting the submersible non clog type pumpset of 151075 hp capacity from sewage well disconnecting the cable transporting the pumpset to workshop dismantling the motor megger testing the motor removing the burnt damaged winding rewinding with appropriate size of copper winding wires re-insulation with appropriate class of insulation to the existing class varnishing and bakeing replacing the wornout bearing bushing assembling testing of motor opening the pump set cleaning the impellers supplying and fixing required nos of bearing bush after removing existing worn out bush bearing of pump set upto 08 stages assembling the pump re-assembling the motor pump shifting to site connecting the cable and lowering the pump set along with gi pipes cables including testing complete all as directed note major spares like impeller etc will be measured paid separately, s f in repair contactor 3 phase ac 440 volt of 25 amps capacity complete all as specified directed by engineer-in-charge, s f in repair contactor 3 phase ac 440 volt of 32 amps capacity complete all as specified directed by engineer-in-charge, s f in repair contactor 3 phase ac 440 volt of 40 amps capacity complete all as specified directed by engineer-in-charge, s f in repair contactor 3 phase ac 440 volt of 70 amps capacity complete all as specified directed by engineer-in-charge, s f in repair contactor 3 phase ac 440 volt of 95 amps capacity complete all as specified directed by engineer-in-charge, s f in repair contactor 3 phase ac 440 volt of 115 amps capacity complete all as specified directed by engineer-in-charge, repairreplacement of following us itemsparts of lt panel board if required with necessary copper wiring lugs etc complete to make item functional all as specified and directed by engineer-in-charge- a digital voltmeter 0-500 v, all as per item 141 above but b digital ammeter 0-200 a, all as per item 141 above but c ammeter ct type 0-300 a, all as per item 141 above but d selector switch as per existing, all as per item 141 above but e phase indicator r y b as per existing, all as per item 141 above but f electronic relay of any required size, all as per item 141 above but g aluminium busbar as per existing, all as per item 141 above but h cable lugs as per existing, sf on load change over switch four pole 400a 415 volts ac manual changeover open execution type with handle including taking down old change over switch connection complete all as directed, m l for disconnecting the electrical connections from the panel to the sewage motor 30 hp dis-connecting the pump motor and shifting the same to the upper platform from the sewage well carefully using necessary t p and dismantling the rusted structural steel base plate from the foundation bed fabricating new base plate using structural steel sections of the same shape size of the existing base plate applying two coats of synthetic enamel black paint over a coat of red oxide fixing complete on the exisitng foundation bed using new foundation bolts as required at site lowering of the pump motor fixing on the base plate with proper shaft allignment and connecting with coupling connecting the electrical water connections checking for smooth running of the pump complete all as directed note - 1 steel sections and coupling shall be measured and paid seperatly under respective items of this schedule 2 the quoted rates are inclusive of necessary t p painting nuts bolts washers etc, repairs to sewage motor 30 hp by dismantling pumps and motor carrying out required repairs to pump by machines ie grindingpolishing reassembling after renewal of all worn out spare parts cleaning and refixing with motors with required coupling etc complete testing all as specified directed by engineer-in-charge note - i rewinding of motor renewal of parts shall be measued paid separately ii rate of taking down of old unserviceable spare parts shall be included in quoted rate of this item, taking out angle iron and m l for rolled mild steel in joists channel angle or tee sections as in main and cross beams of fe 410-w grade steel for ladders for ug sumps oh tanks including cutting welding grinding sharp corners etc all as directed note - the quoted rates are inclusive of unloading fabrication work at site reducing to required shape size hoisting fixing etc including prepration of new untreated surfaces and painting of with one coat of red oxide primer and two coats of black paint all as required at site including taking down the old unsv ones complete all as directed, dismantling of existing panel board of any type with all accessoires complete design supply installation testing and commissioning of factory-built indoor double door lt panel cubicle type floor mounted compartmentalised fabricated from crca sheet steel with minimum 20 mm thick doorsfront coversload-bearing members and 16 mm internal partitionsgland plates the enclosure shall be phosphated by seven-tank pretreatment and finished with epoxy polyester powder coating of minimum 80 microns shade ral 7035 suitable for indoor use enclosure shall be suitable for ac supply system 415 volts 3 phase 4 wire 50 hz degree of protection shall be ip-54 cable entry from bottom side in separate cable alley on both sides separated with bakelite sheet of suitable size including internal wiring with pvc insulated stranded copper wire 1100 volts grade panel shall conform to isiec 61439-1 61439-2 and be routinetype tested the panel shall consist of electrolytic grade tpn aluminium bus bars with rated at minimum 15 times the main incoming switchgear rating provided with colour coded heat shrinkable sleeves the panel shall be provided with separate compartments for each switchgear including instrumentation such as ammeters voltmeter phase indicating lamps etc with double-stud hinged door front rear openable with locking arrangement including interlocking with switchgears the panel shall be fixed on angle iron frame made of angles 50 x 50 x 6 mm embedded 200 mm below ground level in pcc 124 type b-1 using 20 mm grade stone aggregate 600 mm above ground level the panel is designed for 02 nos centrifugal pump motors of 100 hp 746 kw rating full load current 136 a each with electronic soft starters with integral bypass contactor and comprehensive motor protection comprising the following, dismantling of existing panel board of any type with all accessoires complete design supply installation testing and commissioning of factory-built indoor double door lt panel cubicle type floor mounted compartmentalised fabricated from crca sheet steel with minimum 20 mm thick doorsfront coversload-bearing members and 16 mm internal partitionsgland plates the enclosure shall be phosphated by seven-tank pretreatment and finished with epoxy polyester powder coating of minimum 80 microns shade ral 7035 suitable for indoor use degree of protection ip-54 enclosure shall be suitable for ac supply system 415 volts 3 phase 4 wire 50 hz cable entry from bottom side in separate cable alley on both sides separated with bakelite sheet of suitable size including internal wiring with pvc insulated stranded copper wire 1100 volts grade panel shall conform to isiec 61439-1 61439-2 and be routinetype tested the panel shall consist of electrolytic grade tpn aluminium bus bars with rated at minimum 15 times the main incoming switchgear rating provided with colour coded heat shrinkable sleeves the panel shall be provided with separate compartments for each switchgear including instrumentation such as ammeters voltmeter phase indicating lamps etc with double-stud hinged door front rear openable with locking arrangement including interlocking with switchgears the panel shall be fixed on angle iron frame made of angles 50 x 50 x 6 mm embedded 200 mm below ground level in pcc 124 type b-1 using 20 mm grade stone aggregate 600 mm above ground level the panel is designed for 02 nos centrifugal pump motors of 120 hp 895 kw rating full load current 163 a each with electronic soft starters with integral bypass contactor and comprehensive motor protection comprising the following, taking down of existing old and unservicebale flow meter of any design and type design supply installation testing and commissioning of electromagnetic flowmeter dn250 with remote external flow display ip65ip67 protection suitable for outdoor installation complete with instrumentation signal cabling suitable for continuous flow measurement on 250 mm dia potablerawtreated water pumping main with flow indication displayed remotely inside pump house the item comprises the following a programmable remote external digital flow display unit suitable for receiving 4-20 ma hart signal from the electromagnetic flow meter and displaying instantaneous flow rate cumulative flow cumhr cumday and mld inside pump house complete with minimum 4-digit ledlcd display programmable engineering units isolated analogue input configurable scaling totaliser function minimum 2 alarm relays accuracy better than 01 230 v ac auxiliary supply ip54 enclosure wallpanel mounting arrangement surge protection and all mounting hardware wiring terminals and accessories required for satisfactory operation 01 no make siemens sitrans rd100 cat no 7ml5741-1ab00-0ad0 schneider electric harmony indicator cat no xbtgt2220 autonics mt4w-dv-41 b i measuring principle faradays law of electromagnetic induction full bore bidirectional flow measurement virtually independent of pressure density temperature and viscosity of the medium ii nominal diameter dn250 10 suitable for 250 mm dia water pipeline iii measuring range device family 05 mh to 263 000 mh 25 galmin to 1665 mgald scaled to line size and application iv accuracy 05 of reading 1 mms 004 ins standard measurement error v max process pressure rating pn40 class 300 20k, ml for design fabrication supply transportation erection testing and commissioning of premium outdoor weatherproof illuminated main entrance sign board comprising 3 mm thick exterior grade pvdf coated fire-retardant acp fascia panel aludecor viva eurobond alstone or equivalent with cncrouter cut openings for letters logos and insignia edge folding and finishing complete fabricated ms internal structural framework of 40402 mm min shs complete with cutting welding grinding one coat zinc chromate primer and two coats synthetic enamel paint finish designed to withstand wind and dead loads 3d raised illuminated acrylic letters numerals bilingual text insignia and logo made from 8 mm thick imported cast acrylic face sun acryl jindal equivalent approved lasercnc cut uv resistant with 3 mm acrylicaluminium returns 50100 mm depth as approved and 5 mm pvcacrylic backing letters fixed with concealed ss stud fixing system complete with high brightness ip65ip66 waterproof led modules samsung philips osram operating on 12v dc through weatherproof constant voltage smps driver meanwell philips inventronics hilux with surge overload and short circuit protection minimum 50 000 hr led life cool white 6500k or as approved including complete internal frls copper wiring ferrules connectors ip65 junction boxes and accessories providing and fixing ss-304 grade decorative outer boundary frameborder fabricated from minimum 12 mm thick ss sheetbox section jindal tata ss or equivalent mirror or hairline satin finish seamlessly welded polished and decoratively buffed at corners providing and fixing ss-304 grade support polesmounting structure of minimum 150 mm dia with coating of red oxide and two coats of black paint with 10 mm thick ss base platesheight may vary from 2m to 6m ss-304 anchor bolts chemical anchoring clamps gussets and bracing capable of withstanding wind load up to 180 kmph and full dead load of sign board including frls 15 sqmm copper wiring in uv resistant pvcflexible conduit 6a sp mcb isolator weatherproof silicone sealing scaffolding hoisting welding drilling alignment testing commissioning cleaning and handing over, m l for laying connecting testing three core 6 sqmm copper conductor flexible pvc insulated pvc sheathed heavy duty flat cable 1100 volts grade for centrifugalsewage non clog pumps from panel to motor duly clamped on walls run through conduits etc including taking out unserviceable cable all as speciifed and as directed, material and labour for scraping the peeled off paint of pumping set up to 120 hp capacity along with base foundation plate applying metal paste on uneven surfaces to make the surface smooth and applying a coat of synthetic enamel paint of existing shade and writing the mes sm number on the motor pump set all as directed, material and labour for scraping the peeled off paint of suction delivery water lines ms duct covers control valves at pumping installations upto 6 mtr from pump outlet and 3 mtr from pump outlet applying metal paste on uneven surfaces as necessary to make the surface smooth and applying a coat of synthetic enamel paint of existing shade and sign writing all as directed, supply fix in repairs mccb 400 amps 35 ka 4 pole adj thermal and adj magnetic release trip unit 415 volt ac 50 hz ics-100icu including connecting up incoming out going cables with suitable lugs and testing complete all as specfied and as directed, supply fix in repairs mccb 250 amps 25 ka 4 pole adj thermal and adj magnetic release trip unit 415 volt ac 50 hz ics-100icu including connecting up incoming out going cables with suitable lugs and testing complete all as specfied and as directed, supply fix in repairs mccb 200 amps 25 ka 4 pole adj thermal and adj magnetic release trip unit 415 volt ac 50 hz ics-100icu including connecting up incoming out going cables with suitable lugs and testing complete all as specfied and as directed, supply fix in repairs mccb 100 amps 25 ka 4 pole adj thermal and adj magnetic release trip unit 415 volt ac 50 hz ics-100icu including connecting up incoming out going cables with suitable lugs and testing complete all as specfied and as directed, supply and fix in repairs mccb 4 pole 415 volts 125 amps 25 ka 50 hz ac adj thermal and adj magnetic release trip unit ics-100icu including connecting up incoming out going cables with suitable lugs and testing complete all as specified and as directed, earthing complete with galvanised steel earth plate electrode 60cm x 60cmx 60mm thick burried directly in ground vertically earth pit not less than 225m deep below ground level with top edge of the earth plate not less than 15m deep below normal ground level connected to galvanised iron strip 32x6 mm 75m length by means nuts check nuts and washers of gi or steel connected to main switch board including watering arrangement with pcc chamber ms wire gauge ci cover with frame incl excavation in any strata and returning filling removal surplus soil charcoal salt complete all as shown in electric plate no 3 of ssr part i earth test point shall be provided at suitable point, ml for cleaning of ug sewage sump by draining out water removing the silt mud and any other foreign materials from bottom of well of capacity up to 60 lakh ltrs using vehicle kambi 6 lcn mounted with compressor and sucker tank of ms kam-avida enviro engineers pvt ltd pune or similar model vehicle washing down with water for smooth functioning of sewage pipe lines disfection with bleaching powder etc applying one coat of white wash for the entire surfaces complete all as specified and as directed note the receipt of payment made towards the vehicle charges for removing of sludge shall be attached with the completion report submission without original receipt payment will not be done to the contractor, chemical and bacteriogical analysis of water as per is-10500 sample collected from bore wellsshallow wellsbwssb water user point all as directed by engr-in-charge note - water to be tested once in 1 months and approved at nabl lab note the receipt of payment made towards the water analysis charges to nabl lab shall be attached with the report submission without original receipt payment will not be made to the contractor
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
m l for disconnecting all electric and water supply connections and other related items and lifting the unserviceable centrifugalmono block pump of capacity 4050hp 3 phase 415 v by mechanicalmanual method including dismantling the water supply lines and keeping the same in safe custody for repair including transportation of the defective pump set and motor from pump house to workshop for repair and back and re-installation the same on exisisting position after necessary repair including testing on completion all as directed by the engr-in-charge, m l for disconnecting all electric and water supply connections and other related items and lifting the unserviceable centrifugalmono block pump of capacity 20-30 hp 3 phase 415 v by mechanicalmanual method including dismantling the water supply lines and keeping the same in safe custody for repair including transportation of the defective pump set and motor from pump house to workshop for repair and back and re-installation the same on exisisting position after necessary repair including testing on completion all as directed by the engr-in-charge, m l for disconnecting all electric and water supply connections and other related items and lifting the unserviceable centrifugalmono block pump of capacity 75 to 15 hp 3 phase 415 v by mechanicalmanual method including dismantling the water supply lines and keeping the same in safe custody for repair including transportation of the defective pump set and motor from pump house to workshop for repair and back and re-installation the same on exisisting position after necessary repair including testing on completion all as directed by the engr-in-charge, m l for disconnecting all electric and water supply connections and other related items and lifting the unserviceable centrifugalmono block pump of capacity 5 hp 3 phase 415 v by mechanicalmanual method including dismantling the water supply lines and keeping the same in safe custody for repair including transportation of the defective pump set and motor from pump house to workshop for repair and back and re-installation the same on exisisting position after necessary repair including testing on completion all as directed by the engr-in-charge, m l for disconnecting all electric and water supply connections and other related items and lifting the unserviceable centrifugalmono block pump of capacity 2 to 3 hp capacity 3 phase 415 v by mechanicalmanual method including dismantling the water supply lines and keeping the same in safe custody for repair including transportation of the defective pump set and motor from pump house to workshop for repair and back and re-installation the same on exisisting position after necessary repair including testing on completion all as directed by the engr-in-charge, m l for dismantling the unserviceable parts and burnt out copper winding from pump - motor of capacity 30 to 50 hp 3 phase 415v and rewinding the motor with supper enamelled copper wire of suitable gauge including heating varnishing replacement of defective spare parts re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence at site as directed note- a spare parts copper winding wire will be measured paid seperately as all as per supply only 2 labour charge for fixing parts shall deemed to be included in the unit rate, m l for dismantling the unserviceable parts and burnt out copper winding from pump - motor of capacity 75 to 20 hp 3 phase 415v and rewinding the motor with supper enamelled copper wire of suitable gauge including heating varnishing replacement of defective spare parts re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence at site as directed note- a spare parts copper winding wire will be measured paid seperately as all as per supply only 2 labour charge for fixing parts shall deemed to be included in the unit rate, m l for dismantling the unserviceable parts and burnt out copper winding from pump - motor of capacity 2 to 50 hp 3 phase 415v and rewinding the motor with supper enamelled copper wire of suitable gauge including heating varnishing replacement of defective spare parts re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence at site as directed note- a spare parts copper winding wire will be measured paid seperately as all as per supply only 2 labour charge for fixing parts shall deemed to be included in the unit rate, supply only copper winding wire with supper enamelled copper wire of suitable gauge as per capacityrating of motor complete all as specified and directed by engr - in - charge, taking down the unserviceable parts from the centrifugal pump of capacity 30-50 hp three phase 415 v including over hauling servicingcleaning throughly discharge suction cases impellers shaft and re-assembling pump carefully including servicing cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repairreplacement of unservicable parts as required at site etc and re-assemblingre-installing the pump complete all as specified and directed note- a spare parts shall be measured paid seperately as supply only items b labour charge for fixing parts shall deemed to be included in the unit rate, taking down the unserviceable parts from the centrifugal pump of capacity 75 to 20 hp three phase 415 v including over hauling servicingcleaning throughly discharge suction cases impellers shaft and re-assembling pump carefully including servicing cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repairreplacement of unservicable parts as required at site etc and re-assemblingre-installing the pump complete all as specified and directed note- a spare parts shall be measured paid seperately as supply only items b labour charge for fixing parts shall deemed to be included in the unit rate, taking down the unserviceable parts from the centrifugal pump of capacity 2 to 50 hp three phase 415 v including over hauling servicingcleaning throughly discharge suction cases impellers shaft and re-assembling pump carefully including servicing cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repairreplacement of unservicable parts as required at site etc and re-assemblingre-installing the pump complete all as specified and directed note- a spare parts shall be measured paid seperately as supply only items b labour charge for fixing parts shall deemed to be included in the unit rate, m l for machine work to the worn out portion of non clog submersible pump shaft of capacity including metalling cutting polishing and checking the accuracy on the lath machine complete all as directed by engr-in-charge, supply only ball bearing for motor all as per existing and specified and directed by engr-in-charge, supply only mechanical seal for for pump - motor all as per existing ans specified and directed by engr-in-charge, supply only impeller as per existing all as per specified and directed by engr-in-charge, supply only impeller key as per existing all as per specified and directed by engr-in-charge, m l for machine work to the worn out portion of non clog submersible pump shaft of capacity including metalling cutting polishing and checking the accuracy on the lath machine complete all as directed by engr-in-charge, supply only ball bearing for motor all as per existing and specified and directed by engr-in-charge, supply only mechanical seal for for pump - motor all as per existing ans specified and directed by engr-in-charge, supply only impeller as per existing all as per specified and directed by engr-in-charge, supply only impeller key as per existing all as per specified and directed by engr-in-charge, m l for machine work to the worn out portion of non clog submersible pump shaft of capacity including metalling cutting polishing and checking the accuracy on the lath machine complete all as directed by engr-in-charge, supply only ball bearing for motor all as per existing and specified and directed by engr-in-charge, supply only mechanical seal for for pump - motor all as per existing ans specified and directed by engr-in-charge, supply only impeller as per existing all as per specified and directed by engr-in-charge, supply only impeller key as per existing all as per specified and directed by engr-in-charge, m l taking out vertical submersible pump motor set from existing borewellof capacity from 20 hp to 75 hp capacity dismantling pump complete after disconnecting all electrical connections and repairoverhauling including replacement of following worn out parts as per sample note i spares required for replacement shall be measured and paid as supply only under respective items ii reassembling lowering in sewage sump to its original place testing and transport will be included in quoted rate, supply only gun metal bush of capacity complete all as specified directed, supply only impeller complete all as specified and directed, supply only impeller key complete all as specified and directed, supply only neck ring bronze complete all as specified and directed, supply only guide ring complete all as specified and directed, supply only lock bolt for impeller complete all as specified and directed, supply only shaft sleeve complete all as specified and directed, supply only shaft coupling screwed complete all as specified and directed, supply only coupling pin bush complete all as specified and directed, supply only ball bearing complete all as specified and directed, supply only lock bolt for shaft coupling complete all as specified and directed, all as per item no 1501 but top shaft complete all as specified and directed, supply and fix in repair dol starter along with single phase preventor in sheet steel enclosure 3 phase 415 volts with contactor suitable for 1 to 6 hp electric motor complete all as specified and directed make lt mk1 dol bchhavells, supply and fix in repair dol starter suitable of pumps of capacity upto 10hp heavy duty complete including replacement of existing starter complete make la mk1 dol bchhavells, supply and fix in repair fully automatic fasd star delta starter along with single phase preventor in powder coated enclosure with pu gasket suitable 5 hp to 10 hp including all electric connection with ammeter and volt meter onoff trip indicator including protection against phase failure phase imbalance phase reversal complete all as specified and directed make lt mk1 fasdbch havells, m l for repairservicing of existing sluice valve of 100 mm after dismantling of upper cover remove the spindle and make it leak proof by replace the gland packing nut bolt with washer and gasket of both side all as per specified and directed by engr-in-charge, m l for repairservicing of existing sluice valve of 150 mm after dismantling of upper cover remove the spindle and make it leak proof by replace the gland packing nut bolt with washer and gasket of both side all as per specified and directed by engr-in-charge, s f in replacement voltmeter digital type complete all as specified and directed by engineer - in - charge, s f in replacement ammeter digital type of capacity up to 100 amp complete all as specified and directed by engineer - in - charge, supply and fix in repairs on-off push button pendants with elements red green orange complete all as specified and as directed by engr-in-charge, supply fixing mcb single pole and neutral spn of capacity 63 amps 240 volts breaking capacity 10 ka c series fixed in proper position all as directed by the engineer-in-charge make legrand or equivalent, supply fixing mcb single pole sp of capacity 6 amps to 32 amps 240 volts ac breaking capacity 10 ka c series fixed in proper position all as directed by the engineer-in-charge make legrand or equivalent siemensabb, material and labour for development of tube well by at the site including dismatling existing gicpvchdpe bore well pipes up to 120 mtrs depth including taking up submersible pumps and flushing of bore well with air compressor of capacity 250psi1000 cum and related accessories at least 10 hours till water discharge is free from sand and potable water and to achieve maximum discharge capacity including necessary development complete and lowering submersible pump with gicpvchdpe borewell pipes complete including testing of borewell all as specified and directed note i unit rate quoted under this items shall deemed to be inclusive of transportation of tools and equipments as required to the site of work and removing the same after completion of work ii verticality test of the tube well structure shall be carried out and the cost of the same shall be deemed to be included in unit quoted rate, excavation in trenches not exceeding 15 metre wide and not exc 15 metre in depth for foundation of pole stay or cable trenches and getting out in soft disintegrated rock complete all as specified and as directed by the engineer in charge, returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm in soft loose soil complete all as specified and as directed by the engineer in charge, removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 15 metre above the starting point all as specified and as directed by the engineer in- charge, sf cpvc ball valve of size 20 mm dia suitable for cpvc pipe incl necessary fittings and taking down old one complete all specified and directed make supremeeurotech astralsfmc, supply and fix in trenches high pressure cpvc pipes sdr-135 plain cpvc sdr 11 fittings including all necessay fittings solvents of size 40 mm dia complete including taking down old one all as specified and directed make supremeeurotech astralsfmc, supply and fix in trenches high pressure cpvc pipes sdr-135 plain cpvc sdr 11 fittings including all necessay fittings solvents of size 20 mm dia complete including taking down old one all as specified and directed make supremeeurotech astralsfmc, m l for replacement of foot valve 4050 mm dia pipe complete including taking tp suction lines from up sump of depth max up to 50 mtrs and lowering after replacemnt of foot valve complete all as specified, m l for replacement of foot valve 80 mm dia pipe complete including taking tp suction lines from up sump of depth max up to 50 mtrs and lowering after replacemnt of foot valve complete all as specified, m l for road cutting hard standing for width not less than 30 cm and not exceeding depth up to 45 cm for laying of pipe lines and making good to road hard standing area with necessary cement concrete complete all as directed, sump of capacity 1 00 000 gln at main pump house and g13, sump of capacity 50 000 gln at main pump house offs md accn area swimming pool, sump of capacity 40 000 gln ward room mess, sump of capacity 25 000 gln at dsc civ md accn, oht of capacity 50 000 gln at family qtr oht, oht of capacity 75 000 to 1 00 000 gln at eklavya, oht of capacity 5000 gln at near mi room auditoriummysure block, sump of capacity 1 75 000 gln at new nwc, ml for cross arm bracings support clamps and back plates fabricated from structural steel section including nuts bolts washer welding drilling hole for bolts bending in any shape or size as indicated or directed and inclusive of one coat of aluminium primer one under coat and one finishing coat of aluminium paint for for repair repalcement of portion of existing ladder at oht as per existing specification frame cover for valve chamber etc complete all as specified and as directed, m l for dismantling cross-arms of ms channel or angle sections etc complete and setting aside for re-use with in 50m, ml for earthing complete with galvanised steel earth plate electrode 600 x 600 x 60 mm thick burried directly in gorund earth pit not less than 225 mtr normal ground level and top edge of earth plate not less than 15 mtr below normal ground level using galvanised iron strip 254mm as earthing lead with bolts nuts check nuts and washers of galvanised iron protection pipe light grade of 40 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt watering funnel with wire mesh earth pit chamber and cover ci frame pcc 136 type c-2 all as shown in electrical plate no-3 of ssr part-i of 2009 connected to earthing test point all as specified and indicated including all earth work excavation returning filling and disposal of surplus soil and testing on completion, supply fix and testing smart digital 10-levels indicator stage type with mechanism to detect display the water level in an underground overhead tank fixed on wall oht with necessary pvc corrosion free enclosure corrosion maintenance free magnetic sensors buzzer alarm sounds on low high levels including necessary fittings on sensing the water level from oht of height up to 21 mtrs ug sump of depth at 60 mtrs complete make sinetrac, m l for testing of water samples from sourceinside the ins mandovi from ohtsumpbore wellsany service tanks and testing in govt lab govt approved pvt labs for bacterial and chemical testing of water sample to find out the total coliforms e coli faecal coliforms ph nitrates nitrates and turbidity complete including taking the samples in every qe as and when required as directed by engineer in charge note the m l for collection of samples including new container as per lab standards transportaion cost up to lab is included in unit rate, supply fabricating installation in replacement self illumnated acrylic led sig board factory made with fixed on wall iron frame as directed letter length 30 cm max up to 40 cm letter thickness 5 cm max up to 6 cm customized design of letters back-lit signage including embedding the signage baord firmly with the wall ms angle frameas per approved art work and nomenclature as given below - note nomenclature of sign board include letterslogos etc complete as directed box with frame - 25 x 25 mm square pipe 18 g frame with cross supports spacing not exceeding 10 m on the box length including 20 mm x 20 mm ms square pipe 18 g stifferenrs duly white enamel painted in 2 coats over a coat of zinc oxide iron primer depth of box should not be less than 165 mm side top back and bottom panels - made out of 24 gauge chemically treated gi sheets duly precoated powder coated with white matt finish coating on both inner and outer surface top panel to have 24 guage precoated drip cap fixed with pop rivet or machine moulded to shape of 25 mm on front and side to prevent damages due to rain etc the bottom panel should be provided with access door fixed with ss screws and suitable housing for led drivers led module - led 12v module beam angle 150 degrees with ip rating 64 072 w70 lumens per module of 3 leds with 7000 to 8000 k colour temperature make tridonic osram cree ge led configuration - 29 led modules per sq mt equal division on spacing based on height of box and one module every 020 m on running length of box led power supply - input 230 v ac power supply should be cpcc constant power constant current of 30w60w120 w each graphics - graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation, m l for servicing of filtration plant at water supply installations including removing the existing gravels in sand filter complete painting of filtration plant including replacing unserviceble nuts bolts of cover plate complete note work shall be done through the reputed firm sandgravepubbles required for replacement is measured and paid seperately under respective items, supply and fill in replacement pabbles size 1 15 mm in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, supply and fill in replacement pabbles size 1 - 34 mm in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, supply and fill in replacement pabbles size 34 12 mm in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, supply and fill in replacement corese siliex size 12 14 mm in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, supply and fill in replacement corese siliex size 14 110 mm in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, supply and fill in replacement graded sand in sand filter including getting out from the filter all as per specified and directed by engr-in-charge, m l for surface excavation at water supply installations not exceeding 30 cm deep and averaging 15 cm deep and getting out soft loose soil removing shrubs small trees height up to 10 mtrs removing the grass from route as directed note i rate includes removing all waste material and grass not excceding 250 mtrs distance from installation depositing where directed at a level not exceeding 15 mtrs above the starting point and cleaning of yard complete all as specified and directed by eicii repeated cleaning in each installation shall be measured and paid seperately with time interval of minimum 2 months, m l for laying of weed control mat sorrounding area of over head tank ug sump insid ethe water supply installations of size thickness less than 100 gsm ans size 1012 x 100 mtrs of roll laid in level surface with 7 inch 18 cm high quality pvc nails for firm hold for weed mat at earth surfaces in regular intervals in between 5 mtrs complete alla s specified and as directed, supply and fix fire retardant insulated synthetic mat for lt 1100 volt of 20 mm thick - 10 conforming to is tested for breakdown strength ageing properties insulation resistance effect of acid alkaline diesel transformer oil leakage current test fire test etc having the width of 1000mm -20mm complete as required sutable and using adhasive and alied chemical and scaling of all part s of all joints and border ends and fixing tape making good as paste near lt panel boards complete all as specified and as directed make vardhamanjyothicease fireqquivalent, s f junction box made from smcfrp sheet ready made of size300x 200x105 mm with aluminium bus bar of 100 amp capacity for ryb and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ms sheet steel fixed inside the bottom portion of box to connect the cable gland complete entire assembly fixed to pole wall with ms clamp 25 x 5 mm and nuts bolts or inside the copping of pole post top including mcb sp 6 amp 10 ka 240 v - 1 no with necessary size copper lugs for connecting cables from junction box to fittings complete all as directed by engineer-in-charge make sintex right hingedhensal, s f lt feeder piller box 20 mm thick oin door type cpri approved with 100 amp copper bus bar for ryb and neutral with necessary control wiring consisting of following - incomming mccb 100 amp 4 pole 16 ka - 01 nos multi function meter for v-a-f -01 nos indicating lamp for ryb - 01 set out going mcb tpn - 32 amp - 02 nos mpcb 20 - 25 amp with ol sc and single phase preventer - tpn 32 amp 10 ka - 02 nos fully automatic starter for 10 hp pump motor - 02 nos curent transformer 20 25- 5amp - 06 nos push buttonfor startstop - 04 nos led indicating lamp onoff trip - 06 nos mcb 6 amp - 02 nos note i panel shall be floor mounted inside the pump house ii minor variation in range of starter mpcb ct shall be selected as pe the make approved, supply and fix in replacement hdpe pipe of pressure rating 6 kgf sq cm of size 50 mm inner dia in bore well including all necessay fittings like elbow tee socket reducer bushings step over bends end caps end plugs etcand with including taking up old unserviceble gi pipes pipes complete all as specified and directed by engineer in charge make supremeeurotech astralsfmc, sf pvc insulated pvc sheathed stranded copper conductor as in flat submersible water proof cable of size 16 sqmm 3 core 1100 volts grade incl taking down old one complete as specified and directed, sf pvc insulated pvc sheathed stranded copper conductor as in flat submersible water proof cable of size 10 sqmm 3 core 1100 volts grade incl taking down old one complete as specified and directed, sf pvc insulated pvc sheathed stranded copper conductor as in flat submersible water proof cable of size 6 sqmm 3 core 1100 volts grade incl taking down old one complete as specified and directed, sf pvc insulated pvc sheathed stranded copper conductor as in flat submersible water proof cable of size 4 sqmm 3 core 1100 volts grade incl taking down old one complete as specified and directed, m l for painting of incoming and outgoing pipes of oht sumps with standard colour code for ci pipe of sixe 100150 mm dia complete all as specified, m l for ms pipe of sise 150 mm dia with necessary bend tee weldding as required at size including necessary fittings to join with existing gici pipe lines complete all as specified and as directed, m l for ms pipe of sise 100 mm dia with necessary bend tee weldding as required at size including necessary fittings to join with existing gici pipe lines complete all as specified and as directed, m l ci fitting for bends any type radius and angle tapers any type straight bend increasing decreasing or double socket etc tee pieces single branch y junction double branch cross flange sockets or socket and spigot collars caps and plugs all complete all as specified and as directedsize up to 150 mm bore, sf in replacement butter fly valve in any positionof size 150 mm dia including rubber gasget nut bolts washers including taking down unserviceable valve complete all as specified and directed, sf in replacement nrv in any positionof size 100 mm dia including rubber gasget nut bolts washers including taking down unserviceable valve complete all as specified and directed, sf in replacement nrv in any positionof size 80 mm dia including rubber gasget nut bolts washers including taking down unserviceable valve complete all as specified and directed, sf in replacement nrv in any positionof size 65 mm dia including rubber gasget nut bolts washers including taking down unserviceable valve complete all as specified and directed, sf in replacement nrv in any positionof size 50 mm dia including rubber gasget nut bolts washers including taking down unserviceable valve complete all as specified and directed, supply fixing in and replacement of unserviceable automatic pressure switch for 1 hp to 2 hp booster pump all as specified and as directed, supply and fixing in replacement of surge tank booster tank suitable for booster pump including taking out the old one all as specified and as directed, supply and fixing in repalcement of manifolder connector asswembly for booster pump 5 way suitable for booster pump including taking out the old one all as specified and as directed, supply and fixing in repalcement of non return valve 25 mm for booster pump complete all as specifed and as directed, supply and fix in replacement of pressure gauge 0-5 kg cm2 for booster pump complete all as specified and as directed, supply and fix in replacement of motor of capacity 07510 hp for booster pump complete all as specified and as directed, supply and fixing of pressure booster pump 05 hp 10 hp 037kw 075kwrated voltage 220v voltage range 180v-260v 1ph rated frequency 50hz pipe size 25mm x 25mm max head up to 55 meters max discharge up to 4280 lph provided stainless steel insert for corrosion free stuck free operationhigh suction capacity instant suction up to 80 meters suction lift high grade brass impeller high grade electrical stamping reduces electrical losses improves pump effciencyeasy for maintenance make kirloskar crompton greaves havells, m l for dismantling of existing damaged valve pit complete and costruction of new brick masonary valve pit chamber of size 600 x 600 x 600mm internaldimensionincluding pcc brickwork and ms sheet cover 20 mm thick ms angle iron frame size 25mm x 25mm x 6mm around of valve pit locking arrangement with painting all steel surfaces with two coats of sythetic enamel paint over a coat of red oxide primer complete all as specified and directed, supply and fix in replacement panel mount digital voltmeter 0-500 volt complete, supply and fix in replacement panel mount digital ammeter 0-50 amp complete, supply and fix in replacemnet led type indicating lamp complete, supply and fix in replacemnet cts 50 5 amp complete, supply and fix in replacemnet cts 100 5 amp complete, yield test for the existing bore well by continuously pumping for 16 hours to determine safe pumping yield and submit the test report, ml for structural steel channels pcc foundationbase frame for motor of capacity upto 10hp including nuts bolts washer welding drilling hole for bolts bending in any shape or size as indicated or directed and inclusive of one coat of aluminium primer one under coat and one finishing coat of aluminium paint etc complete all as specified and as directed, ml for structural steel channels pcc foundationbase frame for motor of capacity 40hp50hp including nuts bolts washer welding drilling hole for bolts bending in any shape or size as indicated or directed and inclusive of one coat of aluminium primer one under coat and one finishing coat of aluminium paint etc complete all as specified and as directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
comprehensive maintenance of electrically operated washing machine make nat steel equipments 50 kg capacity front loading type steam heating arrangement auto controlled with electric motor 3 ph 415 v 5 hp including maintenance of electrical control panel door seal door locking arrangement maint of shaft pulley inner drum descaling of inner drum and connected pipelines including replacement of all minor spare parts adjustments lubrication etc except major items mentioned hereafter in boq complete all as specified and directed 5 nos machine for a period of 6 months, comprehensive maintenance of electrically operated hydro extracting machine 25 kg capacity make nat steel equipments xsoni system auto controlled with elect motor 3 ph 415 v 5 hp including maintenance of complete electrical control panel door seal door locking arrangement leg spring inner drum when plant is running complete including minor spare partsadjustments lubrication except major items mentioned hereafter in boq complete all as specified and directed 4 nos machine for a period of 6 months, comprehensive maintenance of electrically operated hydro extracting machine 50 kg capacity make nat steel equipments xsoni system auto controlled with elect motor 3 ph 415 v 5 hp including maintenance of complete electrical control panel door seal door locking arrangement leg spring inner drum when plant is running including minor partsadjustments lubrication except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maint of air compressor 10 kg per cm 2 capacity make l-hg khosla including minor repairs and topping up of mobil oil periodically approx 5 ltrs including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of pneumatically operated steam heated auto temperature controlled flat bed press of size 750 x 1500 mm make xsoni system including cleaning of padding cloth descaling of steam pipeline including replacement of all minor spare partsadjustments lubrication including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 3 nos machine for a period of 6 months, comprehensive maintenance of steam boiler oil fired type fully automatic of capacity 600 kghour having fuel pump motor 3 ph 415 v 2 hp thermax model rxa-6 including overhauling of pump set tuning of pumps lubricating cleaning of head chimney using iron brush cleaning of economiser etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of electrically operated front loading sluice machine make nat steel equipments 15 kg capacity auto controlled having separate electric motor 3 ph 415 v 2 hp 3 hp washing and extraction including maintaining of complete electrical control panel shaft pulley door seal locking arrangement etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 3 nos machine for a period of 6 months, comprehensive maintenance of calendering machine make snow white roller type of size 24 x 3 incl testing of steam valve lubricant of gear system adjustment of chain pneumatic valve replacing of twin threads descaling of strainer including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of drying tumbler end loading type of capacity 25 kg make nat steel and 50 kg make-xsoni system including aligning lubricating and cleaning of gear monthly etc including replacement of all minor spare parts except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of autoclave machine at ot including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 2 nos machine for a period of 6 months, comprehensive maintenance of autoclave machine at cssd including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required sizeexcept major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of dry cleaning machine at laundry including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, comprehensive maintenance of sterilizer machine at laundry including minor repairmaintenance and adjustment minor parts like- ss bolt nut glass braided wire of required size except major items mentioned hereafter in boq complete all as specified and directed 1 no machine for a period of 6 months, ml for rewinding of electric motor induction 3 ph 415v 50 cs 5 hp capacity with suitable size of copper wire as per existing and insulating materials heat varnishing including replacement of ball bearing 2 nos as per existing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 3 hp capacity with suitable size of copper wire as per existing and insulating materials heat varnishing complete including replacement of changing of ball bearing 3 nos as per existing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 2 hp capacity with suitable size of copper wire and insulating materials heat varnishing complete all as specified and directed, ml for rewinding of electric motor induction 3ph 415v 50 cs 1 hp capacity with suitable size of copper wire and insulating materials heat varnishing complete all as specified and directed, opening the top cover of boiler and all connecting fittings and taking out top cover incl defective refractory and cleaning for the boiler descaling of steam coil by suitable descaling compound and re fixing the top cover by replacement suitable size nuts bolts as asbestos rope packing etc complete all as specified and directed, photo cell, diffuser plate-stud, nozzle 6-5 gph 450 degree, packing-asbestos, packing-hylam, electorde-bush, ignition electrode-rod each set, hose pipe braied dia 1 as per samle, ignition electrode -cap -api 15017170, wegman cone - dia 250 - h, belt v- belt as pe sample- a 56, pid control-selec-tc-513ax-ns207- ip-rtdtc 1coc rly 1sp 48x48, pr switch -01 to 11 bar, pr gauge brdn-wpcpb - 0-25 kg d100 38 bspt pcb, pr gauge ksch-rfm 4 rb63 0-4 bar d63 rp 14 bt, ign trans-230 vct-145kv 500va, pr switch -1 to 16 bar, diffuser plate -dia 136- rx-06, sp-dkolb water pump -triplex capacity-2160 lithr rpm 950 triplex make-dampt kolben or equivalent as approved by ge, gear pump oil pump as per existingsample, sequence controller with ase ma 810 as per existingsample, fuel pump aj6ac poif 510030 for boiler, safety valve as per existingsample, 20 mm non return valve as per existingsample, stop valve flange type as per existingsample, top refractory as per existingsample, removing heavy weight steam coil from the boiler shell establishing leakage damage of existing coil by hydraulic test replacing with new heavy weight steam coil makesagar for replacing worn out defective fittings including heat proof metallic gasket makechampion brand and testing on load of two hours installation testing and commissioning complete all as specified and directed, st suction en 05-15, oil filter en 5-15, st separator en 5-15, air tube xp5l, st solenoid 2-1524 ac, compressor oil, add-on block no-nc, push button, indicator light led, dtc temp, solenoid valve, pneumatic valve, pneumatic gland, dtc timer, bed spring heavy and high tension, pillow block bearing ucp-211 make - nat steel, pillow block bearing ucp-509 make - nat steel, oil seal as per existingsample, roller micro switch, steam stop valve 25 mm 20 mm make neta or equivalen, overload relay as per existingsample, ci pulley as per existingsample, main drive ci pulley as per existingsample, v belt no b-59, v belt no b-60, gland packing, for hydro big, for hydro small, descaling of stainless steel drum by proper descaling compound to remove scale from the perforated body for proper cleaning of cloth and economy usage of steam complete all as specified and directed, sf in replacement limit switch for washing machine sluicing machine drying tumbler calendering machine hydro extractor boiler autoclave machine as per existingsample complete all as specified and directed, contactor 9 amp, contactor 18 amp, contactor 25amp, contactor 32 amp, oil seal as per existingsample, brake shoe assembly complete with liner as per existingsample, ci pulley as per existingsample, door gasket as per existingsample, main shaft as per existingsample, v belt as per sampleb-68 and a-58, leg shaft as per existingsample, ball bearing as per existingsample, hydro balancing spring, hydro rubber buffer, hydro balancing spring bush, collar bush, belt adjusting clamp, sf in replacement inner ss drum for 25 kg hydro extractor - as per existingsample make -nat steel complete all as specified and directed, electric heater 1 kw fin type as per existingsample, v belt as per sample belt no-b-75 b-94 a-64, ball bearing as per existingsample, timer 0-60 min, push button with nonc, dtc, add-on block no-nc, blower fan, door gas kit, teflon wire 10mm, electric heater 15 2 kw fin type as per existingsample, pneumatic on of valve, 14 double pilot air valve incl fittings, v belt as per sample belt no-b-36, add-on block no-nc, push button, indicator light led, solenoid valve, air pipe, tongal switch, vspd 2, feeding belt, guide belt moq, padding, steam steel hose pipe 1 inch, air solenoid valve, namda cloth, sf in replacement ball valve of size 50 mm dia as per existingsample complete all as specified and directed, cleaning of underground dlpp tank of 5000 ltr capacity by removing the accumulated dirt with scraper iron brush etc complete all as specified and directed, cleaning of oh dlpp tank of 500 ltr capacity by removing the accumulated dirt with scraper iron brush etc complete all as specified and directed, door gasket of suitable size as per existingsample make nat or equivalent, door start pine, heating element 6kw make nat or equivalent as per existingsample, channel jacket pipe, 12 ss connector male thread, 12 ss connector female thread, boiler gasketnew type, float switch, float switch gasket, door hub part no-84199090, door handlebig part no-84199090, diaphragm plate part no-84199090, diaphragm gasket part no-84199090, solenoid valve 15mm complete set steamline make-avcon or equivalent as approved by ge, solenoid valve 20 mm complete set waterline make-avcon or equivalent as approved by ge, solenoid valve 25 mm complete set waterline make-avcon or equivalent as approved by ge, door bracket pin, sensor adjustable 20 mm bsp6make- simplex, relay card for autoclave machine, ball valve 15 mm, ball valve 20 mm, alane key bolts as per sample, v belt as per existingsample, ball bearing as per existingsample, door gasket, ml for fabrication of ms base made of ms channel of size 50 x 100 mm 6 mm thickness and length 12 to 15 m including reinforcement as per direction and grouting 04 nos bolts of size 58 x 6 long including the taking out old unserviceable existing base with washing sluicing machine and fixing new base frame with installation washing machinesluicing machine including necessary cement work including with dismantling of old worn out base plate complete all as specified and directed, ml for opening of chimney at both end of boiler and central exhaust system cleaning of shunt carbon from both end of central exhaust system of both the boiler chimney including replacement of gasket nut bolts complete all as specified and directed, sf in replacement ss door lock for washing machine complete all as specified and directed, ml for repairs to hydro extractor by replacement of bright rod with nuts for foundation base frame - 03 nos grouting bolts nuts - 03 nos repair of main ss drum - 01 no pulley shaft - 01 no foundation frame with necessary machining work as per site requirement - 01 no 03 hp motor hanger as per attachment - 01 no complete brake shoe assembly - 01 no leg shaft - 03 nos gm main check nut of centrifugal ss drum - 01 no and necessary repairs of ci housing if required and assemble all parts and balancing ss centrifugal drum after disconnection of electrical as well as mechanical connections etc and re-installing the complete hydro extractor along with reconnecting all electrical connections and mechanical connection after performing a test load for 1 hour complete all as specified and directed, ml for descaling of ss boiler tank of autoclave machine by opening of drum removing of old worn out steam gasket and ss nuts bolts and taking out all heating elements along with disconnecting electrical connection complete and descaling the tank with proper descaling agent refixing of all electrical connection and heating element and also replacing diaphragm gasket and other necessary steam gasket ss nuts bolts testing complete twice in a year complete all as specified and directed, supply and fix in repairs after taking down the old unserviceable one mcb spn up to 32 amp 10ka breaking capacity 230240 volt ac as specified and directed make- legrand cat no-4085 28 to 4086 36 or equivalent model of indoasian havells l t, sf in replacement mcb sp 6-32 amp c curve 10ka breaking capacity 230240 volt ac complete all as specified and directed, 25 mm bore, 40 mm bore, 80 mm bore, 20 mm bore, 25 mm bore, 50 mm bore, sf in replacement single phase preventer auto reset 50 v unbalance complete all as specified and directed make minilec cat no vsp3 or equivalent as approved by ge, suppyly only dry cleaning machine chemical tetrachloroethylene perchloroethylene perc complete all as specified and directed, vacumm pump lx-2 3 hp, air compressor st v belt xpz 108t, st interface valve net en11, drain valve assembly wi04ggas valve w2, sf in replacement of out dia connector of ss drain of washing machine of both end including shaft as per existingsample with complete fabrication and foundation complete all as specified and directed, sf padding for hydraulic press complete all as specified and directed, sf in replacement air exhaust system for dry cleaning machine complete all as specified and directed, sf in replacement temperature to frequency convertor for steriliser machine complete all as specified and directed, sf in replacement door frame with heatproof glass and heat proof gasket for dryer complete all as specified and directed, ml for complete overhauling and repairs of high-pressure triplex reciprocating boiler feed water pump scope includes dismantling the pump assembly replacement of worn-out eccentric shaft main bearings high-pressure plungers fluid-end suctiondelivery valve kits v-packings and oil seals item includes crankcase oil replacement re-coupling alignment with motor and pressure testing at rated boiler operating pressure to ensure leak-free performance complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
ml for disconnecting carefully electrical connection from both ht lt primary secondary sides of the transformer keeping them at safe side and taking the transformer out from the plinth with the help of crane indoor outdoor type of capacity 500 kva to 800 kva 11 kv 0433 kv step down any make for carrying out complete overhauling which shall comprise of the following- a ml for lifting transporting handling the transformer to workshop and opening top cover of the transformer by unscrewing nuts bolts washers etc including disconnecting core assembly from ht lt bushing and lifting the same gently and taking out from the shell container body of the transformer b ml for draining out transformer oil from the above said transformer in the suitable capacity of container drums and keeping it in safe custody for reuse c ml for cleaning the transformer body from inside removing deposited dirt sludge foreign particles etc from the bottom body of the transformer with appropriate chemical solution and drying up the shell from inside before refilling of the transformer oil d ml for cleaning and washing thoroughly core and windings of the transformer by hosing down with clean dry oil conforming to is 3351983 removing deposited dirt sludge foreign particles from the windings core thorough inspection of windings providing insulations to leads and terminals heating drying baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as specified and as directed by engr-in- charge contd, all as per item no 200 above but transformer voltage stabiliser indoor outdoor type of capacity up to 250 to 400 kva, all as per item no 200 above but transformer voltage stabiliser indoor outdoor type of capacity up to 100 to 200 kva, filtration dehydration of transformer oil of transformers frmus installed at various locations to achieve di-electric strength not less than 60 kv at 25mm gap as per relevant is with portable filtration plant testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the engineer-in-charge, supply and topping up of transformer oil with di-electric strength not less than 60 kv into the conservator tank body tank of the transformer ocb frmus etc at various locations complete all as directed by the engineer-in-charge, ml for rewinding of distribution htlt transformers of capacity 500 to 750 kva type by winding the defective coils with new copper wire as per is of same gauge and existing size together with new insulated materials bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber testing and commissioning the transformer and recording the test results complete all as directed note ml for re-insulation of serviceable coils will be measured paid separately under relevant items, all as per item no 700 above but rewinding of distribution htlt transformers of capacity 100 to 400 kva type, ml for re-insulating windings of ht lt distribution transformers of capacity 100 to 750 kva by strip opening of ht lt coils ie primary secondary coils from core assembly safely unwinding the ht lt coils ie primary secondary coils complete removing the old defective insulation paper and replacing with new dpc insulation to the copper conductor re-varnishing of the windings with super varnish including heating drying backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as directed by engr-in- charge, disconnection of the distribution transformer of capacity 100 to 800 kva from ht and lt supply mains removing of bus duct and bus bar leakage arresting by draining out of oil after arrangement of necessary empty oil drums buckets etc dismantling of top cover and accessories dismantling of lt bushings by disconnecting leads jumpers from inside replacement of gaskets and oil seals and re fixing of the lt bushings making internal and external connections replacement of cover gasket and accessories reassembling of acessories and cover filling back of existing transformer oil complete and making cable connections and assessing for energising the transformer complete all as specified and as directed note i the rate quoted shall include cost of materials like gaskets and oil seals and labour etc ii bushing and bushing rods shall be measured and paid separately, disconnecting the htlt connections of transformer of capacity 100 to 800 kva ie bus duct cable bunch keeping all the cables out from the htlt sides physically checking the transformer for healthiness performing the transformer tests like hvlv meggar test ratio test magnetic balance test and short circuit tests for checking condition of transformer complete all as specified and as directed note- i all testing shall be done in presence of engr-in-charge or his accredited rep and test reports shall be signed by contractor and engr-in-charge and kept on record ii if the transformer found satisfactory then htlt connections shall be done by the contractor and has to charge the transformer iii if the transformer fails in these tests then the contractor has to shift the transformer for winding overhauling which will be measured and paid separately iv cost of winding overhauling if required shall be measured and paid separately, shifting the transformer of capacity 100 to 800 kva from existing site to another site within 3 km distance range by dismantling of ht and lt cable connections jumpers and busbars including lt busbar cable boxes and closing the transformers for loading into transporting vehicle with the help of crane transportation to another site unloading cable connections both ht and lt testing and commissioning complete all as specified and as directed, ml silica gel breather assembly complete suitable for 200 to 800 kva transformer as per existing with breather unit and silica gel including connecting with proper necessary gaskets of necessary including taking down existing unserviceable breather assembly complete all as specified and as directed, sf conservator tank assembly suitable for transformer of capacity 200 to 800 kva as per existing and including connecting properly with gaskets of necessary including taking down existing unserviceable conservator tank assembly complete all as specified and as directed, sf gun metal drain valves suitable for transformer of capacity 200 to 800 kva including taking down unserviceable gun metal drain valves complete all as specified and as directed, sf off load tap changer assembly suitable for transformer of capacity 400 to 800 kva as per existing with 7 tapping position including opening top cover conservator etc including taking down existing unserviceable off load tap changer complete all as specified and as directed, sf wti winding temperature indicator suitable for distribution transformer of capacity 400 to 800 kva as per existing including taking down existing unserviceable wti complete all as specified and as directed, s f lt bushings made out of porcelain along with bushing rod made out of brass copper as per existing and suitable for distribution transformer of capacity 500 to 800 kva including taking down existing unserviceable lt bushings and complete all as specified and as directed, s f ht bushings made out of porcelain along with bushing rod made out of brass copper as per existing and suitable for distribution transformer of capacity 500 to 800 kva including taking down existing unserviceable ht bushings and complete all as specified and as directed, sf oil gauge glass with gaskets as per existing suitable for distribution transformers of capacity 500 to 800 kva including including taking down existing unserviceable oil guage glass with gaskets complete all as specified and as directed, ml for preparation of old exposed painted surfaces of indoor outdoor type transformer of capacity 500 to 800 kva and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth base with white synthetic enamel paint on black synthetic enamel paint back ground complete including one coat of white wash on exposed surface of transfomer plinth base complete all as specified and as directed note - colour code of paint shall be as decided by engr-in-charge, sf oti oil temperature indicator as per existing suitable for distribution transformers of capacity 500 to 800 kva including taking down existing unserviceable oti complete all as specified and as directed, ml drain plugs to valvesconservator caps of the sizes 34 1 15 valves and plugs as per existing suitable for distribution transformers of capacity 100 to 800 kva including taking down existing unserviceable drain plugs to valvesconservator caps complete all as specified and as directed, clearing away all bushes small plants grass vegetation saplings shrubs brushwood undergrowth roots upto root level including surface dressing nexc 15 cm deep around and surroundings areas of em installations ietwo pole four structures outdoor-substation yards pump house misc em installations etc and removing rubbish debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed, supply and laying hardcore of aggregate using 20mm graded crushed stone aggregate deposited spread and leveled in layers watered and rolled rammed to a true surface in sub-station yards complete all as specified and directed note - thickness of aggregate shall be measured after compaction, excavation in trenches not exc 15 m wide and not exc 15 m in depth for foundation etc or for shafts wells cesspits manholes pier holes etc n exc 10 sq m on plan and n exc 15 m in depth and getting out in soft loose soil complete all as specified and directed, returning filling in trenching with soil and including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed, removing of excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 15 m above the starting point complete all as specified and directed, ml sand cushioning with clean dry river sand in trenches for protection of ug cable or in sub-station yards including punning down complete all as specified and directed note- punned thickness of sand cushioning shall only measured and paid, supplying and laying un-reinforced precast concrete cable cover class hv type 1 flat of size 300mmx 180mm x 40mm cable covers as protection to cable in trenches including taking down existing unserviceable cover of any description complete all as specified and directed, sf 100 mm bore dia galvanised steel tubing light grade laid under road crossing for cable protection or fixed to poles walls or laid under floors including taking down existing un-serviceable pipe of any description complete all as specified and directed, ml cable jointing kit for 11 kv earthed grade 3 core xlpe armoured aluminium conductor cable of size 120 to 185 sqmm for outdoor end termination heat shrink type joint with jointing material and accessories including taking out unserviceable cable joint kit complete all as specified and directed, all as per item no 3200 above but for cable of size 240 to 300 sqmm, ml cable jointing kit for 11 kv earthed grade 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for straight through heat shrink type joint with jointing material and accessories including taking out unserviceable cable joint kit complete all as specified and directed, all as per item no 3400 above but for cable of size 240 to 300 sqmm, supply laying xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty with aluminium conductor 11000 volts earthed grade cross sectional area 185 sqmm 3 core laid in trenches duct on pole on wall including taking out existing unserviceable cable complete all as specified and directed, all as per sl item no 3600 here in before but cable of size 240 sqmm x 3 core, ml for detecting ht 11kv ug cable faults located in any stretch depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system hv surge generator fault pin point surge wave receiver cable identification instrument cable tracer for exact location of under ground cable routes complete all as directed note- the rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment transportation of equipment charges for service engineer, ml for repair and servicing of ht 11 kv four pole structure by replacing aluminium pg clamps gi bolts and nuts pieces of acsr conductor with insulation sleeve ryb of any size as jumpers including lubricating the moving parts of ab switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust salt deposits over surfaces including preparation of surfaces applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as specified and as directed note rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces of structure, all as per sl item no 3900 but for two pole structure, servicing inspecting checking cleaning by using of blower lubrication greasing and carrying out preventive maintanance of rmu of capacity 11 kv 250 350 mva including calibrating the relay by conducting secondary injection tests and rmu in serviceable condition testing and commissioning all as specified and as directed by the engineer-in-charge notes unit rate quoted shall be deemed to include cost for necessary tp nuts bolts washers gasket insulation tape compound painting of rmu panels with approved colour including lettering details all as per exisitng, sf in repair self powered relay with oc sc ef protection having front usb port for laptop interface lcd display 10 event records 5 fault records min 2 setting group and keypad for setting parameters for the relay complete suitable for rmu of capacity 250350 mva all as specified and as directed, sf in repairs current transformer ratio - 100-501-1a accuracy class 10 burden - 25va for metering and class 10p10 25 va for protection complete all as specified and directed, sf in repairs cable termination bushing suitable for upto 1 run 3 core x 185 sq mm xlpe cable complete all as specified and directed, sf in repair cable termination cover boots push on type suitable for rmu of capacity 250350 mva complete all as specified and directed, sf in repair phase indicator lamps red yellow and blue suitable for rmu of capacity 250350 mva complete all as specified and directed, sf in repair 11kv 230v ac 1kva control transformer suitable for rmu of capacity 250350 mva complete all as specified and directed, sf in repair battery with and including battery charger 12ah ip-230v ac op - 24v dc suitable for rmu of capacity 250350 mva complete all as specified and directed, sf in repair spring charging motor suitable for rmu of capacity 250350 mva complete all as specified and directed, disconnection of 11 kv ht cables from 11 kv rmu upto 6 way and shifting transportation of 11 kv rmu to oem workshop to and fro for repair sf6 gas filling as required including connections after repair all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv rmu sf6 switchgear assembly in repair all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv rmu vacuum switchgear wiring including any type of buttons etc including connection with metering unit all as directed by engineer-in-charge, ml for sf6 gas refilling for 11 kv rmu upto 6 way by oem all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv dual core dual ratio current transformer of ratio 200-1001-1a ci 10-5p10 all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv resin cast insulators with copper studds of 630 amps copper conductor as per existing rmu all as directed by engineer-in-charge, ml for insulation coating painting inside rmu cable and vcb chamber of rmu all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv idmt relay dual powered - self and aux powered type of siemens make model no siemens 7sr45 in repair all as directed by engineer-in-charge, supply fixing testing and commissioning of 11 kv vacuum interuppter suitable for 630 amps rmu as per existing vg1vg2 or eqvlt rmu all as directed by engineer-in-charge, sf in repair danger notice plate of size 25 x 20 cm 16mm thick mild steel sheet vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with ms clamps bolts and nuts of approved size for ht compete all as specified and as directed, sf in repair disc insulator porcelain vitreous brown 145 mm height 255 mm dia ball and socket type two in series assembly with cast aluminium 4 u bolt tension hardware and tension clamps for conductors working pressure ht 11 kv complete all as specified and as directed, sf in repair for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut for 11000 volts grade 150 mm dia 150 mm height complete all as specified and as directed, sf switches air break gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 amps 11000 volts all as per clause no 1969 of ssr part-i 2009 including taking down existing unserviceable god complete all as specified and directed, sf in repair drop out lift off ht 11 kv 200 amp fuse link consisting of channel iron base having 2 nos 11 kv post type insulators in stack 2 stack per phase complete with fuse carrier of srbp tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze conforming to is 9385 complete all as specified and directed, ml earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position earth pit not less than 225 m deep below the normal ground level with top edge of the earth plate not less than 15 m below normal ground level connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point including dismantling un-serviceable earthing complete all as specified and directed note- the unit rate shall also include for earth work in any type of soil pcc 136 type c1 chamber rcc 1153 type a1 cover slab 50 mm thick reinforced with 8 mm dia tmt bar 140 mm cc both ways 10 mm dia plain bar lifting handle embedded in cover slab main earthing lead from earth electrode to test point upto 75 m length 20 mm bore medium grade gi watering pipe 40 mm bore gi light grade earth lead protection pipe funnel wire mesh copper lugs charcoal and common salt in alternate layer etc, disconnect and taking out idmt numeric microprocessor based relay of any type make from 11 kv ht panel at p-5 sub stn nad trs-ii cleaning the contacts calibrating the relay by conducting secondary injection tests checking of current transformer rectification of defects in control wiring for proper tripping of circuit breakers through cts and relay and tripping coils adjustment setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping tune synchronise upstream breaker relay settings re-installation of relay testing commissioning etc complete all as specified and as directed note- i arrangement of necessary testing calibration kits testing equipments tools etc shall be done by contractor and cost of the same shalll deemed to be included in the unit rate quoted ii testing tuning shall be carried out in the presence of representative of the accepting officer to the entire satisfaction of the rep of ge, taking down ht switch gear vacuum circuit breaker at p-5 sub stn trs-i trs-ii frcs sub stn at nad of capacity 11 kv 250350 mva comprising of following repairs overhauling servicing carrying out preventive maintenance and refixing the same after repairs overhauling a tripping off the breaker lowering the breaker with raisinglowering handle and pulling out the breaker complete from the panel along with the trolley for servicinginspectionoverhauling b servicinginspectingchecking of automatic safety shutter circuit spout and circuit spout connections for ryb phases and replacement of spares operation for serviceability and replacement of spares if required c dismantling and checking of cross bar assembly fixed contacts and current carrying parts of the breaker trolley insulated assembly and checking lamination with clamps epoxy spout isolator assembly etc d setting reassembling cleaning adjustment of fixed contacts main contact arcing contacts and chamber baffle pot assembly moving contact for proper setting of auxiliary contacts operating mechanism e servicinginspectingchecking of secondary socketsbusbar earthing plugsearthing sockets and replacement of spares if required f checking setting and adjustment of lowering and raising operation of the breaker trolley g decarbonising of busbar and connected items h lubrication and greasing of all moving parts of the trolley stopper bolt for proper operating and closing of shutter gear isolation resistance of trolley of with vacuum interrupter assembly contd, cts epoxy cast wound primary cts with minimum primary current 50 to 100 a double ratio double core protection core-5p10 metering core- class 10 25 ka for 1 sec of 15 va minimum burden, 15 sqmm flexible pvc stranded copper conductor cable unsheathed 1100 v grade for control wiring, 25 sqmm flexible pvc stranded copper conductor cable unsheathed 1100 v grade for control wiring, led indication lamps, shunt trip coil 110 v dc220 v dc, shunt trip coil 110 v dc220 v dc with assembly, breaker control switch, busbar spout, circuit spout, control circuit fuses 2 a to 63 a, hrc fuse pt ht side, vcb buffers, 110 volt dc closing coil assembly, epoxy body, vcb spouts, pole supporting assembly, spring charging motor, bus bar support insulator for vcb panel, vacuum interrupter bottle vg2, ml for replacement of damaged space heater including thermostat in ht vcb 11kv with new one suitable to operate on 110 volts dc supply complete with necessary wiring and control cable with toggle switch and all as directed by engineer-in-charge, ml for applying silicone high voltage insulator coating si-coat 570 rtv solution using electric airless sprayer to the inside surface of cable chamber alongwith busbar chamber of 11 kv indoor vcb panel including all disconnection re-connection of cables etc complete all as specified and directed by engr-in-charge, supply install testing and commissioning of mi-com feeder protection and control relay kw kva pf hz kwh 12 di 10 do one front rj45 port one rear rs485 port for modbus protocol draw out type with ct shorting feature small lcd display feature including taking down old relay of any description complete all as specified and as directed, sf in repair lightning arresters expulsion type complete with all fittings station class discharge capacity 65 kamp suitable for 11 kv complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
disconnecting opening of indoor type vcbsf6 of any description and any make of rating 11 kv 400630800 amps capacity for servicing overhauling taking out and removing unserviceable defective parts including cleaning servicing greasing oiling of the parts inspection overhauling of tripping assembly earth fault release assembly tripping coil auxiliary switch manual motorised spring drive mechanism motor and gear assembly stop bolt assembly main shaft interlocking assembly closing spring assembly etc lubricant to function smoothly and replacement of unserviceable parts with new one refilling sf6 gas cleaning and inspecting through insulators vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealent for electrical contacts to avoid carbon deposits on contact surfaces cleaning all busbar by rubbing and by crc liquid cleaner reassembling the vcb after overhauling servicing and its testing complete all a specified and directed note i replacement of unserviceable parts shall be measured and paid separately under relevent item of sch a as supply only but fixing charges of the parts replaced repaired is deemed to be included in the item rate ii servicing shall be got carried out by the authorised rep of the vcb manufacturer and the service engineer will submit a service report and calibration certificate for each vcb iii any item not included in ca and required for successful operation of the panel will be provided by the contractor same shall deemed to be included rate quoted iv test report of all parameter duly signed by garrison engineer contractor and engineer-in-charge shall be maintained on records, isolating contact assembly 400630800 amps suitable for 11 kv400630800 amp vcb panel and for rmu, tnc switch for 11 kv vcb panel and rmu, indication lamp led type suitable for 230 volts ac 50hz and 11030 volts dc supply, supply only hrc fuse 11 kv grade 2 amps to 5 amps, supply only hrc fuse 11 kv grade 10amps to 20 amps, vacuum interrupter suitable for 400630800 amps 11 kv ht vcb rmu complete all as specified and directed, motor gear assembly 230v ac suitable for 400630800 amps 11 kv ht vcbrmu including testing puting on load complete all as specified directed, spring bearing gear suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, closing coil assembly 24 volts dc suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, tripping coil assembly 24 volts dc suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, panel door lock suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, auxillary switch 7 no 7nc suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, digital amp meter ct secondary site selectable 5a for 11 kv vcb control panel, digital volt meter for 11 kv vcb control panel, upper connector suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, lower connector suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, support road with screws suitable for 400630800 amps 11 kv ht vcbrmu complete all as specified and directed, sf6 gas, eve er14250 36v 1200mah 12aa lithium battery suitable for relay of schneider rmu, hooter110230vac, ml testing and calibration of 11kv vcbs sf6 indoor type alongwith control panel and control wiring protection system and relays system relay to tripping coil auxiliary switch male and female housing cut outs etc checking the functional status of vacuum interrupter insulation resistances static contact resistance testing ir value ratio test polarity test and connection verification of 11 kv current transformer set of three by primary injection kit and testing and calibration of relay set of two over current and one earth fault by secondary injection kit including all other functional tests of the vcb cr panel and cts pts complete all as specefied and directed note test report of all parameter duly signed by garrison engineer contractor and engineer-in-charge shall be maintained on records, supply and fix in replacement of the over current earth fault feeder protection relay model- easergy p3u30 with 2759505150n46496767n95 protections type- p3u30-6aba1bdaa relays make schneider electric with instant tripping system suitable for voltage 18 to 52 v dc 75 to 250v ac supply 50hz including taking out the existing unserviceable feeder protection relay complete all as specified and as directed, supply and fix in replacement of the over current earth fault feeder protection relay model- easergy p3u20 with 2759505150n46496767n95 protections type- p3u20-6aba1adaa relays make schneider electric with instant tripping system suitable for voltage 18 to 52 v dc 75 to 250v ac supply 50hz including taking out the existing unserviceable feeder protection relay complete all as specified and as directed, supplying and fix in replacement of the idmt relays with instant tripping system voltage 18 to 52 v 75 to 250v including taking out the existing unserviceable idmt relay cgi 14n over current relay complete all as specified and as directed, supplying and fix in replacement of the idmt relays with instant tripping system voltage 18 to 52 v 75 to 250v including taking out the existing unserviceable idmt relay cgi 14s self power relay complete all as specified and as directed, ml labour for taking out the existing unserviceable over current earth fault feeder protection relay model- easergy p3u30p3u20 with 2759505150n46496767n95 protections type- p3u30-6aba1bdaa p3u20-6aba1bdaa relays make schneider electric with instant tripping system suitable for voltage 18 to 52 v dc 75 to 250v ac supply 50hz transporting to authorised repair workshop carrying out the necessary repair re-assembling the feeder protection relay of ht vcb and testing commissioning for staisfactory working including replacement of minor spare parts of relay with complete all as specified and as directed, supply and fixing in replacement digital type multi functional meter for all basic energy and power quality parameter like voltage amps frequency pf ke kvar kwh kvah kvarh 230v ac supply etc with built in selector switch square type as required at site flush mounted of existing size complete all as specified and and as directed, disconnecting opening of outdoorindoor type rmu 5way 2lbs 3vcb of any description and any make of rating 11 kv 400630800 amps capacity for servicing overhauling taking out and removing unserviceable defective parts including cleaning servicing greasing oiling of the parts etc and replacement of unserviceable parts with new one refilling sf6 gas reassembling the vcb after overhauling servicing and its testing complete all a specified and directed note i replacement of unserviceable parts shall be measured and paid separately under relevent item of sch a as supply only but fixing charges of the parts replaced repaired is deemed to be included in the item rateitem no 201 to item no220 ii servicing shall be got carried out by the authorised rep of the vcbrmu manufacturer and the service engineer will submit a service report and calibration certificate for each vcb iii any item not included in ca and required for successful operation of the panel will be provided by the contractor same shall deemed to be included rate quoted iv test report of all parameter duly signed by garrison engineer contractor and engineer-in-charge shall be maintained on records, all as per description of serial item no 1000 here in before but for 11kv rmu 4 way2lbs 2vcb type complete all as specified and as directed, all as per description of serial item no 1000 here in before but for 11kv rmu 3 way2lbs 2vcb 3lbs type complete all as specified and as directed, all as per description of serial item no 1000 here in before but for 11kv rmu 1way 2 way type complete all as specified and as directed, ml testing and calibration of 11kv rmu 3 way type 2lbs 1vcb of make schneider outdoor type alongwith control panel and control wiring protection system and relays system relay to tripping coil auxiliary switch male and female housing cut outs etc checking of quality of vacuum interrupter insulation resistances static contact resistance testing ir value ratio test polarity test and connection verification of 11 kv current transformer set of three by primary injection kit and testing and calibration of relay set of two over current and one earth fault by secondary injection kit including all other functional tests of the vcb cr panel and cts pts complete all as specefied and directed note test report of all parameter duly signed by garrison engineer contractor and engineer-in-charge shall be maintained on records, all as per description of serial item no 1400 here in before but for 11kv rmu 4 way2lbs 2vcb type complete all as specified and as directed, all as per description of serial item no 1400 here in before but for 11kv rmu 5 way2lbs 3vcb type complete all as specified and as directed, disconnecting the 33 kv outdoor vcb unit and indoor control panel capacity upto 1600 amp overhauling of complete unit opening the total mechanical and electrical mechanism of breaker checking its contact baffles plates and other minor parts cleaning the complete accessories carefully minor repairs rectified partsaccessories cleaned the tank baffle plates rotating contact upper supports lower support drive assemblies and all other spare parts reassembled after repairreplacement of the spare parts including calibration testing of existing protection relay as per load parameter complete all as specified and directed notes i repair work shall be carried out only by the authorised technician of manufacturer of vcb ii spare parts as required for replacement of existing worn out parts shall be measured and paid separately under appropriate items iii labour for replacement fixing of the supply only items shall be deemed to be included in the unit qouted against this item iii make of all spare parts shall be used as per existing make of manufacturer iv test report of all parameter duly signed by garrison engineer contractor and engineer-in-charge shall be maintained on records, isolating contact assembly suitable for 33 kv vcb panel, tnc switch for 33kv vcb panel, indication lamp led type suitable for 230 volts ac 50hz and 11030 volts dc supply, hrc fuse 33 kv grade 2 amps to 5 amps, hrc fuse 33 kv grade 10amps to 20 amps, vacuum interrupter suitable for 33 kv ht vcb complete all as specified and directed, motor gear assembly 230v ac suitable for 33 kv ht vcb including testing puting on load complete all as specified directed, spring bearing gear suitable for 33 kv ht vcb complete all as specified and directed, closing coil assembly 24 volts dc suitable for 33 kv ht vcb complete all as specified and directed, tripping coil assembly 24 volts dc suitable for 33 kv ht vcb complete all as specified and directed, panel door lock suitable for 33 kv ht vcb complete all as specified and directed, auxillary switch 7 no 7nc suitable for 33 kv ht vcb complete all as specified and directed, digital amp meter ct secondary site selectable 5a for 33 kv vcb control panel, digital volt meter for 33 kv vcb control panel, upper connector suitable for 33 kv ht vcb complete all as specified and directed, lower connector suitable for 33 kv ht vcb complete all as specified and directed, support road with screws suitable for 33 kv ht vcb complete all as specified and directed, supplying and fixing in replacement of potential transformers oil cooled outdoor type 33 kv single phase having ratio 33 kv rt3 110 rt3 110 rt3 complete all as specified and as directed, supplying and fixing in replacement of current transformers oil cooled outdoor type 33 kv single phase having ratio 1005 complete all as specified and as directed, supplying and fixing in replacement of potential transformers oil cooled outdoor type 11 kv single phase having ratio 11kv rt3 110 rt3 110 rt3 and hsv 12kv complete all as specified and as directed, supplying and fixing in replacement of current transformers oil cooled outdoor type 11 kv single phase having ratio 1005 and hsv 12kv complete all as specified and as directed, ml servicing of 33 kv potential transformer cleaning of core checking of all electrical connections rectifying including replacement of new oil and testing commissioning with complete all as specified and directed note- cost of oil included in the above quoted rate, ml servicing of 33 kv current transformer cleaning of core checking all electrical connections rectifing any minor faults including replacement of oil and testing commissioning with complete all as specified and directed note- cost of oil included in the above quoted rate, ml servicing of 11 kv potential transformer cleaning of core checking of all electrical connections rectifying including replacement of oil and testing commissioning with complete all as specified and directed note- cost of oil included in the above quoted rate, ml servicing of 11 kv current transformer cleaning of core checking all electrical connections rectifing any minor faults including replacement of oil and testing commissioning with complete all as specified and directed note- cost of oil included in the above quoted rate, ml for repair and servicing of ht 33kv main receiving power station 33kv yard by replacing galvanized pg clamps gi bolts and nuts pieces of acsr conductor with insulation of any size as jumpers including lubricating the moving parts of ab switch and cleaning of all disc pin insulators and applying silicon compound for prevention of arcing due to dust salt deposits over the surfaces including applying one coat of zinc oxide primer on rusted portions after preparation of surfaces a coat of aluminum paint to the entire structure complete all as directed note-rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces and steel surfaces acsr conductor for jumpering bus bar replacement of unsv discpin type insulator by new gi hard ware like nuts bolts etc complete, supply only synthetic rubber insulated mats 3mm thick for voltage 33kv for electrical purpose as per is 15622-2006superseding is 5424 suitable for electrical shock safety of sizes 2 mtr x 1 mtr with complete all as specified and directed, supply fixing in replacement complete motorised spring drive mechanism with gear assembly of 11kv rmu of make schneider outdoor type checking of quality of vacuum interrupter insulation resistances static contact resistance testing ir value ratio test polarity test and connection verification of 11 kv and testing commissioning with complete all as specefied and directed, supply and fixing as in repairs pg clamp die cast aluminium of suitable size and for fixing clampling acsr conductor connections for pts cts isolators all as specified, supply and fixing in replacement multi stranded copper conductor cable 1100 volts grade isi marked frls pvc insulated and unsheathed of size 25 sqmm 2 core complete all as specified and as directed, supply and fixing in replacement multi stranded copper conductor cable 1100 volts grade isi marked frls pvc insulated and unsheathed of size 15 sqmm single core complete all as specified and as directed, tracing out fault in 11kv underground cable any size with the help of fault detection machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified note i joint kit shall be measured and paid separately ii earth work shall be measured and paid separately however width of trenches shall be allowed for payment as per authorized width given in ssr for each size of cable iii all other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted iv tp required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account v cable required if any shall be measured and paid for separately vi fault location thereof shall be traced within 12 hours of intimation by the engineer-in-charge and shall be rectified within given time frame, material and labour for straight through joint ht 11000 volts grade heat shrinkable of cable cross sectional area 95 sqmm 3 core complete all as specified and directed note 1 excavation earthwork shall be measured and paid for separately, material and labour for end termination joint indooroutdoor type heat shrinkable ht 11000 volts grade of cable cross sectional area 95 sqmm 3 core complete all as specified and directed, all as per description of serial item no 3500 here in before but for cable of cross sectional area 120 sqmm 3 core, supply laying and testing xlpe insulated armoured 11000 volts grade aluminium conductor cable cross sectional area 95 sq mm 3 core as per is-7098 part-ii in trenches or fixed to wall passing through pipe pole and including taking out old unsv cable as directed for the following cross sections note i excavation and earth work shall be measured and paid for separately ii concrete cover protection and sand cushining shall be measured and paid for separately iii pipe including clamps shall also be measured and paid for separately, supply and laying xlpe insulated armoured heavy duty 1100 volts grade aluminium conductor cable cross sectional area 95 sqmm 35 core in trenches or fixed to wall passing through pipe pole and including taking out old unsv cable and testing compete all as specified and directed by engineer-in-charge note i excavation earth work brick protection and sand cushining shall be measured and paid for separately, all as per description of item no38 here-in-before but cross sectional area 120 sq mm 35 core, boring of holes under road pavement hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable water pipe line etc including gi pipe of 80 mm dia light grade and sealing the end of pipe complete all as specified and directed, excavation in trenches not exceeding 15 metre wide and not exceeding 15 metre in depth for laying of cable and getting out in soft loose soil complete all as specified and as directed note- i serviceable brickspcc cover stacked for reuse, returning filling in trenches including spreading levelling watering and well ramming in layers not exceeding 25 cm in soft loose soil complete all as specified and as directed, removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 15 metre above the starting point complete all as specified and as directed, material and labour sand cushioning tibba sand for protection of underground cable consolidated and compacted with clean dry sand complete all as specified and as directed, supply and laying precast unreinforced concrete cable covers class hv type 1 flat of size 300mm x 180mm x 40 mm for ht cable all as specefied, material and labour well burnt old size sub class b bricks laid flat in trenches for cable protection complete all as specified and directed by engineer-in-charge, taking down old unserviceable gi plate earthing and material and labour as in replacement of earthing complete with copper earth plate electrode 600 mm x 600 mm x 315 mm thick burried directly and preferably vertically in ground earth pit not less than 225 mtr deep below ground level with top eadge of the plate not less than 15 mtr below ground level the earth plate to be connected with copper earthing strip and earth plate of size 20 mm x 3 mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing onlythe copper earthing strip to be protected by galvanlsed iron pipe 40 mm bore medium grade upto ground leveland there after with 40 mm dia hdpe pipe upto test point earthing shall be included with providing funnel with 20 mm bore galvanised iron pipe light grade wire mesh charcoal or coke and common salt in alternate layer of 15 cm compacted thickness upto 90 cm all round earth plate further filled with 60 cm thick tibba sand and second layer with 30 cm of magnesium sulphate powder compated thickness3 rd layer with tibba sand up to the ground level earthing shall also be in clude for providing concrete earth pit in pcc 136 type c -1 with 20mm grade aggregate 50 mm thick precast rcc 124 cover slab re inforced with excavation returning filling and removal of surplus soil upto a distance not exceeding 50 mtr etc all as shown on electrical plate no 3 of mes schedule part i complete to obtain less than 2 ohm earth recistance value complete all as spcified note - plate no 3 of ssr part i is given is given for guide of earth chamber, material and labour for earthing complete with gi earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly and preferably vertically in ground earth pit not less than 225 mtr deep below ground level with top edge of the plate not less than 150 mtr below ground level the earth plate to be connetced with earth lead of 25x4 mm gi strip all as shown in para no 4 the earthing test point all as specified and directdthe gi earthing strip to be protected by galvanised iron pipe 40 mm bore medium grade up to ground level and there after with 40mm dia hdpe pipe up to test point earthing shall be include with providing funnel with 20mm bore galvanised iron pipe light grade wire mesh charcoal or coke and common salt in alternate layer of 15cm compacted thickness up to 90 cm all around earth plate further filled with 60 cm thick tibba sand and 2nd layer with 30 cm of magnesium sulphate powder compact thickness 3rd layer with tibba sand up to the ground level earthing shall also be include for providing concrete earth pit in pcc 136 type c-1 with 20mm graded crushed stone aggregate 50mm thick precast rcc 124 cover slab re-inforced with 8mm dia tmt bar 15 cm cc bothways and suitable handle made of 10mm dia including necessary earth work all as specified and directed, ml as in repairs chemical earthing complete with copper earth plate electrode 900 mm x 600 mm x 5 mm thick buried directly in ground vertically in a pit of depth not less than 365 metre below normal ground level with top edge of the earth plate at a depth not less than 290 metre below normal ground level earth plate connected to copper strip 32 x 6 mm as earthing lead by means of running gas welding brazing for a length of 45cm copper strip protected by galvanized steel pipe 40 mm bore medium grade upto ground level and there after by 40 mm dia hdpe pipe upto test point maximum upto 75metre from earth plate earth plate surrounded by charcoal or coke and common salt upto 90 cm in alternate layers of 15cm each thereover a layer of 60cm tibba sand duly compacted thereafter 30 layer of magnesium sulphate powder compacted thickness and finally filing the top of pit upto ground level with tibba sand to achieve earth resistance value less than 1 ohm including provision of 20mm bore galvanised steel pipe 20mm bore light grade with funnel wire mesh for watering earth pit chamber built in cement concrete 136 type c-1 using 20mm graded stone aggregate covered with 50mm thick pre-cast cover slab of rcc 124 type b-1 duly reinforced with 8mm dia ms tmt bars 15cm cc both ways with suitable handle made of 10mm dia ms round bar including excavation earthwork in any type of soil strata removal of surplus soil to a distance not exceeding 50 metre as shown in electrical plate no 3 of mes schedule part-i complete all as specified and directed, material and labour for preparation of existing dull painting of vcbsf6rmu indoor outdoor type and applying two coats of synthetic enameled paint heat resistant type according to is colour code by spray machine including writing messm no in capital letters of suitable size on body for capacity 11 kv 400630800 amps outdoorindoor complete all as specified and directed, material and labour for htlt cable route marker htlt joint marker made out of jodhpur stone of size 250 mm width x 100 mm depth x 900mm height size with top oval shaped engraved with htlt cable duly painted with approved colour with writing letter for both side complete all as specified and directed by engineer- in- charge note - i route marker shall be buried in ground upto a depth of 45cm below the natural ground level ii rate quoted shall include the cost of necessary excavation and earth work, material and labour for labour for taking out the existing unserviceable ups of capacity 35kva suitable for voltage 18 to 52 v dc supply transporting to authorised repair workshop carrying out the necessary repair re-assembling the ups and testing commissioning for satisfactorily working including replacement of spare parts of with complete all as specified and as directed, material and labour for labour for taking out the existing unserviceable ups of capacity 390va suitable for voltage 18 to 52 v dc supply transporting to authorised repair workshop carrying out the necessary repair re-assembling the ups and testing commissioning for satisfactorily working including replacement of spare parts of with complete all as specified and as directed, supply and fixing in replacement rechargable ups battery 12v 100ah including electrical connections with complete all as specified and directed, all as per description of item no54 here-in-before but capacity of battery 26ah 12volt, all as per description of item no54 here-in-before but capacity of battery 65ah 12volt, all as per description of item no54 here-in-before but capacity of battery 7ah 12volt, material and labour for replacement of providing and filling postframe work of stainless steel grade 304 pipes including braces of stainless steel plates angle flats tubular sections etc including cutting hoisting fixing with argon welding bright finish buffing polishing grouting with pcc 124 type b1using 20mm graded stone aggregates in the existing foundations complete with necessary holes nuts bolts caps and anchor plates for stainless steel as specified and directred by engineer-in-charge, material and labour for installation of poly carbonate micro prismatic type retro reflective boards conforming to xi of astm made of 4mm thick substrate of aluminium composite panel having 050mm thick skin of aluminium both side the front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type xi of astm with coloured scheme including subject matter message bi-lingual symbol and borders etc as per irc 67-2001 the aluminium composite panel shall be suitably fixed inside stainless steel frame work complete all as specified and directred by engineer-in-charge, material and labour for mild steel chequered plates any thickness laid above cable duct conforming to fe-290 gde e-165 including taking down old unserviceable one complete all as specified and directed by engineer-in-charge, supply and installation bird control white nylon hdpe knotted anti bird net of 1516ply mesh size less than 125mm uv stabilized waterproof resistance to water corrosion and chemical multi filament with installation kit cable ties c hook nails ropes attched on borders of the net for easy installations including taking down of existing unsv net complete all as specified and as directed, supply installation testing commissioning in replacement of 11kv air insulated indoor type copper busbar coupler with maximum system voltage rating of 12kv suitable connection arragnement for of one vcb vcb make-schneider electric voltage rating-12kv switch gear type-pix mv rated normal current of busbar-1250amp srl no 02229013700114 to other vcb vcb make- abb india ltd voltage rating-12kv switch gear type -lgzn1 rated normal current of busbar-1250amp srl no 1vyn010926000076 with electrically mechanically busbar rating of 1250a short circuit capacity of 263ka bus-bars shall have full voltage sleeving on it and shall be self-supported type ie without any support insulators bus bar should be electrolyte copper the panel shall be tested for iac aflr for 263ka1s goose generic object oriented substation event signals shall be freely configurable inter-operability test shall preferably shall be done proof wrt interoperability shall be submitted by the manufacturer test service shall be considered in the scope of copper bus bar coupler the proposed copper bus bar coiupler are to be integrated mechanically as well as electrically with the existing vcbs and the rate of integration is to be included in the quoted rate note-1 it is advised to all bidders to visit the site before quoting the tender 2copper bus bar coupler shall be fixed in pcc foundation as per manufacturer recommendation and the cost of the same shall deemed to be included in unit quoted rate 3 contractor shall submit the ga drawings of switchgear busbar riser connector panel for approval of ge before placing the order, supply and fixing as in repairs lt panel outdoor type floor mounted free standing dust and vermin proof panel db cpri approved with ip-65 protection frame fabricated out of 40mm x 40mm x 4mm angle iron 315 mm thick crca sheet for entire outer panel with single door and locking arrangements 16 mm for inner compartment with 40mmx4mm flat iron including separate cubicle chamber with cable alley not less than 300mm width for installationconnecting switchgears with the main bus bar using copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles ms surfaces epoxy based powder coated shade as approved over 2 coats of red oxide primer surfaces pre-treated in seven tank process for de-greasing de-rusting phosphated panel having front and rear opening and provision for installation of separate cable alleys busbar chamber and switchgear compartments provision in cable alleys for bottom cable entry for incoming outgoing cables affixing mv danger plate at suitable intervals locations including erection testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned below, supply and fixing in replacement 33kv three phase elctric energy meter trivector energy meter class-02s accuracy suitable for 3 phase 4 wire ht metering system operating voltage 6 x 635v basic current ratting 5alb max current 10a200 of lb 50hz frequency compliant with is 14697 standard with lcd display pulse output facility ctpt operated auxiliary supply 60-240v acdc-20 self powered and complete communication energy monitoring feaures with testing commissioning all as specified and directed note-1 contractor should visit the mrs yard before quoting tender 2 the installation testing commissioning and calibration of abt meter shall be completed in pressence of jdvvnl rep and the above expenditure included in the above quoted rate
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
excavating in trenches nexc 15 mtr wide and nexc 15m in depth for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out on any type of soil complete all as specified and directed, excavating in trenches nexc 15 mtr wide and nexc 15m in depth for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out in hard and dense soil complete all as specified and directed, excavating in trenches exc 15 mtr depth and nexc 15 mtr wide for foundation etc or for shafts wells cesspits man holes etc nexc 10 sqm on plan and getting out on any type of soil complete all as specified and directed, returning and filling in including spreading and levelling watering and well remming in layers not exc 25 cm all as specified and directed, removing excavated soil to a distance nexc 50 mtr and depositing where directed at a level nexc 15 mtr above the starting point all as specified and directed, supply laying testing commissioning of ht 33 kv earthed isi marked xlpe insulated screened pvc bedded electric power cable heavy duty with aluminium conductor 33000 volts grade circular screened with extruded semi conducting compound in combination with copper tape inner sheath of pvc tape galvanized steel strip flat around and overall pvc sheathed armoured conforming to is 7098 part ii 1985 amended upto date of size 3 core 300 sqmm isi marked laid in trenches or passing through pipesducts including taking down old cable of any size all as specified and as directed note - 1 excavation and earthwork sand cushioning gi pipe cable protection shall be measured and paid separately 2 cable shall be tested at high voltage test before after laying 3 no straight through joint shall be permitted inside pipe or duct 4 cost of straight through joints required if any shall deemed to be included in the quoted rates of cable, supply and fixing in replacement of ht single core power cable 11 kv isi marked earthed strandred of size 95 sqmm compacted circular aluminium conductor conductor screen with extruded semiconducting compound xlpe insulated insulation screening with extruded semiconducting compound in combination with copper tape aluminium round wire armored and frls pvc inner and outer sheathed oxygen index cable confirming to is 7098 part ii 2011 up to date amendments complete all as specified, supply lay hdpe dwc pipe 110mm bore for laying of ht cables etc complete with all jointing accessories all as specified and directed, sf steel tubing gi light grade of size 80mm bore dia for cable protection passing under road floor or for fixing to poles all as specified and as directed, ml for cable jointing kit for 11 kv grade cable for straight through heat shrinkable joint suitable for xlpe armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed make dension m sealsiemens, all as per item no 10 above but 120-185 sqmm 3 core all as specified and directed, ml for end termination cable jointing kit for 11 kv grade cable heat shrinkable joint out door suitable for xlpe armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 95 sqmm all as specified and directed make denson m sealsiemens, all as per item no 12 above but 120-185 sqmm 3 core all as specified and directed, all as per item no 12 above but 240-400 sqmm 3 core all as specified and directed, ml for end termination cable jointing kit for 33 kv grade cable heat shrinkable joint out door suitable for xlpe armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 300 sqmm all as specified and directed make denson m sealsiemens, m l for checking of ht ug 11 kv xlpe faulty cable with ht ug cable fault locating testing machine rectifying the fault putting the jointing kit and charging the cable approx length 650 rm for each job complete as all as specified and directed the rate for excavation removing of old cable laying after repairs is deemed to be included in the rates quoted, dismantling of existing unserviceable ht lt poles of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata demolition of concrete disconnecting of conductor etc all as specified and as directed, ml for cement concrete 148 type d2 using graded stone aggregate as in foundation for pole including necessary form work all as specified directed, demolition of cement concrete as in pole coping and depositing where as directed, ml cement concrete 136 type c1 using graded stone aggregate as in foundation for pole including necessary form work all as specified directed, dismantling of unserviceable existing cross arms made from channels angles and unserviceable fi clamps nuts bolts etc from oh line and removing complete all as specified and as directed, ml for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts botls washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide primer one under coat and one inishing coat of aluminium paint all as specified and as directed, dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed, ml for pin type porcelain vitreous brown or green insulator including one galvanised mild steel spindle steel washers and one galvanised nut of size 150mm height 150mm dia for 11000 volts grade complete all as specified directed, m l for disc type porcelain vitreous white or brown 145 mm height 255 mm dia ball and socket type complete with tension assembly clamps for conductor for 11000 volts grade single disc assembly complete all as specified directed, dismantling carefully the existing unserviceable htlt overhead line acsr conductor of any size from its position by necessary disconnecting of conductor and removing complete, supply and stringing new acsr conductor weasel ferret for over head line securing on pole complete including binding wire jointing sleeves aluminium tap and pg clamp etc of any size all as specified and as directed note - a jumper on cutout point2 pole structure4 pole structure shall be provided with pvc insulated sleeve b rate is inclusive of jumper tree branch cutting to make a safe distance from over head line, sf in repairsreplacement of continuous gi earth wire 4mm dia on cross of poles for guarding including binding with aluminum wire 16 swg etc and dismantling of old broken guarding complete all as specified and directed, ml for restringing of ht over head line consisting of 3 conductors by dismantling taking down repairing wherever required including cutting re-jointing and restringing in situ with proper sag binding to insulator with and including aluminium binding wire complete all as per specified and directed, sf jumpers in replacement made out of 61 x 259 mm weasel acsr conductor including pvc alkaline pipe and nuts bolts etc all as specified and as directed, sf jumpers in replacement made out of 61 x 472mm dog acsr conductor including pvc alkaline pipe and nuts bolts etc all as specified and as directed, dismantling of unserviceable stay assembly carefully including stay wire including necessary excavation and earth work in any type of soil demolition of pcc of any type and removing from site al as specified and as directed, sf in replacement of galvanized ms stranded stay wire of size 74mm including necessary binding straightening complete all as specified and directed, s f in replacement of loop type insulators vitreous porcelain white brown or green large size with over all dimensions 140mm clearance of hole 255mm including necessary cutting jointing all as directed by engr-in- charge, sf stay assembly complete with accessories as shown in electrical plate no 1 of ssr 2009 part i using stay rod 20mm dia including clamps made out of 50 x 6mm ms flat ms galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm and conductor all as specified and as directed note loop type insulator stay clamps excavation and concrete shall be measured and paid separately, m l for replacement of danger notice plate of 16mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with ms clamps of size 25x4mm bolts and nuts of approved size for ht 25x20cm size complete all as specified and directed, ml for pruning and removing of tree branches touching to electric over head lines wild growth around lt ht over head lines and around pole and stay complete to make clear span of 15 mtr of tree both sides of the oh line with jcb hydraulic vehicle cutter and all tools plants etc all as directed by engineer-in-charge note i distance between pole to pole will be measured and paid ii any breakdown of line caused during pruning shall be made good without any extra cost iii the contractor shall ensure proper safety of the tradesmans to avoid any mishappening if any mishappening occures the contractor shall be solely responsibleiv laddervehicaltansport required for tree cutting shall be supplied by contractor at his own arrangement cost of vehicaljcbladdermanpower included in quoted rates, sf in replcement of vertical type air break switch gang operated triple pole mechnically operated outdoor type with all fittings and accessories mounted on and including ht 11 kv porcelain insulators 9 nos and steel channel frame gi operating rod 25 mm dia of suitable length to worked from ground including locking arrangements suitable for 11000 volts 400 amps current rating complete including dismantling existing one all as specified and as directed, repair maint of air break switch by replacing stationary and moving contacts flexible copper chord gi nuts bolts etc including alignment for smooth functioning from ground level all as required at site and all as specified directed, sf in replacement of ht 11 kv out door non-linear type lightening arrestor with mountings accessories complete fixed on cross arms of two pole structure gi flat strip and connect with same size of acsr conductor encased in pvc alkathine pipe with all fittings connected to earth strip with nuts bolts and washers transmission class having discharge capacity of 65 ka and rupturing capacity 5 kva and suitable for working pressure 9 kv rms complete including taking down old lightning arrestor including dismantling existing one all as specified and as directed, sf drop out fuse unit explusion type for out door air break gang operated switch single pole mounted on and including insulators for 11 kv working pressure fixed to and including ms channel with nuts bolts and washer etc synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity upto 400 amps all as directed including taking down old one all as specified and as directed, ml for replacement of earthing of polessystem with galvanised earth plate 60x60 cm x 6 mm thick electrode of size and 32 x 6mm gi strip buried vertically in ground not less than 225 mtr below ground level with top edge of the plate not less than 15 mtr below ground level and connected to copper strip dia by means of nuts bolts and washers and encased in and including 15 dia gi medium grade pipe upt 24 mtr height from ground level fixed by ms flat iron clamp 40mm x 5mm with nut bolt and washers gi strip fixed to base along pole and connected to over head line for providing earthing to ht polefeeder ab switch la complete with charcoal dust salt packed around plate 150 mm thick including watering gi pipe medium grade 40 mm dia with blanking cap 15 mtr long fixed to funnel with wire mesh complete with pcc chamber and rcc chamber over all as per electrical plate no 3 of ssr part i - 2009 incl excavation and earth work in any type of strata and testing on compeltion note any length of gi strip and 15 mm dia gi medium grade pipe shall be provided as per actual requirement at site, supply install in replacement of gi strip 32 mm x 6 mm buried groundfloorsurfaceroof including taking doown existing gi strip complete all as specified and directed, supply fix in replacement of complete with saddles and epoxy insulator for fitting the stripincluding taking down existing al strip complete all as specified and directednote rate included with insulater, supply and spreading stone aggregate of size 20 mm at 11 kv substations near dp structures electrical outdoor installation yard after through cleaning anti grass treatment etc all as per pecified and as directed, supply and fix in replacement of basic numerical relay wide range with facility over current phase fault short circuit earth fault instantaneous with connected accessories complete all as specified and directed make cgl tashida, supply and fix in replacement of ingress protection relay wide range 4bi 6bo iec 103modbus on rs 485 port non draw out 24-250 vdcac universal voltage ct secondary 1a 5 a universal wide range complete all as specified and directed, labour only for disconnecting repairing servicing of existing ht 11 kv33 kv vcbssf6 breakers of any make from housing and cleaning rubbing and overhauling the mechanical parts and servicing of 11 kv indoor vcb upto 800 amp checking of quality of vaccum interrupter insulation resistances static contact resistance testing ir value ratio test polarity test and connection verification of 11 kv current transformer set of three by primary injection kit and testing and calibration of relay set of two over current and one earth fault by secondary injection kit including all other functional tests of vcb cr panel and cts pts auxilary relay complete all as directed note i rate included also for complete bus bar cleaniong and tightning checking of bus bar insulation test ir test with heat shrinkasble bus bar slive ir test crm test for busbar and breaker including testing of breaker ir testing closing and opening time test coil ressitrance test motor resistance test and submit the all final test reports checking and replacement of rusted ht hardware nut and bolts ii contractor shall make his own arrangement of testing equipments and electric supply so required a detailed test report should be submitted to engr-in-charge iii all test shall be carried out by authorised company service dealer with company othorised certificate of individual iv service charges of service engineer for attending servicingoverhauling of 11 kv vcb included in quoted rates, labour only for testing of power transformer routine regular at site 3311 kv 315 mva including removing of both side cable and refixing the same after carrying out folling test ir test ratoi test magnetic core balance test open circuit test vector group test short circuit test no load test winding resistence test complete note test report mandatory for all test and shall be submitted to engr in charge is resposibility of contractor ii external eletric supply and transport required for all above test is supplyed by contractor at his own arregement rate included in quoted rate, supply and fix in replacement of dc power pack input 230 volt ac and output 30 volt dc spd base continous load 100 va impulse load 450 volt for 240 ms backup 20 minutes complete all as specified and directred make gogate elerosystem allen electricals and equivalent, supply and fixing cttb current transformer terminal block 2 5 sqmm including control wiring 25 sqmm suitable for 11 kv vcb complete all, supply and fixing in replacement of pt fuses suitable for 11 kv rating 315 amps complete all as specified and directed, supply and fixing hooter suitable for control relay panel of range 18 -90 volt acdc complete all as specified and directed, supply and fixing in replacement of breaker control switch four position suitable for 15 amps complete all as specified and directed, suply and fixing in replacement of space heater 10080 watt for vcbs 11 kv complete all as specified and directed, s f in replacemennt for resin cast type twin secondary current transformer of ratio 100-505-5a core 115 vaclass 05 and core 2 15 vaclass 03 p10 stc 263 ka1 sec for protection and metering conforming to is 2705 of 1992 complete all as directed, supply and fixing in replacement of toughend arylic transparent door glass with gas kit of suitable size existing size 5 mm, supply and fix in replacement of auxilary contactor 2 no 2 nc with add on 30 volt dc 20-25 amps make l 7 t abb siemens, supply and fixing in replacement of trippingclosing coil 11kv 30 volt dc complete all as specified and directed make cromptonkirloskar, supply and fixing in replacement of trippingclosing coil 33kv 30 volt dc make cromptonkirloskar, supply and fixing in replacement of fuse base with carrier 20 amp make cg, supply and fixing in replacement of 32 pin plug and socket for cg breakercomplete all as specified and directed, supply and fixing in replacement of tripping half shaft for 11 kv cg vcb complete all as specified and directed, supply and fixing in replacement of closing half shaft for 11 kv cg vcb complete all as specified and directed, supply and fixing in replacemnt of master trip relay 30 volt dc cgl complete all as specified and directed, supply and fixing in replacement of big gear assembly for 11 kv vcb make - cgkirloskar, supply and fixing in replacement of small gear assembly for 11 kv vcb make- cgkirloskar, supply and fix in replacement of warm wheel for 11 kv vcb full teeth compmete all as specified and directed make cg, supply and fix in replacement of motor cut off limit switch suitable for 11 kv vcb complete all as specified asnd directed, supply and fixing in replacement of micro switch assembly for vcb 11 kv make -kirlosker cg, supply and fix in replacement of anti pumpiung device relay for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of timer for motor protection range 0-25 amps for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of trip circuit healthy push butten with normally open contact for 11 kv vcbs complete all as specified and directed, supply and fix in replacement of announaciator for sf6 control and relay panel upto 12 window voltage range 18-90 volt complete all as specified and directed, m l for replacement of sf6 copper armed cable 10 core 25 sqmm complete all as specified and directed, ml for gas charging for breaker by using sf 6 gas including checking sf6 gas pipe line pole leakage and reparing and reffiling of gas complete all as specified, supply and fix in repair of ratchet wheel assembly for sf6 breaker 33 kv, supply and fix repair povel set assembly make as per existing site for sf6 breaker, supply and fix in repair closing latch aseembly, supply and fix in repair of complete set oring assembly, supply and fix in repair of crank lever assembly, supply and fix in repair of avr relay for rtcc panel 110v ac, supply and fix in repair of tap position indicator meter for rtcc panel complte all as specified, supply fix and testing of rtcc panel including rewiring relay setting testing calibration and reconditioning complete all as specified and directed, labour only for dehydration filtration and cleaning of transformer oil of 33 kv 11kv power transformer distribution transformer ht switchgear till achievement of die-electric-strength of strength should be not less than 40 kv for new insulating oil and 45 kv for existing oil at 25mm gap all as specified and directed note i toping of transformer oil shall be measured and paid separately ii transportation of filtration vehical and required vehical mounted dg set for power supply during the filtration of transformer is responsibility of contractor and rate included in quaited rates, supply only new insulating oil conforming to is 335 for power transformermocb etc all as specified and directed note transfor oil shall be supply only in seailed barrel, decanning the power transformer oil from leaking transformer by opening the stop valvechecking for leakages arresting the leakages replacing cork sheet gasket 5 mm thick bushing washer hvlv road tapchanger gasket reassembling the transformer completely at nearest authorized workshope refilling transformer oil connecting ht lt connection complete and back install at sub station 3311 solapur new klp all as directed note i spares required shall be measured and paid separately under relevant ii topping of transformer oil will be measured and paid separately iii the rate quoted includes hvlv rod gasket cork sheet washers tap changer gaskit etc iv the rates also includes charging with and without load v the rates includes transportation of transformer to workshop and after repairing installed back at site complete all as directed by engr-in-charge vi re-insulation heating of lvhv coil included in rate quoted, ml for existing 33 kv 800a god set horizontal operation by replacing all stationary and moving contacts for all the three phases rutsed nuts bolts all as specified and directed, ml for repair and servicing testing and recommissioning series reactor by replacing gasket set insulating oil etc including painting by using two coats of synthtic enemel paints all as specified and directed, m l for taking down carefully transformer of capacity 315 mva any make any type from pole plinth base disconnecting hvlv side connections earthing strip of transformer supporting angles cross arm shifting transporting transformer carefully from the site to the workshop minimum 30 kms from site opening the top cover of the transformer bushing removing the tap changer conservator breather assembly draining of oil from the transformer lifting the core complete taking out defective coils from the core cleaning the tank and reassembling the transformer after carrying out the repairsreplacement of worn out part ovening the complete unit till to get desired megger value complete spray painting transporting returning back to the site installing re-commissioning and testing of the transformer at its original place as per is 2026 connecting up hv lv sides earthings supports cross arms etc all as directed by eic i repair of damaged transformer is including of quoted rate ii lv coil reinsulation -543 kg is including of quoted rate iii hv coil re insulation - 640 kg is including of quoted rate iv painting of transformer testing as per is 2026 is including of quoted rate note i spares rewinding of transformer if will be measured and paid separately under respective items, ml rewinding of oldburnt out 33 kv power transformer lv coils with super enamelled copper winding wire dpc cu of appropriate size of superior quality including insulating material varnishing heating coil in position copper bus bar and charging completely all as directed in engr-in-charge, supply and fix in repalacement of insulation material complete all as specified and directed, supply filling new transformer oil conforming to is 335 for transformer etc all as specified and directed, supply and fix in replacement of hv terminal rod complete all as specified and directed, supply and fix in replacement of hv bushing cap complete all as specified and directed, supply and fix in replacement of breather complete all as specified and directed, supply and fix in replacement of hardware tank nuts bolts complete all as specified and directed, supply and fix in replacement of oil level indicator glass complete all as specified and directed, supply and fix in replacement of explosion vent diapraghm complete all as specified and directed, supply and fix in replacement of core bolt insulation complete all as specified and directed, supply and fix in replacement of bushing member complete all as specified and directed, m l for servicing testing of oltc including opening top and bottom plate removing of oil and refilling of oil and checking of all taps removing of unsv parts and replace it complete all as specified and directed note spare parts and oil measured and paid separetly, supply and fix in replacement of resistance moving contact assembly for oltc complete all as specified and directed, supply and fix in replacement of main moving contact assembly for oltc complete all as specified and directed, supply and fix in replacement of contact for oltc complete all as specified and directed, supply and fix in replacement of transister register assembly for oltc complete all as specified and directed, supply and fix in replacement of local remote switch for oltc complete all as specified and directed, supply and fix in replacement of electrical counter for oltc complete all as specified and directed, supply and fix in replacement of directional selector switch oltc complete all as specified and directed, supply and fix in replacement of oil sealed for oltc complete all as specified and directed, supply and fix in replacement of top let gasket bottom let gasket assembly for oltc complete all as specified and directed, supply and fix in repair auto manual selector switch for oltc complete all as specified and directed, supply and fix in repair on 0ff switch for oltc complete all as specified and directed, supply and fix in repair lowerraiseack push butten for oltc complete all as specified and directed, supply and fix in repair tap changer alarm hooter complete all as specified and directed, supply and fix in repair mechanism stuck alarm hooter for oltc complete all as specified and directed, supply and fix in repair tap counter for oltc complete all as specified and directed, supply and fix in repair tap position indicator for oltc complete all as specified and directed, supply and fix in repair starter three phase 4-10 amps complete all as specified and directed, supply and fix in repair spring charging motor gear box assembly 230 vac for vcb 11 kv make - cromptonabbsiemens, supply and fix in repair control fuse links ns type 2a 4a 6a 10a 16a complete all as specified, supply and fix in repair only bus bar support insulator complete all a specified and directed, sf in repair of dropout do fuse expulsion for outdoor single pole mounted on and including 33000v insulator - 02 nos and ms channel with nuts bolts and washer of capacity 100amp all as specified and directed, sf in repair of lightning arrestor station class metal oxide 33 kv class iii iec long duration current impulse rating with pressure relief high suitable for 33 kv including reconnecting in 33 kv distribution circuit and testing all as specified and directed, supply and fixing in repair marshaling box with terminal box including tb terminal for ctpt connection for 33 kv vcb including complete wiring and testing complete all as specified and directed, supply and fix in repair 33 kv sf6 outdoor breaker tr-02 closing linkage assembly complete all as specified and directed, supply and fix in repair mcb dp 10 amps 10 ka complete all as specified and directed, ml for painting to 33 kv substation outer fencing and 11 kv substation fencing of structure complete including channel beams angle bracket supports clamps by using two coats of aluminium paint after scrapping out existing worn out paint including square wire mesh all as specified and directed, s f in replacement sign boards for mes installations of size 1200x 900mm made out with angle iron 40x40x 6mm as framing covered one side with 2 mm thick aluminium sheet rivetting on frame covered with retro reflective sheet 100mm high letters as directed th sign board to be fixed on 2 no 40x40x6mm angle iron legs of upto 2 mtr long embedded in pcc 148 using 40mm graded stone aggregate including of necesary excavation complete at the installation etc complete all as specified and directed by engr-in-charge note informationmatter on sign board shall be supplied by engr in charge, m l for painting of vcb panel consist 6 nos of panel in one job outerside with power coating spray painting with instant dry type paint rl 7032 including covering panel assessories like amp meter volt meter relay selector switch etc with masking tape and removing after paint complete all as specified and directed, m l for painting with epoxy paint for vcb breaker insulator complete all as specified, supply and fixing in repair relay fixing plate including cutting drlling fixing etc plate size 200 x 200 mm with power coating rl 7032 complete all as specified and directed, supply and fixing in repair residual voltage transformer voltage ratio - 11kvv3110kvv3190 volt 3 phase 50 hz complete set insulation level - l1 75 ac 2812 cont 19 for 30 sec burden - 50 va sec 50 va ter class - 13 p make harshanil eletric pvt ltd and equivalent as approved by ge, supply and fixing in replacement including testing of power factor capacitor set of 3 outdoor box type fixed on channel 11 kv of following specification capacitor unit pmpo 3 phase rated kvar 70 rated kv 67 50 hz for each rated current 1045 amps temp catagory 50 degree centigrade insulation level - 2875 discharge time - 600 second make madhav capacitors pvt ltd and equivalent as approved by ge, m l for shifting of transformer of any capacity from two pole fore pole structure with crane including dismantling existing connection of transfomer and shifting it on plinth within 100 mtr distance and reconection of transformer after shifting on the plinth with necessary connection and testing for serviceable complete without any damage all as specified and directed by engr in charge note any type of damageleakage of tranformer oil during the shiftingtransportation shall be repaired by contractor at his own cost without any claim, m l for transformer plinth of size 2000mm x 2000 mm x 1500 mm including excavation in trenchs in any type of soil pcc 14 8 in foundation fly ash bricks machinaryin cement mortor1 6 filling with moorum inside the plinth and rcc 124 over plinth including 16 mm bar reinforcement with center to centre distane 100mm and external surface of masonry shall be plastered with cement morter 14 and painted with weather coat paint double coat paint of shade complete all as specified and directed by engr in charge, supply and fixing in replacement of synthetic insulating rubber mat tested for ht 1122 kv with test certificate for installation of size 2m x1m x22 mm etc complete all as specified and directed by engineer-in-charge, supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation returning and removing complete all as specified and directed, ml providing pre cast rcc 113 type a1 using 20 mm graded stone aggregates as in cable route indicator of height 800 mm x width 300 mm x thickness 120 mm duly reinforced all as per details shown in drawing and having top circular section provided with and including pcc 148 type d2 using 40 mm graded stone aggregates foundation of suitable size as directed and including engraving letters mes 11 kv ht on route indicator duly painted in synthetic enamel dark brown colour paint complete all as specified and directed, supply and fixing in replacement of indicating lamp with universal voltage with color coding red yellow blue amber white green all as specified and directed, supply fixing in replacement of digital volt meter single phase all as specified and directed make lt seimens, supply fixing in replacement of digital ammeter meter 1133 kv control supply 230v ac all as specified and directed make lt seimens, s f replacement of ht bushing porcelain vitreous brown body suitable for power transformer as per is 3347 all as specified and directed, m l for replacement of breather assembly including silica gel complete suitable for power transformer existing at site complete all as specified and directed, supply and fix ht 33 kv out door type gang operated air-break switch suitable for horizontal mounting fixed type complete with 9 insulators 33 kv and with earth switch upto 200400 amps with all fittings and accessories mounted on and steel channel frame gi operating rod 25 mm dia of suitable length to worked from ground including locking arrangements suitable for 33000 volts 400 amps current rating complete including dismantling existing one all as specified and as directed, material and labour for copper earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick buried vertically in ground each pit not less than 225 mtrs deep below normal ground level with top edge of plate not less than 150 m below normal ground level connected to copper strip 20 x 3 mm by means of bolts nuts and check nuts and washers etc encased in gi protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extent of 75 meters all as shown on electrical plate no 3 of mes ssr - 2004 part - i gi protection pipe buried in ground laid under floors plinths or mixed on walls pole etc or concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate including pcc 124 type b-1 earth pit with ms angle iron frame cast iron cover with locking arrangement with gi 20 mm dia medium grade pipe and ms funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil strata and testing on completion complete all as specified and directed note- i cost of copper strip 20 x 3 mm and protection pipe 40 mm dia is deemed to be included in rate quoted ii excavation and returning filling of soil any type is deemed to be included in rates, material and labour for chemical earthing complete with copper earth plate electrode 900 x 600 x 5 mm thick buried vertically in ground each pit not less than 225 mtrs deep below normal ground level with top edge of plate not less than 150 m below normal ground level connected to copper strip 32 x 6 mm by means of bolts nuts and check nuts and washers etc encased in gi protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extent of 75 meters all as shown on electrical plate no 3 of mes ssr - 2004 part - i gi protection pipe buried in ground laid under floors plinths or mixed on walls pole etc or concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate including pcc 124 type b-1 earth pit with ms angle iron frame cast iron cover with locking arrangement with gi 20 mm dia medium grade pipe and ms funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil strata and testing on completion complete all as specified and directed note- i cost of copper strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii excavation and returning filling of soil any type is deemed to be included in rates, m l for replacement of sf6 copper armed cable 12 core 25 sqmm complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
pumping out sewage watersludge from the existing septic tank soak well of any size any capacity and any type of material like solidfluid mud sludge etc by mechanical motorised suction machine and deposited removing the sludge etc outside the tech area to a distance exceeding 10 km shall be conveyed in closed container and also disposed off in the place properly using bleaching powder etc complete all as directed by engr - in -charge, pumping out sewage watersludge from the existing manholes of any size any capacity and any type of material like solidfluid mud sludge etc by mechanical motorised suction machine and deposited removing the sludge etc outside the tech area to a distance exceeding 10 km shall be conveyed in closed container and also disposed off in the place properly using bleaching powder etc complete all as directed by engr - in -charge, cleaning of sewage pipe linecleaning length not exceeding 30 m from man hole or from manhole to septic tank 150 mm to 300mm diabore of pipe by roding and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after clwaning complete as directed by engineer-in-charge, removing blockage of soilwaste drain pipe of any dia cleaning the drain pipe in between floornahani trap to first manholegully trap with water all as directed and directed without damaging the sanitary fittings other installed ci fittings etc to obtain smooth flow of sewagesludge complete all as directed note- supervisor of contractor shall obtain complaint slip from complaint cell in tech area before 1000 hrs daily and feedback should be given daily after completion of job otherwise penalty of rs 150 each per complaint not attended shall be recovered from the contractor complete all as specified and directed, removing blockage of soilwaste drain pipe of any dia cleaning the drain pipe in between wc to first manholes with water all as specified and directed without damaging the sanitary fittingsfixture other installed ci fittings etc to obtain smooth flow of sewagesludge complete all as directed note- supervisor of contractor shall obtain complaint slip from complaint cell in tech area before 1000 hrs daily and feedback should be given daily after completion of job otherwise penalty of rs 100 each for not attended complaint shall be recovered from the contractor complete all as specified and directed, cleaning and removing blockagesludge or any waste materials of 300 mm to 600 mm bore stp np-2 drain pipe line by roding and well flushing by using sufficient water and making it clear for easy flow of water including cleaning of silt etc removing in low lying area complete as directed by engineer-in-charge, excavation in trenches in soft loose soil not exceeding 15 metre deep and not exceeding 15 mtr width and getting out soil including forming bottom surface to required slopegradient for laying cables pipes foundations laying of cable shafts well cesspits manholes etc complete all as specified and directed, returning filling in including spreading leveling watering and well ramming in layers of not exceeding 25 cm thick after the pipes etc are laid jointed tested and foundations complete all as specified and directed by engineer-in-charge, removal of excavated any type of soil to a distance exceeding 250 m but not exceeding 500 m and depositing where directed by engineer-in-charge at a level not exceeding 15 m above the starting point complete all as specified, demolition and breaking up drain pipes of 150mm dia salt glazed stone wareacrccpvc set in cement mortar including bed concrete and removal of debris to outside tech area where directed by engineer-in-chargecomplete all as directed, s f 150 mm bore reinforced concrete drain pipes of class np-2 isi marked with one collar per length of pipe laid and jointed in trenches and jointed in cement mortar 11 complete all as specified and as directed, s f 150 mm bore internal dia salt glazed stone ware pipes grade a laid in trenches on concrete bed to required slope complete all as specified and as directed, m l for cement concrete bed to 150 mm bore drain pipe np2 including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 136 type c-2 using 40mm graded crushed stone aggregate including necessary shuttering and tested of pipes complete all as specified as directed, m l for cement concrete bed to 150 mm bore drain pipe sgsw including packing under and completely surrounding pipe after they are laid and tested in cement concrete 136 type c-2 using 40mm graded crushed stone aggregate including necessary shuttering and tested of pipes complete all as specified as directed, m l for cutting into existing manholes for connecting new drains of 150 dia making good to pipe and rendering cutting out existing benching for and forming branch channel half round or section in cement concrete 124 type b-1 using 20mm graded stone aggregate finished smooth and reforming benching as required 150mm internal dia of pipe complete all as specified and as directed, demolition of stone boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials debris rubbish to out side md land complete all as specified and directed, ml for squarred rubble walling jodhpur type regular coursed well bonded bedded and solidly hearted built in cement mortar 16 complete all as specified and directed, ml for squarred rubble walling jodhpur type regular coursed well bonded bedded and solidly hearted built in cement mortar 16 but except stone complete all as specified and directed, ml precast cement concrete block masonry with solid blocks made of pcc 136 type c1 using 20mm graded crushed stone aggregate exceeding 10cm in width and set in cm 16 complete all as specified and directed, ml for 15mm thick rendering in cement mortar 14 on stone walls or concrete surfaces finished even and smooth without using extra cement mixed with water proofing liquid as per manufacturers instructions complete all as specified and directed note wpc will be measured paid seperately under respective items of boq, demolition and breaking up drain pipes 100mm 75 mm bore pvc salt glazed stone ware ac or reinforced concrete pipe set in cement mortar laid in trenches complete all as specified and directed, s f 75 mm bore pvcswr pipes single socketed in any length with rubber ring joints fixed to wall including pvc clamp properly with pcc 124 complete all as specified and directed, s f 110 mm bore pvcswr pipes single socketed in any length with rubber ring joints fixed to wall including pvc clamp properly with pcc 124 complete all as specified and directed, sf in repair 75mm bore pvc swr bend any radius including jointing with solvent cement complete all as specified and directed, sf in repair 75 mm pvc swr floor trap plain with grating including jointing with solvent cement complete all as specified and directed, sf in repair 110mm bore pvc swr bend any radius including jointing with solvent cement complete all as specified and directed, sf in repair 75 mm pvc swr gully trap 125110 mm setting and jointing with solvent cement complete all as specified and directed, demolition of cement concrete unreinforced in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal unserviceable materials debris and rubbish to a distance outside md land complete all as specified and directed, ml for 75 mm thick plain cement concrete 148 type d-2 using 40 mm graded crushed stone aggregate as in sub base of flooring mass concrete etc complete all as specified and directed, m l for providing and laying 60mm thick factory made chamfered edge cement concretepaver block of m-30 grade with approved colour design pattern as in footpath parks lawns drive ways or light traffic parking etc of required strength thickness size shape made by table vibratory method using pu mould laid in requiredcolour pattern over and including 50mm thick compacted bed of coarse sand compacting and proper embedding laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with fine sand and cutting of paver block as per required size and pattern finishing and sweeping extra sand complete finishing and sweeping extra sand including dismantling of existing paver block complete all specified and directed, m l for providing 35 mm thick precast cement concrete 136 type c-0 using 125 mm graded crushed stone aggregate as in louvers jallies measured solid including all mouldings and including pre-cast frames set in cement mortar 16 complete all as specified and as directed, m l providing precast concrete posts 100x100mm size minimum 75 cm height with pcc 136 type c-0 using 1250 mm graded crushed stone aggregate as in rcc jali post with required reinforced setting in mortar 14 complete all as specified and directed, ml for preparation of newly plaster surface of wall and applying two coats of cement base paint over a coat of cement primer including necessary scaffolding complete all as specified as directed, sf in repair 75mm thick jodhpur type stone slab not exceeding 2m in length machine cut all face along exposed edged size complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
surface excavation nexc 30 cm deep and averaging 15 cm in deep and getting out in any type of soil complete all as specified and as directed, removal of surplus soil to a distance of 250m and not exceeding 500m and depositing complete all as specified and as directed, excavating over areas n exc 15 m deep and getting out in softloose soil complete all as specified and as directed, ml for plain cement concrete 148 type d2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed, returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed, removing excavated soil exc 250 m but n exc 500 m and depositing where directed at a level n exc 15 m above the starting point complete all as specified and as directed, moorumred bajri filling in floors or pavings laid in layers n exc 15 cm thick spread levelled and rammed including watering complete all as specified and as directed, ml for hard core of broken stone or boulders of gauge nexc63mm deposited spread levelled in layers nexc15cm thickness watered and rammed to a true surface complete all as specified and as directed, ml for damp proof course to horizontal or vertical surface including necessary form work 40 mm thick in cement concrete 124 type b-0 using 125 mm graded stone aggregate complete all as specified and as directed, m l for brickwork with subclass b bricks straight or curved on plan exc 6m mean radius with built in cm 16 complete all as specified and as directed, ml for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 14 complete all as specified and as directed, ml rendering 15mm thick on fair face of brick walls or concrete surfaces in cm 16 finished even and smooth without using extra cement complete all as specified and as directed, ml for new plastered surfaces of walls and applying two coats of distemper oil emulsion over a one coat of primer and 3 mm wall putty complete all as specified and directed, ml for preparing newly plastered surfaces of walls and applying two coats of cement based paint complete all as specified and as directed, use and waste of form work to sides of foundationfootings plinth beams and similar work for rough finished surfaces complete all as specified and as directed, use and waste of form work to sides of columns and pillars for for fair finished surfaces complete all as specified and as directed, formwork to sides and soffits of floor or roof beams beam haunchings girders bressummers lintels cantilevers shelves including supports overhangs etc also splays between floors and beams etc complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in footings plinth beams and the like complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in columns and pillars complete all as specified and as directed, ml for reinforced cement concrete m-25 design mix controlled concrete using 20mm graded granite stone aggregate in lintel beams roof beams lintle beams and the like complete all as specified and as directed, mild steel bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 09mm dia or securing with clips complete all as specified and as directed, mild steel bars 5mm dia and over upto and including 10mm dia in stirrups spacers and binders cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 09mm dia or securing with clips complete all as specified and as directed, roof trusses framed trussed purlins crane gantries rails and fastenings and heavy bracket framing beam tee angle channel or flat sections including distance pieces cleats etc cleats etc of ge 410 gde-e-250 quality-a complete all as specified and as directed, plates plain or chequered channels square cut or notched ordinary and counter sunk forming holes without any attachment of ge 410 gde-e-250 quality-a complete all as specified and as directed, sf aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 550mm thick tinted glass fixed with rubber gasket with aluminium heading clips frame made with aluminium box sec as appended below complete all as specified and directed including aluminium wire mess shutter a frame 100x44x148mm thick with rawl plug b middle and lock rail 150x44x148mm thick c bottom rail 100x44x148mm thick d top railstyle 100x44x148mm thick e aluminium beading 07mm thick f aluminium handle d type 150mm long nos-02 aluminium tower bolt-02 99mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper hydraulically regulated designationed no-3 universal type of wt btn 61 to 80 kg-01 g making good of wall surface to match with existing surface complete, sf powder coated aluminium sliding windows frame with movable shutter sliding on minimum two pvc roller of best quality for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and incl 550 mm thick glass stainless steel wire messs fixed with neoprene rubber gasket with aluminium beading clips frame made with aluminium section as appended below- i window frame 63x35mm x 148 mm thick for two tracks ii topbottom rail and style rail of shutter 19x38x148mm thick and over iii aluminium beading - 07mm thick iv stainless steel wire cloth 045mm nominal dia of wire and average width of aperature 140mm and fixed in aluminium window or alongwith fy section fixed with aluminium wire staples complete v aluminium fittings such aluminium suitable handle with auto interlocking closing vi making good of wall surfaces to match with existing surfaces complete all as specified and as directed, ml prepainted galvalume aluminum zinc coating gi based corrugated steel sheet 050mm thick of any colour having tensile strength of 550 mpa as in roof coveringcladding to wall fixed with self tapping screws complete all as specified and as directed, ml prepainted galvalume aluminum zinc coating gi based plain steel sheet 050mm thick of any colour having tensile strength of 550 mpa as in roof coveringcladding to wall fixed with self tapping screws complete all as specified and as directed, ml preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed, m l for 100 mm thick cement concrete type c- 2 136 20mm graded aggregate in plinth protection and finishing surfaces of concrete in sub-floors sub-bases path etcfinished even and smooth without using extra cement complete all as specified and as directed, ml rubber moulded interlocking paver block any shape and size confirming to is 15658 -2006 of 80mm thickness m-40 grade with grey cement and no pigment complete all as specified and as directed, excavation over area n exc 15 m deep and getting out in harddense soil complete all as specified and as directed, ml for pcc 148 type d2 using 40 mm graded stone aggregate as in mass concrete complete all as specified and as directed, m l for walling of random rubble uncoursed well bonded bedded and solidly hearted built in cm 16 complete all as specified and as directed, extra over stone walling for hammer dressing to face stone and dressing of face beds and joints complete all as specified and as directed, m l pcc 124 type b - 1 20 mm graded aggregate cast in situ as in coping incl weathering slightly rounded and champhered angles and throating all as directed, ml for precast cement concrete 136 type c1 using 20 mm graded crushed stone aggregate as in bond stones complete all as specified and as directed, m l flush pointing to random rubble stone masonry in cm 14 uncoursed or brought upto courses complete all as specified and as directed, sf of 110 mm bore pvc swr pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed, removing excavated material n exc 50 m and depositing where directed at a level not exceeding 15m above the starting point complete all as specified and as directed, hand packing any thickness at back of walls over arches etc and raising or lowering to the required level complete all as specified and as directed, a one light pointfan pointex fan point controlled by one 5 amps switch one way, b one 3 pin 5 amp switch socket outlet on independent board, c one 3 pin 5 amp switch socket outlet on same board with accessories, ml for point wiring using proper colour coding complete with 1100 volts grade 25 sqmm single core pvc insulated unsheathed cable with multistranded copper conductor with isi mark frls grade conforming to is-694 in and including pvc medium grade conduitcasing caping not less than 25mm dia isi marked with all accessories concealed in wallceiling floor roof etc with sunk pressed steelgi terminals boxes having 16 mm thick suitable for housing of modular type switchessocketsfan regulators including 25 sqmm pvc insulated unsheathed multistranded copper conductor frls 1100 volts grade green colour as earth wire connected to common earth dolly for switch socket combination 3 pin 15 amps on independent board all as specified and directed, sf switch piano flush type single pole one way 6 amp 240 volts complete all as specified and as directed, sf switch piano flush type single pole 15 amp 240 volts complete all as specified and as directed, sf socket outlet 2 in 1 3 pin 5 amps flush type complete with gang box complete all as specified and as directed, sf socket outlet 2 in 1 3 pin 5 and 15 amps flush type complete with gang box complete all as specified and as directed, supply and fix ceiling rose 3 terminal pvc polycarbonate isolated body complete all as specified and as directed, sf in repairs distribution board spn 8 way double door complete all as specified and as directed, s f in repairs mcb dp 40 amps 240 volts b curve complete all as specified and as directed, s f mcb single pole 6-32a amps 240 volts b curve complete all as specified and as directed, supply and fixing led lights fitting 1x 20w 220v ac decorative box type with driver holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed, ml for supplying and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor served with inner sheathing of pvc tape and overall pvc sheathed in sevice connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire with two single core cables flat or circular 16 sqmm 2 core complete all as specified and as directed, supply and fix building security light led fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with- 25 nos ip 6566 protection complete all as specified and as directed, ml for earthing complete with galvanised steel earth plate electrode 6060cmx 6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not lessthan 15 metres below normal ground level connected to galvanised earth lead wire 40mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed, supply installation testing commissioning of 44 wall mounted gas manifold with nrv copper tail fabricated with high pressure copper of size 58 x 10swg and with is319 brass nrv hydraulic tested at 300 bar degreased copper tail pipe of size 58 x 16 swg hydraulic tested at 300 bar fitted on ms frame middle frame with chain for oxygen without cylinders complete all as specified and as directed hsn code-995415 make - mr, supply installation and commissioning of semi-automatic control panel p c with inbuilt audio visual alarm non return valves for oxygen with copper tubing for connecting manifold to control panel for both sides left bank right bank complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of 1 cylinder emergency wall mounted gas manifold with nrv copper tail fabricated with high pressure copper of size 58 x 10swg and with is319 brass nrv hydraulic tested at 300 bar degreased copper tail pipe of size 58 x 16 swg hydraulic tested at 300 bar fitted on ms frame middle frame with chain for oxygen and with single stage double gauge mox regulator -indian without cylinders complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of british standard nemo safe gas outlets with stainless steel probe oxygencomplete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of metal body bpc flow meter with humidifier bottle 0- 15 litres adult complete all as specified hsn code-995415 make - mr, supply and fix conversion kit with 5 mtr high pressure tubing antistatic for oxygen complete all as specified and as directed, supply installation testing commissioning of vacuum pump simplex with500ltr reservoir tank electrical motor 3phase base frame vacuum pump 5 hp 1 nos make aw ir vacuum receiver tank 500 ltr capacity 1 nos bacterial filter silencer brass fitting complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of british standard nemo safe gas outlets with stainless steel probe vacuum complete all as specified and as directed hsn code-995415 make - mr, supply and fix ward vacuum unit with regulator collection jar of 600 ml with bracket complete all as specified and as directed hsn code-995415 make - mr, supply and fix low pressure tubing - vacuum complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of medical grade bs en 13348 lloyd tested copper pipe indian copper pipe 12 mm od x 07 mm thick complete all as specified and as directed hsn code-995415 make - mexflowrajcommandev, all as per item no 69 above copper pipe 15 mm od x 09 mm thick complete all as specified and as directed, all as per item no 69 abovecopper pipe 22 mm od x 09 mm thick complete all as specified and as directed, all as per item no 69 abovecopper copper pipe 28 mm od x 09 mm thick complete all as specified and as directed, supply installation testing commissioning of line isolation ball valve - indian with both side end fittings 15mm 22mm complete all as specified and as directed hsn code-995415 make - rnrb, all as per item no 73 above copper 22mm complete all as specified and as directed, supply installation testing commissioning of microprocessor based line pressure alarm- digital type for 2 gas service oxygen vacuum complete all as specified and as directed hsn code-995415 make - mr, supply installation testing commissioning of horizontal bed head panel envirom 4 feet long mr-bhp-01 with powder coating and with the following provision gas outlet points 2 nos provision electrical switches socket - 4 nos each not in our scope ward vacuum unit slider stainless steel railing 2 feet long complete all as specified and as directed hsn code-995415 make - mr
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
taking down chowkats or frame with shutter without taking off shutters from the frame exc 15 sqm but nexc 4 sqm each complete all as specified and directed, taking down shutter of any description exc 1sqm but not exc 2 sqm each and removing unserviceable materials from site of work complete all as specified and directed, ml for factory made pressed steel frames 125 x 60 x 125mm thick for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete including pcc 136 type c-0 using 125 mm graded stone aggregate as in filling hollow portion of frame complete all as specified and directed, ml for factory made pressed steel frames 105 x 60 x 125mm thick for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete including pcc 136 type c-0 using 125 mm graded stone aggregate as in filling hollow portion of frame complete all as specified and directed, ml for pcc 136 type c-1 using 20mm graded stone aggregate for embedding of hold fast filling in door frames etc including desterb surfase of existing pogition complete all as specified and directed, ml for 10 mm thick smartcare ready mix plaster for internal surface is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering on bricks block stone walls over a coat of single component polymer as well as concrete surfaces complete all as specified and directed, sf factory made flush shutter 35 mm thick solid core construction with block board core and plywood face panels commercial type complete all as specified directed, sf 35 mm thick factory made llnd class hard wood sal glazed and skeleton shutter open rebated and prepared to receive glass gauze etc with out sash bars edges of framing plain charmfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in ssr part l section 8 clause 824 a supplied and fitted to chowkhats complete all as specified and directed, ml for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface over 10 cm width or girth including preparation of new or previously untreated wood surfaces complete all as specified and directed, ml for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed, sf 100 mm long stainless steel hinges type b-12 and fixed with screw welding complete all as specified and directed, sf stain less steel wire cloth 056 mm nominal dia of wire and average width of aperture 118 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed, sf 200 mm long stainless steel barrel tower bolt of extruded section complete all as specified directed, sf 300mm stainless steel sliding door bolt with hasp staple bolt type and fixing clips of sheet cast or extruded sections and fixing bolts of extruded sections fixed complete all as specified and directed, sf 150 mm long stainless steel handle cast type complete all as specified and directed, sf floor door stopper 150 mm long of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor complete all specified and directed, m l for door seal not less than100 mm width complete all as specified and directed, ml for taking down and refixing in same opening wood shutter exc 1 sqm but not exc 200 sqm including easing adjusting and refixing with same hardware ect, taking down chowkats or frame with shutter without taking off shutters from the frame n exc 15 sqm each complete all as specified and directed, sf of factory made soild pvc door frame of size 50mmx47mm made out of 5mm thick single side prelam pvc sheet reinforced with mild steel square tube supplying fixing in opening as per specification and drawing complete all as specified directed, sf factory made solid pvc moulded door shutter 28 to 30mm thick stiles with 2 4 or 6 raised panel design with 2 mm thick moulded pvc sheet on the front face 2mm plain colour pvc sheet on back face with particle board core supplying fixing in frame at site as per specification drawing complete all as specified and directed, sf 150mm long aluminium anodized barrel tower bolt of extruded section complete all as specified directed, ml 100 mm long aluminium anodized handle cast type complete all as specified and directed, ml for eco-4000 series windows fabricated from roll formed sections made of galvanized steel colour coatedpowder coated base steel as per is 513d quality galvanized as per is 277 with finc of 120 gms sqm with total coated thickness of 060mm sections shoulld be with primer coat of epoxy primer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick section for frame should be of 72mmx50mm section for mullion should be of 72mm x50mm section for shutter frame should be of 47mmx20mm section for fixed glass bead shoulld be of 12mmx12mm and section for fly mesh shoulld be of 40mmx20mm each glazed shutter and mesh shutter shoulld be provided with ss pivot hinges-1 set sec color handle and stay each glazed shutter and fixed glass portions should be provided with a glass of 5mm plain float glass mesh shutter should be provided with stainless steel 32 guage fly mesh of 304 grade with 144 holes per sqin window should be provided with grill made of 10mm sq ms bars welded to at 150mm centre to centre 6mm x 12mm ms flat total grill unit should be powder coated and fixed to window frame with screws complete all as specified and directed, ml for eco-4000 series ventilator fabricated from roll formed sections made of galvanized steel colour coatedpowder coated base steel as per is 513d quality galvanized as per is 277 with finc of 120 gms sqm with total coated thickness of 060mm sections shoulld be with primer coat of epoxy primer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick section for frame should be of 72mmx50mm section for mullion should be of 72mm x50mm section for shutter frame should be of 47mmx20mm section for fixed glass bead shoulld be of 12mmx12mm and section for fly mesh shoulld be of 40mmx20mm each glazed shutter and mesh shutter shoulld be provided with ss pivot hinges-1 set sec color handle and stay each glazed shutter and fixed glass portions should be provided with a glass of 5mm plain float glass mesh shutter should be provided with stainless steel 32 guage fly mesh of 304 grade with 144 holes per sqin window should be provided with grill made of 10mm sq ms bars welded to at 100mm centre to centre 6mm x 12mm ms flat total grill unit should be powder coated and fixed to window frame with screws complete all as specified and directed, sf aluminium powder coated minimum thickness of powder coating 50 micron frames for doors windows ventilators and partition with one or more rebates including joining cleats for fixing etc complete all as specified and directed, s f aluminium powder coated minimum thickness of powder coating 50 micron door window ventilator shutters aluminium section weighing 055kgm including necessary joining cleats glazing clips rubber neoprane packing handles 2 nos in each door leaf hinges 100 mm tower bolt door stopper and 75 mm mortice lock anodised aluminium snap beading screws etc complete all as specified and directed, s f 4mm thick aluminium composite panel one side with decorative choice lamination other side balancing white lamination for cup board shelf fixed with screws to aluminium frame timber framewelding to steel frame work incl all around aluminium beading with rubber gascut complete all as specified and directed, sf 48 mm thick sheet glass ordinary quality and glazing in squares exceeding 05 sqm in each pane complete all as specified and directed, m l for repair of hdhmr high density high moisure resistent both side laminated board of thickness 18 mm exterior grade fixed to timber framebrick concrete surface with screws as incupboard cupboard shelves shutters frames kitchen cabinets including suitable lipping etc complete all as specified and directed, sf continuous piano hinges mild steel bright finish or electro galvanised width of flap when open 32 mm complete all as specified and directed, sf auto closing hinges 35 mm of 0 crank kh-001 or 8 crank kh-002 openable at 110 degree for kitchen cabinet shutters complete all as specified and directed, sf magnetic catcher as in kitchen cabinets cupboards bath cabinets etc complete all as specified and directed, sf in repair stainless steel wire cloth 036mm nominal dia of wire and average width of aperture 140mm and fixed with stainless steel wire staples complete all as specified and directed, ml for welding in repairs nexc 25 cm in length and n exc 6mm thick complete all as specified directed, ml for welding in repair exc 25 cm but nexc 50 cm length and n exc 6mm thick complete all as specified directed, sf in repairs 3 mm thick sheet glass ordinary quantity and glazing with oil putty in square not exceeding 05 sqm in each panel complete all as specified and directed, sf in repairs 3 mm thick figured glass pin headed type and glazing with oil putty in squares not exceeding 05 sq m in each pane complete all as specified and directed, sf in repairs stinless steel drapery rods 25mm internal diameter including decorating type domes including rod holders heavy pattern fixing arrangement with drilling holes in walls supported with brackets etc complete all as specified and directed, sf in repair double action floor spring hydraulically regulated made up of minimum 125 mm thick al alloy sheet foundation box main of brass with stainless steel cover governing pivot made of brass other parts are made of ms heavy duty etc complete all as specified and directed, sf in repair 4 mm thick sheet glass ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares not exceeding 05 sqm in each pane complete all as specified and directed, sf in repairs rubber gasket for aluminium door and window complete all as specified and directed, sfin repairs brass mortice latch 75mm length with four levers vertical type aluminium anodised body complete all as specified and directed, dismantling ms work of any description not otherwise provided for complete all as specified directed, sf in repairs framed work such as grills gratings etc with ends of bars shouldered andor riveted or forget into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work conforming to fe 410-0 or fe 310-0 complete all as specified and directed, sf in repair cast iron door closer hydraulically regulated designation no 3 universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed, taking down and refixing of aluminium shutter in the same position after repairing and making it smooth functional including replacement of unserviceable top pivot and adjustment of floor door stopper size of shutter nexc 250 sqm each replacing including provision of unservicable hinge handle lock aluminium plate floor door stopper complete all as specified and directed, sf in repairs 2nd class hard wood plain fillets square rectangular in section sectional area exe 13 sqcm n exe 25 sqcm clean sawn secured with nails or brads complete all as specified and directed, dismantling of floor hearth or wall tiles terrazomozaicgranite floor dado including cement mortar bedding but not backing removal servicable tiles to store and rubbish off the premises all as specified and directed, ml glazed ceramic coloured tiles of size 450x300x7mm thick as in skirtingdado set and jointed in neat cement slurry and pointed in whitecoloured cement to match in floor over and including 10mm thick cement screed bed of cm 14 complete all as specified directed, ml non skid coloured joint free tiles 7 to 8 mm thick squarerectangular area of each tiles exceeding 011 sqm but not exceeding 018 sqm in floors etcset and jointed in neat cement slurry and pointed in whitecoloured cement to match in floor over and including 15mm thick cement screed bed of cm 16 complete all as specified directed, ml vertified ceramic tiles 10 mm thick squarerectangular area of each tile exceeding not exc 036sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar 16 complete all as specified and directed, ml vertified ceramic tiles 10 mm thick squarerectangular area of each tile exceeding not exc 036sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in cm 14 complete all as specified and directed, demolition of brick work built in cement or cement lime mortar incl all quoins arches pillars etc complete all as specified directed, ml for brick work with sub class b brick straight curved on plan exc 6m mean radius built in cm 16 using old size bricks complete all as specified and directed, taking down of plaster from wall celing and soffits of chajja etc including racking out joints hacking for key scrubbing down with water etc complete all as specified directed, ml for 10 mm thick smartcare ready mix plaster for internal surface is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering on bricks block stone walls over a coat of single component polymer as well as concrete surfaces complete all as specified and directed, ml for 10 mm thick smartcare ready mix plaster for external surface is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering on bricks block stone walls over a coat of single component polymer as well as concrete surfaces complete all as specified and directed, ml for preparation of newly plastered wall surface and applying two coats oil bound distemper a coat of 2 mm thcik wall interior wall care putty and a coat of primercomplete all as specified and directed, ml for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer at any height nexc 11m incl necessary scaffolding centreing etc complete all as specified and directed, sf in repair cupboard drawer channel set complete all as specified and directed, sf in repair stain less steel peg set of six complete all as specified and directed, sf pvc wall lining consisting of 8-10 mm thick wooden grain printed pvc sheet inclusive of solvent cement and fixing channel feathered at the edges for fixing on solid pvc wall lining insulated pvc wall lining at site on wallceiling including dismantling all as per specification and complete all as specified and directed, sf in repair looking mirror 550mm thick of selected quality mounted on pvc frame and back fixed to wall with screw and rawl plugs complete all as specified and directed, sf in repair aluminium alloy anodised 300 mm sliding door bolt with hasp staple bolt type and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed, sf in repair 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed, sf in repair 150 mm long aluminium anodized handle cast type complete all as specified and directed, sf in repair floor door stopper 150 mm long of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor complete all as specified and directed, taking down steeliron door of any size including cleaning adjusting welding steel sheet for repair wire mesh and refixing including all necessary items like hinges sliding door bolt and one coat of synthetic enamal painting etc complete as specified and as directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
kit of consumables for fdg production, radiochemistry cassettes for ga dotanoc and ga psma with reagents compatible with self shielded automatic synthesis module for ga-68 radiopharmaceuticals generator model iqs-ts
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
comprehensive maintenance including preventive and periodical maintenance of installed lift -07 nos of capacity 15 passengers 1020 kgs with speed of 040 ms to 05 ms in reliable safe efficient operating condition through authorised oem or their accredited authorised agencies by regularly examining lubricating and adjusting the eqpt and carrying out planned maintenance in a systematic and controlled manner using technician and expertise and replacement of all unserviceable as per oem term condition and schedule of maintenece provided by the oem including machine and belt equipment covered such as renew all wire ropes and chains where fitted as often required an adequate factor of saftey to equalise the tension on all hoisting ropes repair or replace conductor cables and hoistway and machine room elevetor wiring machine worn gear thrust bearings drive sheves drive sheaves bearing break contact lining and components motor motor generator motor winding rotating elements commutator brushes brush holders bearing coils resistence for operating motors circuits magnet frames and other mechanical parts controller selector levelling devices cams relays solid state components eg pcb transducers resisters condensors power amplifiers transformers contacts leads dashpots timing devices steel selector tapes and mechanical and electrical driving equipment governer governer sheaves shaft assembly bearing contacts and governers jaws car and hall mechanical buttonss car and hall position indicators hall lanterns car direction indication and other car landing signal features deflectors or secondary sheave bearing car and counter weight guide rails automatic power operated, supply installtion and commissioning fire alarm control panel addressable complying with bs en 54 two loop panel of capacity from 99 detectors 99 modules upto 200 detector and modules per each loopcompleted all as specified and as directed, dismantling and taking down carefully circuit wiring any size and making good the disturbed surfaces of wall floor to match the existing wall floor etc complete all as specified directed, material and labour for hose box made of 18 gauge ms sheet 800mm x 600mm x 250mm with double door with 4 mm thick glass and door frame made of 16 gauge ms sheet painted fire red oxide and brilliant white inside yard completed all as specified and as directed, supply and fixing circuit wiring with single core cable 2x15 sq mm pvc insulated unsheathed stranded copper conductor cable 1100 volts grade drawn through existing pvcsteel surfaceconcealed conduit alongwith 1x15 sq mm pvc insulated unheathed copper conductor cable as earth wire connected with complete all as specified and directed, s f in replacement of butter fly valve of size 80 mm dia all completed all as specified and as directed, material and labour for fire extinguishers manual swing type mild steel fire hose reel drum of size 2025 mm dia 30 mtr length with brass nozzle minimum inlet pressure 220kpa maximum working pressure 12 mpa 12 bar side plates sheet steel pwd coated red colour spindle mild steel complete all as specified and directed, rewinding of three phase electric motors of capacity 60 hp with super enamelled copper winding wire as per existing size turns and appropriate gauge including all insulating material ie varnish cotton tape insulating paper and soldering etccompleted all as specified and as directed, material and labour for carrying out maintenance of industrial ro of cap 500 ltrhr model eds-100 ac supply 230v50hz 4kgcm2 with frp tank model-1248 maximum pressure 150 psi controller water purifier by replacement of pre filter candle carbon filter membrane sediment filter etc sleek and carbon block twice in a year and servicing twice after regular intervals including the replacement of circuit board digital ro controller and any other part as required at site to make functional throughout the year completed all as specified and as directed, supply and fixing in replacement of v belt no b-102 for washing machine 50 kg completed all as specified and as directed, material and labour for replacement of branch pipe gun metal 63 mm instantaneous inlet made threaded outlet with 15 mm bore nozzle long completed all as specified and as directed, supply and fixing in replacement of v belt no b-100 for washing machine 60 kg completed all as specified and as directed, supply and fixing in replacement of v belt no b-72 for drying tumbler 60 kg completed all as specified and as directed, supply and fixing in replacement of v belt no b-64 for washing machine 50 kgs completed all as specified and as directed, supply and fixing in replacement of 12v 7 ah sealed maintenance-free smfvalve regulated lead acid vrla battery of required capacity suitable for automatic rescue device ard of passenger lift all as specified and directed, supply and fixing in replacement of telephone set sleek model completed all as specified and as directed, supply and fixing in replacement of jelly field cable 10 pair for making connections in existing system of epabx all as specified and directed, ml for repair of washingsluicing machine cap upto 15 kgs by replacement of door gas kit glen dori belt etc completed all as specified and as directed, supply and fix in repair of steam boiler burner rod assembly with replacement of photocell cem-8205 solenoid coil ignition electrode and ignition transformer electrode cap diffuser plate burner gauge nozzel denfoss completed all as specified and as directed, supply and fix in repair of steam boiler steam line spares main stop valve-12 safety valve 1112 pressure gauge 025 kgcm2 complete all as specified and directed, supply and fix in repairs of steam boiler water pump spares gasket packing circlip washer packing oil ring bearing set oil seal connecting rod piston complete all as specified and directed, supply and fix in repair of steam boiler water line spares booster pump filter element pressure gauge 0-25 kgcmv 2 mettalic hose 112 m complete all as specified and directed, supply and fix in replacement of elevator cabin fan of passenger lift 15 person ac 230 volt five blade model gf-300a 53w 1300 rpm of air flow 1100 m3h of 40 db complete all as specified and directed, supply and fix in repairs of steam boiler fuel line spares oil seal-aj6 o ring - aj6 simplex oil filter filter element sealing ring complete all as specified and directed, supply and fix in repair of steam boiler control panel board by replacement of its accessories like safty switches contol cable fire alarm steam pressure switch digital temperature display lit switches with high quality lamps atmospheric economiser burner safty valve sensor complete all as specified and directed, supply and fix in replacement of steam boiler tubes coil made with hot rolled seamless carbon and alloys nickel of steam boiler non-ibr type of cap 600 kghr having reverse fuel technology completed all as specified and as directed, ml for replacement of lower ducting of steam boiler cap 600 kghr completed all as specified and as directed, ml for replacement of upper ducting of steam boiler cap 600 kghr completed all as specified and as directed, ml for repalcement of fuel pump of steam boiler of cap 600 kg hras per secified and directed by eng-in-charge, ml for repalcement of water feed pump of steam boiler of cap 600 kg hr as per secified and directed by eng-in-charge, supply and fix in replacement of metalic non-return valve of size 25 mm of steam boiler all as specified and directed, supply and fix in replacement of eonomiser for the steam boiler cap 600 kgshr by taking out the defective by opening the nuts bolts washers and fixing fixing new one in existing position suitable for thermax make steam boiler complete all as specified and directed, supply fix mono block pumping set of cap 05 hp ac 230 v along with pvc connection pipe of 20 mm dia 10 mtr long all as specified and directed, supply and fixing in replacement laundry timer 0-60 minutes completed all as specified and as directed, sf in replacement of mcb tpn 32 amp c series all as specified and directed, electric hand press heavy duty suitable for laundry commercial type 1250 watt operated on single phase ac supply with suitable size electric cord 2 mtr long all specified and directed, ml in replacement of steam radiator with stainless steel tube and aluminum pulley suitable for drying tumbler 60 kg as per sample complete all as specified and directed, ml in repair ms sheet 2 mm thick for replacing casing of boiler steam coil tubing cut to size and made to shape as per site requirment including cutting welding etc for boilers complete all as specified and directed by engr-in-charge, rewinding of three phase electric motors of capacity 2 hp3 hp with super enamelled copper winding wire as per existing size turns and appropriate gauge including all insulating material ie varnish cotton tape insulating paper and soldering etc all as specified and directed, rewinding of three phase electric motors of capacity 5hp75 hp with super enamelled copper winding wire as per existing size turns and appropriate gauge including all insulating material ie varnish cotton tape insulating paper and soldering etc all as specified and directed, rewinding of three phase electric motors of capacity 10 hp with super enamelled copper winding wire as per existing size turns and appropriate gauge including all insulating material ie varnish cotton tape insulating paper and soldering etc all as specified and directed by engineer-in-charge, repair of microprocesssor based plc programmable logic controller of washing machinedrying tumbler with replacemnt of burnt parts such as timers diode capacitors and checking of all electronic circuits with proper instruments and made it functional completed all as specified and as directed, ml for repair and servicing of washing machine of cap 60 kgs front loading incl replacement of defective parts if needed all as specified and directed note cost for replacement of defective parts has been measured and paid under relevent items completed all as specified and as directed, 3 motor pulley completed all as specified and as directed, 16 motor bush pulley completed all as specified and as directed, bearing-22210 completed all as specified and as directed, bearing slip-22310 completed all as specified and as directed, bearing-22215 completed all as specified and as directed, bearing slip-22315 completed all as specified and as directed, glen dori oil seal completed all as specified and as directed, door gaskit completed all as specified and as directed, inner basket repair completed all as specified and as directed, ml for repair and servicing of of hydro 25kgs capacity incl replacement of defective parts if needed all as specified and directed note cost for replacement of defective parts has been measured and paid under relevent items, rubber buffer completed all as specified and as directed, hydro spring completed all as specified and as directed, limit switch completed all as specified and as directed, push botton with nc 0-15 min timer completed all as specified and as directed, brake plate completed all as specified and as directed, 1 kva transformer completed all as specified and as directed, delay off timer completed all as specified and as directed, ss lock completed all as specified and as directed, repairreplacement of air compressor of motor capacity 5 hp with auto cut motor type three phase ac 415 volts no of cylinder 02 tank 280 ltrs cfm 302 pressure 500 pound complete all as specified and directed, ml for repair and servicing of sluicing machine of cap 7 kgs front loading incl replacement of defective parts if needed all as specified and directed, repairreplacement of wetdry linen trolly stainless steel body of size 990mmx600mmx660mm complete with wheels all as specified and directed, repairreplacement of touch control panel led bulbs convertor of operation theatre lights model sims prima 96r all as specified and directed, ml for replacement of defective indion resin 220 na softner sn cod 3914 of existing water softening plant completed all as specified and as directed, supply fix mpv 40 nb side mounted sft sn cod 8421 of water softening plant complete all as specified and directed, supply only water hardness kit 500bx sn cod 3822 for water softening plant complete all as specified and directed, ml for repair of ups of capacity 10-20 kva by repair replacement of insulated gate bipolar transistor igbt dc capacitor scr module logic board diaod transisters protection board or dc converter circuit board 3 phase of suitable rating complete all as specified and directed, ml for repair of ups of capacity 2-5 kva by repair replacement of insulated gate bipolar transistor igbt dc capacitor scr module logic board diaod transisters protection board or dc converter circuit board 3 phase of suitable rating complete all as specified and directed, material and labour for pressure testing of cylinder and refilling of fire extinguisher co2 type of capacity 65 kgs alongwith replacement of nozzle and hose as existing all as specified, material and labour for pressure testing of cylinder and refilling of fire extinguisher co2 type of capacity 45 kgs alongwith replacement of nozzle and hose as existing all as specified, material and labour for pressure testing of cylinder and refilling of fire extinguisher co2 type of capacity 9 kgs alongwith replacement of nozzle and hose as existing all as specified, material and labour for pressure testing of cylinder and refilling of fire extinguisher abc type of capacity 5 kgs alongwith replacement of nozzle and hose as existing all as specified, supply fix in replacement of pressure release valve of size 25 mm dia for laundary plant as per existingcompleted all as specified and as directed, sf in replacement of detectors complying with and type certified to en-45 addressebale type multisensor detectors with heat and smoke combination photoelectricoptical with base with self built intelligenceas per is-11360 all as specified and directed, sf in replacement of fire alarm sounders sirens electronic type horizontal single stage continious normal opeartion for atleast 50 minutes with sound level 65 db to 120 db measured al 15 mtr with sound output variation of 5 db of range 500 mtr all as specified and directed, sf in replacement of addresseble manual call point resetteable type for fire alarm system all as specified and directed, material and labour for cutting dismantling of existing ms steam pipe line with insulation and providing new ms steam pipe line 50 mm bore medium grade for making connections to the machines with cutting making pieces including neccesary fittings and welding complete all as specified and directed, ml for descaling of steam boiler of cap 600 kgs by descaling media sri-s2 liquid boiler descaling chemical standard grade or by liquid sulfamic descalant is a liquid chemical substance used to remove limescale from metal surfaces in contact with hot water complete all as specified and directed, ml for old painted or treated untreated steam boiler surface with heat resistance aluminium paint films of paint prepared and tested shall show no cracking blistering flaking or peeling complete all as specified and as directed, ml for old painted or treated untreated iron pipes of size 80100150 mm dia of fire fighting plant and applying two coats of oil based paint of red in colour and as directed over a coat of red oxide zinc chrome primer complete all as specified and as directed, supply and fixing stainless steel globe valves with side handle half turn operated isi marked screwed both ends for iron pipe of size 50 mm bore all as specified and as directed, supply and fixing stainless steel globe valves with side handle half turn operated isi marked screwed both ends for iron pipe of size 40 mm bore all as specified and as directed, supply installation testing and commisioning automatic rescue device ard part id 529 system complete for lift of make ece completed all as specified and as directed, ml for stainless steel braided connection pipe of size 2025mm of length 15 mtr all as specified and directed, supply and fixing in replacement of defective hydro bush anti-vibration rubber bush suitable for industrial laundry plant complete with dismantling of old bush fixing new bush all as specified and directed, m l for servicing of flat bed press laundry plant comprising complete dismantling of accessible covers thorough cleaning of machine removal of lint dust and carbon deposits from heating chamber electrical panel and mechanical components cleaning of upper heated head and lower buck checking and tightening of all nuts bolts and fasteners inspection and lubrication of bearings bushes hinges guide rods and other moving parts with approved grade lubricant checking and adjustment of pressure mechanism pneumatichydraulic system including cylinders hoses valves and fittings for proper operation all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
disconnecting dosing plant any model any capacity alongwith components dismantling and segregation of all parts for repairreplacement of defective part cleaning washingreassembling the plants connecting in position and testing complete all as directed by engr-in-charge spares will be measured and paid under item no 02 to 13 note - all the repairs required and pertain to dosing plant shall be carried out ensure at the concern installations by the contractor rep upto smooth functioning of the same non taken over site by the contractor and delay in repair if noticed the recovery shall be made rs 500- per day from contractor bill till complete the job because of unchlorinated water cannot be supplied to the troops complete all as specified and directed by engr-in-charge, supply only suction valve assy complete of dosing plant liquid end as per sample, supply only discharge valve assy complete, supply only diaphragm for dosing plant liquid end as per sample, supply only foot valve assembly for dosing plant liquid end as per sample, supply only nrv assembly for dosing plant as per sample, supply only head for dosing plant liquid end as per sample, supply only tubing for dosing plant including all accessories liquid end as per sample, supply only injector valve including fitting as per sample, supply only pcb for dosing pump as per sample, supply only impeller of agitator blade made of pvc all as per sample, supply only extended agitator shaft of non-corrosive material all as per sample, supply only complete set of o rings, dismantelling of old burnt motor of dosing plant 960 rpm and rewinding with super enamelled copper wire with replacing all unserviceable parts of motor for making it as serviceable including fixing new ball bearing etc complete all as specified and directed by engr-in-charge note - spare part shall be included in quated rate, repairreplacement of chemical decrin dosing pump model no c 24121 non-metalic diaphragm type for injection of dixinfection of water treatment injection capacity 145 lph type magdomd2040 having 145 lph at 13 kgcm2 bar discharge working pressure solenoid driven electrically control 220 volts maximum current 01 amps with ip 65 protection and f class insulation with standard fittings with stoke length suitable from 0-100 and stock frequency suitable from 0-to 100 minimum included all accessories such as football line injection valve suction valve deliveryvalve and pe tubing consistencey in performance complete all as specified and directed by engr-in-charge make - jescodeclibac, supply and filling in dozing plant calcium based high strength chlorination chemical for water disinfectant in granular form in factory sealed hdpe container 40 to 50 kg each chlorine concentration level 65-70 complete all as specified and directed, supply and filling in dozing plant calcium based high strength chlorination chemical for water disinfectant in granular form in factory sealed hdpe container 40 to 50 kg each chlorine concentration level 90-99 suitable for chlorination of swimming pool water tcca-90 complete all as specified and directed, supply only soda ash crystal grade 1 of best quality incorporated for improvement of swimming pool water complete all as specified and directed, supply only alam crystal grade 1 of best quality incorporated for improvement of swimming pool water complete all as specified and directed, supply only copper sulphate crystal grade 1 of best quality incorporated for improvement of swimming pool water complete all as specified and directed, ml for bacteriological and chemical analysis of water sample of borewell water from director of health services environmental and pollution control wing pathankot note - a the water sample shall be carried in sterilised bottlewatercan which will be issued by director of health services environmental and pollution control wing pathankot b the rate quoted shall be deemed to includingude transportation cost cost of sterilised bottle, supply installation in replacement of old dosing tank model no- ads-1 having 100 ltrs frp tank with inbuilt motor and agitator capacity 100 ltrs mocpefrplid containing port hole for pouring chlorination chemical and water when necessary provision for mounting of motor at proper angle provision for mounting dosing pump on lid level gauge make - declibacaquafitpurichlor, ml for repair of solar water heater capacity upto 200 lpd after carefully opening of different tubes electrical connection and unscrewing of nuts and bolt from foundation refixing the same after cleaning and serviceable complete all as specified and directed, ml for repair of solar water heater capacity upto 1000 lpd after carefully opening of different tubes electrical connection and unscrewing of nuts and bolt from foundation refixing the same after cleaning and serviceable complete all as specified and directed, supply and replacement 3 layer pp-r polypropylene random copolymer concealed pipe 25mm dia sdr 74pn-16 uv stablised and antimicorobial fusion welded having thermal stability for hot and cold water suppy all pp-r plain brass threaded polypropylene random fittings laid in trenches including taking out all as specified and directed by engr-in-charge, supply and replacement 3 layer pp-r polypropylene random copolymer concealed pipe 20mm dia sdr 74pn-16 uv stablised and antimicorobial fusion welded having thermal stability for hot and cold water suppy all pp-r plain brass threaded polypropylene random fittings laid in trenches including taking out all as specified and directed by engr-in-charge, sf in replacement of broken flat collector plates tinted glass of solar panel length and size as per existing sample new one including lifting from floor to roof of the building by manually or mechanically is included in the coated rates complete all as specified and directed, m l for rubber flexible hose pipe of dia as per existing heat resistance type suitable for solar plant of diff capacity with suitable clamps nut and bolts complete all as specified and directed, supply and replacement evacuated heat tube of any size by taking out the broken tube complete, supply and replacement pp-r gate valve brass inserted 25mm dia, supply and replacement pp-r gate valve brass inserted 20mm dia, supply and replacement rotation moulded polyethylene water storage tank cylinderical vertical with closed top hoisted and fixed in position of capacity 500 litre including taking down unsv broken tank, s f tank nipple after making proper hole in inlet and outlet portion all as specified, s f 20mm dia brass ball valve high or low pressure with plastic floats and iron rod complete all as specified and directed, supply and replacement of heating element 3000 watt for solar water heater, supply and replacement of thermostat suitable for solar water heater, supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable with pvc insulated 3 core stranded copper conductor served with an inner sheathing of pvc tape pvc sheathed 25 sqmm nominal cross section in service connectionlight connections in solar water heater including taking out old unserviceable cable complete all as specified and directed by engr-in-charge, supply and fix or laying in trenches pvc pipe 25 mm dia heavy duty for cable protectionfixing of garden lights etc of the following sizes including necessary teeelbowjunction box etc provision for cable entry if reqd in garden lights complete including taking out old unserviceable pipe as required complete all as specified and directed by engr-in-charge, repair to washing machine hydro extractor of cap 30 kgs 3 ph 415 volts 50hz ac complete and after completion of work testing of the machine all as specified and directed by engr-in-charge note - defective major componentsspares elaborated hereafter in respecive item of schedule shall be measured as supply only, supply only ls contactor 3 pole 220 volts suitable for 30 kgs, supply only selector 800 smr complete for dryer of capacity 30 kgs as per sample, supply only iblar sleeves for 30 kgs washing machine as per sample, supply only iblar bearing for 30 kgs washing machine as per sample, supply only single phase preventor suitable for 30 kgs washing machine as per sample, supply only relay 25 amp to 6 amp for dryer machine motor as per sample, supply only stainless steel spring assy for 30 kgs laundry machine as per sample, supply fixing of the following parts for washing machine hydro extractor of cap 25 kgs and tumbler drying machinme 25 kgs three ph 415 volts 50 hz ac complete and servicing greassing and gland dori for motor and testing after completion of work all as specified and directed by engr-in-charge note - defective major componentsspares elaborated hereafter in respecive item of schedule shall be measured as supply only, supply only iblar bearing for 25 kgs washing machine as per sample, supply only single phase preventor suitable for 25 kgs washing machine as per sample, supply only pressue switch suitable for 25 kgs washing machine as per sample, supply only pressue switch pipe suitable for 25 kgs washing machine as per sample, supply only door openclose sensor for loundry machine dryer of capacity 25 kgs as per sample all as specified and directed, supply only stainless steel spring assy for 25 kgs laundry machine and dryer assy as per sample all as specified and directed, s f in repairreplacement of retro reflective informatory sign board of size 900x600 mm made out of 3 mm thick aluminium composite sheet both faces to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as per sample with necessary led lights and provision of electric wiring including connection etc complete of suitable size copper wire letter symbols borders etc as per requirement will be as per irc -67 with required colour scheme on the boards with the high intensity grade a ss sheet to be rivetedwelded to stainless steel squre frame of 30x30 mm and fixed on top of the ph bldgs with support of ss pipe 304 grade round square as per required length the board will be fixed welded to the frame and fixing ph bldgs with pcc 136 after necessary earth work complete all as specified and directed, overhauling and repair of 3 phase 50 hp 37 kw re-circulating centrifugal pump set swimming pool of any make by disconnecting electricalmechanical connection taking up motor from foundation transporting to workshop to carry out repairs replacement of minor unserviceable componentsspares like suctiondischarge nozzle oil rings casing wear ring shuffing box throttle bushing wear rings nuts bolts washer etc including necessary lathe work welding metaling turning polishing repair of housing case of dende side reassemble all the parts componants refix at same position in alignment reconnection re-commissioning and testing to ensure efficient and smooth functioning to achieve desired discharge of pump complete all as specified and directed note i defective major componentsspares elaborated hereafter in respecive item of schedule shall be measured as supply only ii cost of minor spares and welding work etc as mentioned above are included in the quoted rate, supply and fixed mccb 250 amps 4 pole 36 ka adjustable type magnetic setting and fixing in exisiting db and making connection with cable by means of suitable size of thimbles complete all as specified and directed, supply and fixed mccb 400 amps 4 pole 35 ka adjustable type magnetic setting and fixing in exisiting db and making connection with cable by means of suitable size of thimbles complete all as specified and directed, ml for rewinding of 3 phase electric motor of 50 hp 37 kw re-circular centrifugal pump swimming pool with super enamelled copper winding wire of same gauge including impregnated paper sleevs lathorised fibre glass varnish and tape etc complete all as specified and directed, supply installation commissioning and testing star delta starter suitable for 50 hp ml4f motor relay range 30 to 50 amp including single phase preventor fully automatic in sheet metal enclosure type ac 3 phase 415 volts 50hz including taking out old unsv starter complete all as specified and directed make ltabb havells or equivalant as approved, supply and fixing cast iron non return valve 150 mm bore dia flanged ends drilled holes including jointing material such as rubber gasket bolts nuts and washers of suitiable size complete all as specified and directed make - ltupadyayzoloto, supply and fixing cast iron sluice valve 200 mm bore dia with steel spendle and ci wheel flanged ends drilled holes including jointing material such as rubber gasket bolts nuts and washers of suitiable size complete all as specified and directed, all as per item no 61 above but 150 mm bore dia, repair overhauling of suction swipper machine mono block upto 2 to 5 hp by replacing worn out gland packing gasket bearing bushes gasket bearing bushes scraping out of pump casing bolts nuts washers etc cleaning greasingh tightening of bolts nuts including painting with one coat of synthetic enamelled paint to pump only re-installation including alignment with motor testing complete all as specified and directed, sf nylon brush 50cm x 70 cm for swimming pool conform to sample complete all as specified and directed, sf nylon brush 80cm x 75 cm for swimming pool conform to sample complete all as specified and directed, ml for pvc insulated 3 core 6 sqmm copper submersible flat cable and making necessary connection complete all as specified directed, sf in repair sheet metal enclousures of single pole neutral with two pin and earth plug socket with 20amp 240v mcb for solar water heaters complete all as specified and directed, sf in repair for circuit submain wiring alongwith earth wire size 2x25 sqmm 1x 25sqmm of fr pvc insulated copper conductor 2 core cable in surface recessed through 20mm bore pvc pipe fixed on wall with clamps as required complete all as specified and directed, sf 15mm bore dia bib taps long body cast copper alloy chromium plated fancy type isi marked as per sample with crutch or butter fly handles screwed down screwed for iron pipe complete all as specified and directed, sf framed work such as grills gratings etc with ends of bars shouldered andor riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work conforming to fe290gde-e-165 complete all as specified and directed, ml plain cement concrete 148 type d2 using 40mm graded crushed stone aggregate as in poles and mass concrete etc complete all as specified and directed, sf in repair solar water heater tank of capacity 200 ltrs including puf insulation made out of ss-304 ss-316 material as per sample complete all as specified and directed, ml in repair leakage of solar water tank providing welding work re-coating as required at site complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
taking down of existing double reduction gear box with impellerpaddie fan shaft assemebly complete coupled with 3 phase 415 v electric induction motor up to 1hp mountain on common ms base framestructure and deposited to mes yard of ge army jamnagar complete all as specified and directed by engineer-in-charge, taking down of existing triple reduction gear box with impellerpaddie fan shaft assemebly complete coupled with 3 phase 415 v electric induction motor 3 hp mountain on common ms base framestructure and deposited to mes yard of ge army jamnagar complete all as specified and directed, repair and overhauling of existing alum mixermixing chamber including complete cleaning and removal of sludge deposited alum loose concrete damaged plaster and unwanted materials from the chamber and surrounding area cleaning and preparation of internal surfaces carrying out necessary pcc repair to damaged portions repairing cracks honeycombed and damaged concrete surfaces with suitable cement mortarrepair mortar providing cement plaster to internal surfaces wherever required providing suitable waste-water outlet arrangement for draining the accumulatedwaste water from the chamberdrain including making necessary opening in the existing wall providing suitable size giupvc pipe outlet with heavy-duty tapvalve socket bend coupling and other required fittings properly sealed and grouted in the wall including necessary civil work testing and making good the surrounding surface complete all works shall include labour materials tools and tackles scaffolding transportation debris removal curing and finishing complete in all respects as required for satisfactory operation of the alum mixing system complete cleaning and making the chamber fit for operation, m l for cleaning and plaster repair of two side drainage channels each approximately 1000 m long 005 m wide including removal of sludge silt and deposited material surface preparation pccrepair wherever required cement plaster to sides and bottom proper slope towards outlet curing and complete cleaning, m l for systematically inspecting disassembling and replacing worn internal gear bearing and seals of double reduction gear box having two-stage reduction ratios of 301 and 251 giving an overall reduction ratio of 7501 complete with heavy-duty cast ironsteel housing hardened alloy steel gears precision machined shafts bearings oil seals lubrication arrangement inspection cover and all necessary accessories coupled with 1 hp 3-phase induction motor suitable for 415 v 50 hz ac supply complete with flexible coupling coupling guard ms base frame foundation bolts alignment lubrication oil and all necessary accessories including installation testing and commissioning complete as required and directed, m l fo systematically inspecting disassembling and replacing worn internal gear bearing and seals of triple reduction gear box comprising three-stage reduction arrangement with individual reduction ratios of 601 501 and 151 giving an overalltotal reduction ratio of approximately 45 0001 complete with suitable heavy-duty cast ironsteel housing hardened alloy steel gears shafts bearings oil seals lubrication arrangement inspection cover and all necessary accessories coupled directly with 2 hp electric indicator motor suitable for 415 v 3-phase 50 hz supply complete with flexible coupling base frame foundation bolts alignment lubrication oil and all accessories as required and directed by engineer-in-charge, m l for supply laying jointing commissioning and testing of ms erw flanged pipe heavy grade isi marked of 100 mm bore as in network for filter water back wash air grid piping perforated type 3mm dia drilled hole in every 100mm in zig zag pattern for rapid filter tank laterals by making necessary holes as directed and header connecting filter beds and fitted with existing pipes including all required modification for connection by required mscidi fittings with including epoxy painting of external surfaces fitted at filter bed as per standard design specifications including taking up or down existing ms pipe of 100mm bore of any description complete all as specified and as directed, ml for pcc 124 type b2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified and directed, m l for cleaning of area around filter plant including removal of bushes grass weeds rubbish loose earth debris and other unwanted materials uprooting of vegetation collection and disposal of waste to approved dumping place dressing spreading and leveling of existing earthsoil including filling of minor depressions cutting of high spots rammingcompaction and making the area even and suitable for proper drainage complete as directed by engineer-in-charge, m l for providing and laying factory-made cement concrete interlocking paver blocks of approved quality 80 mm thick of approved colour shape and pattern over prepared sub-grade including dressing and leveling of ground providing and compacting granularsub-base as required laying and compacting 4050 mm thick coarse sand bedding laying paver blocks to required line level and slope filling joints with clean fine sand mechanical compaction with plate vibrator cutting of blocks at edges and all incidental works complete as directed by engineer-in-charge
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
supply and fixing automatic erosion feed enabled water sanitiser conditioning treatment station with proportional dosing arrangement consisting of complete all as specified and directed1 receptacle with following attachments- a station holding assembly b water inlet regulator c overflow vent d drain valve e fluid level controller with in-built level switch f sludge level gauge g station base assembly with station base buffer h material of construction non-metallic thermoplastic i maximum temperature 45c j capacity 100 litres k shape cylindrical 2 station hood assembly with multi-cavity arrangement as under- a custom cover b refill cavity lids c electrically powered drive unit with pressure resistance up to 10 bars d maximum discharge 100 lph e material of construction non-metallic f maximum temperature 45c g shape circular h cavity lids storage bin3 automation assembly with accessories, supply only hermetically sealed single-use polymeric sanitisation module optimized for delivery in aqueous media via chlorine-based solid oxidizing matrix must be designed for seamless integration with both active and passive-flow dosing systems ensuring precision-controlled disinfectant release into potable water additionally an integrated suspension loop must enable direct stand-alone deployment without auxiliary apparatus key attributes construction chemically inert thermoplastic housing a stabilized chlorine medium for sustained disinfection dispersion hydro-actuated hermetically sealed orifice that activates on immersion for contactless chlorine delivery safety non-contact non-volatile design compliant with closed-loop potable water protocols service life dual-mode diagnostics via visual and gravimetric indicators for replacement dimensions diameter 25 05 height 100 05, supply of calcium based high strength garnular calcium hypochlorite with chlorine content of 65 to 70 in standard sealed pack of 45kg drum suitable for disinfectant chlorination of drinking water as per the following generic specification complete all as specified and as directed by engineer-in-charge a chlorine content 65-70 by massb particle size passing through 170mm is sieve- 99 by mass minimumc water insoluble matter- 6 maximumd calcium hydroxide- 4 maximum e sodium chloride- 15 maximumf loss of chloride on basis of available chloride- 115 maximum, supply of non-feric alum grade-i white in colour in standard sealed pack of 20-25kg bag suitable for disinfectant of drinking water complete all as specified and as directed by engineer-in-chargenote for sl item no 3 4 9a contractor shall submit purchase voucher alongwith manufacturer and independent test certificates from govt approved test lab for every batch of supply quoted rates are inclusive of testing charges b each pack container bag of chemical shall be duly embossed with make of manufacturer batch no date of manufacturing and date of expiry c supplied chemical must have self life not less than 04 four monthsd total consignment shall be supplied in various installment as directed by engineer-in-charge, ml for collecting water samples from pump houses of the station and carrying out testing through any goverement authorised laboratory agency for chemical and bacteriological examination of potable water conforming to is 10500 water samples shall be collected in properly sealed plastic containers of 02 ltrs capacity and transported safely to the authorised testing laboratory and the cost of transportation handling submission collection of reports shall be deemed to be included in the quoted rate the item includes obtaining and submitting test reports for the following parameters for each pump houses- i ph testii total dissolved solids tds test iii coliform test microbiological testiv total hardness testv calcium hardness testvi fluoride testvii iron test, supply only orthotolidine solution in glass container suitable for testing of chlorine content in water all as specified and directed by engineer-in-charge, supply of chlorine testing reagent dpd tabletsregents for measurement of residual chlorine complete all as specified and directed by engineer-in-charge, supply only digital ph meter table top display-35 digit led range-0 to 140 ph mv 0 to -1999 accuracy - 001 ph mv -1mv slope control- 80 to 120 power 220230v ac sensor- ph electrode complete all as specified and as directed, supply of stable bleaching powdergrade-i confirms to is-1065 part-i 2019 in 25 kg factory sealed container drums the bleaching powder should be free from lead and must have cias corrosion inhibitor anti scalant that is suitable for treatment of drinking water all as specified and directed, cleaning of chlorine solutions prepration tanks mixing drums and dosing tanks servicing of chlorination equipment injectors dosing lines and valves including removal of sludge washing removal of deposit and making serviceable and calibration complete all as specified and directed by engineer-in-charge, sf in replacement of chemical pvc storage tank of capacity 100 ltrs for mixing of chemical in dosing pump matching with existing sample complete all as directed and specified by engr-in- charge, supply fix in replacement of motor agitator including shaft blades etc for chlorine dosing system matching with existing sample complete all as directed and specified by engineer-in-charge, s f in replacement high density polyethylene pipe hdpe having pressure rating 6kgfcm2 fixed complete to walls ceilings or in floors from dosing pump to chlorine feeding point matching with existing sample complete all as specified and directed by engineer-in-charge, sf in replacement non return valve suitable for dosing system matching with existing sample complete all as specified and directed by engr-in-charge, supply and fix foot valve assembly suitable for dozing pump complete all as specified and directed, supply and fix single head feed rate controller with shaft suitable for dozing pump complete all as specified and directed by engineer-in-charge, m l for servicing and repair of chemical dosing system plunger type suitable to inject solution upto 25 lph complete with repairrewinding of dosing pump coupled with single phase electric motor of capacity 05 hp 1440 rpm assembly with agitator complete unit with replacement of chemical grade pvc nrv pvc pipe as per existing size required at site complete all as specified and directed by engineer-in-charge, ml for prepartion of old concreteplastered surfaces by scrapping brooming etc and applying two coats of exterior emulsion weather proof paint apex of asian paints or equivalent over dome wall columns beam including applying two coats of synthetic enamel paint on all pipe line etc of overhead reservoir using scaffolding and necessary safety precaution complete all as specified and directed by engineer-in-charge for the following rcc over head reservoir -a rcc overhead reservoir 10000075000600005000040000 gallon capacity 60 to 100 feet staging i rising main - blue colourii delivery main - green colouriii wash out main - red colouriv over flow main - yellow colour, supply and fixing in replacement of bleaching dozing pump with motor agiator including shaft blades etc for chlorine dosing system with pvc storage tank of capacity 105 ltrs for mixing of chemical in dosing pump suction and delivery tubing injection assemebly foot valve level switch if required electrical connection and mounting arrangement including inlet and outlet connection with pipe line used for treatement of water all incidental works like proper base for storage tank labour materials required for satisfactory operation complete all respects as per site requirement and direction of engineer-in-charge make declibac poter watts corp briozing unlimited, taking up or down steel tubing pipe including connected items and connections complete all as specified and directed for the following bore of pipes- a 15 mm bore, b 20mm bore, c 25mm bore, s f gi tubing medium grade with and including all fitting and fixtures laid in trenches or fixed on walls complete all as specified and directed for the following bore of pipes- a15 mm bore, b 20mm bore, c 25mm bore, s f following sizes of gate valve gun metal screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete and all as specifieda 25 mm bore, b 20 mm bore, c 15 mm bore, taking out old unserviceablecorroded out valve pit ms cover of valve pit size 90cm x 90cm lxb and replace same with new valve pit cover made of 315mm thick ms back sheet welded to 40x40x6mm equal angle at sides and diagonals for making resting base frame both resting frame and cover should be hinged at two points along one side including necessary locking arrangement and painting complete all as specified and directed by engr-in-charge, taking out old unserviceablecorroded out valve pit ms cover of valve pit size 60cm x 60cm lxb and replace same with new valve pit cover made of 315mm thick ms back sheet welded to 40x40x6mm equal angle at sides and diagonals for making resting base frame both resting frame and cover should be hinged at two points along one side including necessary locking arrangement and painting complete all as specified and directed by engr-in-charge, supply and fixing lt panel board indoor type factory fabricated with cpri approved with rubber gasket and locking arrangement vermin dust weather proof self ventilation with wire mesh at suitable interval on both side totally enclosed bus bar chamber fully comparted type both side openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick crca sheet duly powder coated paint factory made cpri approved 415 volts tpn 50 hz with both sides properly welded ms angle 50x50x6mm 4 nos at all vertical corners grouted in pcc 136 type c-1 using 20mm graded stone aggregate and connecting the incoming out going feeders by providing cable lugs complete all as specified and directed of suitable size for comprising of following accessories panel shall comprise the following - incomer i on load change over switch 4 pole capacity 200 amp with rotory handle - 01 no ii mccb tpn 415 volt 50 hz ac 200 amps 36 ka with 4 pole adjustable thermal fixed magnetic setting with onofftrip indicatorand spreaders phase barrier- 01 no iii digital vaf meter with volt ampere frequency selecter switchiv led indicator ryb 1 setv ct coil 1505 amp- 3 nos vi tpn aluminium bus bar 500 amp rating capacity out going a mccb tpn 415 volt 50 hz ac 160 amps 36 ka with 4 pole adjustable thermal fixed magnetic setting with onofftrip indicatorand spreaders phase barrier- 01 nos b mccb tpn 415 volt 50 hz ac 100 amps 25 ka with 4 pole adjustable thermal fixed magnetic setting with onofftrip indicatorand spreaders phase barrier- 02 nos c fasd starter suitable for three phase 40 hp submersible pump with over load relay having range of 36 to 75 amps coil voltage 380 to 415 volts including contactors timers single phase preventer voltmeterammeter of suitable capacity prewired complete all as specified by engr-in-charge
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid
servicing calibration and complete overhauling of 33 kv ht breaker vacuum type sf6 gas operated breaker of 1600 amp rating outdoor type mounted in 33 kv switch yard of existing make ie crompton greaves typemodecapacity by taking out 33 kv trolley from ht panel after switching off electric supply checking of all mechanical electrical control system for proper functioning eg spring charge system triping system remote operation indication system upward-downwardin-out movement of ht 33 kv breaker trolley etc including diassembling of operating mechanism parts well cleaning with petrol and crc-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board main busbar decarbonizing all joints busbar cts pts spouts metal parts applying the proper lubrication greasing with ap-3 grease and making 33 kv breaker perfect operating in manual and electric mode and calibration checking of indoor control panel of 33 kv circuit breaker by chechingh of tripping system through idmt over current and earth fault relay at plug setting through primary current injection method to ensure proper function of trip coil control circuit etc during fault condition setting by expert from authorised engineer and agency of authorised company of circuit breaker including submission of calibration certificate complete all as specified and directed note- replacement of unsv spare parts required to make 33 kv circuit breaker functional will be measured and paid separately as supply fixing under respective items, sf tnc control switch complete all as specified and directed, sf panel heater thermostat switch complete all as specified and directed, sf closing coil complete all as specified and directed, sf auxillary relay for buchholz relay oil temp winding temp trip 24110v dc as per exsting complete all as specified and directed, sf master relay 24110v dc as per existing complete all as specified and directed, sf remote local switch as per exsting complete all as specified and directed, supply fixing connecting and testing spring charging motoruniversal motor for outdoor type 33 kv vcb operated on 230 volts ac dc with charging time less than 15 sec of approved rating complete all as specified and directed by eic make - delco or equivalent make as approved by age i, supply and fixing of 33 kv 50 hz single phase oil filled inductive potential transformer outdoor type ratio - 33sqrt3110sqrt3 two secondary windings voltage factor - 12 continuous 15 for 30 sec creepage 900 mm windding - 1 class-10 100 va suitable for 33 kv complete all as specified and directed by engr-in-charge, sf in replacement vaccum interrupter unit of 33 kv out door type circuit breaker complete with insulator and assembly 630 amps rating all including assembling testing and commissioning at site complete all as specified and directed, supply and fix in replacement auxilary relay 110-250 volt dc suitable for over current earth fault switch gear protection complete all as specified and directed make- alsthom model no- vaa21zg8502fm or technocommercialy equivalent as approved by agei, supply and fix in replacement of 33 kv numerical 3 phase over current 1 earth fault switchgear protection relay with instantaneous high set and programmable output to simplify feeder protection wiring etc complete and testing on completion make- crompton model no cgl14c or technocommercialy equivalent as approved by agei, supply and fixing testing commisioning of electro mechanical type under overvoltage protection relay for 11 kv of make- alstom or equivalent make including neccesary wiring complete all as specified and directed note all tp accesories for testing is carried out by contractor and no extra payment to be done for testing, supply and refilling of sf6 gas suitable for ht 33 kv breaker complete all as specified and directed, sf in replacement indication lamp led type red or yellow or green or blue colour suitable for 24 v to 100 volts dc as required at site complete all as specified and directed by eic, supply and fix in repair ampare meter ammeter with digital display suitabale for measuring 33 kv electrical parameters fixed in existing panel board etc complete all as specified and directed make- secureaeschneider, supply and fix in repair voltmeter with digital display suitabale for measuring 33 kv electrical parameters fixed in existing panel board etc complete all as specified and directed make- secureaeschneider, sf in repair of strip type heater 4060 watt approx 46 in length including replacement of burnt internal wiring thermostat cut out complete all as specified and directed, ml for repair testing of control cablewiring between 3311 kv vcbs and power transformers including replacement of unserviceable and damaged cablewire with suitalbe size with connector and thimble complete all as specified and directed note control cable made up of copper will be measured and paid separately, sf in replacement of us control cable with copper conductor pvc insulated sheathed armoured of size 15 sqmm 8 core complete all as specified and directed, sf in replacement of us control cable with copper conductor pvc insulated sheathed armoured of size 15 sqmm 4 core complete all as specified and directed, servicing and maintenance of floating cum boosttrickle battery charger bank cum tripping unit for properly working on input voltage 230 v ac and output voltage 24 v dc 120 amp including replacement of us indicating lamp and meter complete all as specified and directed, supply fixing in replacement of rechargeable sealed lead acid battery maintenance free of capacity 2 volt 100 ah for breaker panel charger to provide 24 v dc supply to 33 11 kv vcbs complete all as specified and directed, servicing calibration and complete overhauling of oltc on load tap changer of 3150 kva 33kv11kv transformer of make crompton greaves after switching off electric supply checking of all mechanical electrical control system for proper functioning eg spring charge system triping system remote operation indication system upward-downwardin-out movement of tap changing mechanism oil level and winding condition heater assembly gears movements etc including diassembling of operating mechanism parts well cleaning with petrol and crc-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete decarbonizing all joints busbar cts pts spouts metal parts applying the proper lubrication greasing with ap-3 grease and making oltc perfect operating in manual and remote control mode and calibration checking of indoor control panel rtcc remote tap changer control panel by checking of tripping system and wiring of tap changer on remote and manual mode for increace of tap and decrease of tap positionsthrough avrautomatic voltage regulating relay relay and to ensure proper function of tap changing mechanism by expert from authorised engineer and agency of authorised company of circuit breakerand transformer including submission of calibration certificate complete all as specified and directed note- replacement of spare parts required to make 33 kv oltc of 3150 kva transformer in functional condition will be measured and paid separately under respective items, supply fixing and testing of automatic voltage regulating avr relay control assembly work on aux supply 90v-260v acdc and pt supply -110 volt complete of on load tap changer control rtcc remote tap changer control panel of 3150 kva 33kv11kv transformer of make cromton greaves complete all as specified and directed, servicing and maintenance of three phase induction motor of capacity 13 hp 415 volts 50 hz along with servicing of gear sets used in oltc of 3150 kva transformer alongwith servicing of mechanical movable parts and accessories of tap changing mechanism on manual and remote mode including checking of contactors fuses and thermostatswithces complete all as specified and as directed, sf in replacement pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 33000 volts grade complete all as specified and directed, sf in replacement ht 33 kv post insulator including fixing arrangements complete all as specified and directed, ml for disc type insulator porcelain vitreous in single disc assy for tension with tension clamps for conductors working pressure 33000 volts of specified size complete all as specified and as directed, supply and install ht 33 kv630 amp ht bushing insulator including fixing arrangements for 315 mva transformer complete all as specified and directed, ml in replacement spindle for pin insulator suitable for 33000 volts grade complete all as specified and as directed by engr-in-charge, ml for servicing repairs to air-break switch isolator off load rotating type 33 kv 800 amps to 1250 amps capacity with proper alignment of isolator rotating blades with fixed contact jaws arcing horns applying petrolium jelly to moving mechanism cleaning and lubricating to isolator gear box assembly tightening all nuts bolts and clamps of jumpers etc repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning testing and commissioning on load complete all as specified and directed, supplying and fixing in repairs malemoving contact rotating blade of hde copper silver plated of air brake off load isolator switch rotating type 33 kv 1250800 amps capacity with all fixing nuts bolts etc complete all as specified and directed, supplying and fixing in repairs fixed contacts made of hde copper silver plated of air brake off load isolator switch rotating type 33 kv 1250800 amps capacity with all fixing nuts bolts etc complete all as specified and directed, supplying and fixing of terminal pad for air brake off load isolator switch rotating type 33 kv 1250800 amps capacity complete all as specified and directed, supply and install ht 33 kv drop out fuse with double stack channel type insulator including fixing arrangements all as specified and directed, supply and install ht 33 kv jaw clamp including fixing arrangements all as specified and directed, ml for lightining arrester expulsion type set of three as per existing makemodelcapacity to be fixed on existing structure complete with all fitting transmission class discharge capacity 65 kilo amps suitable for 33000 volts incl taking down old one etc complete as specified and directed, sf in replacement pg parallel groove clamps as per is- 5561 2018 for 33 kv11 kv acsr conductors complete all as specified and directed by eic, supply installation testing and commissioning in replacement of air- break off load line isolator switch rotating type manually gear drive mechanism operated highest system voltage 36 kv rated current 1250 amps triple pole with earthing device each pole consist of insulating pedestals 03 nos on galvanized steel base as per bss is incuding rotating blade of hde copper and fixed contacts of same material spring loaded arcing horns of adequate section to brake magnetizing current of transformer as directed with adequate 50mm dia gi operating pipe for operation from ground level and operating handle complete with both off and on positions complete all as specified and directed, disconnecting all the electric connections from ht and lt side incl earthing terminals from the transformers and taking down transformer from plinth by using cranehydra and opening of top cover for visual inpection for the tap changer and winding condition or as required at site and reinstall at existing location including testing of 3311 kv capacity 315 mva all as specified and directed by engineer-in-charge note- replacement of unsv spare parts required to make transformer functional shall be measured and paid seperate as sf under respective item of work, supply fixing of hv bushing with terminal rod complete all as specified and directed, supply fixing of lv bushing with terminal rod complete all as specified and directed, labour for repairs to the leaks of transformer from tap switch fins any pats of body by replacing gasket seal or repairs to the leaks of transformer body fins by welding brazing etc complete all as specified and directed, ml in repair replacement of prv pressure relief valve of outdoor transformer capacity 3150 kva 33kv11 kv as existing size model complete with its connected wiring and control all as specified directed by engr-in-charge, ml for servicing of buchholz relay of outdoor transformer capacity 3150 kva 33kv11 kv as existing size model complete by connected wiring oil levels lekage arresting and checking of oil level complete all as specified directed by engr-in-charge, sf of breather assembly transparent type filled with silica gel of fresh blue colour suitable for transformer of capacity up to 3150 kva complete all as specified and directed, supply fixing of circular oil level gauge indicating meter with complete float valve assembly for fixing on conservator tank of 3150 kva 33kv11 kvtransformer complete all as specified and as directed, dehydrationfiltration of transformer oil of transformer and oltc by centrifuging machine without disturbing electric supply by heatingfiltration of oil to achieve dielectric strength not less than 60 kv when measured at 25 mm gap for one minute and topping up to oil level mark at the conservator complete all as specified and directed by engineer-in-charge note- i the contractor shall make his own arrangement for centrifuging machine motorised break down kit and all tp and manpower required at site centrifuging and topping up etc and unit rate quoted shall be deemed to include for the same ii new transformer oil as required shall be measured and paid separatly under respective item as supply only iii the rate quoted by contractor shall deem to be included for three phase generator supply for dehydaration if required iv record of new insulating oil used for replacement and topping up oil in transformer shall be maintained duly signed by rep of contractor and age em, supply only new transformer oil as per is for topup with dielectric strength not less than 60 kv complete all as specified and directed by engineer - in - charge make- savitapower oilhp, ml for hiring of cable fault detector to detect exact position of fault for xlpe pvc ht cable 11000 33000 volts grade heavy duty aluminium conductor of any size complete all as specified and directed by engr-in-charge, ml for fixing in repair end joint kit for 11 kv earthed grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and testing after jointing complete note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed, supply jointing and testing in replacement of indoor type cable end termination joint heat shrinkable suitable for aluminium conductor cable of size 240 sqmm x 3 core to 300 sqmmx 3core 11000 volts grade complete all as specified and directed note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed make- densonraychem3mcabseal, sf in repairs cable jointing kit for 33 kv earthed grade cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed note- item rate quoted including required tprefixing reconnection of cable in the panelpole cable joints complete all as specified and directed make-densonraychem3mcabseal, ml in repairreplacement for earthing complete with using copper earth plate electrode 600 mmx 600 mmx315 mm thick buried directly in ground earth pit not less than 225 mtr deep below ground level with top edge of the earth plate not less than 150 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 20x3mm copper earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switchcontrol board at another end gi earth lead incased in and including 50 mm dia gi light grade pipe from upper end of earth plate upto equipment with including 20 mm dia bore gi pipe light grade as water pipe from earth chamber to upper edge of the earth plate gi funnel with wire mesh fixed on water pipe and provision of pcc 124 type b1using 20 mm graded stone agg as in pits chamber and rcc pit cover 50 mm thick of precast rcc 124 type b-1 using 20 mm graded stone agg including necessary excavation and earth work in softloose soil all as shown in electric plate no 3 of ssr part-i and testing on completion complete all as specified and directed by engr-in-charge, ml in repairreplacement for earthing complete with using galvanized steel earth plate electrode 600 mmx 600 mmx 60 mm thick buried directly in ground earth pit not less than 225 mtr deep below ground level with top edge of the earth plate not less than 150 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32x6 mm gi earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switchcontrol board at another end gi earth lead incased in and including 50 mm dia gi light grade pipe from upper end of earth plate upto equipment with including 20 mm dia bore gi pipe light grade as water pipe from earth chamber to upper edge of the earth plate gi funnel with wire mesh fixed on water pipe and provision of pcc 124 type b1using 20 mm graded stone agg as in pits chamber and rcc pit cover 50 mm thick of precast rcc 124 type b-1 using 20 mm graded stone agg including necessary excavation and earth work in softloose soil all as shown in electric plate no 3 of ssr part-i and testing on completion complete all as specified and directed by engr-in-charge, sf in repairreplacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduitpipe or fixed to poles or any other indicated situation for loop earthing etc as required by copper strip 20x3 mm all as specified and as directed, sf in repairreplacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduitpipe or fixed to poles or any other indicated situation for loop earthing etc as required by galvanized iron strip 32x6mm complete all as specified and directed, labour for cutting trimming of tree branches up to 80 mm wide all around from the outer face of alignment of 33 kv ht over head electric line which are going touching or falling or acsr conductor poles or near by sub stns etc at any height from gl and making clearance 15m form conductor and removing to a distance up to 100 mtr where directed by engineer-in-charge note- i trimming of the branches on one sides of the conductor ii actual length of cutting will be measured iii the distance as motioned above will be maintained during contract current period same location subject to at least 6 months period between two trimminglopping iv measurement will be taken including all conductor as one only, mlfor preparatiom of old treated steel surface of any description of 33 kv yard and applying one coat of synthetic enamel paint complete all as specified, mlfor preparatiom of old treated pcc plastered surface of wall foundation of 33 kv yard and applying one coat of white wash complete all as specified, clearing away all grass vegetation saplings shrubs brush wood undergrowth roots and trees not exceeding 30 cm girth measured one metre above ground level and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance softloose soil and getting out including sprinkling anti vegitation chemical for complete area with spray machine complete all as specified directed, a line isolator 33 kv horizontal type - servicing of line isolator horizontal break outdoor type including cleaning of contact by ctc liquid proper oiling greasing on contacts moving rod handle for proper function of moveable rod for smooth on off position and checking the incoming and outgoing connection including replacement of terminal lugspg clamps with nut bolts etc and testing with following i meggar testing between phase to phase phase to earth shall be carried out, b ht potential transformer or 33 kv 110 volt outdoor type - cleaning of bushing and terminal of ht potential transformer 33 kv 110 volts outdoor type by ctc liquid and checking of oil level and oil dielectric strength bd test and proper connection checkingtightining of control wiring and testing with following - i meggar testing between phase to phase phase to earth, c ht 33 kv or 11 kv outdoorindoor type current transformer ct cleaning of bushing and terminal by ctc solution of ct 33 kv or 11 kv of any ratio and any type and checking of oil level and oil dielectric strength bdv test and for 11 kv checking of wiring circuits and decarbonising of cablebusbar jointsand proper connection checkingtightining of control wiring and testing with following i testing between phase to phase phase to earth to be carried out by external current injection kit, d 3311 kv vcbbreaker control relay panel 02 nos 33 kv panel - cleaning of control relay panel inside outside and checkingtightningrewiring if required cost of new wire is included in quoted rate all the control cable connection of ct pt vcb meters trivector meter transformer complete and testing with the following - i over current earth fault relay tripping by external current injecting kit on primarysecondary side ii buccholz relay alarm tripping testing iii oil temperature alarm tripping testing iv winding temperature alarm tripping testing v all selector switchesindication lamps such as localremoteonoff accept reset push button indication lamp checkedreplaced if required complete the cost of switchindication lamps will deemed to be included in quoted rate, etransformer 33 11 kv up to 315 mva - cleaning of power transformer 33 11 kv outdoor type externally including all accessories such as conservator tank marshaling box bushings bucholz relay radiator bushings oil level indicator complete and checking the incoming and outgoing terminal connection complete with the following testing - i transformer oil dielectric strength bd voltage test ii buccholz relay alarm trip testing iii oil temprature alarm trip testing iv winding temprature alarm trip testing v meggar testing between hv to earth vi meggar testing between lv to earth vii meggar testing between hv to lv viii earth resistance test for body earthing ix replacement all packing and viewing glass in marshilling box if required, f do fuse 33 kv cleaning of 33kv ht insulators checking the incoming outgoing joint connection replacing with new do fuse of approved rating including replacement of conductor clapms by replacing rusted nut bolts etc and testing with the following - i meggar testing between phase to phase phase to earth, ml for cement concrete for filling in foundations or making good of road pcc floor supports etc type b1 124 using 20 mm graded crushed stone aggregate including necessary form work and fair finishing of exposed surface of concrete facia finish with cement mortar complete all as directed, supply of fuse wire made up of tinned copper of rating 20 amp to 60 amp complete all as specified and directed note- fuse wire shall be taken on charge and record of consumption of same shall be maintained by ageje em, supply of ht insulation tapes roll isi marked for terminating high voltage 3311 kv cables for insulation sealing of connection of wire and cable for bus bar insulation transformer terminal insulation etc complete all as specified and directed, supply and fixing in replacement of danger notice plate 33000 volt and 11000 volt of 16mm thick ms sheet vitreous enamelled white with letters figuers and conventional skull and bones in signal red colour and fixed with ms clamps made out of flat iron 25x3 mm nuts-bolts of approved size for ht 25 x 20 cm and complete all as specified and directed, ml for hardcore of broken stone or boulders gauge of 40mm to 63 mm deposited spread and levelled in layers n exc 15cm thick around ht four poletwo pole structure and transformer area complete all as specified, repair to earth pit earth pit cover of 3311 kv switchyard by using pcc 124 and plastering in cm 13 complete including excavation returning filling and removal etc complete all as specified and directed, supply and laying in replacement of ht high voltage insulation mat size 2mx1m made of elastomeric polymers material having a high insulation registance thus imparting total saety to human being from any leakage current having high insulation registance of class a of size 30 mm thick and 1 m width suitale for 33 kv confirming to is-15652 2006 including pasting of mat with sr-998 by adding thinner as per requirement complete all as specified and directed
AI summaryBid / No Bid DecisionGenerate annexuresDraft Full Bid